Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 39(28): 2625-2634, 2018 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-29718148

RESUMEN

In the 16 years since the first pioneering procedure, transcatheter aortic valve implantation (TAVI) has come of age and become a routine strategy for aortic valve replacement, increasingly performed under conscious sedation via transfemoral access. Simplification of the procedure, accumulation of clinical experience, and improvements in valve design and delivery systems have led to a dramatic reduction in complication rates. These advances have allowed transition to lower risk populations, and outcome data from the PARTNER 2A and SURTAVI trials have established a clear evidence base for use in intermediate risk patients. Ongoing studies with an expanding portfolio of devices seem destined to expand indications for TAVI towards lower risk, younger and asymptomatic populations. In this article, we outline recent advances, new devices and current guidelines informing the use of TAVI, and describe remaining uncertainties that need to be addressed.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Predicción , Humanos , Complicaciones Posoperatorias/epidemiología , Guías de Práctica Clínica como Asunto , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
2.
Catheter Cardiovasc Interv ; 92(4): 637-643, 2018 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-29521440

RESUMEN

Increasing evidence suggests that percutaneous coronary intervention with newer generation drug-eluting stents may be an acceptable alternative, or even preferred in selected cases to the surgical approach, in patients with left main disease. This review will discuss the anatomic factors, the clinical variables, and the procedural strategies to consider, including physiology assessment and imaging guidance, in order to optimize outcomes.


Asunto(s)
Toma de Decisiones Clínicas , Enfermedad de la Arteria Coronaria/terapia , Selección de Paciente , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Stents Liberadores de Fármacos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Factores de Riesgo , Resultado del Tratamiento
3.
Neth Heart J ; 25(10): 536-544, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28741245

RESUMEN

Heart failure has a high prevalence in the general population. Morbidity and mortality of heart failure patients remain high, despite improvements in drug therapy, implantable cardioverter-defibrillators and cardiac resynchronisation therapy. New transcatheter implantable devices have been developed to improve the treatment of heart failure. There has been a rapid development of minimally invasive or transcatheter devices used in the treatment of heart failure associated with aortic and mitral valve disease and these devices are being incorporated into routine clinical practice at a fast rate. Several other new transcatheter structural heart interventions for chronic heart failure aimed at a variety of pathophysiologic approaches are currently being developed. In this review, we focus on devices used in the treatment of chronic heart failure by means of left ventricular remodelling, left atrial pressure reduction, tricuspid regurgitation reduction and neuromodulation. The clinical evaluations of these devices are early-stage evaluations of initial feasibility and safety studies and additional clinical evidence needs to be gathered in appropriately designed clinical trials.

4.
Minerva Cardioangiol ; 61(3): 255-62, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23681128

RESUMEN

Bioresorbable scaffold technology has evol-ved over the last few years with a number of devices either available or under clinical and preclinical investigation. The absence of a permanent metallic segment in the treated vessel wall has the potential of addressing some of the issues still encountered with metallic drug-eluting stents (DES) despite improvements in stent platform, polymer and drug elution. To date however, the use of bioresorbable vascular scaffolds (BVS) has largely been restricted to patients recruited into clinical trials with a relatively small number of "real-world" patients treated with these devices. Here we explore the issue of BVS use in "real-world" patients and try to identify, on the basis of our experience, the subset of patients that could benefit the most.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Infarto del Miocardio/terapia , Stents , Andamios del Tejido , Anciano , Angioplastia Coronaria con Balón/métodos , Ensayos Clínicos como Asunto , Estudios de Cohortes , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico por imagen , Diseño de Prótesis , Radiografía , Factores de Riesgo , Resultado del Tratamiento
5.
J Frailty Aging ; 12(1): 7-15, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36629078

RESUMEN

BACKGROUND: Intrinsic capacity (IC) and frailty are complementary in advancing disability prevention through maintaining functionality. OBJECTIVES: We examined the relationship between IC and frailty status at baseline and 1-year, and evaluated if IC decline predicts frailty onset among robust older adults. The secondary objectives investigated associations between IC, physical fitness and health-related outcomes. DESIGN: Prospective cohort study. SETTING: Community-based assessments. PARTICIPANTS: Older adults aged>55 years, who were independent in ambulation (walking aids permitted). MEASUREMENTS: 5 domains of IC were assessed at baseline: locomotion (Short Physical Performance Battery, 6-minute walk test), vitality (nutritional status, muscle mass), sensory (self-reported hearing and vision), cognition (self-reported memory, age- and education adjusted cognitive performance), psychological (Geriatric Depression Scale-15, self-reported anxiety/ depression). Composite IC (0-10) was calculated, with higher scores representing greater IC. Frailty status was based on modified Fried criteria, with frailty progression defined as incremental Fried score at 1-year. RESULTS: 809 participants (67.6+6.8 years) had complete data for all 5 IC domains. 489 (60.4%) participants were robust but only 213 (26.3%) had no decline in any IC domain. Pre-frail and frail participants were more likely to exhibit decline in all 5 IC domains (p<0.05), with decremental composite IC [9 (8-9), 8 (6-9), 5.5 (4-7.5), p<0.001] across robust, prefrail and frail. IC was significantly associated with fitness performance, independent of age and gender. Higher composite IC reduced risk for frailty progression (OR=0.62, 95% CI 0.48-0.80), and reduced frailty onset among robust older adults (OR=0.53, 95% CI 0.37-0.77), independent of age, comorbidities and social vulnerability. Participants with higher IC were less likely to experience health deterioration (OR=0.70, 95% CI 0.58-0.83), falls (OR=0.76, 95% CI 0.65-0.90) and functional decline (OR=0.64, 95% CI 0.50-0.83) at 1-year. CONCLUSION: Declining IC may present before frailty becomes clinically manifest, increasing risk for poor outcomes. Monitoring of IC domains potentially facilitates personalized interventions to avoid progressive frailty.


Asunto(s)
Fragilidad , Anciano , Humanos , Fragilidad/diagnóstico , Fragilidad/epidemiología , Fragilidad/complicaciones , Vida Independiente , Anciano Frágil/psicología , Estudios Prospectivos , Evaluación Geriátrica , Aptitud Física , Evaluación de Resultado en la Atención de Salud
6.
Vasa ; 41(4): 292-4, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22825864

RESUMEN

A 64-year old diabetic male presenting with critical limb ischemia was treated with percutaneous angioplasty for occlusion of the infragenicular popliteal artery and crural vessels. Directional atherectomy was uncommonly used in the false lumen created by following subintimal angioplasty of the infrapopliteal vessels for re-access into the true lumen. The positive clinical and angiographic results indicate that atherectomy can be considered a useful tool for rescue interventions to reopen large side branches unintentionally occluded during subintimal angioplasty.


Asunto(s)
Angioplastia de Balón/métodos , Aterectomía/métodos , Angiopatías Diabéticas/terapia , Isquemia/terapia , Recuperación del Miembro , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Constricción Patológica , Enfermedad Crítica , Angiopatías Diabéticas/complicaciones , Angiopatías Diabéticas/diagnóstico por imagen , Humanos , Isquemia/diagnóstico por imagen , Isquemia/etiología , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico por imagen , Arteria Poplítea/diagnóstico por imagen , Radiografía , Resultado del Tratamiento
7.
JAR Life ; 10: 1-7, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-36923514

RESUMEN

Background: Preventing frailty is important to avoid adverse health outcomes. Intervention studies have largely focused on frail elderly, although the intermediate pre-frail state may be more amenable to improvement. Objectives: This study aims to assess how physical performance may change among pre-frail elderly enrolled in a pragmatic non-controlled exercise and nutritional intervention programme. Methods: This is a non-controlled study involving a 4-month exercise and nutritional intervention for community dwelling pre-frail older adults. Pre-frailty was defined as the presence of 1 or 2 positive responses on the FRAIL questionnaire, or evidence of weak grip strength (<26kg for males; <18kg for females) or slow gait speed (<0.8m/s) amongst participants who were asymptomatic on FRAIL. Physical performance in flexibility, grip and lower limb strength, endurance, balance, and Short Physical Performance Battery were measured at 3 time-points: baseline, 3-month from recruitment (without intervention), and immediate post-intervention. Repeated measures mixed model analysis was performed to compare physical performance measures across the 3 time-points. Results: 94 pre-frail participants were eligible for intervention, of whom 59 (mean age = 70.9±7.2 years) were ready for the post-intervention review. 21 (35.6%) transitioned to robust phenotype while 32 (54.2%) remained as pre-frail. Significant improvement post-intervention was observed in lower limb strength and power, evident on reduction in time taken for 5 sit-to-stand repetitions (0.46±0.20s, p=0.03). There was no significant change to the other physical performance measures examined. Conclusion: We observed reversibility of pre-frailty, and the benefit of multi-component intervention in improving physical performance of pre-frail older adults. The findings in this non-controlled study will need to be corroborated with future controlled trials.

8.
Eur Heart J Cardiovasc Imaging ; 21(1): 85-92, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-30977790

RESUMEN

AIM: The aim of this study is to describe our 9-year experience in transcatheter aortic valve replacement (TAVR) using transthoracic echocardiography (TTE) as a routine intra-procedural imaging modality with trans-oesophageal echocardiography (TEE) as a backup. METHODS AND RESULTS: From January 2008 to December 2017, 1218 patients underwent transfemoral TAVR at our Institution. Except the first 20 cases, all procedures have been performed under conscious sedation, with fluoroscopic guidance and TTE imaging monitoring. Once the TTE resulted suboptimal for final result assessment or a complication was either suspected or identified on TTE, TEE evaluation was promptly performed under general anaesthesia. Only 24 (1.9%) cases required a switch to TEE: 6 cases for suboptimal TTE prosthetic valve leak (PVL) quantification; 12 cases for haemodynamic instability; 2 cases for pericardial effusion without haemodynamic instability; 4 cases for urgent TAVR. The 30-days and 1-year all-cause mortality were 2.1% and 10.2%, respectively. Cardiac mortality at 30-days and 1-year follow-up were 0.6% and 4.1%, respectively. Intra-procedural and pre-discharge TT evaluation showed good agreement for PVL quantification (k agreement: 0.827, P = 0.005). CONCLUSION: TTE monitoring seems a reasonable imaging tool for TAVR intra-procedural monitoring without delay in diagnosis of complications and a reliable paravalvular leak assessment. However, TEE is undoubtedly essential in identifying the exact mechanism in most of the complications.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco , Ecocardiografía , Ecocardiografía Transesofágica , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
J Nutr Health Aging ; 24(6): 582-590, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32510110

RESUMEN

OBJECTIVES: Compare the diagnostic performance of FRAIL against Fried Phenotype and Frailty Index (FI), and identify clinical factors associated with pre-frailty/frailty. DESIGN: Cross-sectional analysis. SETTING: Community-based screenings in Senior Activity Centres, Residents' Corners and Community Centres in northeast Singapore. PARTICIPANTS: 517 community dwelling participants aged >55 years and ambulant independently (with/ without walking aids) were included in this study. Residents of sheltered or nursing homes, and seniors unable to ambulate at least four meters independently were excluded. MEASUREMENTS: The multidomain geriatric screen included assessments for social vulnerability, mood, cognition, sarcopenia and nutrition. Participants completed a battery of physical fitness tests for grip strength, gait speed, lower limb strength and power, flexibility, balance and endurance, with overall physical performance represented by Short Physical Performance Battery (SPPB). Frailty status was assigned on FRAIL, Fried and 35-item FI. RESULTS: Prevalence of frailty was 1.3% (FRAIL) to 3.1% (FI). Pre-frailty prevalence ranged from 17.0% (FRAIL) to 51.2% (FI). FRAIL demonstrated poor agreement with FI (kappa=0.171, p<0.0001), and Fried (kappa=0.194, p<0.0001). A lower FRAIL cut-off ≥1 yielded significantly improved AUC of 0.70 (95%CI 0.55 to 0.86, p=0.009) against Fried, and 0.71 (95%CI 0.55 to 0.86, p=0.008) against FI. All 3 frailty measures were diagnostic of impaired physical performance on SPPB, with AUCs ranging from 0.69 on FRAIL to 0.77 on Fried (all p values <0.01). Prevalence of low socio-economic status, depression, malnutrition and sarcopenia increased significantly, while fitness measures of gait speed, balance, and endurance declined progressively across robust, pre-frail and frail on all 3 frailty instruments (p <0.05). CONCLUSIONS: Our results suggest that different frailty instruments may capture over-lapping albeit distinct constructs, and thus may not be used interchangeably. FRAIL has utility for quick screening, and any positive response should trigger further assessment, including evaluation for depression, social vulnerability and malnutrition.


Asunto(s)
Equipo para Diagnóstico/normas , Anciano Frágil/psicología , Fragilidad/psicología , Evaluación Geriátrica/métodos , Vida Independiente/normas , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad
10.
Catheter Cardiovasc Interv ; 74(2): 348-56, 2009 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-19213067

RESUMEN

OBJECTIVES: Preliminary Investigation to the Angiographic Versus IVUS Optimization Trial is a single center prospective observational intravascular ultrasound (IVUS) guided stent implantation study assessing new criteria for optimal drug eluting stent (DES) deployment. BACKGROUND: IVUS assessment of DES often reveals underexpansion and malapposition. Optimal stent deployment is currently poorly defined and previous criteria may not be suitable in long and complex lesions. METHODS: Optimization was defined as achieving >/or 70% of the cross-sectional area (CSA) of the postdilation balloon. This criterion was applied in 113 complex lesions. The size of this balloon was calculated according to vessel media-to-media diameters at various sites inside the stented segment. The IVUS guided treated lesions were matched according to diabetes, vessel type, reference vessel diameter, minimum lumen diameter (MLD), and lesion length with a group of angiographic treated lesions to compare final MLD achieved. RESULTS: Mean minimum stent CSA according to the postdilation balloon utilized was 4.62 mm(2), 6.26 mm(2), 7.87 mm(2), and 9.87 mm(2) for 2.5 mm, 3.0 mm, 3.5 mm, and 4 mm balloons, respectively. Final MLD (mm) was significantly larger in the IVUS compared to the angiographic-guided group (3.09 +/- 0.50 vs. 2.67 +/- 0.54; P < 0.0001). There were no procedural complications related to IVUS use. CONCLUSIONS: We propose new IVUS criteria based on vessel remodeling that results in an increment in the final MLD, compared to angiographic guidance, which is much larger than any previously published study. This criterion seems to be safely achievable. A proposed randomized study (angiographic vs. IVUS optimization trial) has been launched to test these concepts.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Angiografía Coronaria/normas , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Radiografía Intervencional/normas , Ultrasonografía Intervencional/normas , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Proyectos Piloto , Inhibidores de Agregación Plaquetaria/uso terapéutico , Guías de Práctica Clínica como Asunto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Resultado del Tratamiento
11.
Minerva Cardioangiol ; 56(5): 483-91, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18813184

RESUMEN

With the introduction of drug-eluting stents (DES) the problem of restenosis after percutaneous stent implantation was partially resolved. In the first generation of DES a stainless steel platform was coated with a durable polymer eluting and controlling the release of an active restenotic drug. The impairment of re-endothelization after DES implantation, one of the causes of late stent thrombosis, was to some extent attributed to the properties of the durable polymer and/or drug that it eluted. The introduction of biodegradable platforms and biocompatible polymers may potentially address this issue. Modern technologies are being applied to improve the characteristics of biodegradable stents and find new active pharmacological agents or combinations of standard antirestenotic and antithrombotic drugs that can be eluted from the stents, in order to improve their safety profile and clinical utility.


Asunto(s)
Implantes Absorbibles , Materiales Biocompatibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Humanos , Diseño de Prótesis
12.
Minerva Cardioangiol ; 62(1): 39-57, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24500216

RESUMEN

The relationship between diabetes mellitus and coronary artery disease is well established. The percentage of patients participating in clinical trials of percutaneous coronary intervention (PCI) who have diabetes is quickly rising. Diabetic patients have a worse prognosis than non-diabetics, with generally greater rates of death, myocardial infarction and need for target lesion and vessel revascularization. Stenting has improved the outcome of diabetic patients receiving PCI. Compared with bare-metal stents, the use of drug-eluting stents has resulted in a significant reduction in late lumen loss, binary restenosis, and clinically driven target vessel revascularization even in diabetic patients. Although surgical revascularization remains the recommended revascularization strategy for diabetics, particularly in case of multivessel coronary artery disease, recent progress in interventional devices and techniques have resulted in a changing paradigm for coronary artery revascularization. New stent designs, polymers and drugs are resulting in better outcomes overall, but more research is required to define their relative efficacy relative to other treatment options in this complex subgroup of patients.


Asunto(s)
Diabetes Mellitus/fisiopatología , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Polímeros/química , Pronóstico , Diseño de Prótesis
13.
J Cardiovasc Surg (Torino) ; 54(4): 441-5, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24013532

RESUMEN

AIM: This study was designed to investigate the immediate and one-year outcomes of polymer-free paclitaxel coated drug-eluting stent (DES) implantation in a consecutive series of patients presenting with stenosis of infrainguinal bypass grafts. METHODS: Between January 2011 and January 2012, 11 patients with failing infrainguinal bypass grafts were treated in two institutions. Clinical status and Duplex scan parameters were recorded at baseline and over a follow-up period of one year. RESULTS: DES implantation was successfully performed in all patients. Ten patients received a single stent and one patient received two stents. At one year, one patient showed total bypass graft occlusion (9%). In all the remaining patients, Duplex scan examination documented patency of the treated grafts. CONCLUSION: DES implantation in failing infrainguinal bypass grafts can be safely performed and provides satisfactory clinical outcomes. The patency rate of 91% favourably compares with those obtained with other endovascular treatments such as plain balloon or cutting balloon angioplasty.


Asunto(s)
Aleaciones , Angioplastia de Balón/instrumentación , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Fármacos Cardiovasculares/administración & dosificación , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/terapia , Extremidad Inferior/irrigación sanguínea , Paclitaxel/administración & dosificación , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Constricción Patológica , Femenino , Oclusión de Injerto Vascular/diagnóstico , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/fisiopatología , Humanos , Italia , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex , Grado de Desobstrucción Vascular
14.
QJM ; 105(10): 949-57, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22771555

RESUMEN

BACKGROUND: Vit-K antagonists are the therapy of choice to prevent thromboembolic events due to atrial fibrillation since many years. New oral anticoagulants (NOA) showed encouraging results vs. warfarin but there are no data directly comparing different NOA. We performed an adjusted indirect meta-analysis. METHODS: Randomized controlled trials (RCTs) were searched. Efficacy end points were the cumulative rate of thomboembolic stroke (TES) and systemic embolism (SE). Main safety end point was the rate of hemorrhagic stroke (HS). RESULTS: Three RCTs (50578 patients) were included. Overall, NOA were comparable to warfarin according to the cumulative risk of TES and SE, as well as for TES alone. NOA were associated with a reduced rate of SE [OR 0.64 (0.44, 0.94], P=0.02]. Compared to warfarin, NOA were associated with a significantly reduced risk of HS [OR 0.43 (0.34, 0.55), P<0.001, NNT to avoid a HS 153] and all cause death [OR 0.90 [0.84, 0.96], P=0.03, NNT to save one fatality 43]. Head to head comparison showed that in terms of cumulative rate of TES/SE, as well as of TES, none of the NOA was significantly superior to the others (all Ps>0.05). Rivaroxaban showed superiority in the prevention of SE. Dabigatran 150 mg/twice daily was associated with the largest reduction in the risk of HS vs. warfarin and vs. other NOA. Overall mortality was quite comparable across NOA. CONCLUSION: Overall superiority of NOA over warfarin is largely influenced by the reduction of HS. Dabigatran 150 mg/twice daily seems to have the best risk/benefit profile.


Asunto(s)
Anticoagulantes , Fibrilación Atrial/tratamiento farmacológico , Embolia/prevención & control , Accidente Cerebrovascular/prevención & control , Anciano , Anciano de 80 o más Años , Anticoagulantes/administración & dosificación , Anticoagulantes/efectos adversos , Anticoagulantes/clasificación , Fibrilación Atrial/complicaciones , Bencimidazoles/administración & dosificación , Bencimidazoles/efectos adversos , Disponibilidad Biológica , Investigación sobre la Eficacia Comparativa/métodos , Investigación sobre la Eficacia Comparativa/estadística & datos numéricos , Dabigatrán , Monitoreo de Drogas/métodos , Embolia/etiología , Embolia/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Morfolinas/administración & dosificación , Morfolinas/efectos adversos , Evaluación de Procesos y Resultados en Atención de Salud , Farmacovigilancia , Pirazoles/administración & dosificación , Pirazoles/efectos adversos , Piridonas/administración & dosificación , Piridonas/efectos adversos , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo/métodos , Medición de Riesgo/estadística & datos numéricos , Rivaroxabán , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/mortalidad , Tiofenos/administración & dosificación , Tiofenos/efectos adversos , Warfarina/administración & dosificación , Warfarina/efectos adversos , beta-Alanina/administración & dosificación , beta-Alanina/efectos adversos , beta-Alanina/análogos & derivados
15.
Heart ; 95(6): 495-504, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-18812408

RESUMEN

Based on the results of numerous randomised trials, the provisional approach of implanting one stent on the main branch has become the default approach to most bifurcation lesions. However, bifurcation intervention still remains technically challenging. Dedicated bifurcation stents have been designed to specifically treat coronary bifurcations with the aim of dealing with some of the shortcomings of the conventional percutaneous approach to bifurcation intervention. Most of the devices are aimed at facilitating the provisional approach. They are an exciting and innovative technology that may further simplify the management and current approach to bifurcation treatment. Currently, 11 devices are available that have either completed or are currently undergoing First-In-Man trials. The development of more drug-eluting platforms and larger studies with control groups demonstrating their clinical applicability, efficacy and safety are required before they are widely incorporated into daily practice.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Stents , Angioplastia Coronaria con Balón/métodos , Reestenosis Coronaria/prevención & control , Estenosis Coronaria/patología , Stents Liberadores de Fármacos , Humanos , Diseño de Prótesis , Implantación de Prótesis/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA