1.
HNO ; 60(9): 807-13, 2012 Sep.
Artículo en Alemán | MEDLINE | ID: mdl-22767192

RESUMEN

PROBLEM DESCRIPTION: Nowadays all procedures in tympanoplasty are performed using conventional instrumentation without any mechatronic based manipulators. A micromanipulator system (MMS) holds microinstruments and transmits the surgeon's hand movements to a monitor, thus, improving precision and ergonomics. MATERIALS AND METHODS: Using the Cartesian principle, a telemanipulator with three linear degrees of freedom controlled with a joystick was designed. The three axes are powered by a servomotor. The manipulator is equipped with a sterilizable instrument holder, which is placed on a sterile covered system. On this instrument holder, sterile surgical instruments can be clipped and can be easily changed during surgery. In the scope of this study, the MMS was used to perform a tympanoplasty III in 20 patients. A workflow expert protocol, a video of the surgery, and a questionnaire completed by all surgeons were evaluated. RESULTS: Clinical use of the MMS 2.0 was performed in all 20 patients as planned. A partial/total ossicular replacement prosthesis (PORP/TORP) was used in all cases with the MMS as planned. Significantly more time was necessary not only to prepare for surgery but also to prepare the equipment intraoperatively, and the incision to suture time was longer. The number of intraoperative changes of instruments decreased by 24%. The frequency of contact between the instrument and the prosthesis was significantly decreased. All questionnaires indicated that further improvement of the MMS is needed. CONCLUSION: The manipulator MMS 2.0 was successfully used in the clinical setting for the first time. The tool offers great potential for middle ear surgery (e.g., tympanoplasty III, stapes surgery and cochlear implant insertion). The principal of telemanipulation (master-slave) could be transferred to middle ear surgery. However, numerous technical improvements are still required.


Asunto(s)
Micromanipulación/instrumentación , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Cirugía Asistida por Computador/métodos , Timpanoplastia/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Proyectos Piloto
2.
Laryngorhinootologie ; 90(6): 353-7, 2011 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-21614736

RESUMEN

BACKGROUND: With the application of optical navigation systems an interruption of the line of sight (LOS) between navigation camera and the patient/instrument can occur. The goal of this work is the clinical evaluation of a newly developed system for automatic adjusting of an optical navigation camera (Navigation Camera Assistant, NCA). NCA is a miniature robot, which is able to position the navigation camera autonomously in 2 levels. MATERIAL AND METHODS: The influence of the NCA was examined on 128 patients: 55 procedures at the paranasal sinuses and 9 procedures at the temporal bone with the NCA were evaluated and compared with available workflow data of adequate surgeries without NCA. An optical navigation system of the 3 (rd) generation was used. The following parameters were recorded: Preparation time of the system, time of using the system, LOS-interruptions. RESULTS: The LOS-interruption decreased in the group of FESS with application of the NCA by 92%, in the group tympanic cavity by 85%. The number of corrective motions of the navigation camera was increased with application of the NCA in the group FESS by 73%, in the group tympanic cavity by 89%. The usage time of navigation increased with the application of the NCA in the group of FESS by 36%, in the group tympanic cavity by 16%. CONCLUSIONS: With a motorized navigation camera can be the interruption rate of LOS significantly improved at frontal and lateral skull base. The technical expenditure for installation of the NCA robot is little even during, for this reason there is the potential that this module can be established for the clinical practice.


Asunto(s)
Endoscopios , Procedimientos Quirúrgicos Otorrinolaringológicos/instrumentación , Fotograbar/instrumentación , Robótica/instrumentación , Cirugía Asistida por Computador/instrumentación , Flujo de Trabajo , Diseño de Equipo , Humanos , Enfermedades de los Senos Paranasales/cirugía , Base del Cráneo/cirugía , Hueso Temporal/cirugía
3.
Fortschr Neurol Psychiatr ; 77(7): 407-11, 2009 Jul.
Artículo en Alemán | MEDLINE | ID: mdl-19582652

RESUMEN

The diagnosis of Alzheimer's dementia is currently changing from a late and exclusion diagnosis towards a pathophysiology-based early and positive diagnosis. Especially advances in neuro-chemical dementia diagnostics in the cerebrospinal fluid (NDD-CSF) and imaging techniques like PET, SPECT or MRI are of particular interest. Unfortunately, many studies investigated only either one or other technique. In the present study 56 patients (average 67.1 years; average mini-mental status test (MMST) 22.2) were examined with the clinical diagnosis of Alzheimer's dementia. All patients both underwent NDD-CSF as well as 99mTc-SPECT. Only the SPECT, but not the NDD-CSF correlated with disease severity. Sensitivity of NDD-CSF was 89 % and SPECT 48 % for all patients and 93 % resp. 61 % for patients with MMST < 24. Below MMST 20 both methods had equal sensitivity. Both diagnostic techniques showed no statistic coherence (p = 0.27), neither after correction for subgroups like disease severity or the APOE genotype. Our results are compatible with the hypothesis that the NDD-CSF reflects beta-amyloid-aggregation and Tau-Protein pathology as a pathophysiologic biomarker. Our results suggest that SPECT is rather a state parameter for the rCBF changes following cortical neurodegeneration.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/diagnóstico , Demencia/líquido cefalorraquídeo , Demencia/diagnóstico , Anciano , Péptidos beta-Amiloides/metabolismo , Amiloidosis/metabolismo , Amiloidosis/patología , Apolipoproteínas E/genética , Corteza Cerebral/patología , Femenino , Genotipo , Humanos , Masculino , Pruebas Neuropsicológicas , Reproducibilidad de los Resultados , Tecnecio , Tomografía Computarizada de Emisión de Fotón Único , Proteínas tau/metabolismo