Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Obstet Gynaecol Can ; 36(7): 598-604, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25184978

RESUMEN

OBJECTIVE: To determine the effectiveness of portable lactate analyzers in identifying fetal acidosis by correlating arterial and venous lactate values from umbilical cord blood with lactate, pH, and base excess measurements from central laboratory analyzers. METHODS: We performed a prospective study using arterial and venous cord blood from 52 women with a singleton fetus delivered at term. We evaluated the correlation between the cord blood lactate concentration measured using two of the same portable devices (Lactate Plus, Nova Biomedical) with the result from a central laboratory analyzer. Analyses of the correlation between arterial lactate concentration measured on the portable device with arterial pH and base excess were then performed. RESULTS: We observed a median arterial pH of 7.24 (range 7.05 to 7.35) and a median arterial lactate concentration of 3.7 mmol/L (range 1.7 to 8.8 mmol/L). An excellent correlation was observed between lactate concentrations measured by the two portable devices (arterial R² = 0.98 and venous R² = 0.98), and between the portable device and the central laboratory analyzer (arterial R² = 0.94 and venous R² = 0.95). In our population, the optimal cut-offs to predict a pH < 7.20 or a base excess > -8.0 mmol/L were a lactate concentration of 4.9 mmol/L and 5.3 mmol/L, respectively, according to receiver operator characteristic analysis. With a lactate concentration > 4.9 mmol/L, the portable device had a sensitivity of 82% and a specificity of 90% to identify samples with an arterial pH < 7.20. CONCLUSION: Cord blood lactate concentration measured with a portable device is a good predictor of cord blood base excess and pH. Future studies should be designed to correlate scalp blood lactate measurements with clinical outcomes.


Objectif : Déterminer l'efficacité des analyseurs de lactate portatifs, pour ce qui est de l'identification de l'acidose fœtale, en mettant en corrélation les valeurs artérielle et veineuse du lactate constatées dans le sang de cordon ombilical et les mesures du lactate, du pH et de l'excès de bases révélées par les analyseurs du laboratoire central. Méthodes : Nous avons mené une étude prospective en utilisant le sang de cordon artériel et veineux prélevé chez 52 femmes qui ont connu une grossesse monofœtale s'étant soldée en un accouchement à terme. Nous avons évalué la corrélation entre la concentration en lactate du sang de cordon mesurée au moyen de deux exemplaires du même appareil portatif (Lactate Plus, Nova Biomedical) et le résultat obtenu au moyen d'un analyseur du laboratoire central. Nous avons par la suite procédé à des analyses de la corrélation entre la concentration artérielle en lactate mesurée au moyen de l'appareil portatif et les valeurs artérielles du pH et de l'excès de bases. Résultats : Nous avons constaté un pH artériel médian de 7,24 (plage : 7,05 - 7,35) et une concentration artérielle en lactate médiane de 3,7 mmol/l (plage : 1,7 - 8,8 mmol/l). Une excellente corrélation a été constatée entre les concentrations en lactate mesurées par les deux appareils portatifs (R2 artériel = 0,98 et R2 veineux = 0,98) et entre les concentrations mesurées par l'appareil portatif et par l'analyseur du laboratoire central (R2 artériel = 0,94 et R2 veineux = 0,95). Au sein de notre population, les seuils optimaux permettant de prédire un pH < 7,20 ou un excès de bases > −8,0 mmol/l ont été des concentrations en lactate de 4,9 mmol/l et de 5,3 mmol/l, respectivement, selon l'analyse de la fonction d'efficacité du récepteur. En présence d'une concentration en lactate > 4,9 mmol/l, l'appareil portatif comptait une sensibilité de 82 % et une spécificité de 90 % pour ce qui est de l'identification des prélèvements présentant un pH artériel < 7,20. Conclusion : La concentration en lactate du sang de cordon qui est mesurée au moyen d'un appareil portatif constitue un bon facteur prédictif pour ce qui est du pH et de l'excès de bases du sang de cordon. De futures études devraient être conçues de façon à pouvoir mettre en corrélation les concentrations en lactate dans le sang prélevé sur le cuir chevelu et les résultats cliniques.


Asunto(s)
Acidosis/diagnóstico , Sangre Fetal/metabolismo , Enfermedades Fetales/diagnóstico , Ácido Láctico/sangre , Diagnóstico Prenatal/instrumentación , Diagnóstico Prenatal/métodos , Humanos , Concentración de Iones de Hidrógeno , Estudios Prospectivos , Sensibilidad y Especificidad
2.
J Appl Lab Med ; 6(2): 409-420, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32989467

RESUMEN

BACKGROUND: Serum is commonly used for clinical chemistry testing but many conditions can affect the clotting process, leading to poor sample quality and impaired workflow. With serum gel tubes, we found a high proportion of sample probe aspiration errors on our Beckman AU5800 analyzers. We decided to implement the BD Barricor™ plasma tubes, and we validated an off-specification centrifugation scheme and verified that results obtained for 65 chemistry and immunochemistry tests were comparable to those obtained in serum gel tubes. Finally, we evaluated the impact of this new tube on sample error rate and laboratory turnaround time. METHODS: To validate centrifugation settings, 50 paired samples were collected in Barricor tubes and centrifuged at 1912 × g for 10 min or 5 min (off-specification). To compare serum gel tubes with Barricor plasma tubes, 119 paired samples were collected from volunteers and results were analyzed using weighed Deming regression. Finally, the proportion of aspiration errors and laboratory TAT for potassium were measured before and after implementing Barricor tubes. RESULTS: Barricor tubes showed clinically acceptable equivalence to serum gel tubes for the studied analytes, and the off-specification centrifugation scheme did not affect the results. Implementing Barricor tubes improved the laboratory workflow by decreasing the aspiration error rates (2.01% to 0.77%, P < 0.001) and lowering hemolysis (P < 0.001). The laboratory TAT for potassium were also significantly lowered (P < 0.001). CONCLUSION: Use of Barricor tubes instead of serum gel tubes leads to better sample quality, shorter more reproducible laboratory TAT, and decreases costs associated with error management.


Asunto(s)
Recolección de Muestras de Sangre , Plasma , Centrifugación , Hemólisis , Hospitales , Humanos
3.
Atherosclerosis ; 197(1): 118-24, 2008 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17399720

RESUMEN

In the French Canadian population six mutations appear to be responsible for about 85% of FH cases. Two of these mutations are large deletions. The most prevalent deletion is a >15 kb deletion of the promoter and first exon; the second, a 5 kb deletion that removes exons 2 and 3. The high frequency of these deletions in the French Canadian population has been attributed to a founder effect. Other mutations are present in the population but at a much lower prevalence. We recently identified two new large deletions in FH patients of French Canadian descent. Carriers of the new deletions were identified because of an unusual pattern of band migration on Southern blots. We have identified and sequenced the deletions' boundaries. The first deletion covers 3813 bp and removes exons 7 and 8. The second deletion covers 5994 bp and removes exons 3-6. These deletions have not been previously reported. They would have been missed if a PCR-based method had been used instead of Southern blot analysis.


Asunto(s)
Análisis Mutacional de ADN , Eliminación de Gen , Hiperlipoproteinemia Tipo II/etnología , Hiperlipoproteinemia Tipo II/genética , Adulto , Southern Blotting , Exones/genética , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ontario/epidemiología , Reacción en Cadena de la Polimerasa , Prevalencia , Mapeo Restrictivo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA