1.
Med Phys ; 36(6): 2089-97, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19610298

RESUMEN

A method for verifying the point spread function (PSF) measured by computed tomography has been previously reported [Med. Phys. 33, 2757-2764 (2006)]; however, this additional PSF verification following measurement is laborious. In the present study, the previously described verification method was expanded to PSF determination. First, an image was obtained by scanning a phantom. The image was then two-dimensionally deconvolved with the object function corresponding to the phantom structure, thus allowing the PSF to be obtained. Deconvolution is implemented simply by division of spatial frequencies (corresponding to inverse filtering), in which two parameters are used as adjustable ones. Second, an image was simulated by convolving the object function with the obtained PSF, and the simulated image was compared to the above-measured image of the phantom. The difference indicates the inaccuracy of the PSF obtained by deconvolution. As a criterion for evaluating the difference, the authors define the mean normalized standard deviation (SD) in the difference between simulated and measured images. The above two parameters for deconvolution can be adjusted by referring to the subsequent mean normalized SD (i.e., the PSF is determined so that the mean normalized SD is decreased). In this article, the parameters were varied in a fixed range with a constant increment to find the optimal parameter setting that minimizes the mean normalized SD. Using this method, PSF measurements were performed for various types of image reconstruction kernels (21 types) in four kinds of scanners. For the 16 types of kernels, the mean normalized SDs were less than 2.5%, indicating the accuracy of the determined PSFs. For the other five kernels, the mean normalized SDs ranged from 3.7% to 4.8%. This was because of a large amount of noise in the measured images, and the obtained PSFs would essentially be accurate. The method effectively determines the PSF, with an accompanying verification, after one scanning of a phantom.


Asunto(s)
Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Intensificación de Imagen Radiográfica/métodos , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación , Rayos X
2.
Med Biol Eng Comput ; 46(3): 273-82, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17994259

RESUMEN

Size and density measurements of objects undertaken using computed tomography (CT) are clinically significant for diagnosis. To evaluate the accuracy of these quantifications, we simulated three-dimensional (3D) CT image blurring; this involved the calculation of the convolution of the 3D object function with the measured 3D point spread function (PSF). We initially validated the simulation technique by performing a phantom experiment. Blurred computed images showed good 3D agreement with measured images of the phantom. We used this technique to compute the 3D blurred images from the object functions, in which functions are determined to have the shape of an ideal sphere of varying diameter and assume solitary pulmonary nodules with a uniform density. The accuracy of diameter and density measurements was determined. We conclude that the proposed simulation technique enables us to estimate the image blurring precisely of any 3D structure and to analyze clinical images quantitatively.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Humanos , Imagenología Tridimensional/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados
3.
Igaku Butsuri ; 26(2): 57-64, 2006.
Artículo en Japonés | MEDLINE | ID: mdl-17164534

RESUMEN

We propose a method to estimate the accuracy of the line spread function (LSF) in computed tomography (CT). When we assume an object for scanning has a shape and CT-value in the x-y scan-plane that are constant in the z-direction perpendicular to the scan-plane, blurring in the image of the object is predicted with calculation by the LSF measured in the scanner. When using the precise LSF, the calculated image must agree well with the scanned image of the phantom corresponding to the object. Then, verification of LSF is performed by comparing the calculated image with the scanned image. We measured the LSF in our scanner, and scanned a cylindrical phantom with constant diameter and CT-value in which the direction of cylinder was parallel to the z-direction, as mentioned above. Images calculated by using the LSF corresponded well to scanned images, indicating the validity of the LSF. We obtained another LSF by an inappropriate manner, and calculated images using it. Those images showed an apparent difference with scanned images, indicating the inaccuracy of the LSF. Our technique is effective to evaluate the accuracy of LSF, PSF, and also modulation transfer function (MTF) derived from the LSF or PSF.


Asunto(s)
Fantasmas de Imagen , Tomografía Computarizada por Rayos X