Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Audiol Neurootol ; 27(2): 104-108, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-33915536

RESUMEN

INTRODUCTION: Translocation of precurved cochlear implant (CI) electrodes reduces hearing outcomes, but it is not known whether it is possible to correct scalar translocation such that all electrodes reside fully in the scala tympani (ST). METHODS: Six cadaveric temporal bones were scanned with CT and segmented to delineate intracochlear anatomy. Mastoidectomy with facial recess was performed. Precurved CI electrodes (CI532; Cochlear Limited) were implanted until scalar translocation was confirmed with postoperative CT. Then, electrodes were removed and replaced. CT scan was repeated to assess for translocation correction. Scalar position of electrode contacts, angular insertion depth (AID) of the electrode array, and M- (average distance between each electrode contact and the modiolus) were measured. An in vivo case is reported in which intraoperative translocation detection led to removal and replacement of the electrode. RESULTS: Five of 6 cadaveric translocations (83%) were corrected with 1 attempt, resulting in full ST insertions. AID averaged 285 ± 77° for translocated electrodes compared to 344 ± 28° for nontranslocated electrodes (p = 0.109). M- averaged 0.75 ± 0.18 mm for translocated electrodes and 0.45 ± 0.11 mm for nontranslocated electrodes (p = 0.016). Reduction in M- with translocation correction averaged 38%. In the in vivo case, translocation was successfully corrected in a single attempt. CONCLUSION: Scalar translocation of precurved CI electrodes can be corrected by removal and reinsertion. This significantly improves the perimodiolar positioning of these electrodes. There was a high rate of success (83%) in this cadaveric model as well as a successful in vivo attempt.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cadáver , Cóclea/cirugía , Electrodos Implantados , Humanos , Rampa Timpánica/cirugía
2.
J Acoust Soc Am ; 152(1): 67, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35931512

RESUMEN

This study investigated the number of channels needed for maximum speech understanding and sound quality in 15 adult cochlear implant (CI) recipients with Advanced Bionics (AB) Mid-Scala electrode arrays completely within scala tympani. In experiment I, CI programs used a continuous interleaved sampling (CIS)-based strategy and 4-16 active electrodes. In experiment II, CI programs used an n-of-m strategy featuring 16 active electrodes with either 8- or 12-maxima. Speech understanding and sound quality measures were assessed. For CIS programs, participants demonstrated performance gains using up to 4-10 electrodes on speech measures and sound quality ratings. For n-of-m programs, there was no significant effect of maxima, suggesting 8-maxima is sufficient for this sample's maximum performance and sound quality. These results are largely consistent with previous studies using straight electrode arrays [e.g., Fishman, Shannon, and Slattery (1997). J. Speech Lang. Hear. Res. 40, 1201-1215; Friesen, Shannon, Baskent, and Wang (2001). J. Acoust. Soc. Am. 110, 1150-1163; Shannon, Cruz, and Galvin (2011). Audiol. Neurotol. 16, 113-123; Berg, Noble, Dawant, Dwyer, Labadie, and Gifford (2020). J. Acoust. Soc. Am. 147, 3646-3656] and in contrast with recent studies looking at cochlear precurved electrode arrays [e.g., Croghan, Duran, and Smith (2017). J. Acoust. Soc. Am. 142, EL537-EL543; Berg, Noble, Dawant, Dwuer, Labadie, and Gifford (2019b). J. Acoust. Soc. Am. 145, 1556-1564], which found continuous improvements up to 16 independent channels. These findings suggest that Mid-Scala electrode array recipients demonstrate similar channel independence to straight electrode arrays rather than other manufacturer's precurved electrode arrays.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Implantación Coclear/métodos , Humanos , Rampa Timpánica/cirugía , Habla
3.
J Acoust Soc Am ; 149(4): 2752, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33940865

RESUMEN

This study investigated the number of channels available to cochlear implant (CI) recipients for maximum speech understanding and sound quality for lateral wall electrode arrays-which result in large electrode-to-modiolus distances-featuring the greatest inter-electrode distances (2.1-2.4 mm), the longest active lengths (23.1-26.4 mm), and the fewest number of electrodes commercially available. Participants included ten post-lingually deafened adult CI recipients with MED-EL electrode arrays (FLEX28 and STANDARD) entirely within scala tympani. Electrode placement and scalar location were determined using computerized tomography. The number of channels was varied from 4 to 12 with equal spatial distribution across the array. A continuous interleaved sampling-based strategy was used. Speech recognition, sound quality ratings, and a closed-set vowel recognition task were measured acutely for each electrode condition. Participants did not demonstrate statistically significant differences beyond eight channels at the group level for almost all measures. However, several listeners showed considerable improvements from 8 to 12 channels for speech and sound quality measures. These results suggest that channel interaction caused by the greater electrode-to-modiolus distances of straight electrode arrays could be partially compensated for by a large inter-electrode distance or spacing.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Humanos , Rampa Timpánica/cirugía , Habla
4.
J Acoust Soc Am ; 147(5): 3646, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32486813

RESUMEN

This study investigated the effects of cochlear implant (CI) electrode array type and scalar location on the number of channels available to CI recipients for maximum speech understanding and sound quality. Eighteen post-lingually deafened adult CI recipients participated, including 11 recipients with straight electrode arrays entirely in scala tympani and 7 recipients with translocated precurved electrode arrays. Computerized tomography was used to determine electrode placement and scalar location. In each condition, the number of channels varied from 4 to 22 with equal spatial distribution across the array. Speech recognition (monosyllables, sentences in quiet and in noise), subjective speech sound quality, and closed-set auditory tasks (vowels, consonants, and spectral modulation detection) were measured acutely. Recipients with well-placed straight electrode arrays and translocated precurved electrode arrays performed similarly, demonstrating asymptotic speech recognition scores with 8-10 channels, consistent with the classic literature. This finding contrasts with recent work [Berg, Noble, Dawant, Dwyer, Labadie, and Gifford. (2019). J. Acoust. Soc. Am. 145, 1556-1564] that found precurved electrode arrays well-placed in scala tympani demonstrate continuous performance gains beyond 8-10 channels. Given these results, straight and translocated precurved electrode arrays are theorized to have less channel independence secondary to their placement farther away from neural targets.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Rampa Timpánica/cirugía , Habla
5.
J Acoust Soc Am ; 145(3): 1556, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-31067952

RESUMEN

This study investigated the number of channels needed for maximum speech understanding and sound quality in 30 adult cochlear implant (CI) recipients with perimodiolar electrode arrays verified via imaging to be completely within scala tympani (ST). Performance was assessed using a continuous interleaved sampling (CIS) strategy with 4, 8, 10, and 16 channels and n-of-m with 16 maxima. Listeners were administered auditory tasks of speech understanding [monosyllables, sentences (quiet and +5 dB signal-to-noise ratio, SNR), vowels, consonants], spectral modulation detection, as well as subjective estimates of sound quality. Results were as follows: (1) significant performance gains were observed for speech in quiet (monosyllables and sentences) with 16- as compared to 8-channel CIS, (2) 16 channels in a 16-of-m strategy yielded significantly higher outcomes than 16-channel CIS for sentences in noise (percent correct and subjective sound quality) and spectral modulation detection, (3) 16 channels in a 16-of-m strategy yielded significantly higher outcomes as compared to 8- and 10-channel CIS for monosyllables, sentences (quiet and noise), consonants, spectral modulation detection, and subjective sound quality, (4) 16 versus 8 maxima yielded significantly higher speech recognition for monosyllables and sentences in noise using an n-of-m strategy, and (5) the degree of benefit afforded by 16 versus 8 maxima was inversely correlated with mean electrode-to-modiolus distance. These data demonstrate greater channel independence with perimodiolar electrode arrays as compared to previous studies with straight electrodes and warrant further investigation of the minimum number of maxima and number of channels needed for maximum auditory outcomes.


Asunto(s)
Implantes Cocleares/normas , Software de Reconocimiento del Habla , Habla , Adulto , Anciano , Anciano de 80 o más Años , Electrodos/normas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fonética
6.
Audiol Neurootol ; 21(4): 244-249, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27576674

RESUMEN

Tissue trauma is a frequent complication of cochlear implantation (CI) surgery, but the relationship between intracochlear trauma, electrode insertion forces, and surgeons' ability to perceive these forces is poorly understood. In this study, we simulated CI surgery using a benchtop apparatus to repeatedly apply small forces to the subjects' hands while reducing the variability in their hand movements. We used a psychophysical testing procedure to estimate the force perception thresholds of 10 otologic surgeons and found a median threshold of 20.4 mN. The results suggest that surgeons have the capability to sense at least some insertion forces and are likely to perceive severe trauma such as occurs when the electrode crosses from one scala to the other.


Asunto(s)
Implantación Coclear/métodos , Otorrinolaringólogos , Umbral Sensorial/fisiología , Percepción del Tacto/fisiología , Adulto , Anciano , Implantes Cocleares , Humanos , Masculino , Persona de Mediana Edad , Modelos Anatómicos
7.
Audiol Neurootol ; 19(6): 400-11, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25402603

RESUMEN

The cochlear implant (CI) has been labeled the most successful neural prosthesis. Despite this success, a significant number of CI recipients experience poor speech understanding, and, even among the best performers, restoration to normal auditory fidelity is rare. While significant research efforts have been devoted to improving stimulation strategies, few developments have led to significant hearing improvement over the past two decades. We have recently introduced image processing techniques that open a new direction for advancement in this field by making it possible, for the first time, to determine the position of implanted CI electrodes relative to the nerves they stimulate using computed tomography images. In this article, we present results of an image-guided, patient-customized approach to stimulation that utilizes the electrode position information our image processing techniques provide. This approach allows us to identify electrodes that cause overlapping stimulation patterns and to deactivate them from a patient's map. This individualized mapping strategy yields significant improvement in speech understanding in both quiet and noise as well as improved spectral resolution in the 68 adult CI recipients studied to date. Our results indicate that image guidance can improve hearing outcomes for many existing CI recipients without requiring additional surgery or the use of 'experimental' stimulation strategies, hardware or software.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Procesamiento de Imagen Asistido por Computador , Adulto , Anciano , Anciano de 80 o más Años , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Adulto Joven
8.
Ann Otol Rhinol Laryngol ; 123(4): 235-9, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24671478

RESUMEN

OBJECTIVE: This study aimed to better identify factors associated with recurrence of squamous cell carcinoma (SCC) involving the temporal bone. METHODS: A retrospective study was conducted at a tertiary hospital. Sixty patients who were diagnosed over a 10-year period with SCC involving the temporal bone and underwent surgical resection were analyzed. All patients were staged based on the University of Pittsburgh staging system. Demographic, intraoperative, and pathologic data were analyzed with respect to recurrence. RESULTS: Thirteen (21.7%) patients were T1, 8 (13.3%) T2, 7 (11.7%) T3, and 32 (53.3%) T4. Eighteen patients (30.0%) recurred in the study period. The mean time to recurrence was 5.8 months. Tumors originating in the skin overlying the parotid gland and the external auditory canal had higher recurrence rates than those from the auricle/postauricular skin and temporal bone (P = .05). Direct parotid and perineural spread accounted for 15.0% of all routes of temporal invasion but resulted in 22.2% of all recurrences (P = .04). Increased N stage was statistically associated with increased risk of recurrence (P = .01). Cervical, as compared to perifacial and parotid, lymph node involvement was associated with increased risk of recurrence (odds ratio = 6.91; 95% confidence interval, 1.11-42.87). CONCLUSION: We have identified multiple factors that are associated with increased recurrence of SCC involving the temporal bone.


Asunto(s)
Carcinoma de Células Escamosas/patología , Recurrencia Local de Neoplasia/epidemiología , Neoplasias Craneales/patología , Hueso Temporal , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/epidemiología , Carcinoma de Células Escamosas/terapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Recurrencia Local de Neoplasia/patología , Recurrencia Local de Neoplasia/terapia , Estadificación de Neoplasias , Estudios Retrospectivos , Factores de Riesgo , Neoplasias Craneales/epidemiología , Neoplasias Craneales/terapia
9.
J ECT ; 30(4): 303-8, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24755726

RESUMEN

OBJECTIVE: Cochlear implants (CI) are neural prostheses that restore hearing to individuals with profound sensorineural hearing loss. The surgically implanted component consists of an electrode array, which is threaded into the cochlea, and an electronic processor, which is buried under the skin behind the ear. The Food and Drug Administration and CI manufacturers contend that electroconvulsive therapy (ECT) is contraindicated in CI recipients owing to risk of damage to the implant and/or the patient. We hypothesized that ECT does no electrical damage to CIs. METHODS: Ten functional CIs were implanted in 5 fresh cadaveric human heads. Each head then received a consecutive series of 12 unilateral ECT sessions applying maximum full pulse-width energy settings. Electroconvulsive therapy was delivered contralaterally to 5 CIs and ipsilaterally to 5 CIs. Electrical integrity testing (impedance testing) of the electrode array was performed before and after CI insertion, and after the first, third, fifth, seventh, ninth, and 12th ECT sessions. Electroconvulsive therapy was performed by a staff psychiatrist experienced with the technique. Explanted CIs were sent back to the manufacturer for further integrity testing. RESULTS: No electrical damage was identified during impedance testing. Overall, there were statistically significant decreases in impedances (consistent with no electrical damage) when comparing pre-ECT impedance values to those after 12 sessions. There was no statistically significant difference (P > 0.05) in impedance values comparing ipsilateral to contralateral ECT. Manufacturer testing revealed no other electrical damage to the CIs. CONCLUSION: Electroconvulsive therapy does not seem to cause any detectable electrical injury to CIs.


Asunto(s)
Implantes Cocleares/normas , Impedancia Eléctrica , Terapia Electroconvulsiva , Cadáver , Electrodos Implantados , Lateralidad Funcional , Humanos
10.
Otol Neurotol Open ; 4(1): e049, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38533347

RESUMEN

Objective: To assess image artifact when imaging a cochlear implant (CI) with a conventional 3T MRI machine compared with a very low-field (0.064T) MRI. Patients: None. Intervention: Diagnostic study. Main Outcome Measure: Image artifact size associated with the CI affixed to an MRI phantom at very low-field 0.064T MRI versus 3T MRI. Results: The longest diameter of the image artifact was 125 mm for the 3T MRI and 86 mm for the 0.064T MRI, representing 45% longer image artifact generated in the 3T MRI. The actual volume of the imaging phantom was 1371 cm3. The volume of the image artifact was measured as 379 cm3 in the 3T MRI, representing a loss of 27.6% of the actual volume of the imaging phantom. The volume of image artifact was measured as 170 cm3 in the 0.064T MRI, representing a loss of 12.4% of the phantom volume. Conclusions: 3T MRI had better image quality. This result was not surprising given that larger magnetic field strength is known to provide higher resolution. There was 15% less image artifact generated in the very low-field MRI machine compared with a conventional 3T device. And there was also subjectively increased distortion of the imaging phantom at 3T MRI compared with the 0.064T MRI. With minimized safety concerns and a much lower cost than conventional 3T machines, very low-field scanners may find expanded clinical uses. This preclinical study explores the potential utility of very low-field MRI in scanning CI recipients.

11.
Laryngoscope ; 134(9): 3883-3891, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38506449

RESUMEN

OBJECTIVES: To comprehensively examine the characteristics and prognosis of bilateral sudden sensorineural hearing loss (BSSHL) and its subtypes compared to unilateral sudden sensorineural hearing loss (USSHL). DATA SOURCES: PubMed, Scopus, and CINAHL. REVIEW METHODS: Databases were searched from inception to December 5, 2023, for studies reporting patient characteristics and audiometric outcomes for BSSHL and its simultaneous (Si-BSSHL) and sequential (Se-BSSHL) subtypes. Meta-analysis of continuous measures, proportions (%), mean differences (Δ), and odds ratio (OR) were performed. RESULTS: Eleven studies were included, consisting of 368 patients with BSSHL and 2,705 patients with USSHL. The pooled prevalence among all SSHL cases was 88.1% (95% CI: 81.2%-93.6%) for USSHL and 11.9% (95% CI: 6.4% to 18.8%) for BSSHL. PTA improvement following treatment with steroids was significantly worse in patients with BSSHL (Δ15.3 dB; 95% CI: 14.6 to 15.9; p < 0.0001) compared to patients with USSHL. There was no significant difference in post-treatment PTA improvement between the BSSHL subtypes. Patients with Si-BSSHL were significantly less likely to have an idiopathic etiology (OR: 0.4; 95% CI: 0.2 to 0.8; p = 0.01) and significantly more likely to have an autoimmune disease etiology (OR: 27.4; 95% CI: 2.2 to 336.1; p = 0.01), comorbid cardiovascular disease (OR: 2.3; 95% CI: 1.1 to 5.1; p = 0.03), and comorbid hypertension (OR: 2.5; 95% CI: 1.6 to 3.8; p < 0.0001) compared to patients with USSHL. CONCLUSIONS: BSSHL is a considerably rarer form of SSHL with worse prognosis compared to USSHL. BSSHL, and Si-BSSHL in particular, has significantly greater associations with systemic pathologies compared to USSHL. Laryngoscope, 134:3883-3891, 2024.


Asunto(s)
Pérdida Auditiva Sensorineural , Pérdida Auditiva Súbita , Humanos , Pérdida Auditiva Sensorineural/epidemiología , Pérdida Auditiva Sensorineural/diagnóstico , Pronóstico , Pérdida Auditiva Súbita/diagnóstico , Pérdida Auditiva Súbita/epidemiología , Pérdida Auditiva Bilateral/epidemiología , Pérdida Auditiva Bilateral/diagnóstico , Masculino , Femenino , Prevalencia
12.
Int J Med Robot ; 20(1): e2609, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38536718

RESUMEN

BACKGROUND: Cochlear-implant electrode arrays (EAs) are currently inserted with limited feedback, and impedance sensing has recently shown promise for EA localisation. METHODS: We investigate the use of impedance sensing to infer the progression of an EA during insertion. RESULTS: We show that the access resistance component of bipolar impedance sensing can detect when a straight EA reaches key anatomical locations in a plastic cochlea and when each electrode contact enters/exits the cochlea. We also demonstrate that dual-sided electrode contacts can provide useful proximity information and show the real-time relationship between impedance and wall proximity in a cadaveric cochlea for the first time. CONCLUSION: The access resistance component of bipolar impedance sensing has high potential for estimating positioning information of EAs relative to anatomy during insertion. Main limitations of this work include using saline as a surrogate for human perilymph in ex vivo models and using only one type of EA.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Impedancia Eléctrica , Cóclea/cirugía , Electrodos Implantados
13.
Otolaryngol Head Neck Surg ; 170(5): 1234-1245, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38353342

RESUMEN

OBJECTIVE: To evaluate the treatment efficacy of neuromodulation versus sham for the treatment of tinnitus. DATA SOURCES: Cochrane Library, CINAHL, PubMed, Scopus. REVIEW METHODS: The Cochrane Library, CINAHL, PubMed, and Scopus were searched from inception through May 2023 for English language articles documenting "neuromodulation" and "tinnitus" stratified by sham-controlled randomized control trials with 40 or more patients. Data collected included Beck Anxiety Inventory, Beck Depression Inventory (BDI), Tinnitus Handicap Inventory (THI), Tinnitus Questionnaire, and Visual Analog Scale. A Meta-analysis of continuous measures (mean) and proportions (%) were conducted. RESULTS: A total of 19 randomized control trials (N = 1186) were included. The mean age was 48.4 ± 5.3 (range: 19-74), mean duration of tinnitus was 3.8 ± 3.4 years, 61% [56.2-65.7] male, and 55.7% [46-65] with unilateral tinnitus. The short-term effect of transcutaneous electrical nerve stimulation and transcranial direct current stimulation on THI score is -16.2 [-23.1 to -9.3] and -19 [-30.1 to -7.8], respectively. The long-term effect of repetitive transcranial magnetic stimulation on THI score is -8.6 [-11.5 to -5.7]. Transcranial direct current stimulation decreases BDI score by -11.8 [-13.3 to -10.3]. CONCLUSION: As measured by the Tinnitus Handicap Index, our findings suggest the effects of transcutaneous electrical nerve stimulation and transcranial direct current stimulation reach significant benefit in the short term, whereas repetitive transcranial magnetic stimulation reaches significant benefit in the long term. Based on the BDI, transcranial direct current stimulation significantly reduces comorbid depression in patients with tinnitus.


Asunto(s)
Acúfeno , Acúfeno/terapia , Humanos , Estimulación Eléctrica Transcutánea del Nervio/métodos , Resultado del Tratamiento , Estimulación Magnética Transcraneal/métodos , Estimulación Transcraneal de Corriente Directa/métodos , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
Otol Neurotol ; 45(7): 790-797, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38923968

RESUMEN

OBJECTIVES: To assess the clinical utility of spread of excitation (SOE) functions obtained via electrically evoked compound action potentials (eCAP) to 1) identify electrode array tip fold-over, 2) predict electrode placement factors confirmed via postoperative computed tomography (CT) imaging, and 3) predict postoperative speech recognition through the first year post-activation in a large clinical sample. STUDY DESIGN: Retrospective case review. SETTING: Cochlear implant (CI) program at a tertiary medical center. PATIENTS: Two hundred seventy-two ears (238 patients) with Cochlear Ltd. CIs (mean age = 46 yr, range = 9 mo-93 yr, 50% female) implanted between August 2014 and December 2022 were included. MAIN OUTCOME MEASURES: eCAP SOE widths (mm) (probe electrodes 5, 11, and 17), incidence of electrode tip fold-over, CT imaging data (electrode-to-modiolus distance, angular insertion depth, scalar location), and speech recognition outcomes (consonant-nucleus-consonant [CNC], AzBio quiet, and +5 dB SNR) through the first year after CI activation. RESULTS: 1) eCAP SOE demonstrated a sensitivity of 85.7% for identifying tip fold-over instances that were confirmed by CT imaging. In the current dataset, the tip fold-over incidence rate was 3.1% (7 patients), with all instances involving a precurved electrode array. 2) There was a significant positive relationship between eCAP SOE and mean electrode-to-modiolus distance for precurved arrays, and a significant positive relationship between eCAP SOE and angular insertion depth for straight arrays. No relationships between eCAP SOE and scalar location or cochlea diameter were found in this sample. 3) There were no significant relationships between eCAP SOE and speech recognition outcomes for any measure or time point, except for a weak negative correlation between average eCAP SOE widths and CNC word scores at 6 months post-activation for precurved arrays. CONCLUSIONS: In the absence of intraoperative CT or fluoroscopic imaging, eCAP SOE is a reasonable alternative method for identifying electrode array tip fold-over and should be routinely measured intraoperatively, especially for precurved electrode arrays with a sheath.


Asunto(s)
Potenciales de Acción , Implantación Coclear , Implantes Cocleares , Percepción del Habla , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Implantación Coclear/métodos , Adulto , Estudios Retrospectivos , Anciano de 80 o más Años , Preescolar , Adulto Joven , Adolescente , Niño , Lactante , Percepción del Habla/fisiología , Potenciales de Acción/fisiología , Potenciales Evocados Auditivos/fisiología , Tomografía Computarizada por Rayos X
15.
Ear Nose Throat J ; : 1455613241275320, 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39292950

RESUMEN

Objective: To assess whether preferential hiring practices, particularly self-hiring, are present in academic otolaryngology departments. Setting: A list of academic Otolaryngology-Head and Neck Surgery (O-HNS) departments ranked #1-40 was generated from the Doximity 2021 rankings. The educational background and training information of clinical faculty members and departmental leadership was extracted from each department's online directories. Methods: Descriptive statistics were used to examine inter/intradepartmental relationships and affiliations of included clinical faculty and departmental leadership based on current employment and medical training sites. A "prior affiliation ratio" was calculated to assess the degree of self-hiring and account for multiple possible prior affiliations (medical school, residency, and fellowship) by dividing all prior self-hired affiliations of faculty by the total number of faculty at each department. Results: A total of 1344 clinical faculty were identified, and 596 (44.35%) had at least 1 prior affiliation with their department. The overall prior affiliation ratio was 0.6, and 7 departments had a value >0.8, with the highest being 1.27 (>1.0 indicating multiple prior affiliations per individual such as both residency and fellowship). A network map of departments #1-10 showed heavy intradepartmental faculty recruitment with 24% of faculty having completed a #1-10 residency, 24% a #11-20 residency, 13% a #21-30 residency, and 11% a #31-40 residency. Totaling this data, 76% of faculty at departments ranked #1-10 had completed training at a program ranked #1-40. Furthermore, our data shows high rates of self-hiring among departmental leadership, (40% of Departmental Chairs and 62.5% of Program Directors) though rates are not significantly higher than self-hiring among faculty overall. Conclusion: The top 40 ranked O-HNS departments have high rates of self-hiring, relying on prestige of training programs and prior affiliation in hiring decisions. The effect on departmental productivity and training is unclear.

16.
Otol Neurotol ; 45(8): 887-894, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39052893

RESUMEN

OBJECTIVE: To prospectively evaluate the association between hearing preservation after cochlear implantation (CI) and intracochlear electrocochleography (ECochG) amplitude parameters. STUDY DESIGN: Multi-institutional, prospective randomized clinical trial. SETTING: Ten high-volume, tertiary care CI centers. PATIENTS: Adults (n = 87) with sensorineural hearing loss meeting CI criteria (2018-2021) with audiometric thresholds of ≤80 dB HL at 500 Hz. METHODS: Participants were randomized to CI surgery with or without audible ECochG monitoring. Electrode arrays were inserted to the full-depth marker. Hearing preservation was determined by comparing pre-CI, unaided low-frequency (125-, 250-, and 500-Hz) pure-tone average (LF-PTA) to LF-PTA at CI activation. Three ECochG amplitude parameters were analyzed: 1) insertion track patterns, 2) magnitude of ECochG amplitude change, and 3) total number of ECochG amplitude drops. RESULTS: The Type CC insertion track pattern, representing corrected drops in ECochG amplitude, was seen in 76% of cases with ECochG "on," compared with 24% of cases with ECochG "off" ( p = 0.003). The magnitude of ECochG signal drop was significantly correlated with the amount of LF-PTA change pre-CI and post-CI ( p < 0.05). The mean number of amplitude drops during electrode insertion was significantly correlated with change in LF-PTA at activation and 3 months post-CI ( p ≤ 0.01). CONCLUSIONS: ECochG amplitude parameters during CI surgery have important prognostic utility. Higher incidence of Type CC in ECochG "on" suggests that monitoring may be useful for surgeons in order to recover the ECochG signal and preventing potentially traumatic electrode-cochlear interactions.


Asunto(s)
Audiometría de Respuesta Evocada , Implantación Coclear , Pérdida Auditiva Sensorineural , Humanos , Audiometría de Respuesta Evocada/métodos , Implantación Coclear/métodos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Pérdida Auditiva Sensorineural/cirugía , Pérdida Auditiva Sensorineural/fisiopatología , Estudios Prospectivos , Implantes Cocleares , Cóclea/cirugía , Cóclea/fisiopatología , Adulto , Audición/fisiología , Audiometría de Tonos Puros
17.
Stud Health Technol Inform ; 184: 215-21, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23400159

RESUMEN

This paper provides instructions for a virtual exploration and self-study of surgical approaches within the temporal bone. Linear drilling trajectories in the sense of "keyhole" accesses are compared with true-color rendering techniques using freeware to introduce and evaluate new otologic approaches. On the basis of public-domain cyro-histology image data from a temporal bone six different drill trajectories are presented. This virtual method has the potential to be a first step in investigation of new surgical approaches before moving to cadaver testing.


Asunto(s)
Implantación Coclear/métodos , Imagenología Tridimensional/métodos , Apófisis Mastoides/anatomía & histología , Apófisis Mastoides/cirugía , Osteotomía/métodos , Cirugía Asistida por Computador/métodos , Interfaz Usuario-Computador , Color , Bases de Datos Factuales , Humanos
18.
J Med Imaging (Bellingham) ; 10(4): 044003, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37476645

RESUMEN

Purpose: Cochlear implants (CIs) have been shown to be highly effective restorative devices for patients suffering from severe-to-profound hearing loss. Hearing outcomes with CIs depend on electrode positions with respect to intracochlear anatomy. Intracochlear anatomy can only be directly visualized using high-resolution modalities, such as micro-computed tomography (µCT), which cannot be used in vivo. However, active shape models (ASM) have been shown to be robust and effective for segmenting intracochlear anatomy in large scale datasets of patient computed tomographies (CTs). We present an extended dataset of µCT specimens and aim to evaluate the ASM's performance more comprehensively than has been previously possible. Approach: Using a dataset of 16 manually segmented cochlea specimens on µCTs, we found parameters that optimize mean CT segmentation performance and then evaluate the effect of library size on the ASM. The optimized ASM was further evaluated on a clinical dataset of 134 CT images to assess method reliability. Results: Optimized parameters lead to mean CT segmentation performance to 0.36 mm point-to-point error, 0.10 mm surface error, and 0.83 Dice score. Larger library sizes provide diminishing returns on segmentation performance and total variance captured by the ASM. We found our method to be clinically reliable with the main performance limitation that was found to be the candidate search process rather than model representation. Conclusions: We have presented a comprehensive validation of the ASM for use in intracochlear anatomy segmentation. These results are critical to understand the limitations of the method for clinical use and for future development.

19.
Otol Neurotol ; 44(4): 324-330, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36728107

RESUMEN

HYPOTHESIS: This study evaluated the utility of the pull-back technique in improving perimodiolar positioning of a precurved cochlear implant (CI) electrode array (EA) with simultaneous insertion force profile measurement and direct observation of dynamic EA behavior. BACKGROUND: Precurved EAs with perimodiolar positioning have improved outcomes compared with straight EAs because of lowered charge requirements for stimulation and decreased spread of excitation. The safety and efficacy of the pull-back technique in further improving perimodiolar positioning and its associated force profile have not been adequately demonstrated. METHODS: The bone overlying the scala vestibuli was removed in 15 fresh cadaveric temporal bones, leaving the scala tympani unviolated. Robotic insertions of EAs were performed with simultaneous force measurement and video recording. Force profiles were obtained during standard insertion, overinsertion, and pull-back. Postinsertion CT scans were obtained during each of the three conditions, enabling automatic segmentation and calculation of angular insertion depth, mean perimodiolar distance ( Mavg ), and cochlear duct length. RESULTS: Overinsertion did not result in significantly higher peak forces than standard insertion (mean [SD], 0.18 [0.06] and 0.14 [0.08] N; p = 0.18). Six temporal bones (40%) demonstrated visibly improved perimodiolar positioning after the protocol, whereas none worsened. Mavg significantly improved after the pull-back technique compared with standard insertion (mean [SD], 0.34 [0.07] and 0.41 [0.10] mm; p < 0.01). CONCLUSIONS: The pull-back technique was not associated with significantly higher insertional forces compared with standard insertion. This technique was associated with significant improvement in perimodiolar positioning, both visually and quantitatively, independent of cochlear size.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Implantación Coclear/métodos , Rampa Timpánica/cirugía , Escala Vestibular , Electrodos Implantados
20.
Otolaryngol Head Neck Surg ; 169(4): 780-791, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37003296

RESUMEN

OBJECTIVE: To investigate the impact of the surgical indication on posttonsillectomy bleed rates. DATA SOURCES: PubMed, Scopus, CINAHL. REVIEW METHODS: A systematic review was performed searching for articles published from the date of inception to July 6, 2022. English language articles describing posttonsillectomy hemorrhage rates in pediatric patients (age ≤ 18) stratified by indication were selected for inclusion. A meta-analysis of proportions with comparison (Δ) of weighted proportions was conducted. All studies were assessed for risk of bias. RESULTS: A total of 72 articles with 173,970 patients were selected for inclusion. The most common indications were chronic/recurrent tonsillitis (CT/RT), obstructive sleep apnea/sleep-disordered breathing (OSA/SDB), and adenotonsillar hypertrophy (ATH). Posttonsillectomy hemorrhage rates for CT/RT, OSA/SDB, and ATH were 3.57%, 3.69%, and 2.72%, respectively. Patients operated on for a combination of CT/RT and OSA/SDB had a bleed rate of 5.99% which was significantly higher than those operated on for CT/RT alone (Δ2.42%, p = .0006), OSA/SDB alone (Δ2.30%, p = .0016), and ATH alone (Δ3.27%, p < .0001). Additionally, those operated on for a combination of ATH and CT/RT had a hemorrhage rate of 6.93%, significantly higher than those operated on for CT/RT alone (Δ3.36%, p = .0003), OSA/SDB alone (Δ3.01%, p = .0014), and ATH alone (Δ3.98%, p < .0001). CONCLUSION: Patients operated on for multiple indications had significantly higher rates of posttonsillectomy hemorrhage than those operated on for a single surgical indication. Better documentation of patients with multiple indications would help further characterize the magnitude of the compounding effect described here.


Asunto(s)
Apnea Obstructiva del Sueño , Tonsilectomía , Tonsilitis , Niño , Humanos , Tonsilectomía/efectos adversos , Apnea Obstructiva del Sueño/cirugía , Tonsila Palatina , Adenoidectomía/efectos adversos , Tonsilitis/cirugía , Hemorragia , Hipertrofia/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA