Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Mol Cell ; 49(4): 583-90, 2013 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-23438854

RESUMEN

High-resolution mass spectrometry (MS)-based proteomics has progressed tremendously over the years. For model organisms like yeast, we can now quantify complete proteomes in just a few hours. Developments discussed in this Perspective will soon enable complete proteome analysis of mammalian cells, as well, with profound impact on biology and biomedicine.


Asunto(s)
Proteínas Fúngicas/análisis , Proteoma/análisis , Levaduras/química , Animales , Células Cultivadas , Biología Computacional , Proteínas Fúngicas/química , Proteínas Fúngicas/aislamiento & purificación , Humanos , Espectrometría de Masas , Proteoma/química , Proteoma/aislamiento & purificación , Proteómica
2.
Mol Cell Proteomics ; 16(4): 694-705, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28126900

RESUMEN

Recent advances in mass spectrometry (MS)-based proteomics now allow very deep coverage of cellular proteomes. To achieve near-comprehensive identification and quantification, the combination of a first HPLC-based peptide fractionation orthogonal to the on-line LC-MS/MS step has proven to be particularly powerful. This first dimension is typically performed with milliliter/min flow and relatively large column inner diameters, which allow efficient pre-fractionation but typically require peptide amounts in the milligram range. Here, we describe a novel approach termed "spider fractionator" in which the post-column flow of a nanobore chromatography system enters an eight-port flow-selector rotor valve. The valve switches the flow into different flow channels at constant time intervals, such as every 90 s. Each flow channel collects the fractions into autosampler vials of the LC-MS/MS system. Employing a freely configurable collection mechanism, samples are concatenated in a loss-less manner into 2-96 fractions, with efficient peak separation. The combination of eight fractions with 100 min gradients yields very deep coverage at reasonable measurement time, and other parameters can be chosen for even more rapid or for extremely deep measurements. We demonstrate excellent sensitivity by decreasing sample amounts from 100 µg into the sub-microgram range, without losses attributable to the spider fractionator and while quantifying close to 10,000 proteins. Finally, we apply the system to the rapid automated and in-depth characterization of 12 different human cell lines to a median depth of 11,472 different proteins, which revealed differences recapitulating their developmental origin and differentiation status. The fractionation technology described here is flexible, easy to use, and facilitates comprehensive proteome characterization with minimal sample requirements.


Asunto(s)
Fraccionamiento Químico/instrumentación , Péptidos/química , Proteómica/métodos , Fraccionamiento Químico/métodos , Cromatografía Líquida de Alta Presión , Células HeLa , Humanos , Proteómica/instrumentación , Espectrometría de Masas en Tándem
3.
Nat Methods ; 11(3): 319-24, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24487582

RESUMEN

Mass spectrometry (MS)-based proteomics typically employs multistep sample-preparation workflows that are subject to sample contamination and loss. We report an in-StageTip method for performing sample processing, from cell lysis through elution of purified peptides, in a single, enclosed volume. This robust and scalable method largely eliminates contamination or loss. Peptides can be eluted in several fractions or in one step for single-run proteome analysis. In one day, we obtained the largest proteome coverage to date for budding and fission yeast, and found that protein copy numbers in these cells were highly correlated (R(2) = 0.78). Applying the in-StageTip method to quadruplicate measurements of a human cell line, we obtained copy-number estimates for 9,667 human proteins and observed excellent quantitative reproducibility between replicates (R(2) = 0.97). The in-StageTip method is straightforward and generally applicable in biological or clinical applications.


Asunto(s)
Células Eucariotas/metabolismo , Dosificación de Gen/genética , Proteómica/métodos , Contaminación de ADN , Células HeLa , Humanos , Reproducibilidad de los Resultados , Proteínas de Saccharomyces cerevisiae/genética
4.
Mol Cell Proteomics ; 14(7): 2030-41, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25887394

RESUMEN

The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigation of many conditions or perturbations puts a strain on measurement capacity. Here, we develop a high-throughput workflow capable of dealing with large numbers of low or medium complexity samples and specifically aim at the analysis of 96-well plates in a single day (15 min per sample). We combine parallel sample processing with a modified liquid chromatography platform driving two analytical columns in tandem, which are coupled to a quadrupole Orbitrap mass spectrometer (Q Exactive HF). The modified LC platform eliminates idle time between measurements, and the high sequencing speed of the Q Exactive HF reduces required measurement time. We apply the pipeline to the yeast chromatin remodeling landscape and demonstrate quantification of 96 pull-downs of chromatin complexes in about 1 day. This is achieved with only 500 µg input material, enabling yeast cultivation in a 96-well format. Our system retrieved known complex-members and the high throughput allowed probing with many bait proteins. Even alternative complex compositions were detectable in these very short gradients. Thus, sample throughput, sensitivity and LC/MS-MS duty cycle are improved severalfold compared with established workflows. The pipeline can be extended to different types of interaction studies and to other medium complexity proteomes.


Asunto(s)
Cromatografía Liquida/métodos , Mapeo de Interacción de Proteínas/métodos , Saccharomyces cerevisiae/metabolismo , Espectrometría de Masas en Tándem/métodos , Ensamble y Desensamble de Cromatina , Cromatografía Líquida de Alta Presión , Reproducibilidad de los Resultados , Proteínas de Saccharomyces cerevisiae/metabolismo , Factores de Tiempo
5.
Mol Cell Proteomics ; 14(7): 2014-29, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25991688

RESUMEN

Hybrid quadrupole time-of-flight (QTOF) mass spectrometry is one of the two major principles used in proteomics. Although based on simple fundamentals, it has over the last decades greatly evolved in terms of achievable resolution, mass accuracy, and dynamic range. The Bruker impact platform of QTOF instruments takes advantage of these developments and here we develop and evaluate the impact II for shotgun proteomics applications. Adaption of our heated liquid chromatography system achieved very narrow peptide elution peaks. The impact II is equipped with a new collision cell with both axial and radial ion ejection, more than doubling ion extraction at high tandem MS frequencies. The new reflectron and detector improve resolving power compared with the previous model up to 80%, i.e. to 40,000 at m/z 1222. We analyzed the ion current from the inlet capillary and found very high transmission (>80%) up to the collision cell. Simulation and measurement indicated 60% transfer into the flight tube. We adapted MaxQuant for QTOF data, improving absolute average mass deviations to better than 1.45 ppm. More than 4800 proteins can be identified in a single run of HeLa digest in a 90 min gradient. The workflow achieved high technical reproducibility (R2 > 0.99) and accurate fold change determination in spike-in experiments in complex mixtures. Using label-free quantification we rapidly quantified haploid against diploid yeast and characterized overall proteome differences in mouse cell lines originating from different tissues. Finally, after high pH reversed-phase fractionation we identified 9515 proteins in a triplicate measurement of HeLa peptide mixture and 11,257 proteins in single measurements of cerebellum-the highest proteome coverage reported with a QTOF instrument so far.


Asunto(s)
Proteómica/instrumentación , Proteómica/métodos , Animales , Línea Celular , Cromatografía Liquida , Diploidia , Haploidia , Células HeLa , Humanos , Concentración de Iones de Hidrógeno , Iones , Espectrometría de Masas , Ratones , Peso Molecular , Péptidos/metabolismo , Proteoma/metabolismo , Reproducibilidad de los Resultados , Saccharomyces cerevisiae/metabolismo , Factores de Tiempo
6.
Front Pharmacol ; 9: 699, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30022949

RESUMEN

Idiosyncratic drug-induced liver injury (iDILI) is a major cause of acute liver failure resulting in liver transplantation or death. Prediction and diagnosis of iDILI remain a great challenge, as current models provide unsatisfying results in terms of sensitivity, specificity, and prognostic value. The absence of appropriate tools for iDILI detection also impairs the development of reliable biomarkers. Here, we report on a new method for identification of drug-specific biomarkers. We combined the advantages of monocyte-derived hepatocyte-like (MH) cells, able to mimic individual characteristics, with those of a novel mass spectrometry-based proteomics technology to assess potential biomarkers for Diclofenac-induced DILI. We found over 2,700 proteins differentially regulated in MH cells derived from individual patients. Herefrom, we identified integrin beta 3 (ITGB3) to be specifically upregulated in Diclofenac-treated MH cells from Diclofenac-DILI patients compared to control groups. Finally, we validated ITGB3 by flow cytometry analysis of whole blood and histological staining of liver biopsies derived from patients diagnosed with Diclofenac-DILI. In summary, our results show that biomarker candidates can be identified by proteomics analysis of MH cells. Application of this method to a broader range of drugs in the future will exploit its full potential for the development of drug-specific biomarkers. Data are available via ProteomeXchange with identifier PXD008918.

7.
Cell Syst ; 2(3): 185-95, 2016 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-27135364

RESUMEN

Proteins in the circulatory system mirror an individual's physiology. In daily clinical practice, protein levels are generally determined using single-protein immunoassays. High-throughput, quantitative analysis using mass-spectrometry-based proteomics of blood, plasma, and serum would be advantageous but is challenging because of the high dynamic range of protein abundances. Here, we introduce a rapid and robust "plasma proteome profiling" pipeline. This single-run shotgun proteomic workflow does not require protein depletion and enables quantitative analysis of hundreds of plasma proteomes from 1 µl single finger pricks with 20 min gradients. The apolipoprotein family, inflammatory markers such as C-reactive protein, gender-related proteins, and >40 FDA-approved biomarkers are reproducibly quantified (CV <20% with label-free quantification). Furthermore, we functionally interpret a 1,000-protein, quantitative plasma proteome obtained by simple peptide pre-fractionation. Plasma proteome profiling delivers an informative portrait of a person's health state, and we envision its large-scale use in biomedicine.


Asunto(s)
Proteoma , Biomarcadores , Proteínas Sanguíneas , Cromatografía Liquida , Perfilación de la Expresión Génica , Humanos , Espectrometría de Masas , Proteómica , Espectrometría de Masas en Tándem
8.
Nat Commun ; 7: 12429, 2016 08 19.
Artículo en Inglés | MEDLINE | ID: mdl-27539542

RESUMEN

Circular RNAs (circRNAs) are broadly expressed in eukaryotic cells, but their molecular mechanism in human disease remains obscure. Here we show that circular antisense non-coding RNA in the INK4 locus (circANRIL), which is transcribed at a locus of atherosclerotic cardiovascular disease on chromosome 9p21, confers atheroprotection by controlling ribosomal RNA (rRNA) maturation and modulating pathways of atherogenesis. CircANRIL binds to pescadillo homologue 1 (PES1), an essential 60S-preribosomal assembly factor, thereby impairing exonuclease-mediated pre-rRNA processing and ribosome biogenesis in vascular smooth muscle cells and macrophages. As a consequence, circANRIL induces nucleolar stress and p53 activation, resulting in the induction of apoptosis and inhibition of proliferation, which are key cell functions in atherosclerosis. Collectively, these findings identify circANRIL as a prototype of a circRNA regulating ribosome biogenesis and conferring atheroprotection, thereby showing that circularization of long non-coding RNAs may alter RNA function and protect from human disease.


Asunto(s)
Aterosclerosis/genética , Aterosclerosis/metabolismo , ARN Largo no Codificante/metabolismo , ARN Ribosómico/metabolismo , Apoptosis , Aterosclerosis/patología , Nucléolo Celular/metabolismo , Proliferación Celular , Cromosomas Humanos Par 9 , Repeticiones Palindrómicas Cortas Agrupadas y Regularmente Espaciadas , Inhibidor p15 de las Quinasas Dependientes de la Ciclina/genética , Inhibidor p15 de las Quinasas Dependientes de la Ciclina/metabolismo , Inhibidor p16 de la Quinasa Dependiente de Ciclina , Inhibidor p18 de las Quinasas Dependientes de la Ciclina/genética , Inhibidor p18 de las Quinasas Dependientes de la Ciclina/metabolismo , Perfilación de la Expresión Génica , Células HEK293 , Humanos , Macrófagos/patología , Músculo Liso Vascular/metabolismo , Proteínas/metabolismo , Procesamiento Postranscripcional del ARN , ARN Largo no Codificante/genética , ARN Ribosómico/genética , Proteínas de Unión al ARN
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA