Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 94(1): 91-97, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-30636371

RESUMEN

BACKGROUND: Although bioresorbable polymer sirolimus-eluting Ultimaster stents (BP-SESs) are likely useful for percutaneous coronary interventions (PCIs), the clinical data from real-world cases are insufficient. Furthermore, the predictors of adverse clinical outcomes after BP-SES implantation have not been fully investigated. OBJECTIVES: This study evaluated the 1-year clinical outcomes after BP-SES implantation in real-world PCI cases and identified the predictors of adverse outcomes. METHODS: In this single-center, all-comers study, we consecutively implanted BP-SESs in all patients who required coronary stents between October 2015 and August 2016. We conducted a clinical follow-up assessment of these patients. RESULTS: The sample comprised 1,727 patients; 67% were men, the mean age was 72 years, and 37% had diabetes. Of the 2,085 lesions detected, 88% were type B2/C lesions, 4% were chronic total occlusions (CTOs), and 23% were bifurcations. The cumulative incidences of target lesion revascularization (TLR) and target lesion failure (TLF) at 1-year were 2.4% and 5.2%, respectively. A multivariate analysis revealed that hemodialysis (HD) (hazard ratio [HR] 8.40) and CTO (HR 4.21) were independent predictors of TLR. Stent sizes ≤2.5 mm were not associated with either TLR or TLF. CONCLUSIONS: The current study indicates that patients on HD and those with CTO were more likely to experience adverse clinical outcomes after BP-SES implantation. In contrast, small vessel diameter was not significantly related to adverse outcomes. The 1-year clinical outcomes after BP-SES implantation were found to be favorable among all-comer PCI cases, including patients receiving HD and those with in-stent restenosis.


Asunto(s)
Implantes Absorbibles , Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Oclusión Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Anciano de 80 o más Años , Fármacos Cardiovasculares/efectos adversos , Enfermedad Crónica , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/mortalidad , Femenino , Humanos , Japón , Enfermedades Renales/mortalidad , Enfermedades Renales/terapia , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Diseño de Prótesis , Diálisis Renal , Medición de Riesgo , Factores de Riesgo , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
2.
Heart Vessels ; 31(4): 465-73, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25630713

RESUMEN

Even in the drug-eluting stent era, diabetes mellitus (DM) patients have high incidences of restenosis and repeat revascularization after percutaneous coronary intervention. The aim of this study was to compare vascular response after stent implantation between sirolimus-eluting stent (SES) and paclitaxel-eluting stent (PES) by using optical coherence tomography (OCT) in DM patients as well as in non-DM patients. In the Japan-Drug Eluting Stents Evaluation; a Randomized Trial (J-DESsERT), the OCT sub-study enrolled 75 patients who underwent 8 months follow-up imaging after SES or PES implantation. Mean neointimal hyperplasia (NIH) thickness was significantly thinner in SES than PES in the DM group (77 ± 47 vs. 201 ± 114 µm, p < 0.001) and in the non-DM group (84 ± 37 vs. 212 ± 128 µm, p < 0.001). Unevenness of NIH thickness in longitudinal axis was significantly smaller in SES than PES in the DM group (348 ± 191 vs. 726 ± 385 µm, p < 0.001) and in the non-DM group (344 ± 174 vs. 679 ± 314 µm, p < 0.001). The percentage of uncovered struts was significantly greater in SES than PES in the DM group (24 ± 4 vs. 9 ± 14 %, p < 0.001) and in the non-DM group (16 ± 16 vs. 3 ± 4 %, p = 0.002). Compared with PES, SES showed more potent NIH inhibition in DM patients as well as in non-DM patients.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/cirugía , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Tomografía de Coherencia Óptica/métodos , Grado de Desobstrucción Vascular/fisiología , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Vasos Coronarios/cirugía , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Neointima/patología , Estudios Prospectivos , Factores de Tiempo
3.
Heart Vessels ; 30(2): 270-3, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24408671

RESUMEN

We report an autopsy case of a coronary aneurysm with massive adventitial inflammation post-percutaneous coronary intervention with sirolimus-eluting stent (SES) insertion in the left circumflex (LCX) coronary artery for ischemic heart disease 3 years prior to death. The internal elastic membrane was disrupted opposite the site of the eccentric LCX plaque due to injury during stenting, and the adventitia showed massive inflammatory cell infiltration, mainly consisting of eosinophils. The LCX showed aneurysmal dilatation with inflammatory cell infiltration. Inappropriate SES implantation attracted chronic inflammation. Chronic inflammation can lead to the development of coronary artery aneurysms.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Aneurisma Coronario/etiología , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/lesiones , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Lesiones Cardíacas/etiología , Inflamación/etiología , Intervención Coronaria Percutánea/instrumentación , Lesiones del Sistema Vascular/etiología , Anciano de 80 o más Años , Autopsia , Aneurisma Coronario/diagnóstico , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Resultado Fatal , Femenino , Lesiones Cardíacas/diagnóstico , Humanos , Inflamación/diagnóstico , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Resultado del Tratamiento , Ultrasonografía Intervencional , Lesiones del Sistema Vascular/diagnóstico
4.
Circ J ; 78(1): 110-21, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24189503

RESUMEN

BACKGROUND: The advantages of the final kissing balloon technique (FKB) in a provisional 1-stent approach are under debate. Long-term clinical outcomes remain unclear due to limited data. METHODS AND RESULTS: Of 2,132 patients (2,502 lesions) enrolled in the TAXUS Japan Postmarket Surveillance Study at 56 centers between July 2007 and December 2008, patients having coronary bifurcation treated with a single cross-over stenting with FKB (FKB-group: 132 patients/137 lesions) were compared to those treated without FKB (no-FKB-group: 121 patients/124 lesions). The no-FKB-group was also compared with non-bifurcation patients who had a single-stent implantation (814 patients/937 lesions). The primary outcome was MACE (major adverse clinical events), defined as cardiac death, myocardial infarction and target vessel revascularization (TVR) at 3 years. Higher late loss and binary restenosis were found in the main vessel (MV) of the FKB-group at the 9-month angiogram compared to the no-FKB-group. At 3 years, MACE was numerically higher (14.6% vs. 6.9%, P=0.07) and TVR was significantly higher (14.6% vs. 5.9%, P<0.05) in the FKB-group compared with the no-FKB-group. The rate of MACE (6.9% vs. 10.4%, P=0.34) and TVR (5.9% vs. 7.7%, P=0.57) were similar between the no-FKB and non-bifurcation patients. CONCLUSIONS: In a 1-stent approach, FKB was associated with worse angiographic outcomes in the MV, and did not demonstrate any clinical benefit over the long-term follow-up period. Cross-over stenting without FKB showed similar clinical outcomes to patients without bifurcation.


Asunto(s)
Angiografía Coronaria , Oclusión de Injerto Vascular/diagnóstico por imagen , Oclusión de Injerto Vascular/mortalidad , Vigilancia de Productos Comercializados , Stents , Anciano , Muerte , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Tasa de Supervivencia , Factores de Tiempo
5.
Pathol Int ; 64(7): 325-35, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25047503

RESUMEN

It is of importance to clarify pathophysiology of diabetic heart diseases such as heart failure and coronary artery disease. We reported a novel clinical phenotype called triglyceride deposit cardiomyovasculopathy (TGCV), showing aberrant TG accumulation in both coronary arteries and myocardium, in a cardiac transplant recipient. Here, we examined autopsied diabetics for TG deposition in cardiovasculature. Consecutive series of hearts from advanced diabetes mellitus (DM) subjects (DM group: DMG, n = 20) and those from age- and sex-matched non-diabetic controls (non DM group: NDMG, n = 20) were examined. The diagnostic criteria of 'advanced DM' was made based on 2014 Clinical Practice Recommendations proposed by the American Diabetes Association. The mean duration of DM was 15.8 years. All DMG suffered from heart diseases including coronary artery diseases and 14 subjects had multi-vessel disease. Tissue TG contents were measured biochemically. Coronary arterial TG contents was significantly higher in DMG compared with NDMG. Spatial distribution of TG in transverse sections of coronary arteries showed TG deposition mainly in smooth muscle cells by Imaging Mass Spectrometry. Abundant TG deposition in coronary artery might be associated with advanced DM.


Asunto(s)
Enfermedad Coronaria/metabolismo , Vasos Coronarios/metabolismo , Complicaciones de la Diabetes/metabolismo , Diabetes Mellitus/metabolismo , Triglicéridos/metabolismo , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/patología , Enfermedad Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Músculo Liso/patología
6.
Heart Vessels ; 29(2): 273-7, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23595778

RESUMEN

A 60-year-old man who had received repeated angioplasty for silent ischemia was suspected to have restenosis based on radioisotope imaging (exercise-RI) findings 6 months after everolimus-eluting stent (EES) implantation (3.5 × 28, 3.5 × 28, 3.0 × 18 mm). The stents had been implanted for chronic total occlusion of the right coronary artery (RCA), and the patient was on continuous dual antiplatelet therapy. Diagnostic angiography demonstrated in-stent restenosis in the proximal RCA, which was treated by optical coherence tomography (OCT)-guided cutting balloon angioplasty with distal protection. OCT findings of the stenotic segment before angioplasty showed that the lesion had complex features. The lesion was successfully dilated, and whitish material obtained by a distal protection device was composed of fibrin thrombi with neutrophils and small pieces of mature fibrocellular neointima. The mechanisms and patterns of restenosis after EES placement have not been well clarified. This case may reflect a restenosis pattern (i.e., asymptomatic, focal, and thrombi-related) in the era of the newer generation of drug-eluting stents.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/análogos & derivados , Angioplastia Coronaria con Balón , Angiografía Coronaria , Reestenosis Coronaria/diagnóstico , Reestenosis Coronaria/terapia , Trombosis Coronaria/diagnóstico , Trombosis Coronaria/terapia , Everolimus , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Índice de Severidad de la Enfermedad , Sirolimus/administración & dosificación , Tomografía de Coherencia Óptica , Resultado del Tratamiento
7.
Am Heart J ; 166(3): 527-33, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24016503

RESUMEN

BACKGROUND: The aim of this study was to investigate the efficacy and safety of paclitaxel-coated balloon (PCB) for the treatment of the bare-metal stent restenosis (BMS-ISR) and drug-eluting stent restenosis (DES-ISR). METHODS: This study was a prospective, multicenter, randomized (2:1) trial conducted in 208 patients with 213 in-stent restenosis lesions (BMS-ISR: 123 lesions, DES-ISR: 90 lesions) at 13 centers in Japan. Patients were randomly assigned to a PCB group (137 patients with 142 lesions) or a conventional balloon angioplasty (BA) group (71 patients with 71 lesions). The primary end point was target vessel failure at 6-month follow-up. RESULTS: Clinical and angiographic follow-up 6 months after intervention was performed in 207 patients (99.5%) with 208 lesions (97.7%). Target vessel failure was noted in 6.6% of the PCB group and 31.0% of the BA group (P < .001). Recurrent restenosis occurred in 4.3% of the PCB group and 31.9% of the BA group (P < .001). Late lumen loss was lower in the PCB group than in the BA group (0.11 ± 0.33 mm vs 0.49 ± 0.50 mm, P < .001). In PCB-treated lesions, recurrent restenosis occurred in 1.1% of patients with BMS-ISR and in 9.1% of patients with DES-ISR (P = .04). Late lumen loss was lower in patients with BMS-ISR than in patients with DES-ISR (0.05 ± 0.28 mm vs 0.18 ± 0.38 mm, P = .03). CONCLUSIONS: This randomized clinical study suggested that PCB provided much better clinical and angiographic outcomes than did conventional BA in patients with BMS-ISR and DES-ISR. Drug-eluting stent restenosis was associated with poorer outcomes compared with BMS-ISR after treatment with PCB.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Oclusión de Injerto Vascular/terapia , Paclitaxel/uso terapéutico , Stents/efectos adversos , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Angiografía Coronaria , Reestenosis Coronaria/etiología , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/etiología , Humanos , Japón , Masculino , Metales , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
8.
Circ J ; 77(6): 1430-5, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23428716

RESUMEN

BACKGROUND: Although previous randomized and non-randomized studies have demonstrated the safety and efficacy of paclitaxel-eluting stents (PES), a higher revascularization rate has been reported in women than in men. A sub-analysis of the TAXUS Japan Post-market Surveillance Study (TAXUS-PMS) was done to assess the influence of gender on clinical outcome. METHODS AND RESULTS: A total of 2,132 PES-treated Japanese patients (women, n=551) from this registry were analyzed. Subjects were stratified by gender to compare 1-year clinical outcome. PES-treated women were older and more likely to have insulin-treated diabetes and hypertension. In contrast, PES-treated men were more likely to be smokers, have a previous history of myocardial infarction, and lower ejection fraction. While cardiac death, myocardial infarction and stent thrombosis were similar between men and women, major cardiac events tended to be lower in women than in men (6.4% vs. 8.8%, P=0.08). Although women had significantly smaller reference vessel size (2.46±0.53 mm vs. 2.59±0.60 mm, P<0.0001), the restenosis rate tended to be lower in women than in men (11.5% vs. 14.8%, P=0.11). Subsequently, the target lesion revascularization rate was significantly lower in women than in men (4.2% vs. 6.5%, P<0.05). CONCLUSIONS: Despite a higher risk profile, Japanese women treated with PES did not have a higher rate of repeat revascularization or major adverse clinical outcome than PES-treated men at 1 year.


Asunto(s)
Antineoplásicos Fitogénicos/farmacología , Muerte , Stents Liberadores de Fármacos , Infarto del Miocardio , Paclitaxel/farmacología , Sistema de Registros , Anciano , Anciano de 80 o más Años , Pueblo Asiatico , Femenino , Oclusión de Injerto Vascular , Humanos , Japón/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Infarto del Miocardio/fisiopatología , Vigilancia de Productos Comercializados , Ensayos Clínicos Controlados Aleatorios como Asunto , Caracteres Sexuales , Factores Sexuales , Factores de Tiempo
9.
Cardiovasc Revasc Med ; 51: 10-17, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36804303

RESUMEN

BACKGROUND: When a catheter device is delivered during percutaneous coronary intervention, its passage can be disrupted by a deployed in a coronary artery. However, the condition and details of this phenomenon, that is impeded-by-stent phenomenon (ISP), remain unclear. METHODS: We designed a prospective, open-label, single-center, observational study to clarify the incidence, predictors, and clinical impact of ISP in drug-eluting stents (DESs). Two independent operators observed and judged the occurrence of ISP, which was defined as all disturbances to a device delivery by deployed DESs. We consecutively used the Ultimaster™ (Terumo, Tokyo, Japan) DES for one month (109 patients, October 2018), followed by the Synergy™ (Boston Scientific Corporation, Marlborough, MA, USA) DES the next month (119 patients, November 2018). RESULTS: DESs (2.5-4.0 mm in diameter) were implanted in 230 de novo coronary vessels. ISPs were observed in 17 of 239 stented segments (7.1 %). Multivariate analysis showed that bifurcation lesions (adjusted odds ratio [OR], 4.2; 95 % confidence interval [CI], 1.5-12.6; p = 0.008), predilatation balloon diameter (mm) (OR, 0.2; 95 % CI, 0.1-0.9; p = 0.03), and Ultimaster™ use (OR, 6.0; 95 % CI, 1.9-27.2; p = 0.002) were independent predictors of ISPs. During the 1.5-year follow-up period, no repeat revascularization or stent thrombosis occurred in patients with ISP. CONCLUSIONS: ISP itself does not trigger notable clinical outcomes, including repeat revascularization and stent thrombosis. However, caution should be considered regarding the latent risk of procedural complications.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Humanos , Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio/etiología , Incidencia , Estudios Prospectivos , Resultado del Tratamiento , Stents/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Trombosis/etiología , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Diseño de Prótesis
10.
Cardiovasc Revasc Med ; 37: 43-49, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34266771

RESUMEN

BACKGROUND: This study aimed to clarify the factors for efficient procedures (EP) in superficial femoral artery (SFA) chronic total occlusion (CTO). METHODS: We retrospectively analyzed 200 consecutive limbs that underwent treatment for SFA CTO. The patients were divided into three groups according to the main strategies: subintimal angioplasty (SIA) (n = 123), Crosser use (n = 50), and 0.014″ CTO guidewire (CTO-GW) (n = 27). To determine the factors for an EP (EP; contrast volume <130 mL and procedure time <20 min; derived from non-CTO [control] procedures), the variables (P < 0.2) underwent multivariate analysis. RESULTS: SIA included more Trans-Atlantic Inter-Society Consensus C/D lesions and contralateral femoral approaches, and additional GW use (P < 0.05). CTO-GW presented a shorter occlusion length and elapsed time, and used less retrograde approach than the other strategies (P < 0.05). Crossers had a higher incidence of perforation (P = 0.002). The prompt retrograde approach had a similar actual retrograde procedure time, but a shorter total procedure time, compared to that of the delayed adoption (P < 0.001). EP was achieved in 14 limbs (7.0%). Multivariate analysis revealed that occlusion length (adjusted odds ratio [OR], 0.89; 95% CI, 0.81-0.96; P = 0.004) and SIA (OR, 8.71; 95% CI, 1.32-175.27; P = 0.02) were associated with EP. CONCLUSIONS: SIA contributed to EP. The timing of the retrograde approach was crucial because its delay resulted in an excessive procedure time.


Asunto(s)
Arteria Femoral , Enfermedad Arterial Periférica , Angioplastia/métodos , Enfermedad Crónica , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Humanos , Extremidad Inferior , Enfermedad Arterial Periférica/cirugía , Enfermedad Arterial Periférica/terapia , Estudios Retrospectivos , Resultado del Tratamiento
11.
J Heart Lung Transplant ; 41(7): 877-885, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35400587

RESUMEN

BACKGROUND: Detailed morphological characteristics of de novo and donor-transmitted plaques and the association of serum T-lymphocyte cytokine levels with plaque progression of coronary allograft vasculopathy within 1 year after heart transplantation are unknown. METHODS: In this retrospective analysis of data in a prospectively maintained database, 40 heart transplant recipients were included. We performed serial 3 vessel optical coherence tomography and intravascular ultrasound analyses, at the 8 week (baseline) and 12 month post-transplantation follow-ups, and serum cytokine measurements (n = 23). The correlation between serum cytokines and Δplaque burden (between baseline and follow-up) was evaluated depending on plaque morphology. RESULTS: Thirteen de novo plaques (maximum intimal thickness ≥0.5 mm at the 12 month follow-up without plaques at baseline) were identified in 8 recipients, and 31 donor-transmitted plaques (maximum intimal thickness ≥0.5 mm at baseline) were detected in 17 recipients. Compared with donor-transmitted plaques, the Δplaque burden in the de novo plaques, with mainly fibrous morphology, was high (38.8% [29.6%-41.2%] vs 8.7% [1.33%-13.6%], p < 0.001). Stratification of the morphology of donor-transmitted plaques revealed that the Δplaque burden in fibrous plaques (10.6% [7.0%-18.0%]) was similar to that in fibroatheroma (10.3% [8.7%-23.8%]). Serum interleukin-31 levels at baseline correlated with fibrous plaque proliferation (r = 0.73, p = 0.007) even under immunosuppressive conditions, whereas other cytokines (interleukin-1ß, interleukin-17, and interferon-gamma) were mostly undetectable. CONCLUSIONS: Intimal fibrous proliferation contributed to the progression of donor-transmitted and de novo plaques. Serum interleukin-31 levels at baseline may contribute to intimal fibrous proliferation within 1 year after heart transplantation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Trasplante de Corazón , Placa Aterosclerótica , Aloinjertos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/inmunología , Citocinas/inmunología , Trasplante de Corazón/efectos adversos , Humanos , Placa Aterosclerótica/diagnóstico por imagen , Placa Aterosclerótica/etiología , Placa Aterosclerótica/inmunología , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Ultrasonografía Intervencional/métodos
12.
Circ J ; 75(11): 2573-80, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21821962

RESUMEN

BACKGROUND: The TAXUS Japan Postmarket Surveillance Study (TAXUS-PMS) enrolled patients receiving percutaneous coronary intervention in real-world clinical practice. This analysis focuses on outcomes in the overall patient population and in a subgroup of diabetic patients. METHODS AND RESULTS: Between July 2007 and December 2008, 2,132 patients (with 2,504 lesions) were consecutively enrolled at 56 sites in Japan. One-year outcomes were analyzed. The prevalence of patients with diabetes was 44% (21% of diabetics were insulin-treated) and 5.5% of patients were receiving ongoing hemodialysis. The majority of patients received paclitaxel-eluting stents (PES) for `off-label' indications (68.2%). The rate of major adverse cardiovascular events (cardiac death, myocardial infarction, and target vessel revascularization (TVR)) at 1 year was 8.2%, driven mainly by TVR (6.9%). No differences in TVR, late loss or restenosis rates were found between diabetic and non-diabetic patients; outcomes in insulin- compared with oral hypoglycemic-treated diabetic patients, were similar. Multiple stent implantation and ostial lesion location were independent predictors for both major adverse cardiac events (MACE) and target lesion revascularization (TLR). Hemodialysis was an independent predictor for MACE but not TLR whereas in-stent restenosis was an independent predictor for TLR. CONCLUSIONS: TAXUS-PMS demonstrated a consistent, positive effect of PES in complex clinical cases. PES diminished the increased risk of clinical restenosis in diabetic patients, leading to a similar low risk of cardiac events in diabetic and non-diabetic patients.


Asunto(s)
Antineoplásicos Fitogénicos/farmacología , Paclitaxel/farmacología , Vigilancia de Productos Comercializados , Anciano , Angioplastia/efectos adversos , Angioplastia/métodos , Antineoplásicos Fitogénicos/efectos adversos , Muerte , Complicaciones de la Diabetes/mortalidad , Stents Liberadores de Fármacos , Femenino , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/mortalidad , Humanos , Hipoglucemiantes/administración & dosificación , Insulina/administración & dosificación , Japón/epidemiología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/mortalidad , Paclitaxel/efectos adversos , Prevalencia , Diálisis Renal , Estudios Retrospectivos , Factores de Riesgo
14.
Circulation ; 116(8): 910-6, 2007 Aug 21.
Artículo en Inglés | MEDLINE | ID: mdl-17684153

RESUMEN

BACKGROUND: The time course of neointimal formation after stent implantation has not been studied extensively by angioscopy in the drug-eluting stent era. METHODS AND RESULTS: Serial angioscopic findings at first follow-up (3.6+/-1.1 months), second follow-up (10.5+/-1.6 months), and third follow-up (21.2+/-2.2 months) after stent implantation were compared between sirolimus-eluting stents (SES, n=17) and bare-metal stents (BMS, n=11). Neointimal coverage, thrombus, and presence of yellow plaques underneath the stents were assessed. Neointimal coverage was graded as follows: grade 0, stent struts were fully visible; grade 1, struts bulged into the lumen, although they were covered; grade 2, struts were embedded by the neointima but were seen translucently; or grade 3, struts were fully embedded and invisible. Neointimal coverage was remarkably different between SES and BMS at each follow-up point. Neointimal coverage grade was 1.1+/-0.5 in SES versus 2.9+/-0.3 in BMS at the first follow-up (P<0.0001), 1.1+/-0.5 in SES versus 3.0+/-0.0 in BMS (P<0.0001) at the second follow-up, and 1.3+/-0.5 in SES versus 3.0+/-0.0 in BMS at the third follow-up (P=0.0009). No significant serial changes in coverage grade were noted in the BMS group, whereas coverage grade slightly but significantly increased at the third follow-up in the SES group (P<0.05). Thrombi were detected in 4 SES: a red thrombus was seen from the first to the third follow-up in 2; another was detected only at the third follow-up; and the fourth was seen at the first follow-up but disappeared at the second follow-up, associated with a new white thrombus despite dual antiplatelet therapy. Yellow plaques had disappeared by the time of the second follow-up in BMS. In contrast, yellow plaques were exposed in 71% of SES at the first follow-up and remained exposed until the third follow-up. Neointimal coverage grades correlated with thrombi (P=0.002) and with yellow plaques (P<0.0001). CONCLUSIONS: Serial angioscopic findings up to 2 years after SES implantation were markedly different from those after BMS. Neointimal coverage was completed by 3 to 6 months in BMS. In contrast, SES demonstrated the presence of thrombi and yellow plaques even as much as 2 years after implantation.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/patología , Inmunosupresores/administración & dosificación , Sirolimus/administración & dosificación , Stents , Adulto , Anciano , Angioplastia Coronaria con Balón , Estudios de Cohortes , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/patología , Reestenosis Coronaria/prevención & control , Trombosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/patología , Trombosis Coronaria/prevención & control , Vasos Coronarios/efectos de los fármacos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Metales , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Túnica Íntima/efectos de los fármacos , Túnica Íntima/patología
15.
Circulation ; 111(9): 1148-52, 2005 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-15723972

RESUMEN

BACKGROUND: The pattern of saphenous vein graft (SVG) calcification before percutaneous intervention has not been studied. METHODS AND RESULTS: We used diagnostic and preintervention intravascular ultrasound (IVUS) to determine the incidence and magnitude of SVG calcification in 334 SVG lesions in 274 consecutive patients. Calcium was found in 133 SVGs (40%). Calcium was uniformly distributed among 48 lesion sites (14%), 43 proximal references (13%), and 42 distal references (13%). Calcium was superficial in 20 (40%) and deep in 28 (60%). Over the entire length of the SVGs, the maximum arc and length of calcium (in calcium-containing SVGs) averaged 174+/-107 degrees and 6.8+/-4.8 mm, respectively. In calcium-containing SVGs, lesion site arc and length of calcium measured 151+/-107 degrees and 4.1+/-3.7 mm, similar to the proximal and distal references (175+/-121 degrees and 4.0+/-2.3 mm and 177+/-121 degrees and 4.1+/-2.5 mm, respectively). Graft age (7.5+/-4.7 versus 10.5+/-4.7 years, P<0.0001), insulin-treated diabetes mellitus (40% versus 60%, P=0.02), and tobacco use (44% versus 55%, P=0.06) were clinical independent predictors of SVG calcification. CONCLUSIONS: Sixty-five percent of calcium-containing SVGs had reference calcium in the absence of lesion calcium. Calcium was located primarily in SVG wall and not at the plaque. These data suggest that SVG calcium is not just part of lesion formation and maturation. SVG calcium occurred more commonly in older grafts, in insulin-treated diabetic patients, and in smokers.


Asunto(s)
Calcinosis/patología , Angiografía Coronaria , Puente de Arteria Coronaria , Reestenosis Coronaria/patología , Complicaciones Posoperatorias/patología , Vena Safena/patología , Ultrasonografía Intervencional , Anciano , Calcinosis/diagnóstico por imagen , Calcinosis/epidemiología , Calcio/análisis , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/epidemiología , Estenosis Coronaria/cirugía , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Hemodinámica , Humanos , Hipercolesterolemia/epidemiología , Hipertensión/epidemiología , Incidencia , Enfermedades Renales/epidemiología , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/epidemiología , Periodo Posoperatorio , Factores de Riesgo , Vena Safena/química , Vena Safena/diagnóstico por imagen , Vena Safena/trasplante , Fumar/epidemiología
16.
Am J Cardiol ; 98(2): 272-4, 2006 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-16828607

RESUMEN

Stent fracture has emerged as a new problem in the percutaneous transluminal angioplasty of the superficial femoral artery (SFA). The aim of our study was to delineate the factors influencing nitinol stent fracture in the SFA. Forty consecutive patients with peripheral artery disease who underwent rescue stenting with a nitinol stent (Luminexx, Bard) in the SFA were enrolled between May 2004 and January 2005. Follow-up angiography was performed 13.6+/-1.0 months later to detect stent fracture. Stent fracture occurred in 11 patients (28%). Lesion length>100 mm, the number of stents used, the lesion involving the distal SFA, chronic total occlusion, and walking>5,000 steps per day were more frequently observed in those with stent fracture than in those without fracture. Of these variables, walking>5,000 steps per day was the strongest independent determinant associated with stent fracture by discriminant analysis (p=0.0027). Vigorous exercise adversely affects stent fracture in patients implanted with a nitinol stent in the SFA.


Asunto(s)
Aleaciones , Arteriopatías Oclusivas/cirugía , Implantación de Prótesis Vascular/instrumentación , Ejercicio Físico , Arteria Femoral , Oclusión de Injerto Vascular/etiología , Stents , Anciano , Angiografía , Arteriopatías Oclusivas/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/diagnóstico por imagen , Humanos , Masculino , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Caminata
18.
Eur Heart J Cardiovasc Imaging ; 17(1): 51-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25976347

RESUMEN

AIMS: Neovascularization is closely associated with plaque progression in non-heart transplantation subjects; on the other hand, cardiac allograft vasculopathy causes unfavourable outcomes. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) can provide microscopic assessment in vivo. The aim of this study was to investigate the impact of neovascularization on intimal proliferation. METHODS AND RESULTS: Both IVUS and OCT were attempted in 45 consecutive patients during annual catheterization after heart transplantation. There were 115 vessels [28 vessels were catheterized within 8 weeks of heart transplantation (baseline)]. IVUS analysis assessed vessel, luminal, and intimal (vessel-lumen) volume using Simpson's method. Qualitative parameters including microchannel were assessed by OCT. A microchannel was defined as a no-signal tubuloluminal structure with a sharply delineated border considered to represent neovascularization. Microchannel was observed more often in patient who had their heart transplant more than a year prior to the imaging, compared with shorter periods (39.1 vs. 10.7%, P = 0.023). All microchannels were seen in thickness >0.5 mm, and intimal volume index (mm(3)/mm) correlated with frequency of microchannel (r = 0.54, P = 0.04). The risks for microchannels were donor age [odds ratio (OR) 1.11; 95% confidence interval (CI) 1.03-1.22; P = 0.007], cytomegalovirus infection (OR 16.21; 95% CI 1.79-220.09; P = 0.012), diabetes (OR 9.5; 95% CI 1.21-116.10; P = 0.032), LDL-cholesterol (OR 1.07; 95% CI 1.01-1.13; P = 0.010), and intimal volume (OR 2.47; 95% CI 1.13-6.36; P = 0.023). CONCLUSION: OCT-identified microchannels increased sharply within the first year and were correlated with intimal volume and coronary risks. This suggests that neovascularization may play an important role in the progression of cardiac allograft vasculopathy.


Asunto(s)
Rechazo de Injerto/prevención & control , Cardiopatías/diagnóstico , Trasplante de Corazón , Inmunosupresores/uso terapéutico , Neovascularización Patológica/diagnóstico , Tomografía de Coherencia Óptica , Túnica Íntima/diagnóstico por imagen , Ultrasonografía Intervencional/métodos , Adulto , Aloinjertos , Enfermedad Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Cardiopatías/prevención & control , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Resultado del Tratamiento
19.
Circulation ; 108(1): 43-7, 2003 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-12821553

RESUMEN

BACKGROUND: Factors leading to subacute stent thrombosis after percutaneous coronary intervention (PCI) have not been well established. We assessed the pre- and post-PCI intravascular ultrasound (IVUS) characteristics of subacute stent thrombosis. METHODS AND RESULTS: We analyzed 7484 consecutive patients without acute myocardial infarction who were treated with PCI and stenting and underwent IVUS imaging during the intervention. Twenty-seven (0.4%) had angiographically documented subacute closure <1 week after PCI (median time to subacute closure, 24 hours). Subacute closure lesions were compared with a control group (selected to be 3 times the abrupt closer group) matched by procedure date (within 6 months), age, gender, stable or unstable angina, lesion location, and additional treatment (balloon angioplasty or atherectomy). Postintervention IVUS did not identify a cause in 22% and did identify at least 1 cause for abrupt closure in 78% of patients (versus 33% in matched lesions, P=0.0002). In 48% of the patients, there were multiple causes in 48% (versus 3% in matched lesions, P<0.0001). Causes included dissection (17%), thrombus (4%), and tissue protrusion within the stent struts leading to lumen compromise lumen (4%). A total of 83% of patients with >1 of these abnormal morphologies also had reduced lumen dimensions post-PCI (final lumen <80% reference lumen). Preprocedural lesion characteristics were not different from matched lesions. CONCLUSIONS: Subacute stent thrombosis is infrequently related to the preintervention lesion characteristics. Inadequate postprocedure lumen dimensions, alone or in combination with other procedurally related abnormal lesion morphologies (dissection, thrombus, or tissue prolapse), contribute to this phenomenon.


Asunto(s)
Reestenosis Coronaria/diagnóstico por imagen , Trombosis Coronaria/diagnóstico por imagen , Stents/efectos adversos , Ultrasonografía Intervencional , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/mortalidad , Enfermedad Coronaria/cirugía , Reestenosis Coronaria/etiología , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Tasa de Supervivencia , Grado de Desobstrucción Vascular
20.
Circulation ; 106(13): 1672-7, 2002 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-12270861

RESUMEN

BACKGROUND: No-reflow associated with direct angioplasty (PCI) of patients with acute coronary syndromes (ACS) is associated with unfavorable results. METHODS AND RESULTS: We used a new thrombectomy device to treat 51 lesions in 48 consecutive ACS patients (40 male and 8 female; mean age 63 years) and conducted a microscopic analysis of aspirates and blood samples retrieved from the culprit coronary artery. The first aspirate was collected before PCI and the second was collected separately after percutaneous transluminal coronary angioplasty or stenting, including samples from the no-reflow lumen. Light microscopy showed that the materials obtained from the pre-PCI aspiration consisted of thrombus in 37.5%, thrombus and atheroma in 35.0%, and atheromatous plaque in 27.5%. The materials collected from the post-PCI aspiration were thrombus in 8.3%, thrombus and atheroma in 41.7%, and atheromatous plaque in 50.0%. We then compared the 9 lesions (19.1%) with no-reflow to those without no-reflow. There was no difference in the pre-PCI aspirates. However, after PCI, there was more atheromatous plaque retrieved from patients with no-reflow (P<0.001) as well as significantly more platelet and fibrin complex, macrophages, and cholesterol crystals in the blood aspirated from no-reflow cases. Aspiration of these elements improved the no-reflow in 7 of 9 lesions to TIMI-3 flow. CONCLUSIONS: No-reflow after angioplasty may be caused by gruel that formed from an atheroma attributable to mechanical plaque disruption during intervention.


Asunto(s)
Arteriosclerosis/fisiopatología , Circulación Coronaria , Enfermedad Coronaria/fisiopatología , Vasos Coronarios/fisiopatología , Trombosis/fisiopatología , Enfermedad Aguda , Angioplastia Coronaria con Balón/efectos adversos , Arteriosclerosis/complicaciones , Arteriosclerosis/patología , Velocidad del Flujo Sanguíneo , Implantación de Prótesis Vascular/efectos adversos , Cateterismo/instrumentación , Angiografía Coronaria , Enfermedad Coronaria/complicaciones , Enfermedad Coronaria/diagnóstico , Enfermedad Coronaria/cirugía , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Stents , Trombectomía/instrumentación , Trombosis/patología , Trombosis/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA