Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Infect Chemother ; 22(6): 421-3, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26846458

RESUMEN

We report an immunocompromised child who experienced two episodes of bacteremia due to Streptococcus pyogenes. Random amplification of polymorphic DNA profiles, emm genotypes, superantigen profiles, antimicrobial susceptibility, and resistance-related genes were investigated, and the results showed different profiles between the two isolates. This is the first report describing recurrent bacteremia caused by different strains of S. pyogenes.


Asunto(s)
Bacteriemia/microbiología , Huésped Inmunocomprometido , Infecciones Estreptocócicas/microbiología , Streptococcus pyogenes , Bacteriemia/inmunología , Preescolar , Humanos , Pierna , Masculino , Pruebas de Sensibilidad Microbiana , Recurrencia , Especificidad de la Especie , Infecciones Estreptocócicas/inmunología , Streptococcus pyogenes/efectos de los fármacos , Streptococcus pyogenes/inmunología
2.
Kyobu Geka ; 66(10): 876-81, 2013 Sep.
Artículo en Japonés | MEDLINE | ID: mdl-24008635

RESUMEN

Our modification of Starnes' procedure reduces right ventricular volume using only "suture plication" to improve surgical outcomes. However, shunt size in the procedure varies widely between patients. As this may be related to small lung volume, we estimated lung volume in each patient using computed tomography (CT).Since 2007, we have performed Starnes' procedure in 4 patients. Preoperative cardiothoracic ratio was 89±4.5%. Age and body weight at operation were 4.3±2.6 days and 2.6±0.2 kg, respectively. Anatomic slices 3 mm thick were acquired in transverse planes by CT. Total lung volume was calculated by accumulating those slices. Total lung volume and lung volume/body weight were 97.2±34.1 ml, 36.8±11.5 ml/kg, respectively. In one patient, a 3 mm prosthetic graft was needed to place a clip to regulate blood flow. Another patient required an additional shunt. The patient with the smallest lung volume required treatment with an extracorporeal lung-assistance device. Chest X-rays of neonates with severe Ebstein's anomaly usually show a "wall-to-wall" heart. However, lung volume varies widely between patients. Estimation of lung volume using CT is useful. In patients with smaller lung volume, a larger shunt than usual may be required to obtain the necessary pulmonary blood flow.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/métodos , Anomalía de Ebstein/cirugía , Mediciones del Volumen Pulmonar , Pulmón/irrigación sanguínea , Femenino , Humanos , Recién Nacido , Pulmón/diagnóstico por imagen , Masculino , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA