Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Diabetes Obes Metab ; 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39143655

RESUMEN

AIMS: To conduct a systematic review and meta-analysis, within the Coordinating Research and Evidence for Medical Devices (CORE-MD) project, evaluating CE-marked high-risk devices for glucose management. MATERIALS AND METHODS: We identified interventional and observational studies evaluating the efficacy and safety of eight automated insulin delivery (AID) systems, two implantable insulin pumps, and three implantable continuous glucose monitoring (CGM) devices. We meta-analysed randomized controlled trials (RCTs) comparing AID systems with other treatments. RESULTS: A total of 182 studies published between 2009 and 2024 were included, comprising 166 studies on AID systems, six on insulin pumps, and 10 on CGM devices; 26% reported industry funding; 18% were pre-market; 37% had a comparator group. Of the studies identified, 29% were RCTs, 24% were non-randomized trials, and 47% were observational studies. The median (interquartile range) sample size was 48 (28-102), age 34.8 (14-44.2) years, and study duration 17.5 (12-26) weeks. AID systems lowered glycated haemoglobin by 0.5 percentage points (absolute mean difference [MD] = -0.5; 21 RCTs; I2 = 86%) and increased time in target range for sensor glucose level by 13.4 percentage points (MD = 13.4; 14 RCTs; I2 = 90%). At least one safety outcome was assessed in 71% of studies. CONCLUSIONS: High-risk devices for glucose monitoring or insulin dosing, in particular AID systems, improve glucose control safely, but evidence on diabetes-related end-organ damage is lacking due to short study durations. Methodological heterogeneity highlights the need for developing standards for future pre- and post-market investigations of diabetes-specific high-risk medical devices.

4.
BMJ Open ; 13(4): e070672, 2023 04 11.
Artículo en Inglés | MEDLINE | ID: mdl-37041065

RESUMEN

INTRODUCTION: Medical devices, including high-risk medical devices, have greatly contributed to recent improvements in the management of diabetes. However, the clinical evidence that is submitted for regulatory approval is not transparent, and thus a comprehensive summary of the evidence for high-risk devices approved for managing diabetes in Europe is lacking. In the framework of the Coordinating Research and Evidence for Medical Devices group, we will, therefore, perform a systematic review and meta-analysis, which will evaluate the efficacy, safety and usability of high-risk medical devices for the management of diabetes. METHOD AND ANALYSIS: This study has been reported according to the guidelines of the Preferred Reporting Items for Systematic Review and Meta-Analysis Protocols. We will search Embase (Elsevier), Medline All (Ovid), Cochrane Library (Wiley), Science Citation Index Expanded and Emerging Sources Citation Index (Web of Science) to identify interventional and observational studies that evaluate the efficacy and/or safety and/or usability of high-risk medical devices for the management of diabetes. No language or publication dates' limits will be applied. Animal studies will be excluded. In accordance with the Medical Device Regulation in European Union, high-risk medical devices are those in classes IIb and III. The following medical devices for diabetes management are considered as having a high risk: implantable continuous glucose monitoring systems, implantable pumps and automated insulin delivery devices. Selection of studies, data extraction and quality of evidence assessment will be performed independently by two researchers. Sensitivity analysis will be performed to identify and explain potential heterogeneity. ETHICS AND DISSEMINATION: No ethical approval is needed for this systematic review, as it is based in already published data. Our findings will be published in a peer-reviewed journal. PROSPERO REGISTRATION NUMBER: CRD42022366871.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 2 , Humanos , Glucemia , Revisiones Sistemáticas como Asunto , Metaanálisis como Asunto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA