1.
Sensors (Basel) ; 19(4)2019 Feb 13.
Artículo en Inglés | MEDLINE | ID: mdl-30781777

RESUMEN

This paper presents the design and fabrication process of a spherical-omnidirectional ultrasound transducer for underwater sensor network applications. The transducer is based on the vibration of two hemispheres with a thickness of 1 mm and an outer diameter of 10 mm, which are actuated by two piezoelectric ring elements. Since the ultrasound wave is generated by the vibration of the two hemispheres, a matching layer is not required. Silicon Carbide (SiC) is used as the material of the hemispherical shells of the transducer. The shells were fabricated by laser sintering as an additive manufacturing method, in which the hemispheres were built layer by layer from a powder bed. All manufactured transducers with an outer dimension of 10 × 14.2 mm and a center frequency of 155 kHz were measured in a water tank by a hydrophone or in mutual communication. The circumferential source level was measured to vary less than 5dB. The power consumption and the insertion loss of the transducer, ranging from 100 µ W to 2.4 mW and 21.2 dB, respectively, along with all other measurements, prove that the transducer can transmit and receive ultrasound waves omnidirectionally at tens of centimeters intervals with a decent power consumption and low actuation voltage.

2.
MethodsX ; 7: 101122, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33318953

RESUMEN

Surface topography measurements are vital in industrial quality control. Linear roughness measurements are among the most preferred methods, being quick to perform and easy to interpret. The ISO 16610 standard series prescribes filters that can be used for most cases, but has limitations for restricted measurement lengths. This is because the standard filter type is a Gaussian filter, which like most instances of kernel convolution filters has no output near the edges of the profile, effectively shortening the length of the filtered output profile as compared to the input. In some cases, this leads to a lack of representative data after filtration. Especially in fields such as Additive Manufacturing (AM) this becomes a problem, due to the high "roughness to measurable data length"-ratio that characterizes complex AM parts. This paper describes a method that allows to overcome this limitation:•A method for circular padding of short measured tracks is described and validated.•A flexible profile data post-processing tool was developed in MATLAB to grant users more control over the data analysis. Results obtained from roughness profiles long enough for normal ISO procedures are shown to not change significantly when circularly padded. When only a shorter section of the data is available, where the standard protocol would not be able to compute a filtered profile and related parameters anymore, the circular padding method is shown to lead to results that are in good agreement with the ISO standard procedures.

3.
Sci Rep ; 10(1): 10523, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32601438

RESUMEN

This work demonstrates a successful in situ method capable of producing an ultra-strong novel Ti composite without aluminium and vanadium. In this method, selective laser melting is used to conduct in situ alloying and reinforcing of a Ti/10.5 wt% Mo2C powder mixture. It is shown that this leads to a metastable ß-Ti matrix homogeneously reinforced by high aspect ratio, 50-200 nm wide and up to several micrometre long TiC whiskers. The transformations of the phases are controlled by decomposition, dissolution, diffusion, and reformation of constituents. The whisker morphology of in situ formed TiC particles is associated with directional crystal growth along the TiC<110> direction. The developed TiC reinforced ß-Ti alloy combines a hardness over 500 HV, a Young's modulus of 126 GPa, and an ultimate compressive strength of 1642 MPa. Improving the ductility of this composite is the subject of another work.

4.
Materials (Basel) ; 12(15)2019 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-31382542

RESUMEN

The addition of 0.1 wt % carbon nanoparticles significantly improved the optical absorption and flowability of gas-atomized copper powder. This facilitated selective laser melting (SLM) by reducing the required laser energy density to obtain 98% dense parts. Moreover, the carbon addition led to an in situ de-oxidation of the copper parts during the SLM process. The properties of the as-built copper parts were limited to a tensile strength of 125 MPa, a ductility of 3%, and an electrical conductivity of 22.7 × 106 S/m, despite the advantageous effect of carbon on the powder characteristics and SLM behavior. The modest mechanical properties were associated with the segregation of carbon nanoparticles and other impurities, such as phosphorus and oxygen along grain boundaries of epitaxially grown grains. Whereas, the low electrical conductivity was mainly attributed to the phosphorus impurity in solid-solution with copper.

5.
Acta Biomater ; 47: 193-202, 2017 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-27717912

RESUMEN

This paper provides new insights into the fatigue properties of porous metallic biomaterials produced by additive manufacturing. Cylindrical porous samples with diamond unit cells were produced from Ti6Al4V powder using Selective Laser Melting (SLM). After measuring all morphological and quasi-static properties, compression-compression fatigue tests were performed to determine fatigue strength and to identify important fatigue influencing factors. In a next step, post-SLM treatments were used to improve the fatigue life of these biomaterials by changing the microstructure and by reducing stress concentrators and surface roughness. In particular, the influence of stress relieving, hot isostatic pressing and chemical etching was studied. Analytical and numerical techniques were developed to calculate the maximum local tensile stress in the struts as function of the strut diameter and load. With this method, the variability in the relative density between all samples was taken into account. The local stress in the struts was then used to quantify the exact influence of the applied post-SLM treatments on the fatigue life. A significant improvement of the fatigue life was achieved. Also, the post-SLM treatments, procedures and calculation methods can be applied to different types of porous metallic structures and hence this paper provides useful tools for improving fatigue performance of metallic biomaterials. STATEMENT OF SIGNIFICANCE: Additive Manufacturing (AM) techniques such as Selective Laser Melting (SLM) are increasingly being used for producing customized porous metallic biomaterials. These biomaterials are regularly used for biomedical implants and hence a long lifetime is required. In this paper, a set of post-built surface and heat treatments is presented that can be used to significantly improve the fatigue life of porous SLM-Ti6Al4V samples. In addition, a novel and efficient analytical local stress method was developed to accurately quantify the influence of the post-built treatments on the fatigue life. Also numerical simulation techniques were used for validation. The developed methods and techniques can be applied to other types of porous biomaterials and hence provide new and useful tools for improving and predicting the fatigue life of porous biomaterials.


Asunto(s)
Materiales Biocompatibles/química , Rayos Láser , Ensayo de Materiales/métodos , Metales/química , Estrés Mecánico , Aleaciones , Microscopía Electrónica de Rastreo , Porosidad , Titanio/química
6.
Acta Biomater ; 14: 217-25, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25500631

RESUMEN

The medical device industry's interest in open porous, metallic biomaterials has increased in response to additive manufacturing techniques enabling the production of complex shapes that cannot be produced with conventional techniques. Tantalum is an important metal for medical devices because of its good biocompatibility. In this study selective laser melting technology was used for the first time to manufacture highly porous pure tantalum implants with fully interconnected open pores. The architecture of the porous structure in combination with the material properties of tantalum result in mechanical properties close to those of human bone and allow for bone ingrowth. The bone regeneration performance of the porous tantalum was evaluated in vivo using an orthotopic load-bearing bone defect model in the rat femur. After 12 weeks, substantial bone ingrowth, good quality of the regenerated bone and a strong, functional implant-bone interface connection were observed. Compared to identical porous Ti-6Al-4V structures, laser-melted tantalum shows excellent osteoconductive properties, has a higher normalized fatigue strength and allows for more plastic deformation due to its high ductility. It is therefore concluded that this is a first step towards a new generation of open porous tantalum implants manufactured using selective laser melting.


Asunto(s)
Prótesis e Implantes , Tantalio/farmacología , Animales , Línea Celular , Fuerza Compresiva/efectos de los fármacos , Fémur/diagnóstico por imagen , Fémur/efectos de los fármacos , Humanos , Rayos Láser , Masculino , Ratones , Microscopía Electrónica de Rastreo , Porosidad , Radiografía , Ratas Wistar , Torsión Mecánica
7.
Mater Sci Eng C Mater Biol Appl ; 54: 94-100, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26046272

RESUMEN

Additive manufacturing techniques are getting more and more established as reliable methods for producing porous metal implants thanks to the almost full geometrical and mechanical control of the designed porous biomaterial. Today, Ti6Al4V ELI is still the most widely used material for porous implants, and none or little interest goes to pure titanium for use in orthopedic or load-bearing implants. Given the special mechanical behavior of cellular structures and the material properties inherent to the additive manufacturing of metals, the aim of this study is to investigate the properties of selective laser melted pure unalloyed titanium porous structures. Therefore, the static and dynamic compressive properties of pure titanium structures are determined and compared to previously reported results for identical structures made from Ti6Al4V ELI and tantalum. The results show that porous Ti6Al4V ELI still remains the strongest material for statically loaded applications, whereas pure titanium has a mechanical behavior similar to tantalum and is the material of choice for cyclically loaded porous implants. These findings are considered to be important for future implant developments since it announces a potential revival of the use of pure titanium for additively manufactured porous implants.


Asunto(s)
Prótesis e Implantes , Titanio/química , Aleaciones , Materiales Biocompatibles/química , Fuerza Compresiva , Rayos Láser , Ensayo de Materiales , Porosidad , Propiedades de Superficie , Tantalio/química , Soporte de Peso
8.
Mater Sci Eng C Mater Biol Appl ; 33(6): 3404-12, 2013 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-23706227

RESUMEN

In the present study a structural characterization and in vitro cell-biological evaluation was performed on polycaprolactone (PCL) scaffolds that were produced by the additive manufacturing technique selective laser sintering (SLS), followed by a plasma-based surface modification technique, either non-thermal oxygen plasma or double protein coating, to functionalize the PCL scaffold surfaces. In the first part of this study pore morphology by means of 2D optical microscopy, surface chemistry by means of hydrophilicity measurement and X-ray photoelectron spectroscopy, strut surface roughness by means of 3D micro-computed tomography (CT) imaging and scaffold mechanical properties by means of compression testing were evaluated before and after the surface modifications. The results showed that both surface modifications increased the PCL scaffold hydrophilicity without altering the morphological and mechanical properties. In the second part of this study the in vitro cell proliferation and differentiation of human osteoprogenitor cells, over 14 days of culture in osteogenic and growth medium were investigated. The O2 plasma modification gave rise to a significant lower in vitro cell proliferation compared to the untreated and double protein coated scaffolds. Furthermore the double protein coating increased in vitro cell metabolic activity and cell differentiation compared to the untreated and O2 plasma PCL scaffolds when OM was used.


Asunto(s)
Poliésteres/química , Fosfatasa Alcalina/metabolismo , Regeneración Ósea , Diferenciación Celular , Proliferación Celular , Células Cultivadas , Humanos , Rayos Láser , Osteogénesis , Células Madre/citología , Células Madre/metabolismo , Ingeniería de Tejidos , Andamios del Tejido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA