Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Med Sci Monit ; 25: 3316-3320, 2019 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-31055590

RESUMEN

BACKGROUND Catheter radiofrequency ablation for typical atrial flutter is considered to be safe and effective. However, atrial fibrillation (AF) following cavotricuspid isthmus ablation for atrial flutter has been reported in patients without a previous history of AF, which has implications for the decision to use oral anticoagulation. This retrospective study at a single center aimed to evaluate the occurrence of AF in patients after successful cavotricuspid isthmus ablation of typical atrial flutter and to determine the incidence and associations with AF during follow-up. MATERIAL AND METHODS Between January 2011 and July 2017, of 110 consecutive patients who underwent cavotricuspid isthmus ablation for typical atrial flutter, 67 patients had no previous history of AF, of which 40 patients underwent follow-up. The 40 patients included in this retrospective clinical study included 34 men and 6 women, with a mean age of 67±10 years. RESULTS Forty patients underwent post-ablation follow-up for 46±23 months, and 12 patients (30%) developed AF; six patients (15%) experienced recurrent of atrial flutter. More than half of the patients with post-ablation AF were asymptomatic with a European Heart Rhythm Association (EHRA) score of 1, and univariate analysis showed the absence of variables associated with the prevalence of AF. CONCLUSIONS Following cavotricuspid isthmus ablation for atrial flutter, recurrence of atrial flutter was found in 15% of cases, and asymptomatic AF occurred in 30%. These findings have implications for the use of post-ablation oral anticoagulation treatment, which is often discontinued following ablation therapy and before patient follow-up.


Asunto(s)
Fibrilación Atrial/etiología , Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Válvula Tricúspide/cirugía , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
2.
J Electrocardiol ; 57S: S34-S39, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31526572

RESUMEN

BACKGROUND: The clinical effectiveness of primary prevention implantable cardioverter defibrillator (ICD) therapy is under debate. It is urgently needed to better identify patients who benefit from prophylactic ICD therapy. The EUropean Comparative Effectiveness Research to Assess the Use of Primary ProphylacTic Implantable Cardioverter Defibrillators (EU-CERT-ICD) completed in 2019 will assess this issue. SUMMARY: The EU-CERT-ICD is a prospective investigator-initiated non-randomized, controlled, multicenter observational cohort study done in 44 centers across 15 European countries. A total of 2327 patients with heart failure due to ischemic heart disease or dilated cardiomyopathy indicated for primary prophylactic ICD implantation were recruited between 2014 and 2018 (>1500 patients at first ICD implantation, >750 patients non-randomized non-ICD control group). The primary endpoint was all-cause mortality, and first appropriate shock was co-primary endpoint. At baseline, all patients underwent 12­lead ECG and Holter-ECG analysis using multiple advanced methods for risk stratification as well as documentation of clinical characteristics and laboratory values. The EU-CERT-ICD data will provide much needed information on the survival benefit of preventive ICD therapy and expand on previous prospective risk stratification studies which showed very good applicability of clinical parameters and advanced risk stratifiers in order to define patient subgroups with above or below average ICD benefit. CONCLUSION: The EU-CERT-ICD study will provide new and current data about effectiveness of primary prophylactic ICD implantation. The study also aims for improved risk stratification and patient selection using clinical risk markers in general, and advanced ECG risk markers in particular.


Asunto(s)
Investigación sobre la Eficacia Comparativa , Muerte Súbita Cardíaca , Desfibriladores Implantables , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Europa (Continente) , Humanos , Estudios Multicéntricos como Asunto , Estudios Observacionales como Asunto , Estudios Prospectivos , Resultado del Tratamiento
3.
J Interv Card Electrophysiol ; 60(1): 109-114, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32103404

RESUMEN

PURPOSE: Eight-millimeter-tip ablation catheters are characterized by poor mapping resolution as they depend on electrode size and spacing. IntellaTip MiFi XP 8-mm (Boston Scientific) catheters offer high mapping resolution due to 3 mini-electrodes (ME) located at the distal tip of the catheter and are dedicated for cavo-tricuspid isthmus (CTI) radiofrequency ablation (RFA). The aim of the study was to evaluate the usefulness, effectiveness and safety of novel IntellaTip MiFi XP catheter for CTI RFA and its ability to localize anatomical structures of the heart. METHODS: The study included 10 patients referred for atrial flutter ablation. The 3D mapping system EnSite Velocity was utilized for catheter visualization. The ME signals were used for tricuspid annulus visualization, RF delivery effectiveness assessment defined as ME signal attenuation, and localization of the gaps in the ablation line. The use of ME signals for TV annulus localization resulted in a 13.9 mm (35.5 ± 4.8 mm vs 49.4 ± 7.8 mm; p < 0.01) shorter ablation line in comparison with the potential ablation line designed using standard bipol. The ablation endpoint, bidirectional block, was achieved in all 10 cases (100%) and lasted for at least 15 min after the last RF delivery. The ablation endpoint was reached after 5.1 ± 1.67 RF applications. The total RF time was 220 ± 61 s. Total procedure time was 66 ± 13.5 min, fluoroscopy time 3.92 ± 4.21 min, and total fluoroscopy dose 40.3 ± 56.5 mGy. RESULTS: In 3 out of 10 cases, there was a need of filling the gap with 1-2 additional applications after the first linear lesion set. No additional RF applications were required at the annular end of the ablation line. The indirect comparison with previously conducted studies using a standard 8-mm ablation catheter shows that the studied catheter has at least the same or even better performance. CONCLUSIONS: The use of the novel IntellaTip MiFi XP may help to avoid unnecessary RF application especially at the annular part of cavo-tricuspid isthmus and enables a purely electrophysiological approach to atrial flutter ablation, as high-resolution ME signals help to understand local electrophysiological phenomena.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Aleteo Atrial/diagnóstico por imagen , Aleteo Atrial/cirugía , Catéteres , Electrodos , Diseño de Equipo , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA