Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Vasc Endovasc Surg ; 64(4): 377-386, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35667596

RESUMEN

OBJECTIVE: Reflux within the superficial microvenous network may play a critical role in the development of skin changes which can be associated with chronic venous insufficiency. This study aimed to determine if near infrared fluorescence (NIRF) imaging could be used to accurately determine superficial venous reflux in the leg. METHODS: A total of nine limbs were examined ex vivo from patients undergoing limb amputation for peripheral arterial disease. Cannulation of the distal great saphenous vein was used to sequentially perform Xray contrast enhanced venography, NIRF imaging, and venous corrosion casts. RESULTS: Fluorescence imaging visualised a range of different microvenous reflux patterns ex vivo, which were generally not evident by Xray venography but were consistent with retrograde resin vascular casts. These included both focal and diffuse regions of fluorescence within the skin and, consistent with previous observations, the vascular casts indicated that regions of venous reflux were typically associated with incompetent valves. CONCLUSION: The findings from this study suggest a potential method for investigating early stage superficial venous disease, prior to the appearance of visible signs of advanced venous disease, such as skin changes. However, further studies are required to confirm the in vivo clinical utility of these observations.


Asunto(s)
Pierna , Insuficiencia Venosa , Humanos , Pierna/irrigación sanguínea , Vena Safena/diagnóstico por imagen , Vena Femoral , Imagen Óptica
2.
Eur J Vasc Endovasc Surg ; 60(4): 594-601, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32753305

RESUMEN

OBJECTIVE: Past studies have suggested a potential "J shaped" relationship between infrarenal aortic diameter and both cardiovascular disease (CVD) prevalence and all cause mortality. However, screening programmes have focused primarily on large (aneurysmal) aortas. In addition, aortic diameter is rarely adjusted for body size, which is particularly important for women. This study aimed to investigate specifically the relationship between body size adjusted infrarenal aortic diameter and baseline prevalence of CVD. METHODS: A retrospective analysis was performed on a total of 4882 elderly (>50 years) participants (mean age 69.4 ± 8.9 years) for whom duplex ultrasound to assess infrarenal abdominal aortic diameters had been performed. History of CVDs, including ischaemic heart disease (IHD), and associated risk factors were collected at the time of assessment. A derivation cohort of 1668 participants was used to select cut offs at the lower and upper 12.5% tails of the aortic size distributions (aortic size index of <0.84 and >1.2, respectively), which was then tested in a separate cohort. RESULTS: A significantly elevated prevalence of CVD, and specifically IHD, was observed in participants with both small and large aortas. These associations remained significant following adjustment for age, sex, diabetes, hypertension, dyslipidaemia, obesity (body mass index), and smoking. CONCLUSION: The largest and smallest infrarenal aortic sizes were both associated with prevalence of IHD. In addition to identifying those with aneurysmal disease, it is hypothesised that screening programmes examining infrarenal aortic size may also have the potential to improve global CVD risk prediction by identifying those with small aortas.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Isquemia Miocárdica/epidemiología , Ultrasonografía Doppler Dúplex , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/diagnóstico por imagen , Nueva Zelanda/epidemiología , Valor Predictivo de las Pruebas , Prevalencia , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
3.
Vasc Endovascular Surg ; : 15385744221108052, 2022 Jun 09.
Artículo en Inglés | MEDLINE | ID: mdl-35680567

RESUMEN

OBJECTIVES: To determine the association between suprarenal aortic diameters and complications that may be attributed to a dilating phenotype following endovascular abdominal aortic aneurysm repair. DESIGN: This study is a retrospective review. METHODS: We measured the abdominal aortas of 147 consecutive patients with a mean age of 78.5 (range 60-93) years, who had a mean Endovascular aneurysm repair (EVAR) follow-up of 3 years (6 months to 8 years) at a public Hospital. Aortic calibres measured 5 mm above the highest renal artery were recorded, patients were categorised according to suprarenal diameter; Group A: greater than 25 mm, Group B: less than or equal to 25 mm. Stent migration, aneurysmal sac growth, presence of an endoleak and its type, occlusion events, rupture, interventions and mortality, as well as clinical history and demographic data were compared between groups. RESULTS: There was a significantly higher occurrence of stent migration (11% v 0%; P = .01) in patients with larger suprarenal aortas (Group A). The occurrence of any endoleak did not differ between the groups, however, significantly more complications resulting in secondary intervention, excluding occlusions, were noted in Group A (34% vs 17%, P = .04). CONCLUSIONS: The results from this study suggest that patients with above-average suprarenal diameters (categorised as dilators) may have a higher occurrence of specific complications following EVAR. A more detailed study to establish the association of suprarenal calibre with types of complications following EVAR is warranted.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA