Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 24(11): e14160, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37793084

RESUMEN

The purpose of this guideline is to provide a list of critical performance tests to assist the Qualified Medical Physicist (QMP) in establishing and maintaining a safe and effective quality assurance (QA) program. The performance tests on a linear accelerator (linac) should be selected to fit the clinical patterns of use of the accelerator and care should be given to perform tests which are relevant to detecting errors related to the specific use of the accelerator. Current recommendations for linac QA were reviewed to determine any changes required to those tests highlighted by the original report as well as considering new components of the treatment process that have become common since its publication. Recommendations are made on the acquisition of reference data, routine establishment of machine isocenter, basing performance tests on clinical use of the linac, working with vendors to establish QA tests and performing tests after maintenance and upgrades. The recommended tests proposed in this guideline were chosen based on consensus of the guideline's committee after assessing necessary changes from the previous report. The tests are grouped together by class of test (e.g., dosimetry, mechanical, etc.) and clinical parameter tested. Implementation notes are included for each test so that the QMP can understand the overall goal of each test. This guideline will assist the QMP in developing a comprehensive QA program for linacs in the external beam radiation therapy setting. The committee sought to prioritize tests by their implication on quality and patient safety. The QMP is ultimately responsible for implementing appropriate tests. In the spirit of the report from American Association of Physicists in Medicine Task Group 100, individual institutions are encouraged to analyze the risks involved in their own clinical practice and determine which performance tests are relevant in their own radiotherapy clinics.


Asunto(s)
Radiometría , Planificación de la Radioterapia Asistida por Computador , Humanos , Aceleradores de Partículas , Cintigrafía , Física
2.
J Appl Clin Med Phys ; 21(7): 187-195, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32432389

RESUMEN

PURPOSE: The COVID-19 pandemic has led to disorder in work and livelihood of a majority of the modern world. In this work, we review its major impacts on procedures and workflow of clinical physics tasks, and suggest alternate pathways to avoid major disruption or discontinuity of physics tasks in the context of small, medium, and large radiation oncology clinics. We also evaluate scalability of medical physics under the stress of "social distancing". METHODS: Three models of facilities characterized by the number of clinical physicists, daily patient throughput, and equipment were identified for this purpose. For identical objectives of continuity of clinical operations, with constraints such as social distancing and unavailability of staff due to system strain, however with the possibility of remote operations, the performance of these models was investigated. General clinical tasks requiring on-site personnel presence or otherwise were evaluated to determine the scalability of the three models at this point in the course of disease spread within their surroundings. RESULTS: The clinical physics tasks within three models could be divided into two categories. The former, which requires individual presence, include safety-sensitive radiation delivery, high dose per fraction treatments, brachytherapy procedures, fulfilling state and nuclear regulatory commission's requirements, etc. The latter, which can be handled through remote means, include dose planning, physics plan review and supervision of quality assurance, general troubleshooting, etc. CONCLUSION: At the current level of disease in the United States, all three models have sustained major system stress in continuing reduced operation. However, the small clinic model may not perform if either the current level of infections is maintained for long or staff becomes unavailable due to health issues. With abundance, and diversity of innovative resources, medium and large clinic models can sustain further for physics-related radiotherapy services.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/epidemiología , Física Sanitaria , Pandemias , Neumonía Viral/epidemiología , Oncología por Radiación , COVID-19 , Instituciones de Salud/normas , Personal de Salud , Física Sanitaria/organización & administración , Física Sanitaria/normas , Humanos , Guías de Práctica Clínica como Asunto/normas , Garantía de la Calidad de Atención de Salud , Oncología por Radiación/organización & administración , Oncología por Radiación/normas , SARS-CoV-2 , Estados Unidos/epidemiología
3.
J Appl Clin Med Phys ; 20(1): 194-199, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30586477

RESUMEN

An effective radiotherapy treatment entails maximizing radiation dose to the tumor while sparing the surrounding and normal tissues. With the advent of SBRT with extreme hypo-fractionation in treating tumors including prostate where ablative dose is delivered in smaller number of fractions, rectum remains a dose-limiting organ and at the risk of rectal toxicity or secondary cancer. The same limitation of rectal toxicity exists for high-dose rate (HDR) treatments of cervical, endometrial, or prostate cancer when creating even a short distance between the anterior rectal wall and field of radiation is ideal in delivering ablative dose to the target. An effective solution to such problem is to physically displace rectum as the organ at risk. This research presents an organ retractor device that is designed to displace the rectum away from the path of radiation beam employing a Nitinol shape memory alloy that is designed for displacing the rectum upon actuation. A control system regulates the motion in a reproducible and safe manner by creating the desirable shape in moving the anterior rectal wall. The study finds the novel organ retractor device to be a promising tool that can be applied in a clinical setting for minimizing dose to the rectum during treatment of pelvic tumors, and creating the potential to deliver an ablative dose to tumor volume or to escalate the dose when needed.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias Pélvicas/radioterapia , Neoplasias de la Próstata/radioterapia , Recto/cirugía , Braquiterapia/métodos , Cadáver , Humanos , Masculino , Recto/efectos de la radiación , Instrumentos Quirúrgicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA