1.
Europace ; 26(6)2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38861398

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as 'sense-B-noise.' It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. METHODS AND RESULTS: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23-64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2-70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. CONCLUSION: This multicentre analysis' findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Sistema de Registros , Humanos , Masculino , Estudios Retrospectivos , Femenino , Persona de Mediana Edad , Incidencia , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Anciano , Europa (Continente)/epidemiología , Falla de Equipo/estadística & datos numéricos , Estados Unidos/epidemiología , Factores de Riesgo
2.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38885309

RESUMEN

AIMS: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. METHODS AND RESULTS: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24-63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55-72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. CONCLUSION: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.


Asunto(s)
Desfibriladores Implantables , Suministros de Energía Eléctrica , Sistema de Registros , Humanos , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Estados Unidos/epidemiología , Muerte Súbita Cardíaca/prevención & control , Muerte Súbita Cardíaca/epidemiología , Europa (Continente)/epidemiología , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Falla de Equipo/estadística & datos numéricos , Factores de Tiempo , Análisis de Falla de Equipo/estadística & datos numéricos , Adulto
3.
J Cardiovasc Electrophysiol ; 34(10): 2019-2026, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37682001

RESUMEN

INTRODUCTION: Pulmonary vein isolation (PVI) remains the cornerstone in the treatment of atrial fibrillation (AF). PVI using cryoballoon (CB) technology has emerged as a standard procedure in many centers. Recently, pulsed field ablation (PFA) has been introduced and used to achieve PVI. First data show high acute and favorable long-term outcomes. So far, data comparing these new "single shot" devices are sparse. We sought to compare procedural and outcome data for first time PFA users versus CB in patients undergoing de novo PVI. Furthermore, potentially postprocedural discomfort and affection of autonomic ganglia were assessed. METHODS AND RESULTS: A retrospective analysis and comparison of all de novo PVIs with PFA and CB was performed. Furthermore, PFA PVI learning curve was evaluated. During follow-up, repeat outpatient visits and Holter electrocardiogram were performed to analyze arrhythmia-free survival. Discomfort analysis was obtained by prescribed analgesic medication within first 48 h after PVI. Potential changes in heart rate (HR) between baseline and at 3-month follow-up were evaluated. A total of 108 patients (54 PFA and 54 CB; PFA; 33 (30%) female) with paroxysmal and persistent AF were analyzed. Type of AF was comparable (Patients suffering from PAF: PFA: 16 (30%), CB: 17 (31%), p = 1.0). In 107 (99%) patients, successful PVI was achieved. Transient phrenic palsy omitted complete PVI in one CB patient. A trend for a shorter overall procedure duration was observed in the PFA group (PFA: 64.5 ± 17.5 min; CB: 73.0 ± 24.8 min; p = 0.07). Excluding LA mapping time (first 14 cases), procedure time was significantly shorter using PFA (PFA: 58.0 ± 12.5 min, CB: 73.0 ± 24.8 min, p = 0.0001). Fluoroscopy time was significantly longer for PFA (PFA: 15.3 ± 4.7 min, CB: 12.3 ± 5.3 min; p = 0.001), but significantly less contrast medium was used (PFA: 12 ± 6 mL; CB: 51 ± 29 mL, p < 0.0001). Subgroup analysis of the PFA group revealed a significant shortening of procedure duration over time (first tertile: 72.7 ± 13.5 min, second tertile: 67.3 ± 21.7 min, third tertile: 53.4 ± 9.8 min, first vs. third tertile p < 0.0001). Two cardiac tamponades occurred in the PFA group (p = 0.495), of which one was most likely related to complex transseptal puncture. In the first 48 h after PVI, the number of prescribed analgesics due to postprocedural pain was equal between both groups (PFA: 7 (13%) patients, CB: 10 (19%) patients, p = 0.598). After a FU of 273 ± 129 days, 35 of 47 patients (74%) after PFA and 36 of 50 patients (72%) after CB PVI were free of any atrial arrhythmia (HR: 0.98, p = 0.88). Only in the PFA group, a significant increase in HR 3 months after PVI was observed (pre-PVI: 61 ± 8 beats/min, post-PVI: 65 ± 9 beats/min, p = 0.008). CONCLUSION: The new PFA technology is equally effective and safe as compared to CB for complete PVI with potentially shorter procedure time and significantly less contrast medium. However, AF recurrence rates after PFA PVI seem to be comparable to CB PVI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Femenino , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Ablación por Catéter/métodos , Recurrencia
4.
J Cardiovasc Electrophysiol ; 34(12): 2417-2424, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37846194

RESUMEN

BACKGROUND: The newly introduced nonthermal pulsed field ablation (PFA) is a promising technology to achieve fast pulmonary vein isolation (PVI) with high acute success rates and good safety features. However, previous studies have shown that very high power short duration ablation (VHPSD) is also highly effective and fast to achieve PVI with potentially less arrhythmia recurrence compared to conventional radiofrequency ablation. Data comparing PFA to VHPSD-PVI is lacking. OBJECTIVE: This study compared procedural and outcome data for PFA-PVI to VHPSD-PVI in patients with paroxysmal or persistent atrial fibrillation (PAF/persAF). METHODS: Consecutive patients undergoing de novo PVI (PFA or VHPSD) were included in this analysis. For PFA-PVI a pentaspline 20 electrode catheter was used. For VHPSD-PVI an enhanced irrigated catheter with a power setting of 70 W/7 s (70 W/5 s at posterior wall) was employed in conjunction with electro-anatomical mapping. All procedures were performed in deep analgo-sedation. RESULTS: A total of n = 114 patients (n = 57[50%] PFA, n = 17[30%] PAF; n = 40[70%] persAF) were included in this analysis. PVI was successful in all patients. The PFA group revealed a significantly shorter procedure duration (65 ± 17 min vs. 95 ± 23 min, p < 0.01) but longer fluoroscopy time (PFA 15 ± 5 min and VHPSD 12 ± 3 min; p < 0.001). At follow-up after median 125 days (interquartile range: 109-162) n = 46 PFA (80.7%) and n = 44 VHPSD pts (77.2%) were free from atrial arrhythmia after a single procedure (p = 0.819). Two tamponades occurred in the PFA while in VHPSD two pts suffered groin bleedings. One clinically nonsignificant PV stenosis occurred in the VHPSD group. CONCLUSION: Pulsed-field ablation and VHPSD-PVI seem to be highly effective and safe to achieve PVI in the setting of PAF and persAF with comparable arrhythmia-free survival. However, procedure duration for PFA PVI is significantly shorter and therefore may be of potential benefit. Compared to PFA VHPSD-PVI might ensure information on left atrial substrate allowing to target concomitant secondary tachycardias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Resultado del Tratamiento , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Atrios Cardíacos , Recurrencia
5.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37713241

RESUMEN

AIMS: Preprocedural transoesophageal echocardiography (TEE) screening for left atrial (LA) thrombi is the standard of care in many centres performing atrial fibrillation (AF) ablation. However, TEE imposes procedural risks for patients and is often challenging to implement in daily practice, besides causing patient discomfort. At our centre, a novel standard operating procedure (SOP) was implemented, aiming to identify patients that can be exempt from TEE screening. We aimed to assess whether this screening approach may reduce preprocedural TEEs without imposing patients of higher risks for cerebrovascular events (CVEs). METHODS AND RESULTS: Data of 1874 consecutive patients treated by catheter ablation of LA arrhythmias between 2018 and 2022 were retrospectively analysed. A cohort of 937 patients, where decision to perform TEE screening was based on a new SOP (considering rhythm at admission, CHA2DS2-VASc score, and sufficient anticoagulation), was compared to a matched cohort receiving TEE before every procedure. Number of performed TEEs and incidences of CVEs were compared. Implementation of the new SOP led to a 67% reduction in TEEs performed (old SOP: 933 vs. new SOP: 305). No significant differences between the groups were detected regarding transitory ischaemic attack (old SOP: 5 vs. new SOP: 3; P = 0.48) and stroke (no events). No solid thrombi were detected during TEE screening. CONCLUSION: The number of preprocedural screening TEEs before AF ablation procedures can be safely reduced by applying risk stratification based on rhythm at admission and CHA2DS2-VASc score, if anticoagulation was performed properly.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Cardiopatías , Trombosis , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Fibrilación Atrial/epidemiología , Ecocardiografía Transesofágica , Estudios Retrospectivos , Trombosis/etiología , Anticoagulantes , Ablación por Catéter/efectos adversos , Apéndice Atrial/cirugía
6.
Europace ; 23(10): 1548-1558, 2021 10 09.
Artículo en Inglés | MEDLINE | ID: mdl-33895833

RESUMEN

AIMS: Weight management seems to be beneficial for obese atrial fibrillation (AF) patients; however, randomized data are sparse. Thus, this study aimed to investigate the influence of weight reduction on AF ablation outcomes. METHODS AND RESULTS: SORT-AF is an investigator-sponsored, prospective, randomized, multicentre, and clinical trial. Patients with symptomatic AF (paroxysmal or persistent) and body mass index (BMI) 30-40 kg/m2 underwent AF ablation and were randomized to either weight-reduction (group 1) or usual care (group 2), after sleep-apnoea-screening and loop recorder (ILR) implantation. The primary endpoint was defined as AF burden between 3 and 12 months after AF ablation. Overall, 133 patients (60 ± 10 years, 57% persistent AF) were randomized to group 1 (n = 67) and group 2 (n = 66), respectively. Complications after AF-ablation were rare (one stroke and no tamponade). The intervention led to a significant reduction of BMI (34.9 ± 2.6-33.4 ± 3.6) in group 1 compared to a stable BMI in group 2 (P < 0.001). Atrial fibrillation burden after ablation decreased significantly (P < 0.001), with no significant difference regarding the primary endpoint between the groups (P = 0.815, odds ratio: 1.143, confidence interval: 0.369-3.613). Further analyses showed a significant correlation between BMI and AF recurrence for patients with persistent AF compared with paroxysmal AF patients (P = 0.032). CONCLUSION: The SORT-AF study shows that AF ablation is safe and successful in obese patients using continuous monitoring via ILR. Although the primary endpoint of AF burden after ablation did not differ between the two groups, the effects of weight loss and improvement of exercise activity were beneficial for obese patients with persistent AF demonstrating the relevance of life-style management as an important adjunct to AF ablation in this setting. TRIAL REGISTRATION NUMBER: NCT02064114.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Humanos , Persona de Mediana Edad , Obesidad/complicaciones , Obesidad/diagnóstico , Estudios Prospectivos , Recurrencia , Resultado del Tratamiento
7.
Circulation ; 140(13): 1061-1069, 2019 09 24.
Artículo en Inglés | MEDLINE | ID: mdl-31466479

RESUMEN

BACKGROUND: Atrial arrhythmias are common in patients with implantable cardioverter-defibrillator (ICD). External shocks and internal cardioversion through commanded ICD shock for electrical cardioversion are used for rhythm-control. However, there is a paucity of data on efficacy of external versus internal cardioversion and on the risk of lead and device malfunction. We hypothesized that external cardioversion is noninferior to internal cardioversion for safety, and superior for successful restoration of sinus rhythm. METHODS: Consecutive patients with ICD undergoing elective cardioversion for atrial arrhythmias at 13 centers were randomized in 1:1 fashion to either internal or external cardioversion. The primary safety end point was a composite of surrogate events of lead or device malfunction. Conversion of atrial arrhythmia to sinus rhythm was the primary efficacy end point. Myocardial damage was studied by measuring troponin release in both groups. RESULTS: N=230 patients were randomized. Shock efficacy was 93% in the external cardioversion group and 65% in the internal cardioversion group (P<0.001). Clinically relevant adverse events caused by external or internal cardioversion were not observed. Three cases of pre-existing silent lead malfunction were unmasked by internal shock, resulting in lead failure. Troponin release did not differ between groups. CONCLUSIONS: This is the first randomized trial on external vs internal cardioversion in patients with ICDs. External cardioversion was superior for the restoration of sinus rhythm. The unmasking of silent lead malfunction in the internal cardioversion group suggests that an internal shock attempt may be reasonable in selected ICD patients presenting for electrical cardioversion. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT03247738.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/terapia , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Anciano , Anciano de 80 o más Años , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo
8.
J Cardiovasc Electrophysiol ; 30(5): 679-687, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30821012

RESUMEN

INTRODUCTION: Long-term efficacy and safety are uncertain in patients with cardiac implantable electronic devices (CIED) and transvenous leads (TVL) undergoing radiofrequency catheter ablation of atrial fibrillation (AF). Thus, we assessed the outcome of AF ablation in those patients during long-term follow-up using continuous atrial rhythm monitoring (CARM). METHODS AND RESULTS: A total of 190 patients (71.3 ± 10.7 years; 108 (56.8% men) were included in this study. At index procedure 81 (42.6%) patients presented with paroxysmal AF and 109 (57.4%) with persistent AF. The ablation strategy included pulmonary vein isolation in all patients and biatrial ablation of complex fractionated electrograms with additional ablation lines, if appropriate. AF recurrences were assessed by CARM- and CIED-related complications by device follow-up. After a mean follow-up of 55.4 ± 38.1 months, freedom of AF was found in 86 (61.4%) and clinical success defined as an AF burden less than or equal to 1% in 101 (72.1%) patients. Freedom of AF was reported in 74.6% and 51.9% (P = 0.006) and clinical success in 89.8% and 59.3% (P < 0.001) of patients with paroxysmal and persistent AF, respectively. In 3 of 408 (0.7%) ablation procedures, a TVL malfunction occurred within 90 days after catheter ablation. During long-term follow-up 9 (4.7%) patients showed lead dislodgement, 2 (1.1%) lead fracture, and 2 (1.1%) lead insulation defect not related to the ablation procedure. CONCLUSION: Our findings using CARM demonstrate long-term efficacy and safety of radiofrequency catheter ablation of AF in patients with CIED and TVL.


Asunto(s)
Arritmias Cardíacas/terapia , Fibrilación Atrial/cirugía , Estimulación Cardíaca Artificial , Ablación por Catéter , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Marcapaso Artificial , Venas Pulmonares/cirugía , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Cardíaca Artificial/efectos adversos , Ablación por Catéter/efectos adversos , Muerte Súbita Cardíaca/prevención & control , Cardioversión Eléctrica/efectos adversos , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
9.
J Cardiovasc Electrophysiol ; 30(9): 1436-1442, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31190440

RESUMEN

AIMS: We sought to assess (1) clinical outcomes of second-generation cryoballoon (CB) ablation for persistent atrial fibrillation (AF), and (2) the association of baseline and procedural covariates with atrial arrhythmia recurrence (AAR) after ablation. METHODS: A total of 135 patients (63 ± 11 years, 96 men [71%]) with persistent AF underwent CB ablation at three experienced electrophysiology centers. Freedom from AAR was estimated with the Kaplan-Meier method. A Cox proportional-hazards model was used to estimate the effects of baseline and procedural covariates on the likelihood of AAR. RESULTS: Freedom from AAR at 6, 12, and 18 months was estimated at 91% (95% confidence interval [CI] 86%-96%), 75% (95% CI, 67%-83%), and 53% (95% CI, 43%-65%), respectively. The presence of an implantable cardiac device (Hazard ratio [HR] 3.09; 95% CI, 1.37-7.00; P = .007), a left atrial (LA) diameter > 50 mm (HR 1.69; 95% CI, 1.02-2.79; P = .043), and absence of antiarrhythmic drug (AAD) therapy before the ablation procedure (HR 3.12; 95% CI, 1.72-5.64; P < .001) were associated with AAR. A trend toward an increased risk of AAR was revealed for women (HR 1.73; 95% CI, 0.96-3.11; P = .069). CONCLUSIONS: CB ablation for persistent AF resulted in freedom from AAR about that reported for RF ablation. The presence of an implantable cardiac device, LA size, and absence of AAD therapy at baseline were associated with the risk of AAR.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía , Venas Pulmonares/cirugía , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Criocirugía/efectos adversos , Criocirugía/instrumentación , Femenino , Alemania , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Supervivencia sin Progresión , Venas Pulmonares/fisiopatología , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo
10.
J Cardiovasc Electrophysiol ; 29(4): 537-547, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29377448

RESUMEN

AIMS: To evaluate the incidence of newly diagnosed intracardiac thrombi (ICT) in respect to the mode of OAC in patients undergoing cardioversion (CV). METHODS AND RESULTS: We prospectively assessed transesophageal echocardiography (TEE) and OAC therapy prior to CV in AF patients with ≥48-hour duration scheduled for CV. A total of 60 first-time ICT (4.7%) were diagnosed in 1,286 TEE, with highest rate in patients without OAC (9.6% vs. OAC 4.1%, P  =  0.009) and an apparently lower rate in nonvitamin K antagonist anticoagulants (NOAC) therapy compared to vitamin K antagonist (VKA) (2.5% vs. 5.3%, P  =  0.02). VKA therapy control 4 weeks prior to CV was overall average (time in therapeutic range 60%) and patients showed more frequently clinical characteristics and TEE parameters associated with risk for ICT. Even among patients with effective OAC therapy (uninterrupted NOAC and VKA therapy with international normalized ratio (INR) ≥2.0 for 3 weeks), ICT occurred in 2.7%, but with no difference between both groups (P  =  0.22). There was no difference between different types of NOAC. Independent predictors for ICT were history of embolism, hypertension, BMI, absence of OAC, renal function, reduced atrial appendage flow, and presence of spontaneous echo contrast. CONCLUSION: NOAC therapy seems favorable in the overall prevention of ICT, although this is likely to be caused by suboptimal VKA therapy control and differences in the overall health status between VKA and NOAC patients. ICT occurred even with effective OAC therapy suggesting individual TEE-guided cardioversion in patients at risk.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/terapia , Trombosis/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Ecocardiografía Doppler de Pulso , Ecocardiografía Transesofágica , Cardioversión Eléctrica , Electrocardiografía , Femenino , Estado de Salud , Humanos , Incidencia , Relación Normalizada Internacional , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Riesgo , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Factores de Tiempo , Resultado del Tratamiento
11.
Pacing Clin Electrophysiol ; 40(12): 1486-1488, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28543085

RESUMEN

We present a case of a patient with a baroreflex activation therapy (BAT) receiving a subcutaneous implantable cardioverter defibrillator (S-ICD). We anticipated two possible hazardous interactions between the two devices. Stimulation by the BAT could be adjudicated as noise and result in underdetection of ventricular arrhythmias or it might be misinterpreted as ventricular arrhythmias and lead to inappropriate shocks. Postop ensing occurred, the upper limit of pulse width of the BAT was limited because of noise detection by the S-ICD, but the upper limit of amplitude was limited by patient's discomfort. In this patient, the combination of a BAT and an S-ICD was safe.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Neuroestimuladores Implantables , Presorreceptores , Adulto , Desfibriladores Implantables/efectos adversos , Diseño de Equipo , Estudios de Factibilidad , Humanos , Masculino
13.
Europace ; 18(7): 994-9, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26462703

RESUMEN

AIMS: Pulmonary vein isolation (PVI) is an effective treatment option for paroxysmal atrial fibrillation (PAF). Reconnection of pulmonary veins (PVs) is the predominant cause for recurrence of PAF. However, treatment of patients with recurrence of PAF despite isolated PV in the absence of extra-PV foci remains challenging. METHODS AND RESULTS: Of 265 patients undergoing repeat catheter ablation (CA) for recurrence of PAF 21 (8%) patients (14 men, age 58 ± 14 years) showed no reconnection of PV. Therefore, inducibility of sustained atrial arrhythmias was tested. If sustained atrial fibrillation (AF) or sustained atrial tachycardia (AT) was induced, patients underwent CA. During follow-up (FU), Holter- and Tele-electrocardiogram were performed. In 19 (91%) of 21 patients, sustained atrial arrhythmias [16 (84%) AF; 3 (15%) patients AT] were induced. One patient showed PAF. Eighteen patients underwent CA aiming for termination of induced arrhythmia. In 14 (77%) patients, termination into sinus rhythm was achieved. Despite extensive CA, three (16%) patients were externally cardioverted. No periprocedural complications occurred. During 21.2 ± 6.8-month FU, 10 (53%) patients were free of any arrhythmia. Paroxysmal atrial fibrillation recurred in 4 (21%) and AT in 5 (26%) patients. One patient showed persistent AF. Repeat CA was scheduled and successfully performed for these patients. CONCLUSION: In patients with recurrence of PAF despite isolated PV, termination of induced atrial arrhythmias can be achieved in most patients by defragmentation and AT ablation. Moreover, this ablation strategy results in favourable mid-term outcome results.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Taquicardia/epidemiología , Adulto , Anciano , Ablación por Catéter/efectos adversos , Cardioversión Eléctrica , Electrocardiografía , Femenino , Alemania , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
14.
Europace ; 18(8): 1245-51, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27247017

RESUMEN

AIMS: Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS: Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION: Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.


Asunto(s)
Ablación por Catéter/métodos , Hipnóticos y Sedantes/administración & dosificación , Midazolam/uso terapéutico , Propofol/administración & dosificación , Taquicardia Ventricular/terapia , Anciano , Presión Sanguínea/efectos de los fármacos , Cardiólogos , Desfibriladores Implantables , Femenino , Alemania , Humanos , Hipotensión/inducido químicamente , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
15.
Heart Vessels ; 31(10): 1669-75, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26546306

RESUMEN

Catheter ablation of complex fractionated atrial electrograms (CFAE), also known as defragmentation ablation, may be considered for the treatment of persistent atrial fibrillation (AF) beyond pulmonary vein isolation (PVI). Concomitant antiarrhythmic drug (AAD) therapy is common, but the relevance of AAD administration and its optimal timing during ablation remain unclear. Therefore, we investigated the use and timing of AADs during defragmentation ablation and their possible implications for AF termination and ablation success in a large cohort of patients. Retrospectively, we included 200 consecutive patients (age: 61 ± 12 years, LA diameter: 47 ± 8 mm) with persistent AF (episode duration 47 ± 72 weeks) who underwent de novo ablation including CFAE ablation. In all patients, PVI was performed prior to CFAE ablation. The use and timing of AADs were registered. The follow-ups consisted of Holter ECGs and clinical visits. Termination of AF was achieved in 132 patients (66 %). Intraprocedural AADs were administered in 168/200 patients (84 %) 45 ± 27 min after completion of PVI. Amiodarone was used in the majority of the patients (160/168). The timing of AAD administration was predicted by the atrial fibrillation cycle length (AFCL). At follow-up, 88 patients (46 %) were free from atrial arrhythmia. Multivariate logistic regression analysis revealed that administration of AAD early after PVI, LA size, duration of AF history, sex and AFCL were predictors of AF termination. The administration of AAD and its timing were not predictive of outcome, and age was the sole independent predictor of AF recurrence. The administration of AAD during ablation was common in this large cohort of persistent AF patients. The choice to administer AAD therapy and the timing of the administration during ablation were influenced by AFCL, and these factors did not significantly influence the moderate single procedure success rate in this retrospective analysis.


Asunto(s)
Amiodarona/administración & dosificación , Antiarrítmicos/administración & dosificación , Fibrilación Atrial/terapia , Ablación por Catéter , Sistema de Conducción Cardíaco/fisiopatología , Venas Pulmonares/cirugía , Anciano , Electrocardiografía , Técnicas Electrofisiológicas Cardíacas , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Estudios Retrospectivos , Resultado del Tratamiento
16.
J Cardiovasc Electrophysiol ; 26(10): 1075-80, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26183341

RESUMEN

INTRODUCTION: Permanent pulmonary vein isolation (PVI) remains an essential goal of ablation therapy in patients with atrial fibrillation. Aim of this study was the intraindividual comparison of unexcitability to pacing along the ablation line versus dormant conduction (DC) as additional procedural endpoints. METHODS: A total of 58 patients with paroxysmal atrial fibrillation (PAF) underwent PVI by circumferential ablation of ipsilateral pulmonary veins (PVs), followed by testing for DC by adenosine administration. Irrespective of the presence of DC, pacing along the ablation line for left atrium capture was performed and additional radio frequency energy applied if necessary. PVs with initial DC were retested after achieving unexcitability. RESULTS: PVI was achieved in 224 of 224 PVs. In 33 of 224 PVs (15%) DC was revealed. At 92 of 112 ablation lines (82%) sites of excitability were found. Three (9%) of the initial 33 PVs with DC showed further DC after achieving unexcitability at repeated testing. Thirty-two of 33 assumed areas of unmasked PV-LA reconduction as revealed by DC-testing showed a corresponding site of excitability on the ablation line. After a follow-up of 11.6 ± 3.4 months 79% of patients were free of arrhythmia. CONCLUSIONS: Pacing for unexcitability can safely identify potential sites of DC and even sites that would have not been detected by testing for DC. Unexcitability, therefore, serves as a suitable and safe procedural endpoint not only for patients with contraindications to adenosine administration. Our data suggest that adenosine may be expendable when achieving unexcitability along the ablation line.


Asunto(s)
Adenosina , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Monitoreo Intraoperatorio/métodos , Venas Pulmonares/cirugía , Fibrilación Atrial/diagnóstico , Electrocardiografía/efectos de los fármacos , Electrocardiografía/métodos , Femenino , Sistema de Conducción Cardíaco/efectos de los fármacos , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/efectos de los fármacos , Recurrencia , Resultado del Tratamiento
17.
Heart Lung Circ ; 24(3): 270-80, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25456506

RESUMEN

INTRODUCTION: Catheter ablation of atrial fibrillation (AF) is an established rhythm control strategy; however, the impact of co-existing LV systolic dysfunction (LVSD) on ablation success is less well understood. This systematic review compiles the outcomes of catheter ablation of atrial fibrillation in patients with LVSD. METHODS: An electronic database (Pubmed, Scopus, Embase) search using the keywords 'atrial fibrillation AND ablation AND (ventricular dysfunction OR heart failure OR cardiomyopathy)' was performed for English scientific literature up to 01/01/2014. 2484 references were retrieved and evaluated for relevance by three reviewers. Reviews and reference lists of retrieved articles were also examined to ensure all relevant studies were included. Data was extracted from 19 studies, including a total of 914 patients. RESULTS: Single-procedure success in LVSD patients for AF ablation was 56.5% (95% CI: 48%-64%). Overall multiple-procedure (including the use of anti-arrhythmic drugs) in LVSD patients for AF ablation was 81.8% (95% CI: 75%-87%). The mean increase in LVEF following AF ablation was 13.3% (95% CI: 10.8%-15.9%). Seven studies reported improvements in exercise capacity and quality of life information using standardised criteria. The pooled rate of serious adverse events was 5.5% (95% CI: 3.7%-8.1%). CONCLUSIONS: Catheter ablation may be an effective therapy in AF patients with left ventricular systolic impairment, and can be associated with improvements in left ventricular function, quality of life, exercise capacity, and modest rates of serious adverse events.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Volumen Sistólico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ventrículos Cardíacos , Humanos , PubMed
19.
J Interv Card Electrophysiol ; 67(2): 399-408, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37227537

RESUMEN

BACKGROUND: Omnipolar mapping (OT) is a novel tool to acquire omnipolar signals for electro-anatomical mapping, displaying true voltage and real-time wavefront direction and speed independent of catheter orientation. The aim was to analyze previously performed left atrial (LA) and left ventricular (LV) maps for differences using automated OT vs. standard bipolar settings (SD) and HD wave (HDW) algorithm. METHODS: Previously obtained SD and HDW maps of the LA and LV using a 16-electrode, grid-shaped catheter were retrospectively analyzed by applying automated OT, comparing voltage, point density, pulmonary vein (PV) gaps, and LV scar area. RESULTS: In this analysis, 135 maps of 45 consecutive patients (30 treated for LA, 15 for LV arrhythmia) were included. Atrial maps revealed significantly higher point densities using OT (21471) vs. SD (6682) or HDW (12189, p < 0.001). Mean voltage was significantly higher using OT (0.75 mV) vs. SD (0.61 mV) or HDW (0.64 mV, p < 0.001). OT maps detected significantly more PV gaps per patient vs. SD (4 vs. 2), p = 0.001. In LV maps, OT revealed significantly higher point densities (25951) vs. SD (8582) and HDW (17071), p < 0.001. Mean voltage was significantly higher for OT (1.49 mV) vs. SD (1.19 mV) and HDW (1.2 mV), p < 0.001. Detected scar area was significantly smaller using OT (25.3%) vs. SD (33.9%, p < 0.001). CONCLUSION: OT mapping leads to significantly different substrate display, map density, voltage, detection of PV gaps, and scar size, compared to SD and HDW in LA and LV procedures. Successful CA might be facilitated due to true HD maps.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/cirugía , Cicatriz/cirugía , Estudios Retrospectivos , Atrios Cardíacos , Tecnología , Ablación por Catéter/métodos
20.
Clin Res Cardiol ; 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38478088

RESUMEN

BACKGROUND: The cryoballoon (CB) has become a standard tool for pulmonary vein isolation (PVI), but the technology is limited in certain ways. A novel RF-balloon (Heliostar™, Biosense Webster, CA, USA) promises the advantages of a balloon technology in combination with 3D mapping. METHODS: To assess procedural data and outcome, all patients undergoing RF-balloon PVI were included and compared with data from consecutive patients undergoing CB PVI for paroxysmal AF. RESULTS: A total of 254 patients (63 ± 13 years, 54% male) were included: 30 patients undergoing RF-balloon and 224 patients CB PVI. Baseline parameters were comparable. Procedure duration (104.3 ± 35.3 min vs. 69.9 ± 23.1 min; p ≤ 0.001) and fluoroscopy time (16.3 ± 7.1 min vs. 11.6 ± 4.9 min; p ≤ 0.001) were longer using the RF-balloon; ablation time (43.5 ± 17.9 vs. 36.4 ± 15.6; p = 0.08) did not differ, and time-to-isolation (TTI) was shorter (18.2 ± 7.0 s vs. 62.8 ± 35.1 s; p ≤ 0.001). Second-generation RF-balloon cases showed shorter ablation time and TTI at comparable procedure duration and fluoroscopy time. One pericardial effusion occurred with the RF-balloon due to complicated transseptal access. During CB PVI in 4/224 patients (1.8%), a phrenic nerve palsy was observed. After 12 months, 78% of patients after RF-balloon and 81% of patients after CB PVI (p = 0.5) were free from atrial arrhythmias. CONCLUSION: The RF-balloon was safe and effective. Compared with the CB, TTI was shorter, but procedure durations and fluoroscopy times were longer. This can be attributed to a learning curve and the initial necessity for separate 3D map preparation. Considering the results with the second-generation RF-balloon, more experience is needed to determine the potential benefits.