Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Revista
País de afiliación
Intervalo de año de publicación
1.
Vasa ; 50(3): 186-192, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33559507

RESUMEN

Background: Our aim was to determine the rate of ischemic stroke following thoracic endovascular aortic repair (TEVAR) after reducing gas volume released during stentgraft deployment by de-airing of thoracic stentgrafts with high-volume of 0.9% heparinized saline solution. Patients and methods: A single center retrospective analysis of all consecutive patients undergoing TEVAR from 2014 to 2019 was performed. All thoracic stentgrafts were flushed with 120 ml 0.9% heparinized saline solution before implantation, according to our institutional protocol. Endpoints were in-hospital rates of ischemic stroke and spinal cord ischemia (SCI), and all-cause mortality. Results: One hundred and fifty-four patients (mean age: 66.8 ± 13.6 years, 64.9% males) were treated with TEVAR during the study period. Indications for treatment were thoracic aortic aneurysms (n = 75, 48.7%), acute type B aortic dissections (n = 46, 29.9%), aortic arch aneurysms and penetrating aortic ulcers (n = 28, 18.2%), and blunt traumatic aortic injuries (n = 5, 3.2%). Timing of procedure was urgent in 75 patients (48.7%). Proximal landing zone were zone 0-1-2 (n = 75, 48.7%), zone 3 (n = 66, 42.9%) and zone 4 (n = 13, 8.4%). Supra-aortic vessels were revascularized with custom-made fenestrated stentgrafts in 9 patients (5.8%), using chimney technique in 4 patients (2.6%), and with debranching procedures in 19 patients (12.3%). Left subclavian artery was covered without revascularization in 46 patients (29.9%). In-hospital stroke occurred in two patients (1.3%) and SCI in another two patients (1.3%). In-hospital mortality rate was 0.6%. No further in-hospital events were noted. Conclusions: De-airing of stentgrafts with high-volume of 0.9% heparinized saline solution seems to be safe and can be used as an adjunct to keep occurrence of neurological events after TEVAR as low as possible.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Anciano , Anciano de 80 o más Años , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Solución Salina , Stents , Accidente Cerebrovascular/etiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA