Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Sensors (Basel) ; 24(3)2024 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-38339649

RESUMEN

Terahertz (THz) waves are electromagnetic waves in the 0.1 to 10 THz frequency range, and THz imaging is utilized in a range of applications, including security inspections, biomedical fields, and the non-destructive examination of materials. However, THz images have a low resolution due to the long wavelength of THz waves. Therefore, improving the resolution of THz images is a current hot research topic. We propose a novel network architecture called J-Net, which is an improved version of U-Net, to achieve THz image super-resolution. It employs simple baseline blocks which can extract low-resolution (LR) image features and learn the mapping of LR images to high-resolution (HR) images efficiently. All training was conducted using the DIV2K+Flickr2K dataset, and we employed the peak signal-to-noise ratio (PSNR) for quantitative comparison. In our comparisons with other THz image super-resolution methods, J-Net achieved a PSNR of 32.52 dB, surpassing other techniques by more than 1 dB. J-Net also demonstrates superior performance on real THz images compared to other methods. Experiments show that the proposed J-Net achieves a better PSNR and visual improvement compared with other THz image super-resolution methods.

2.
Opt Express ; 27(10): 14695-14704, 2019 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-31163914

RESUMEN

A terahertz continuous wave system is demonstrated for thickness measurement using Gouy phase shift interferometry without frequency sweep. One arm of the interferometer utilizes a collimated wave as a reference, and the other arm applies a focused beam for sample investigation. When the optical path difference (OPD) of the arms is zero, a destructive interference pattern is produced. Interference signal intensity changes induced by the OPD changes can be easily predicted by calculations. By minimizing the difference between the measured and the calculated signal against the OPD, the thicknesses of sub-100-µm-thick samples are determined at 625 GHz.

3.
Nanotechnology ; 29(47): 47LT01, 2018 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-30211691

RESUMEN

Rectifiers have been used to detect electromagnetic waves with very low photon energies. In these rectifying devices, different methods have been utilized, such as adjusting the bandgap and the doping profile, or utilizing the contact potential of the metal-semiconductor junction to produce current flow depending on the direction of the electric field. In this paper, it is shown that the asymmetric application of nano-electrodes to a metal-semiconductor-metal (MSM) structure can produce such rectification characteristics, and a terahertz (THz) wave detector based on the nano-MSM structure is proposed. Integrated with a receiving antenna, the fabricated device detects THz radiation up to a frequency of 1.5 THz with responsivity and noise equivalent power of 10.8 V/W and [Formula: see text] respectively, estimated at 0.3 THz. The unidirectional current flow is attributed to the thermionic emission of hot carriers accelerated by the locally enhanced THz field at the sharp end of the nano-electrode. This work not only demonstrates a new type of THz detector but also proposes a method for manipulating ultrafast charge-carrier dynamics through the field enhancement of the nano-electrode, which can be applied to ultrafast photonic and electronic devices.

4.
Opt Express ; 23(2): 846-58, 2015 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-25835845

RESUMEN

In this study, inspired by the frequency-modulated continuous-wave (FMCW) method, an operation scheme of continuous-wave (CW) terahertz (THz) homodyne system is proposed and evaluated. For this purpose, we utilized the fast and stable wavelength tuning characteristics of a dual-mode laser (DML) as a beating source. Using the frequency-modulated THz waves generated by DML, a cost-effective and robust operation of CW THz system to be applicable to the measurements of thickness or refractive index of a sample is demonstrated. We believe that the proposed scheme shows a potential to the implementations of compact and fast CW THz measurement systems that can be useful in many THz applications.

5.
Nanotechnology ; 26(31): 315203, 2015 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-26183858

RESUMEN

An active terahertz (THz) wave hybrid grating structure of Au/Ti metallic grating on VO2/Al2O3 (0001) was fabricated and evaluated. In our structure, it is shown that the metallic gratings on the VO2 layer strengthen the metallic characteristics to enhance the contrast of the metallic and dielectric phases of a VO2-based device. Especially, the metal grating-induced optical conductivity of the device is greatly enhanced, three times more than that of a metallic phase of bare VO2 films in the 0.1-2.0 THz spectral range. As an illustrative example, we fabricated an actively on/off switchable THz linear polarizer. The fabricated device has shown commercially comparable values in degree of polarization (DOP) and extinction ratio (ER). A high value of 0.89 in the modulation depth (MD) for the transmission field amplitude, superior to other THz wave modulators, is achieved. The experimental results show that the fabricated device can be highly useful in many applications, including active THz linear polarizers, THz wave modulators and variable THz attenuators.

6.
Opt Express ; 22(14): 16738-44, 2014 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-25090492

RESUMEN

We report on the highly sensitive terahertz measurement of a thin, dielectric layer using two channels formed by inserting a single slit sheet in the parallel-plate waveguides (PPWGs). When a thin layer is applied to coat the upper surface of the channel, the single resonance frequency caused by the two-channel PPWGs is shifted as a result of the layer's properties, including length, thickness, and refractive index. The measured frequency tuning sensitivities (FTS) throughout the 20-mm layer length are 2.41 and -1.95 GHz/mm at the open upper and lower channels, respectively. The experimental results agree with those of theoretical simulations performed using the finite-difference time-domain (FDTD) method.

7.
Opt Express ; 22(23): 28977-83, 2014 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-25402136

RESUMEN

We demonstrate real-time continuous-wave terahertz (THz) line-scanned imaging based on a 1 × 240 InGaAs Schottky barrier diode (SBD) array detector with a scan velocity of 25 cm/s, a scan line length of 12 cm, and a pixel size of 0.5 × 0.5 mm². Foreign substances, such as a paper clip with a spatial resolution of approximately 1 mm that is hidden under a cracker, are clearly detected by this THz line-scanning system. The system consists of the SBD array detector, a 200-GHz gyrotron source, a conveyor system, and several optical components such as a high-density polyethylene cylindrical lens, metal cylindrical mirror, and THz wire-grid polarizer. Using the THz polarizer, the signal-to-noise ratio of the SBD array detector improves because the quality of the source beam is enhanced.


Asunto(s)
Arsenicales/química , Sistemas de Computación , Electrónica/instrumentación , Galio/química , Indio/química , Fenómenos Ópticos , Radiación Terahertz
8.
Opt Express ; 20(28): 29605-12, 2012 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-23388787

RESUMEN

A single groove in a parallel-plate waveguide (PPWG) has been applied to a tunable terahertz (THz) notch filter with a transverse-electromagnetic (TEM) mode. When the air gap between the metal plates of the PPWG is controlled from 60 to 240 µm using a motor controlled translation stage or a piezo-actuator, the resonant frequency of the notch filter is changed from 1.75 up to 0.62 THz, respectively. Therefore, the measured tunable sensitivity of the notch filter increases to 6.28 GHz/µm. The measured resonant frequencies were found to be in good agreement with the calculation using an effective groove depth. Using a finite-difference time-domain (FDTD) simulation, we also demonstrate that the sensitivity of a THz microfluidic sensor can be increased via a small air gap, a narrow groove width, and a deep groove depth.

9.
Opt Express ; 20(6): 6116-23, 2012 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-22418491

RESUMEN

We report experimental and finite-difference time-domain simulation studies on terahertz (THz) characteristics of band gaps by using metal grooves which are located inside the flare parallel-plate waveguide. The vertically localized standing-wave cavity mode (SWCM) between the upper waveguide surface and groove bottom, and the horizontally localized SWCM between two groove side walls (groove cavity) are observed. The E field intensity of the horizontally localized SWCM in grooves is very strongly enchanced which is three order higher than that of the input THz. The 4 band gaps except the Bragg band gap are caused by the π radian delay (out of phase) between the reflected THz field by grooves and the propagated THz field through the air gap. The measurement and simulation results agree well.


Asunto(s)
Metales/química , Refractometría/instrumentación , Resonancia por Plasmón de Superficie/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Radiación Terahertz
10.
Opt Express ; 19(16): 14852-9, 2011 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-21934846

RESUMEN

We present a tunable notch filter having a wide terahertz (THz) frequency range and a low-pass filter (LPF) having a 0.78 THz cutoff frequency. Single slit and multiple slits are positioned at the center of air gaps in tapered parallel-plate waveguides (TPPWG) to obtain the notch filter and LPF, respectively. The notch filter has a dispersion-free and low-loss transverse magnetic (TM) mode. The Q factor was proved to be 138, and the resonant frequency is easily tunable by adjusting the air gaps between TPPWG. On the other hand, the cut off frequency of the LPF was determined using a Bragg stop band, which depends on slit period. The LPF has a transition width of 68 GHz at the cutoff frequency and a dynamic range of 35 dB at stop bands. In addition, the characteristics of such filters were analyzed using finite-difference time-domain (FDTD) simulations.


Asunto(s)
Técnicas Biosensibles , Metales/química , Espectroscopía de Terahertz/métodos , Aire , Simulación por Computador , Diseño de Equipo , Filtración , Gases , Magnetismo , Refractometría , Factores de Tiempo
11.
J Phys Chem A ; 115(1): 35-8, 2011 Jan 13.
Artículo en Inglés | MEDLINE | ID: mdl-21142130

RESUMEN

The structural transition from hydroquinone clathrates to crystalline α-form hydroquinone was observed up to the range of 3 THz frequency as a function of temperatures. We found that all three hydroquinone clathrates, CO(2)-, CH(4)-, and CO(2)/CH(4)-loaded hydroquinone clathrates, transform into the α-form hydroquinone at around 102 ± 7 °C. The resonance peak of the CO(2)-loaded hydroquinone clathrate at 2.15 THz decreases with increasing temperature, indicating that CO(2) guest molecules are readily released from the host framework prior to the structural transformation. This reveals that the hydroquinone clathrates may transform into the stable α-form hydroquinone via the metastable form of guest-free clathrate, which depends on guest molecules enclathrated in the cages of the host frameworks. A strong resonance of the α-form hydroquinone at 1.18 THz gradually shifts to the low frequency with increasing temperature and shifts back to the high frequency with decreasing temperature.


Asunto(s)
Hidroquinonas/química , Análisis Espectral , Temperatura , Factores de Tiempo
12.
Opt Express ; 18(2): 1289-95, 2010 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-20173954

RESUMEN

This paper reports an experimental and simulation study of a tapered parallel-plate waveguide (TPPWG) to improve THz coupling to the plate separation gap. The flat- and round-type TPPWG without any silicon lens is compared to the parallel-plate waveguide (PPWG) with a plano-cylindrical silicon lens. The spectrum amplitudes of the input-side TPPWG and the input- and output-side TPPWG both having a 3 degrees slop angle increased about 56% and 103% at 1 THz when compared to that of the PPWG. Since the input- and output-side TPPWG had almost no impedance mismatch to the propagating THz wave, coupling to the waveguide could be improved twice compared with the PPWG.


Asunto(s)
Modelos Teóricos , Dispositivos Ópticos , Refractometría/instrumentación , Transductores , Simulación por Computador , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Radiación Terahertz
13.
Opt Express ; 17(19): 17082-7, 2009 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-19770926

RESUMEN

In this study, we have designed, fabricated, and characterized a miniaturized optical fiber-coupled terahertz (THz) endoscope system. The endoscopic system utilized a photoconductive generator and detector driven by a mode-locked Ti:sapphire laser. In reflection mode, the endoscope showed a high signal-to-noise ratio and a wide frequency spectrum similar to the conventional THz time-domain spectroscopic system. The cross section of the endoscope including generator and detector head is (2 x 4 mm) x 6 mm, which is small enough to be inserted into a human body. For a feasibility test, the endoscopic system was used to measure reflective THz signals from the side wall of the mouth, tongue, and palm skin as well as from water for comparison. The absorption and refractive index of the side wall of the mouth and tongue were similar to those of water but those of the palm skin were less than water.


Asunto(s)
Endoscopios , Fibras Ópticas , Espectroscopía de Terahertz/métodos , Humanos , Especificidad de Órganos , Refractometría
14.
Opt Express ; 17(11): 9212-8, 2009 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-19466171

RESUMEN

We present experimental and theoretical studies on terahertz surface plasmon (TSP) propagation on slit and rectangular aperture arrays in an aluminum sheet. Terahertz waves are coupled onto the plasmonic structures via a parallel plate waveguide. Long-lasting oscillations are observed in the temporal pulse shape after propagating through the periodic structure, whose Fourier transformation into the frequency domain results in Bragg-resonance spectral features. We show that the interference between the incident wave and the radiation reflected from both the aperture array and the waveguide block is responsible for this Bragg-resonance behavior. The reflection coefficient for a single slit is deduced to be 0.017 +/- 0.002.


Asunto(s)
Refractometría/instrumentación , Resonancia por Plasmón de Superficie/instrumentación , Diseño Asistido por Computadora , Diseño de Equipo , Análisis de Falla de Equipo , Luz , Reproducibilidad de los Resultados , Dispersión de Radiación , Sensibilidad y Especificidad , Radiación Terahertz
15.
Opt Express ; 16(1): 271-8, 2008 Jan 07.
Artículo en Inglés | MEDLINE | ID: mdl-18521158

RESUMEN

In this study, the coupling properties of a conical copper wire waveguide were investigated in the terahertz (THz) frequency range using theoretical simulations and experiments. Because a conical wire tip has a smaller tip diameter than a cylindrical wire tip, it has a greater THz field density than a cylindrical wire tip. The measured THz pulse increased 4.5 times upon contact with the 30 microm-diameter conical wire tip compared with the THz pulse when a 500 microm-diameter cylindrical wire tip was used. This result agrees well with that of theoretical simulations such as high-frequency structure simulation (HFSS), which is based on the finite element method.


Asunto(s)
Rayos Infrarrojos , Microondas , Radiometría/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Dosis de Radiación , Radiometría/métodos
16.
Sci Rep ; 5: 13817, 2015 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-26347288

RESUMEN

Photoconductive antennas with nano-structured electrodes and which show significantly improved performances have been proposed to satisfy the demand for compact and efficient terahertz (THz) sources. Plasmonic field enhancement was previously considered the dominant mechanism accounting for the improvements in the underlying physics. However, we discovered that the role of plasmonic field enhancement is limited and near-field distribution of bias field should be considered as well. In this paper, we clearly show that the locally enhanced bias field due to the size effect is much more important than the plasmonic enhanced absorption in the nano-structured electrodes for the THz emitters. Consequently, an improved nano-electrode design is presented by tailoring bias field distribution and plasmonic enhancement. Our findings will pave the way for new perspectives in the design and analysis of plasmonic nano-structures for more efficient THz photonic devices.