Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Langmuir ; 32(7): 1771-81, 2016 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-26783873

RESUMEN

Aluminum has attracted great attention recently as it has been suggested by several studies to be associated with increased risks for Alzheimer's and Parkinson's disease. The toxicity of the trivalent ion is assumed to derive from structural changes induced in lipid bilayers upon binding, though the mechanism of this process is still not well understood. In the present study we elucidate the effect of Al(3+) on supported lipid bilayers (SLBs) using fluorescence microscopy, the quartz crystal microbalance with dissipation (QCM-D) technique, dual-polarization interferometry (DPI), and molecular dynamics (MD) simulations. Results from these techniques show that binding of Al(3+) to SLBs containing negatively charged and neutral phospholipids induces irreversible changes such as domain formation. The measured variations in SLB thickness, birefringence, and density indicate a phase transition from a disordered to a densely packed ordered phase.


Asunto(s)
Aluminio/farmacología , Glicerofosfatos/química , Membrana Dobles de Lípidos/química , Fosforilcolina/química , Difusión , Conformación Molecular , Simulación de Dinámica Molecular
2.
Eur Biophys J ; 43(6-7): 241-53, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24743917

RESUMEN

Membrane-active peptides include peptides that can cross cellular membranes and deliver macromolecular cargo as well as peptides that inhibit bacterial growth. Some of these peptides can act as both transporters and antibacterial agents. It is desirable to combine the knowledge from these two different fields of membrane-active peptides into design of new peptides with tailored actions, as transporters of cargo or as antibacterial substances, targeting specific membranes. We have previously shown that the position of the amino acid tryptophan in the peptide sequence of three arginine-tryptophan peptides affects their uptake and intracellular localization in live mammalian cells, as well as their ability to inhibit bacterial growth. Here, we use quartz crystal microbalance with dissipation monitoring to assess the induced changes caused by binding of the three peptides to supported model membranes composed of POPC, POPC/POPG, POPC/POPG/cholesterol or POPC/lactosyl PE. Our results indicate that the tryptophan position in the peptide sequence affects the way these peptides interact with the different model membranes and that the presence of cholesterol in particular seems to affect the membrane interaction of the peptide with an even distribution of tryptophans in the peptide sequence. These results give mechanistic insight into the function of these peptides and may aid in the design of membrane-active peptides with specified cellular targets and actions.


Asunto(s)
Arginina , Membrana Celular/metabolismo , Péptidos/química , Péptidos/metabolismo , Tecnicas de Microbalanza del Cristal de Cuarzo , Triptófano , Secuencia de Aminoácidos , Membrana Celular/química , Liposomas/metabolismo , Datos de Secuencia Molecular , Fosfatidilcolinas/metabolismo , Fosfatidilgliceroles/metabolismo , Estructura Secundaria de Proteína
3.
Biochem Biophys Res Commun ; 435(4): 520-5, 2013 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-23643814

RESUMEN

Spontaneously beating human pluripotent stem cell-derived cardiomyocytes clusters (CMCs) represent an excellent in vitro tool for studies of human cardiomyocyte function and for pharmacological cardiac safety assessment. Such testing typically requires highly trained operators, precision plating, or large cell quantities, and there is a demand for real-time, label-free monitoring of small cell quantities, especially rare cells and tissue-like structures. Array formats based on sensing of electrical or optical properties of cells are being developed and in use by the pharmaceutical industry. A potential alternative to these techniques is represented by the quartz crystal microbalance with dissipation monitoring (QCM-D) technique, which is an acoustic surface sensitive technique that measures changes in mass and viscoelastic properties close to the sensor surface (from nm to µm). There is an increasing number of studies where QCM-D has successfully been applied to monitor properties of cells and cellular processes. In the present study, we show that spontaneous beating of CMCs on QCM-D sensors can be clearly detected, both in the frequency and the dissipation signals. Beating rates in the range of 66-168 bpm for CMCs were detected and confirmed by simultaneous light microscopy. The QCM-D beating profile was found to provide individual fingerprints of the hPS-CMCs. The presented results point towards acoustical assays for evaluation cardiotoxicity.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Auscultación Cardíaca/instrumentación , Sistemas Microelectromecánicos/instrumentación , Contracción Miocárdica/fisiología , Miocitos Cardíacos/fisiología , Espectrografía del Sonido/instrumentación , Células Cultivadas , Diseño de Equipo , Análisis de Falla de Equipo , Humanos
4.
Anal Chem ; 83(20): 7800-6, 2011 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-21877702

RESUMEN

A single-chip electrochemical method based on impedance measurements in resonance mode has been employed to study lipid monolayer and bilayer formation on hydrophobic alkanethiolate and SiO(2) substrates, respectively. The processes were monitored by temporally resolving changes in interfacial capacitance and resistance, revealing information about the rate of formation, coverage, and defect density (quality) of the layers at saturation. The resonance-based impedance measurements were shown to reveal significant differences in the layer formation process of bilayers made from (i) positively charged lipid 1-palmitoyl-2-oleoyl-sn-glycero-3-ethylphosphocholine (POEPC), (ii) neutral lipid 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) on SiO(2), and (iii) monolayers made from POEPC on hydrophobic alkanethiolate substrates. The observed responses were represented with an equivalent circuit, suggesting that the differences primarily originate from the presence of a conductive aqueous layer between the lipid bilayers and the SiO(2). In addition, by adding the ion channel gramicidin D to bilayers supported on SiO(2), channel-mediated charge transport could be measured with high sensitivity (resolution around 1 pA).


Asunto(s)
Espectroscopía Dieléctrica , Canales Iónicos/metabolismo , Membrana Dobles de Lípidos/química , Dióxido de Silicio/química , Gramicidina/química , Transporte Iónico , Fosfatidilcolinas/química
5.
Chem Res Toxicol ; 24(9): 1494-506, 2011 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-21815656

RESUMEN

Cellular motility is the major driving force of numerous biological phenomena including wound healing, immune response, embryogenesis, cancer formation, and metastasis. We studied the response of epithelial FaDu monolayers cultured on gold electrodes of an acoustic resonator (quartz crystal microbalance, QCM) and impedance sensor (electric cell-substrate impedance sensing, ECIS) to externally applied chemical stimuli interfering with cytoskeleton organization. Epithelial cell motility of confluent monolayers is characterized by subtle cell shape changes and variations in the cell-substrate as well as cell-cell distance without net directionality of individual cells. The impact of small molecules such as cytochalasin D, phalloidin, and blebbistatin as well as paclitaxel, nocodazol, and colchicin on actin and microtubules organization was quantified by conventional sensors' readouts and by comparing the noise pattern of the signals which is attributed to cellular dynamics. The responsiveness of noninvasive and label-free techniques relying on cellular dynamics is compared to classical viability assays and changes of the overall impedance of ultrasmall electrodes or acoustic loads of a thickness shear mode resonator. Depending on the agent used, a distinct sensor response was found, which can be used as a fingerprint of the cellular response. Cytoskeletal rearrangements and nuclear integrity were corroborated by fluorescence microscopy and correlated to the readouts of QCM and ECIS.


Asunto(s)
Técnicas Biosensibles/métodos , Citoesqueleto/efectos de los fármacos , Células Epiteliales/efectos de los fármacos , Moduladores de Tubulina/toxicidad , Actinas/metabolismo , Línea Celular Tumoral , Movimiento Celular/efectos de los fármacos , Citocalasina D/toxicidad , Impedancia Eléctrica , Células Epiteliales/citología , Compuestos Heterocíclicos de 4 o más Anillos/toxicidad , Humanos , Paclitaxel/toxicidad , Faloidina/toxicidad , Tecnicas de Microbalanza del Cristal de Cuarzo/métodos
6.
J Am Chem Soc ; 131(7): 2450-1, 2009 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-19178275

RESUMEN

The study of lipid transfer between lipid membranes is of great interest for the fundamental understanding of this complex and important process and, furthermore, for providing a new avenue for the in situ modification of supported lipid bilayers (SLBs). SLBs are conveniently formed by vesicle spreading onto a solid support, but this method is limited to conditions (i.e., combination of vesicle lipid composition, surface chemical properties, and buffer) such that the vesicles break spontaneously upon adsorption to the surface. Many SLB compositions are not accessible by this approach. In the present study, we give an example of how lipid transfer can be made use of to form lipid layers with striking new features, notably with respect to stability. After lipid transfer between negatively charged POPS small unilamellar vesicles and a positively charged POEPC SLB on TiO2, an SLB is obtained, which, upon exposure to SDS, leaves behind a lipid monolayer. It is shown how this monolayer can be used for creating new SLBs. The several step procedure, bilayer formation, lipid transfer, removal of a lipid monolayer and the reassembly of a bilayer, is monitored in real time by the quartz crystal microbalance with a dissipation (QCM-D) technique, and the lipid composition is analyzed for each step in postpreparation spectroscopic analyses using time-of-flight secondary ion mass spectrometry (TOF-SIMS). Comparison of the measured signal ratios with those of the reference samples containing known fractions of D31-POPS directly shows that the relative concentration of D31-POPS is approximately 50% in the SLB after D31-POPS exchange, significantly higher in the monolayer prepared in situ by SDS rinse, and approximately 20-25% after reassembly of the SLB using POEPC vesicles. The results thus provide unambiguous evidence for extensive lipid transfer between the initial POEPC SLB and D31-POPS vesicles in solution. We suggest that the reassembled SLB has a significant asymmetry between the two leaflets, and we propose that the described method is promising for the in situ preparation of asymmetric SLBs.

7.
ACS Chem Biol ; 12(5): 1288-1296, 2017 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-28294600

RESUMEN

Virus entry depends on biomolecular recognition at the surface of cell membranes. In the case of glycolipid receptors, these events are expected to be influenced by how the glycan epitope close to the membrane is presented to the virus. This presentation of membrane-associated glycans is more restricted than that of glycans in solution, particularly because of orientational constraints imposed on the glycolipid through its lateral interactions with other membrane lipids and proteins. We have developed and employed a total internal reflection fluorescence microscopy-based binding assay and a scheme for molecular dynamics (MD) membrane simulations to investigate the consequences of various glycan presentation effects. The system studied was histo-blood group antigen (HBGA) epitopes of membrane-bound glycosphingolipids (GSLs) derived from small intestinal epithelium of humans (type 1 chain) and dogs (type 2 chain) interacting with GII.4 norovirus-like particles. Our experimental results showed strong binding to all lipid-linked type 1 chain HBGAs but no or only weak binding to the corresponding type 2 chain HBGAs. This is in contrast to results derived from STD experiments with free HBGAs in solution where binding was observed for Lewis x. The MD data suggest that the strong binding to type 1 chain glycolipids was due to the well-exposed (1,2)-linked α-l-Fucp and (1,4)-linked α-l-Fucp residues, while the weaker binding or lack of binding to type 2 chain HBGAs was due to the very restricted accessibility of the (1,3)-linked α-l-Fucp residue when the glycolipid is embedded in a phospholipid membrane. Our results not only contribute to a general understanding of protein-carbohydrate interactions on model membrane surfaces, particularly in the context of virus binding, but also suggest a possible role of human intestinal GSLs as potential receptors for norovirus uptake.


Asunto(s)
Presentación de Antígeno/fisiología , Antígenos de Grupos Sanguíneos/inmunología , Glicoesfingolípidos/metabolismo , Norovirus/fisiología , Acoplamiento Viral , Animales , Perros , Humanos , Mucosa Intestinal , Simulación de Dinámica Molecular , Internalización del Virus
8.
PLoS One ; 10(5): e0125540, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25961711

RESUMEN

There is an urgent need for improved models for cardiotoxicity testing. Here we propose acoustic sensing applied to beating human cardiomyocyte clusters for non-invasive, surrogate measuring of the QT interval and other characteristics of the contractile machinery. In experiments with the acoustic method quartz crystal microbalance with dissipation monitoring (QCM-D), the shape of the recorded signals was very similar to the extracellular field potential detected in electrochemical experiments, and the expected changes of the QT interval in response to addition of conventional drugs (E-4031 or nifedipine) were observed. Additionally, changes in the dissipation signal upon addition of cytochalasin D were in good agreement with the known, corresponding shortening of the contraction-relaxation time. These findings suggest that QCM-D has great potential as a tool for cardiotoxicological screening, where effects of compounds on the cardiomyocyte contractile machinery can be detected independently of whether the extracellular field potential is altered or not.


Asunto(s)
Miocitos Cardíacos/metabolismo , Técnicas Biosensibles/métodos , Línea Celular , Citocalasina D/farmacología , Humanos , Isoproterenol/farmacología , Miocitos Cardíacos/efectos de los fármacos , Nifedipino , Piperidinas/farmacología , Piridinas/farmacología , Tecnicas de Microbalanza del Cristal de Cuarzo
9.
ACS Nano ; 9(12): 11849-62, 2015 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-26517791

RESUMEN

Advancement in the understanding of biomolecular interactions has benefited greatly from the development of surface-sensitive bioanalytical sensors. To further increase their broad impact, significant efforts are presently being made to enable label-free and specific biomolecule detection with high sensitivity, allowing for quantitative interpretation and general applicability at low cost. In this work, we have addressed this challenge by developing a waveguide chip consisting of a flat silica core embedded in a symmetric organic cladding with a refractive index matching that of water. This is shown to reduce stray light (background) scattering and thereby allow for label-free detection of faint objects, such as individual sub-20 nm gold nanoparticles as well as sub-100 nm lipid vesicles. Measurements and theoretical analysis revealed that light-scattering signals originating from single surface-bound lipid vesicles enable characterization of their sizes without employing fluorescent lipids as labels. The concept is also demonstrated for label-free measurements of protein binding to and enzymatic (phospholipase A2) digestion of individual lipid vesicles, enabling an analysis of the influence on the measured kinetics of the dye-labeling of lipids required in previous assays. Further, diffraction-limited imaging of cells (platelets) binding to a silica surface showed that distinct subcellular features could be visualized and temporally resolved during attachment, activation, and spreading. Taken together, these results underscore the versatility and general applicability of the method, which due to its simplicity and compatibility with conventional microscopy setups may reach a widespread in life science and beyond.


Asunto(s)
Técnicas Biosensibles/métodos , Microscopía/métodos , Análisis de la Célula Individual/métodos , Plaquetas/citología , Células Cultivadas , Oro/química , Humanos , Luz , Liposomas/química , Liposomas/metabolismo , Nanopartículas del Metal/química , Dispersión de Radiación
10.
J Phys Chem B ; 118(9): 2389-95, 2014 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-24364807

RESUMEN

Lipid membrane asymmetry is of fundamental importance for biological systems and also provides an attractive means for molecular control over biomaterial surface properties (including drug carriers). In particular, temperature-dependent changes of surface properties can be achieved by taking advantage of distinct phase transitions in lipid membrane coatings where lipids exchange (flip-flop) between leaflets. In this study, temperature is used to control flip-flop of lipids in asymmetric lipid membranes on planar solid supports, where the two leaflets of the lipid membrane are in different phase states. More specifically, the lower leaflet is prepared from a supported lipid membrane composed of a high Tm lipid mixture of phosphocholine (PC), phosphatidylserine (PS), and a bioactive lipid on TiO2, followed by selective removal of the top leaflet by detergent. Next, at a lower temperature, where the remaining leaflet is in the gel state, a top leaflet of a different lipid composition and in the fluid phase is formed. Phase transition-induced changes in membrane surface properties following upon temperature-activation of the prepared asymmetric membrane are demonstrated by the detection of biotinylated lipids, which were initially located (thus "hidden") in the lower-gel phase leaflet, at the surface of the top leaflet. These processes were monitored in real-time by the quartz crystal microbalance with dissipation (QCM-D) and the dual polarization interferometry (DPI) techniques, allowing modeling of the mass and the anisotropic property of the lipid structures in different phase states.


Asunto(s)
Lípidos de la Membrana/química , Interferometría , Liposomas/química , Transición de Fase , Fosfatidilcolinas/química , Fosfatidilserinas/química , Tecnicas de Microbalanza del Cristal de Cuarzo , Temperatura , Titanio/química
11.
Colloids Surf B Biointerfaces ; 116: 446-51, 2014 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-24549046

RESUMEN

For the development of advanced hemocompatible biomaterial functions, there is an unmet demand for in vitro evaluation techniques addressing platelet-surface interactions. We show that the quartz crystal microbalance with dissipation (QCM-D) monitoring technique, here combined with light microscopy, provides a surface sensitive technique that allows for real-time monitoring of the activation and aggregation of the surface-confined platelets on TiO2. The QCM-D signal monitored during adhesion and activation of platelets on TiO2 coated surfaces was found to be different in platelet-poor and platelet-rich environment although light microscopy images taken for each of the two cases looked essentially the same. Interestingly, aggregation of activated platelets was only observed in a protein-rich environment. Our results show that a layer of plasma proteins between the TiO2 surface and the platelets strongly influences the coupling between the platelets and the underlying substrate, explaining both the observed QCM-D signals and the ability of the platelets to aggregate.


Asunto(s)
Plaquetas/química , Tecnicas de Microbalanza del Cristal de Cuarzo , Titanio/química , Humanos , Tamaño de la Partícula , Propiedades de Superficie , Factores de Tiempo
12.
Sci Rep ; 3: 1452, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23486243

RESUMEN

Carbohydrate-carbohydrate interactions (CCIs) are of central importance for several biological processes. However, the ultra-weak nature of CCIs generates difficulties in studying this interaction, thus only little is known about CCIs. Here we present a highly sensitive equilibrium-fluctuation-analysis of single liposome binding events to supported lipid bilayers (SLBs) based on total internal reflection fluorescence (TIRF) microscopy that allows us to determine apparent kinetic rate constants of CCIs. The liposomes and SLBs both contained natural Le(x) glycosphingolipids (Galß4(Fucα3)GlcNAcß3Galß4Glcß1Cer), which were employed to mimic cell-cell contacts. The kinetic parameters of the self-interaction between Le(x)-containing liposomes and SLBs were measured and found to be modulated by bivalent cations. Even more interestingly, upon addition of cholesterol, the strength of the CCIs increases, suggesting that this interaction is strongly influenced by a cholesterol-dependent presentation and/or spatial organization of glycosphingolipids in cell membranes.


Asunto(s)
Calcio/metabolismo , Colesterol/metabolismo , Glicoesfingolípidos/metabolismo , Liposomas/metabolismo , Calcio/química , Secuencia de Carbohidratos , Colesterol/química , Colorantes Fluorescentes/química , Glicoesfingolípidos/química , Cinética , Membrana Dobles de Lípidos/química , Membrana Dobles de Lípidos/metabolismo , Liposomas/química
13.
Biosens Bioelectron ; 26(5): 1833-8, 2011 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-20153163

RESUMEN

An electrodeless quartz crystal microbalance with dissipation monitoring (QCM-D) setup is used to monitor the formation of supported lipid bilayers (SLBs) on bare quartz crystal sensor surfaces. The kinetic behavior of the formation of a 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) SLB on SiO(2) surfaces is discussed and compared for three cases: (i) a standard SiO(2) film deposited onto the gold electrode of a quartz crystal, (ii) an electrodeless quartz crystal with a sputter-coated SiO(2) film, and (iii) an uncoated electrodeless quartz crystal sensor surface. We demonstrate, supported by imaging the SLB on an uncoated electrodeless surface using atomic force microscopy (AFM), that a defect-free, completely covering bilayer is formed in all three cases. Differences in the kinetics of the SLB formation on the different sensor surfaces are attributed to differences in surface roughness. The latter assumption is supported by imaging the different surfaces using AFM. We show furthermore that electrodeless quartz crystal sensors can be used not only for the formation of neutral SLBs but also for positively and negatively charged SLBs. Based on our results we propose electrodeless QCM-D to be a valuable technique for lipid bilayer and related applications providing several advantages compared to electrode-coated surfaces like optical transparency, longer lifetime, and reduced costs.


Asunto(s)
Técnicas Biosensibles/instrumentación , Membrana Dobles de Lípidos/química , Sistemas Microelectromecánicos/instrumentación , Fosfatidilcolinas/química , Electrodos , Diseño de Equipo , Análisis de Falla de Equipo
14.
Langmuir ; 25(9): 5146-58, 2009 May 05.
Artículo en Inglés | MEDLINE | ID: mdl-19326873

RESUMEN

The bidirectional transfer of phospholipids between a charged, supported lipid bilayer (SLB) on SiO(2) and oppositely charged, unilamellar vesicles was studied by means of quartz crystal microbalance with dissipation (QCM-D) and optical reflectometry techniques. SLBs and vesicles were prepared from binary mixtures of 1-palmitoyl-2-oleoyl-sn-glycero-3-phosphocholine (POPC) mixed with different fractions of either 1-palmitoyl-2-oleoyl-sn-glycero-3-[phospho-l-serine] (POPS) (negatively charged) or 1-palmitoyl-2-oleoyl-sn-glycero-3-ethylphosphocholine (POEPC) (positively charged). The interaction process consists of an attachment-transfer-detachment (ATD) sequence, where added vesicles first attach to and interact with the SLB, after which they detach, leaving behind a compositionally modified SLB and ditto vesicles. When the process is complete, there is no net addition or reduction of total lipid mass in the SLB, but lipid exchange has occurred. The time scale of the process varies from a few to many tens of minutes depending on the type of charged lipid molecule and the relative concentration of charged lipids in the two membranes. Electrostatically symmetric cases, where only the charge sign (but not the fraction of charged lipid) was reversed between the SLB and the vesicles, produce qualitatively similar but quantitatively different kinetics. The time scale of the interaction varies significantly between the two cases, which is attributed to a combination of the differences in the molecular structure of the lipid headgroup for the positively and the negatively charged lipids used, and to nonsymmetric distribution of charged lipids in the lipid membranes. The maximum amounts of attached vesicles during the ATD process were estimated to be 25-40% of a full monolayer of vesicles, with the precise amount depending on the actual charge fractions in the vesicles and the SLB. Interrupted vesicle exposure experiments, and experiments where the bulk concentration of vesicles was varied, show that vesicles in some cases may be trapped irreversibly on the SLB, when only partial transfer of lipid molecules has occurred. Additional supply of vesicles and further transfer induces detachment, when a sufficient amount of oppositely charged lipids has been transferred to the SLB, so that the latter becomes repulsive to the attached vesicles. Possible mechanistic scenarios, including monomer insertion and hemifusion models, are discussed. The observed phenomena and the actual SLB preparation process form a platform both for studies of various intermembrane molecular transfer processes and for modifying the composition of SLBs in a controlled way, for example, for biosensor and cell culture applications.


Asunto(s)
Membrana Dobles de Lípidos/química , Lípidos/química , Liposomas Unilamelares/química , Cinética , Estructura Molecular , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA