Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 379(18): 1699-1710, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-30145971

RESUMEN

BACKGROUND: Among patients with acute myocardial infarction, cardiogenic shock, and multivessel coronary artery disease, the risk of a composite of death from any cause or severe renal failure leading to renal-replacement therapy at 30 days was found to be lower with percutaneous coronary intervention (PCI) of the culprit lesion only than with immediate multivessel PCI. We evaluated clinical outcomes at 1 year. METHODS: We randomly assigned 706 patients to either culprit-lesion-only PCI or immediate multivessel PCI. The results for the primary end point of death or renal-replacement therapy at 30 days have been reported previously. Prespecified secondary end points at 1 year included death from any cause, recurrent myocardial infarction, repeat revascularization, rehospitalization for congestive heart failure, the composite of death or recurrent infarction, and the composite of death, recurrent infarction, or rehospitalization for heart failure. RESULTS: As reported previously, at 30 days, the primary end point had occurred in 45.9% of the patients in the culprit-lesion-only PCI group and in 55.4% in the multivessel PCI group (P=0.01). At 1 year, death had occurred in 172 of 344 patients (50.0%) in the culprit-lesion-only PCI group and in 194 of 341 patients (56.9%) in the multivessel PCI group (relative risk, 0.88; 95% confidence interval [CI], 0.76 to 1.01). The rate of recurrent infarction was 1.7% with culprit-lesion-only PCI and 2.1% with multivessel PCI (relative risk, 0.85; 95% CI, 0.29 to 2.50), and the rate of a composite of death or recurrent infarction was 50.9% and 58.4%, respectively (relative risk, 0.87; 95% CI, 0.76 to 1.00). Repeat revascularization occurred more frequently with culprit-lesion-only PCI than with multivessel PCI (in 32.3% of the patients vs. 9.4%; relative risk, 3.44; 95% CI, 2.39 to 4.95), as did rehospitalization for heart failure (5.2% vs. 1.2%; relative risk, 4.46; 95% CI, 1.53 to 13.04). CONCLUSIONS: Among patients with acute myocardial infarction and cardiogenic shock, the risk of death or renal-replacement therapy at 30 days was lower with culprit-lesion-only PCI than with immediate multivessel PCI, and mortality did not differ significantly between the two groups at 1 year of follow-up. (Funded by the European Union Seventh Framework Program and others; CULPRIT-SHOCK ClinicalTrials.gov number, NCT01927549 .).


Asunto(s)
Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/métodos , Choque Cardiogénico/terapia , Anciano , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/etiología , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Readmisión del Paciente , Recurrencia , Insuficiencia Renal/etiología , Insuficiencia Renal/terapia , Terapia de Reemplazo Renal , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad
2.
N Engl J Med ; 377(25): 2419-2432, 2017 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-29083953

RESUMEN

BACKGROUND: In patients who have acute myocardial infarction with cardiogenic shock, early revascularization of the culprit artery by means of percutaneous coronary intervention (PCI) improves outcomes. However, the majority of patients with cardiogenic shock have multivessel disease, and whether PCI should be performed immediately for stenoses in nonculprit arteries is controversial. METHODS: In this multicenter trial, we randomly assigned 706 patients who had multivessel disease, acute myocardial infarction, and cardiogenic shock to one of two initial revascularization strategies: either PCI of the culprit lesion only, with the option of staged revascularization of nonculprit lesions, or immediate multivessel PCI. The primary end point was a composite of death or severe renal failure leading to renal-replacement therapy within 30 days after randomization. Safety end points included bleeding and stroke. RESULTS: At 30 days, the composite primary end point of death or renal-replacement therapy had occurred in 158 of the 344 patients (45.9%) in the culprit-lesion-only PCI group and in 189 of the 341 patients (55.4%) in the multivessel PCI group (relative risk, 0.83; 95% confidence interval [CI], 0.71 to 0.96; P=0.01). The relative risk of death in the culprit-lesion-only PCI group as compared with the multivessel PCI group was 0.84 (95% CI, 0.72 to 0.98; P=0.03), and the relative risk of renal-replacement therapy was 0.71 (95% CI, 0.49 to 1.03; P=0.07). The time to hemodynamic stabilization, the risk of catecholamine therapy and the duration of such therapy, the levels of troponin T and creatine kinase, and the rates of bleeding and stroke did not differ significantly between the two groups. CONCLUSIONS: Among patients who had multivessel coronary artery disease and acute myocardial infarction with cardiogenic shock, the 30-day risk of a composite of death or severe renal failure leading to renal-replacement therapy was lower among those who initially underwent PCI of the culprit lesion only than among those who underwent immediate multivessel PCI. (Funded by the European Union 7th Framework Program and others; CULPRIT-SHOCK ClinicalTrials.gov number, NCT01927549 .).


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/terapia , Intervención Coronaria Percutánea/métodos , Choque Cardiogénico/etiología , Anciano , Enfermedad de la Arteria Coronaria/complicaciones , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/mortalidad , Insuficiencia Renal/etiología , Insuficiencia Renal/terapia , Terapia de Reemplazo Renal , Riesgo , Choque Cardiogénico/mortalidad , Tiempo de Tratamiento
3.
J Cardiovasc Electrophysiol ; 27(5): 507-14, 2016 05.
Artículo en Inglés | MEDLINE | ID: mdl-26732468

RESUMEN

INTRODUCTION: Focal impulses (FI) and rotors are sources associated with the initiation and maintenance of atrial fibrillation (AF). Their ablation results in a lower recurrence rate. The aim of this study was to characterize for the first time the spatial relationship between such sources and atrial low voltage zones (LVZ) representing fibrosis. METHODS: Twenty-five consecutive patients undergoing their first ablation for persistent AF were included. Voltage mapping of both atria was done during AF. Endocardial mapping of FI and rotors (sources) was performed using a basket catheter and displayed using RhythmView(TM) (Topera Inc.) before ablation. Spatial relationship of LVZ and sources was analyzed. RESULTS: LVZs covered 13 ± 12% of right atrial (RA) endocardial surface and 33 ± 25% of left atrial (LA) endocardial surface. The median number of sources was 1 [1-3] in RA and 3 [1-4] in LA. Of LA sources, 18 (30%) were definitely not associated with LVZs or pulmonary vein (PV) antra. Of RA sources, 32 (84%) were remote from LVZ. During ablation of such sources substantial cycle length (CL) prolongation or AF conversion occurred in 11/23 patients (48%). Altogether, 8/11 (73%) of these pertinent sources were located remotely from LVZ and PV antra. CONCLUSIONS: There is a wide discrepancy in distribution of LVZ areas and sites of identified rotors. Site and incidence of FIRM sources appear to be unpredictable with atrial substrate mapping. Further prospective, randomized studies are necessary to elucidate the impact of additional ablation of such sources in patients with persistent or longstanding persistent AF.


Asunto(s)
Potenciales de Acción , Fibrilación Atrial/fisiopatología , Atrios Cardíacos/fisiopatología , Sistema de Conducción Cardíaco/fisiopatología , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Femenino , Fibrosis , Atrios Cardíacos/patología , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/patología , Sistema de Conducción Cardíaco/cirugía , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
4.
J Am Soc Echocardiogr ; 37(4): 397-404, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38072288

RESUMEN

BACKGROUND: Transcatheter edge-to-edge repair (TEER) for the treatment of tricuspid regurgitation (TR) has experienced fast adoption following commercial approval. Defining the appropriate target population for TEER therapy is important to guide patient selection. The aim of this study was to characterize tricuspid valve anatomy and coaptation gap in subjects receiving TEER for the treatment of TR in a contemporary postmarket setting. METHODS: The bRIGHT study is a prospective, multicenter, single-arm, postmarket study evaluating the safety and effectiveness of the TriClip device. Procedural outcomes included implant success, acute procedural success, TR severity, major adverse events, single-leaflet device attachment, and embolization through 30 postprocedure days. Tricuspid valve characteristics, including morphology, annulus size, and leaflet mobility, were assessed via two-dimensional transesophageal echocardiography from the screening visit by an independent echo core lab to characterize subject variability. Coaptation gap measurements were taken in both the transgastric short-axis (TG SAX) and RV inflow/outflow views. RESULTS: The independent echo core lab performed a detailed assessment of the tricuspid valve on 135 consecutive subjects with available TG SAX views from 24 sites. Tricuspid valve morphologies included 2 to 5 leaflets, with a non-trileaflet valve in 28% of subjects and ≥4 leaflets in 21% of subjects. The etiology of TR was functional in 91% (96/105), mixed in 7% (7/105), and lead induced in 2% (2/105) of subjects. Leaflet mobility was mildly restricted in 69% (78/113) and moderately restricted in 7% (8/113) of subjects. Annulus diameter averaged 4.7 ± 0.7 cm with a range of 2.5 to 6.2 cm. From the TG SAX view, the coaptation gap measured 8.1 ± 3.1 and 5.2 ± 2.3 mm in the central and mid regions of the anterior-septal coaptation line and 6.6 ± 3.2 and 3.8 ± 2.1 mm in the central and mid regions of the septal-posterior coaptation line, respectively. From the right ventricular inflow/outflow view, the coaptation gap measured 4.7 ± 2.4, 5.2 ± 2.4, and 4.6 ± 3.0 mm in the anterior, mid, and posterior regions of the tricuspid valve, respectively. Thirty-day TR reduction (by number of grades) was similar among subjects with coaptation gaps of <7 mm, 7 to 10 mm, and >10 mm. CONCLUSION: A broad range of anatomies was observed in this postmarket population. Characterization of the tricuspid valve and coaptation gap will help to better understand and better define the target patient population for tricuspid TEER therapy.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estudios Prospectivos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Cateterismo Cardíaco , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología
5.
J Am Coll Cardiol ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38759905

RESUMEN

BACKGROUND: Severe tricuspid regurgitation (TR) is known to be associated with poor quality of life and increased risk of death when left untreated. OBJECTIVES: To report the 1-year clinical outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair (TEER) with the TriClip system in a contemporary, real-world setting. METHODS: The bRIGHT post-approval study is a prospective, single-arm, open-label, multicenter, post-market registry conducted at 26 sites in Europe with central event adjudication and echocardiographic core-lab assessment. RESULTS: Enrolled subjects were elderly (79±7 years) with significant comorbidities. Eighty-eight percent had baseline massive or torrential TR and 80% percent of subjects were in NYHA class III/ IV. TR was reduced to moderate or less in 81% at 1 year. Significant improvements in NYHA class (21% to 75% I/II, P<0.0001) and KCCQ score (19±26-point improvement, P<0.0001) were observed at 1 year. One-year mortality was significantly lower in subjects who achieved moderate or lower TR at 30 days; however, there was no difference in mortality among subjects that achieved moderate, mild, or trace TR at 30 days. In addition to TR reduction at 30 days, baseline serum creatinine and baseline RV TAPSE were independently associated with mortality at 1 year (OR: 2.169, 95% CI: [1.494, 3.147], P<0.0001; OR: 0.636, 95% CI: [0.415, 0.974], P=0.0375). Mortality was not associated with baseline TR grade, nor with center volume. CONCLUSIONS: Tricuspid TEER using the TriClip system was safe and effective through 1 year for subjects with significant TR and advanced disease in a diverse, real-world population.

6.
PLoS One ; 19(5): e0302793, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739601

RESUMEN

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Asunto(s)
Algoritmos , Gasto Cardíaco , Ecocardiografía Doppler , Análisis de la Onda del Pulso , Humanos , Masculino , Femenino , Gasto Cardíaco/fisiología , Anciano , Análisis de la Onda del Pulso/métodos , Ecocardiografía Doppler/métodos , Persona de Mediana Edad , Anciano de 80 o más Años , Oscilometría/métodos
7.
Curr Heart Fail Rep ; 10(4): 285-95, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24158384

RESUMEN

Both cardiovascular and renal diseases are common and frequently coexist in the same patient. Indeed, renal dysfunction has been shown to be a more powerful independent predictor of poor outcomes in heart failure (HF) than left ventricular ejection fraction or functional class. Furthermore, acute kidney injury is a frequent therapeutic concern in heart failure. Consequently, there has been much interest in developing new renoprotective treatments and novel biomarkers to monitor renal function. Additionally, given the crucial cardiorenal interaction and interdependence, the concept of a cardiorenal syndrome with five different subtypes has been advanced to better categorize patients and facilitate research.


Asunto(s)
Insuficiencia Cardíaca/epidemiología , Enfermedades Renales/epidemiología , Lesión Renal Aguda/epidemiología , Biomarcadores/sangre , Síndrome Cardiorrenal/epidemiología , Comorbilidad , Progresión de la Enfermedad , Diuréticos/uso terapéutico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Hemofiltración , Humanos , Riñón/fisiopatología , Enfermedades Renales/diagnóstico , Enfermedades Renales/fisiopatología , Monitoreo Fisiológico/métodos , Pronóstico
8.
J Cardiovasc Dev Dis ; 10(6)2023 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-37367395

RESUMEN

Transcatheter aortic valve implantation (TAVI) is now a commonly used therapy in patients with severe aortic stenosis, even in those patients at low surgical risk. The indications for TAVI have broadened as the therapy has proven to be safe and effective. Most challenges associated with TAVI after its initial introduction have been impressively reduced; however, the possible need for post-TAVI permanent pacemaker implantation (PPI) secondary to conduction disturbances continues to be on the radar. Conduction abnormalities post-TAVI are always of concern given that the aortic valve lies in close proximity to critical components of the cardiac conduction system. This review will present a summary of noteworthy pre-and post-procedural conduction blocks, the best use of telemetry and ambulatory device monitoring to avoid unnecessary PPI or to recognize the need for late PPI due to delayed high-grade conduction blocks, predictors to identify those patients at greatest risk of requiring PPI, important CT measurements and considerations to optimize TAVI planning, and the utility of the MInimizing Depth According to the membranous Septum (MIDAS) technique and the cusp-overlap technique. It is stressed that careful membranous septal (MS) length measurement by MDCT during pre-TAVI planning is necessary to establish the optimal implantation depth before the procedure to reduce the risk of compression of the MS and consequent damage to the cardiac conduction system.

9.
J Am Coll Cardiol ; 82(4): 281-291, 2023 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-37207923

RESUMEN

BACKGROUND: Severe tricuspid regurgitation (TR) is known to be associated with substantial morbidity and mortality. OBJECTIVES: The authors sought to study the acute outcomes of subjects treated by tricuspid transcatheter edge-to-edge repair with the TriClip system (Abbott) in a contemporary, real-world setting. METHODS: The bRIGHT (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device) postapproval study is a prospective, single-arm, open-label, multicenter, postmarket registry conducted at 26 sites in Europe. Echocardiographic assessment was performed at a core laboratory. RESULTS: Enrolled subjects were elderly (79 ± 7 years of age) with significant comorbidities. Eighty-eight percent had baseline massive or torrential TR, and 80% of subjects were in NYHA functional class III or IV. Successful device implantation occurred in 99% of subjects, and TR was reduced to ≤moderate at 30 days in 77%. Associated significant improvements in NYHA functional class (I/II, 20% to 79%; P < 0.0001) and Kansas City Cardiomyopathy Questionnaire score (19 ± 23 points improvement; P < 0.0001) were observed at 30 days. With baseline TR grade removed as a variable, smaller right atrial volume and smaller tethering distance at baseline were independent predictors of TR reduction to ≤moderate at discharge (OR: 0.679; 95% CI: 0.537-0.858; P = 0.0012; OR: 0.722; 95% CI: 0.564-0.924; P = 0.0097). Fourteen subjects (2.5%) experienced a major adverse event at 30 days. CONCLUSIONS: Transcatheter tricuspid valve repair was found to be safe and effective in treating significant TR in a diverse, real-world population. (An Observational Real-World Study Evaluating Severe Tricuspid Regurgitation Patients Treated With the Abbott TriClip™ Device [bRIGHT]; NCT04483089).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Anciano , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Cateterismo Cardíaco/efectos adversos , Índice de Severidad de la Enfermedad
10.
PLoS One ; 18(12): e0294075, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38096242

RESUMEN

BACKGROUND: Obesity is a global health concern and risk factor for cardiovascular disease. The assessment of central blood pressure (cBP) has been shown to improve prediction of cardiovascular events. However, few studies have investigated the impact of obesity on cBP in adults, and invasive data on this issue are lacking. This study aimed to evaluate cBP differences between patients with and without obesity, identify cBP determinants, and evaluate the accuracy of the algorithm Antares for non-invasive cBP estimation. METHODS: A total of 190 patients (25% female; 39% with BMI ≥30kg/m2; age: 67±12 years) undergoing elective cardiac catheterization were included. cBP was measured invasively and simultaneously estimated non-invasively using the custo screen 400 device with integrated Antares algorithm. RESULTS: No significant cBP differences were found between obese and non-obese patients. However, females, especially those with obesity, had higher systolic cBP compared to males (P<0.05). Multiple regression analysis showed that brachial mean arterial pressure, pulse pressure, BMI, and heart rate predicted cBP significantly (adjusted R2 = 0.82, P<0.001). Estimated cBP correlated strongly with invasive cBP for systolic, mean arterial, and diastolic cBP (r = 0.74-0.93, P<0.001) and demonstrated excellent accuracy (mean difference <5 and SD <8 mmHg). CONCLUSIONS: This study discovered no significant difference in cBP between obese and non-obese patients. However, it revealed higher cBP values in women, especially those with obesity, which requires further investigation. Additionally, the study highlights Antares' effectiveness in non-invasively determining cBP in obese individuals. This could improve the diagnosis and treatment of hypertension in this special patient population.


Asunto(s)
Determinación de la Presión Sanguínea , Hipertensión , Masculino , Adulto , Humanos , Femenino , Persona de Mediana Edad , Anciano , Presión Sanguínea/fisiología , Obesidad/complicaciones , Obesidad/diagnóstico , Técnicas de Diagnóstico Cardiovascular
11.
Eur Heart J Case Rep ; 6(7): ytac280, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35865224

RESUMEN

Background: The axillary artery is an alternative access route for transcatheter aortic-valve implantation (TAVI) in patients who have unfavourable femoral arteries as well as comorbidities which preclude surgery. Transaxillary TAVI (TAx-TAVI), with a complete non-transfemoral approach, is a feasible and safe alternative even if complications like vascular closure device failure with bleeding occurs. Case summary: We describe here a simplified non-transfemoral TAx-TAVI approach in a 71-year-old patient with pulmonary oedema due to severe symptomatic aortic stenosis with a prohibitively high surgical risk (Society of Thoracic Surgeons Mortality 11.9%) and extensive peripheral artery disease that rendered the femoral arteries unsuitable for access. Importantly, this strategy also allows for successful management of bleeding events, particularly those associated with vascular closure device failure, by the use of a new covered stent device. The patient was discharged on Day 6 after admission in stable conditions. In short-term follow-up (30 days), he is asymptomatic with normal left-ventricular function. Discussion: The TAx-TAVI is a promising alternative to transfemoral TAVI approach. Patient safety, even during bleeding complications, can be guaranteed with appropriate preparation.

12.
Interact Cardiovasc Thorac Surg ; 34(2): 167-175, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34601608

RESUMEN

OBJECTIVES: This study sought to report the calcification pattern of the mitral valve annulus and its implications for procedural and safety outcomes in transcatheter aortic valve implantation. METHODS: Between November 2018 and September 2019, a total of 305 patients had transcatheter aortic valve implants at our institution. The extent of calcification of the mitral valve annulus was analysed, and the impact on safety outcomes was evaluated. RESULTS: The prevalence of mitral annular calcification (MAC) was 43%. Calcification of the mitral valve annulus was either less than or at least one-third of the posterior annulus (34% and 32%), the whole posterior annulus (28%) or the extension to the attachment of the anterior leaflets (7%). Severe circumferential MAC revealed moderate paravalvular leaks in 5/8 (63%) patients and was associated with right branch bundle block [odds ratio (OR) 2.01 (0.39-3.06); P = 0.098] and low cardiac output [OR 3.12 (1.39-7.04); P = 0.033]. Subannular calcification at the anterolateral trigonum represented a risk factor for left ventricular outflow tract injury [OR 3.54 (1.38-8.27); P = 0.001] in balloon-expandable valves, associated with relevant rhythm disorders [OR 2.26 (1.17-5.65); P = 0.014] and female gender (7/8, 88%). The 30-day all-cause mortality in circumferential MAC reaching into the anterior annulus (grade IV) compared to patients with less MAC (grade I-III) was 13% vs 2% with a mean valve size of 24.6 vs 25.7 mm. CONCLUSIONS: Extensive MAC was associated with moderate paravalvular leaks, with implications for the prosthesis size and survival in transcatheter aortic valve implants. In severe MAC, we recommend implanting oversized self-expandable prostheses, the goal being to reduce the risk of right branch bundle block and paravalvular leaks. SUBJ COLLECTION: 122, 125.


Asunto(s)
Estenosis de la Válvula Aórtica , Calcinosis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/complicaciones , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
Egypt Heart J ; 74(1): 19, 2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35347466

RESUMEN

BACKGROUND: Transcatheter mitral valve-in-valve (TMVIV) or valve-in-ring (TMVIR) replacement offer an alternative therapy for high risk patients. We aimed to highlight the operative and postoperative results of TMVIV and TMVIR procedures. RESULTS: We included all patients underwent TMVIV and TMVIR procedures between 2017 and 2020 at two heart centers in Germany. We included a total of 36 high risk patients in our study where 12 received TMVIV and 24 received TMVIR. All patients underwent TMVIV or TMVIR with Edwards Sapien XT or S3 transcatheter valves (Edwards Lifesciences). The mean age was 79 (75-83 years old). The median (IQR) preoperative STS score was 9 (7-13)% and EuroSCORE II was 14.5% (12-16). The majority of our patients were operated via transapical approach (n = 26) and the minority via transseptal approach (n = 10). Out of our records, none of our patients required reopening for bleeding or any other surgical complications. None of our patients required reintervention during the 6 months follow-up period. One mortality was recorded on fifth postoperative day due to low cardiac output syndrome (obviously because of LVOT obstruction by the anterior mitral leaflet). The average blood loss was 200 ml in the first 24 h in patients underwent transapical approach. Average operative time was 93 min and all patients were immediately extubated after the procedure in the operating room (even the patient with echocardiographically documented LVOT obstruction who died on the fifth postoperative day). Length of Intensive Care Unit stay was 2 ± 1.2 days and length of hospital stay was 4.1 ± 1.2 days. In the follow up period, echocardiograms showed normal prosthetic valve function with low transvalvular gradients, no LVOT obstruction in TMVIR cases and no evidence of valve migration or thrombosis (except in one patient). Concerning 6 months readmission, it was recorded in 2 patients due to right sided heart failure symptoms due to preexisting high degree of tricuspid valve regurge which did not disappear or even decrease after the operation and the other patient due to gastrointestinal bleeding. CONCLUSIONS: TMVIV and TMVIR offer an efficient, safe and less invasive alternative in high surgical risk patients.

14.
Eur J Cardiothorac Surg ; 60(2): 253-260, 2021 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-33637994

RESUMEN

OBJECTIVES: Aortic wall thrombus (AWT) can affect suitability to endovascular repair, while its most aggressive entity is better known as shaggy aorta syndrome. Primary objective was to study the procedural and clinical outcome with regard to atherothrombotic AWT in transfemoral aortic valve implantation. METHODS: In a retrospective, single-centre analysis, a qualitative 0-10 AWT score classification system was used. The most severely affected aortic area in computed tomography angiography cross-section was assessed for the number of affected segments, thrombus type, thickness, area and circumference. Primary endpoints were 30-day mortality, neurologic, renal and pulmonary events and signs of solid organ infarction. RESULTS: Between November 2017 and September 2019, 604 patients underwent transfemoral transcatheter aortic valve implantation in our institution. Computed tomography-guided analysis revealed AWT in 11.3% and shaggy aorta syndrome in 6 patients (1.0% with 83.3% male). AWT was mainly present in the descending thoracic and abdominal aorta and was associated with acute renal failure (11.8% vs 3.2%, P ≤ 0.001) and a seven-fold increased rate of disabling peri-interventional stroke (4.4% vs 0.6%, P ≤ 0.001). In all patients with disabling peri-interventional stroke a balloon-expandable prosthesis was used (P ≤ 0.001). In case of shaggy aorta, mortality was more than six-fold increased (2.8% vs 16.7%, P = 0.046). CONCLUSIONS: Severe and irregular thrombus of the descending thoracic and abdominal aorta has been strongly associated with acute respiratory failure and peri-interventional stroke in transfemoral aortic valve implantation, being more likely using balloon-expandable devices. Our results imply important changes with regard to device design and present international transcatheter aortic valve implantation guidelines.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Aorta , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
15.
Egypt Heart J ; 73(1): 79, 2021 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-34519928

RESUMEN

BACKGROUND: Percutaneous mitral valve (MV) clipping for mitral regurgitation (MR) revolutionized MV repair; however, valve anatomies and pathologies vary. Often multiple clips are required, and predicting this pre-procedurally would be useful. We evaluated pre-procedural predictors for multiple clips. RESULTS: We retrospectively analyzed 127 severe MR patients treated by mitral clipping between January 2011 and August 2018. Patients were grouped according to the use of a single (group I) or multiple clips (group II) and pre-procedure echocardiographs compared. No demographic differences existed except group II had more males (68.1%) than group I (48.3%). Mean left atrial diameter was larger in group II, 51 ± 9 mm, than group I, 48 ± 5 mm, p = 0.026. Mean mitral annular diameter differed: 34 ± 4mm (group II) versus 33 ± 3 mm (group I), p = 0.017. The vena contracta was broader in group II than group I (6.6 ± 1 mm vs. 6 ± 0.9 mm, p = 0.001). Severe mitral annular calcification occurred more in group I (36.2%) than group II (10.1%), p = 0.0001. On multivariate analysis, vena contracta width correlated positively with multiple clips (B 0.125, p = 0.013), but severe annular calcification correlated inversely (B - 0.35, p = 0.002). CONCLUSIONS: Vena contracta width and severe annular calcification are factors to consider when planning MV clipping.

16.
J Interv Card Electrophysiol ; 60(3): 521-528, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32415555

RESUMEN

INTRODUCTION: Single-shot devices have been developed to simplify pulmonary vein isolation (PVI). Randomized studies of the second-generation cryoballoon (CB 2nd) demonstrated excellent results. There are limited data comparing results of circular pulmonary vein ablation catheter (PVAC) with conventional RF ablation or CB for PVI. OBJECTIVE: Using a sequential registry cohort and a prospective randomized study, we aimed to compare the acute and long-term results of CB 2nd and PVAC Gold. METHODS: In the registry, consecutive patients with paroxysmal atrial fibrillation (AF) undergoing their first PVI were included. The preferred method used was PVAC Gold in 2014 and CB 2nd in 2015. Subsequently, a randomized study (PVAC vs. CB 2nd) was performed. Ablation success was measured as freedom of AF or atrial tachycardias (AT) off antiarrhythmic drugs. RESULTS: In the registry cohort, PVAC Gold was used in 60 patients and CB 2nd in 56 patients (age 66 ± 11 years, 52% male, LAD 43 ± 6). In the randomized study, 20 patients were treated with PVAC Gold and 22 with CB 2nd (age 67 ± 9; 43% men, LAD 40 ± 7 mm). During a mean follow up of 13.2 ± 3.6 months, success was 54% in PVAC Gold patients and 81% in CB 2nd cases (p = 0.001). In the randomized study 12 months success was 50% versus 86%, p < 0.05. Complications occurred rare in both groups. CONCLUSIONS: Our registry data and the randomized study both suggest superiority of PVI using CB 2nd as compared with PVI using PVAC Gold.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Anciano , Fibrilación Atrial/cirugía , Femenino , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Venas Pulmonares/cirugía , Resultado del Tratamiento
17.
Circulation ; 119(21): 2781-8, 2009 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-19451356

RESUMEN

BACKGROUND: Cinaciguat (BAY 58-2667) is the first of a new class of soluble guanylate cyclase activators in clinical development for acute decompensated heart failure. We aimed to assess the hemodynamic effects, safety, and tolerability of intravenous cinaciguat in patients with acute decompensated heart failure (pulmonary capillary wedge pressure > or =18 mm Hg). METHODS AND RESULTS: After initial dose finding (part A; n=27), cinaciguat was evaluated in the nonrandomized, uncontrolled proof-of-concept part of the study (part B; n=33) using a starting dose of 100 microg/h, which could be titrated depending on hemodynamic response. Patients were categorized as responders if their pulmonary capillary wedge pressure decreased by > or =4 mm Hg compared with baseline. Final doses of cinaciguat after 6 hours of infusion in part B were 50 microg/h (n=2), 200 microg/h (n=12), and 400 microg/h (n=16). Compared with baseline, a 6-hour infusion of cinaciguat led to significant reductions in pulmonary capillary wedge pressure (-7.9 mm Hg), mean right atrial pressure (-2.9 mm Hg), mean pulmonary artery pressure (-6.5 mm Hg), pulmonary vascular resistance (-43.4 dynes . s . cm(-5)), and systemic vascular resistance (-597 dynes . s . cm(-5)), while increasing heart rate by 4.4 bpm and cardiac output by 1.68 L/min. The responder rate was 53% after 2 hours, 83% after 4 hours, and 90% after 6 hours. Cinaciguat was well tolerated, with 13 of 60 patients reporting 14 drug-related treatment-emergent adverse events of mild to moderate intensity, most commonly hypotension. CONCLUSIONS: Cinaciguat has potent preload- and afterload-reducing effects, increasing cardiac output. Further investigation of cinaciguat for acute decompensated heart failure is warranted.


Asunto(s)
Benzoatos/uso terapéutico , Guanilato Ciclasa/efectos de los fármacos , Insuficiencia Cardíaca/tratamiento farmacológico , Hemodinámica/efectos de los fármacos , Receptores Citoplasmáticos y Nucleares/efectos de los fármacos , Vasodilatadores/uso terapéutico , Enfermedad Aguda , Adulto , Anciano , Anciano de 80 o más Años , Benzoatos/administración & dosificación , Benzoatos/efectos adversos , Benzoatos/farmacología , Presión Sanguínea/efectos de los fármacos , Gasto Cardíaco/efectos de los fármacos , Activación Enzimática/efectos de los fármacos , Femenino , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Hipotensión/inducido químicamente , Infusiones Intravenosas , Masculino , Persona de Mediana Edad , Presión Esfenoidal Pulmonar/efectos de los fármacos , Guanilil Ciclasa Soluble , Resistencia Vascular/efectos de los fármacos , Vasodilatadores/administración & dosificación , Vasodilatadores/efectos adversos , Vasodilatadores/farmacología
18.
J Clin Invest ; 116(9): 2552-61, 2006 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-16955146

RESUMEN

ROS are a risk factor of several cardiovascular disorders and interfere with NO/soluble guanylyl cyclase/cyclic GMP (NO/sGC/cGMP) signaling through scavenging of NO and formation of the strong oxidant peroxynitrite. Increased oxidative stress affects the heme-containing NO receptor sGC by both decreasing its expression levels and impairing NO-induced activation, making vasodilator therapy with NO donors less effective. Here we show in vivo that oxidative stress and related vascular disease states, including human diabetes mellitus, led to an sGC that was indistinguishable from the in vitro oxidized/heme-free enzyme. This sGC variant represents what we believe to be a novel cGMP signaling entity that is unresponsive to NO and prone to degradation. Whereas high-affinity ligands for the unoccupied heme pocket of sGC such as zinc-protoporphyrin IX and the novel NO-independent sGC activator 4-[((4-carboxybutyl){2-[(4-phenethylbenzyl)oxy]phenethyl}amino) methyl [benzoic]acid (BAY 58-2667) stabilized the enzyme, only the latter activated the NO-insensitive sGC variant. Importantly, in isolated cells, in blood vessels, and in vivo, BAY 58-2667 was more effective and potentiated under pathophysiological and oxidative stress conditions. This therapeutic principle preferentially dilates diseased versus normal blood vessels and may have far-reaching implications for the currently investigated clinical use of BAY 58-2667 as a unique diagnostic tool and highly innovative vascular therapy.


Asunto(s)
Benzoatos/farmacología , Vasos Sanguíneos/fisiología , Endotelio Vascular/fisiología , Guanilato Ciclasa/fisiología , Receptores Citoplasmáticos y Nucleares/fisiología , Animales , Benzoatos/síntesis química , Presión Sanguínea/efectos de los fármacos , Técnicas de Cultivo de Célula , GMP Cíclico/metabolismo , Endotelio Vascular/citología , Endotelio Vascular/efectos de los fármacos , Guanilato Ciclasa/efectos de los fármacos , Hemo , Oxidación-Reducción , Estrés Oxidativo/efectos de los fármacos , Estrés Oxidativo/fisiología , Arteria Pulmonar , Ratas , Ratas Endogámicas SHR , Ratas Wistar , Especies Reactivas de Oxígeno/metabolismo , Receptores Citoplasmáticos y Nucleares/efectos de los fármacos , Guanilil Ciclasa Soluble , Porcinos , Vasodilatación
19.
Handb Exp Pharmacol ; (191): 485-506, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19089342

RESUMEN

Heart failure (HF) is a common disease that continues to be associated with high morbidity and mortality warranting novel therapeutic strategies. Cyclic guanosine monophosphate (cGMP) is the second messenger of several important signaling pathways based on distinct guanylate cyclases (GCs) in the cardiovascular system. Both the nitric oxide/soluble GC (NO/sGC) as well as the natriuretic peptide/GC-A (NP/GC-A) systems are disordered in HF, providing a rationale for their therapeutic augmentation. Soluble GC activation with conventional nitrovasodilators has been used for more than a century but is associated with cGMP-independent actions and the development of tolerance, actions which novel NO-independent sGC activators now in clinical development lack. Activation of GC-A by administration of naturally occurring or designer natriuretic peptides is an emerging field, as is the inhibition of enzymes that degrade endogenous NPs. Finally, inhibition of cGMP-degrading phosphodiesterases, particularly phosphodiesterase 5 provides an additional strategy to augment cGMP-signaling.


Asunto(s)
GMP Cíclico/metabolismo , Insuficiencia Cardíaca/tratamiento farmacológico , Péptidos Natriuréticos/metabolismo , Animales , Activadores de Enzimas/farmacología , Inhibidores Enzimáticos/farmacología , Guanilato Ciclasa/efectos de los fármacos , Guanilato Ciclasa/metabolismo , Insuficiencia Cardíaca/fisiopatología , Humanos , Óxido Nítrico/metabolismo , Inhibidores de Fosfodiesterasa/farmacología , Receptores Citoplasmáticos y Nucleares/efectos de los fármacos , Receptores Citoplasmáticos y Nucleares/metabolismo , Transducción de Señal , Guanilil Ciclasa Soluble
20.
Acta Cardiol ; 64(3): 329-34, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19593942

RESUMEN

OBJECTIVE: The development of left ventricular remodelling (LVR) after acute myocardial infarction (AMI) is a predictor of heart failure and mortality. The extracellular matrix (ECM) is highly susceptible to ischaemic injury. Laminin and collagen type VI (CVI) contribute to ECM formation in the infarct zone. To determine whether these markers can be detected in blood samples, we measured laminin and CVI in patients with AMI and control subjects. METHODS: A total of 60 patients scheduled for coronary angiography and 31 patients with AMI were included. We subdivided the patients into three groups: (1) AMI, (2) stable coronary artery disease (CAD) and (3) exclusion of CAD. Laminin and CVI serum concentrations were recorded using the ELISA-technique. RESULTS: Laminin was significantly higher in patients with AMI than in subjects with stable CAD (36.5 vs. 23.9, P < 0.01) or without CAD (36.5 vs. 24.6 ng/ml, P < 0.05). CVI-levels were significantly elevated in patients with AMI compared to subjects without CAD (7.5 ng/ml vs. 5.4 ng/ml, P < 0.05) or stable CAD (7.5 ng/ml vs. 5.7 ng/ml, P = 0.01). Laminin and CVI were significantly higher in patients with severely reduced left ventricular function. Laminin and CVI values were significantly correlated (r = 0.6). CONCLUSION: Our data suggest that laminin and CVI serum levels can be potential surrogate parameters of ECM remodelling after AMI. We hypothesize that serum laminin reflects early ECM-remodelling involved in the process of postischaemic tissue degradation and repair, and CVI may be a marker of collagen denaturation and shifts in the collagen phenotype ratios.


Asunto(s)
Colágeno Tipo VI/sangre , Hipertrofia Ventricular Izquierda/sangre , Laminina/sangre , Infarto del Miocardio/sangre , Remodelación Ventricular , Biomarcadores , Estudios de Casos y Controles , Colágeno Tipo VI/biosíntesis , Enfermedad de la Arteria Coronaria/sangre , Femenino , Humanos , Hipertrofia Ventricular Izquierda/fisiopatología , Laminina/biosíntesis , Masculino , Persona de Mediana Edad , Infarto del Miocardio/fisiopatología , Isquemia Miocárdica/sangre , Isquemia Miocárdica/fisiopatología , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA