Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 21(1): 62-68, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31821729

RESUMEN

PURPOSE: To retrospectively compare clinically treated step-and-shoot intensity modulated radiotherapy (ssIMRT) and volumetric modulated arc therapy (VMAT) spine stereotactic body radiotherapy (SBRT) plans in dosimetric endpoints and pretreatment quality assurance (QA) measurements. METHODS: Five single fraction spine SBRT (18 Gy) cases - including one cervical, two thoracic, and two lumbar spines - clinically treated with ssIMRT were replanned with VMAT, and all plans were delivered to a phantom for comparing plan quality and delivery accuracy. Furthermore, we analyzed 98 clinically treated plans (18 Gy single fraction), including 34 ssIMRT and 29 VMAT for cervical/thoracic spine, and 19 ssIMRT and 16 VMAT for lumbar spine. The conformality index (CI) and homogeneity index (HI) were calculated, and QA measurement records were compared. For the spinal cord/cauda equina, the maximum dose to 0.03 cc (D0.03cc ) and volume receiving 10 or 12 Gy (V10Gy /V12Gy ) were recorded. Statistical significance was tested with the Mann-Whitney U test. RESULTS: Compared to ssIMRT, replanned VMAT plans had lower V10Gy /V12Gy and D0.03cc to the spinal cord/cauda equina in all five cases, and better CI in three out of five cases. The VMAT replans were slightly less homogeneous than those of ssIMRT plans. Both modalities passed IMRT QA with >95% passing rate with (3%, 3 mm) gamma criteria. With the 98 clinical cases, for cervical/thoracic ssIMRT and VMAT plans, the median V10Gy of spinal cord was 4.15% and 1.85% (P = 0.004); the median D0.03cc of spinal cord was 10.85 Gy and 10.10 Gy (P = 0.032); the median CI was 1.28 and 1.08 (P = 0.009); the median HI were 1.34 and 1.33 (P = 0.697), respectively. For lumbar spine, no significant dosimetric endpoint differences were observed. The two modalities were comparable in delivery accuracy. CONCLUSION: From our clinically treated plans, we found that VMAT plans provided better dosimetric quality and comparable delivery accuracy when compared to ssIMRT for single fraction spine SBRT.


Asunto(s)
Fantasmas de Imagen , Garantía de la Calidad de Atención de Salud/normas , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Columna Vertebral/cirugía , Humanos , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Estudios Retrospectivos , Neoplasias de la Columna Vertebral/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA