Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 191
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Diabet Med ; 41(3): e15195, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37562414

RESUMEN

AIMS: To examine the psychometric properties of the Diabetes Management Experiences Questionnaire (DME-Q). Adapted from the validated Glucose Monitoring Experiences Questionnaire, the DME-Q captures satisfaction with diabetes management irrespective of treatment modalities. METHODS: The DME-Q was completed by adults with type 1 diabetes as part of a randomized controlled trial comparing hybrid closed loop (HCL) to standard therapy. Most psychometric properties were examined with pre-randomization data (n = 149); responsiveness was examined using baseline and 26-week follow-up data (n = 120). RESULTS: Pre-randomization, participants' mean age was 44 ± 12 years, 52% were women. HbA1c was 61 ± 11 mmol/mol (7.8 ± 1.0%), diabetes duration was 24 ± 12 years and 47% used an insulin pump prior to the trial. A forced three-factor analysis revealed three expected domains, that is, 'Convenience', 'Effectiveness' and 'Intrusiveness', and a forced one-factor solution was also satisfactory. Internal consistency reliability was strong for the three subscales ( α range = 0.74-0.84) and 'Total satisfaction' ( α = 0.85). Convergent validity was demonstrated with moderate correlations between DME-Q 'Total satisfaction' and diabetes distress (PAID: rs = -0.57) and treatment satisfaction (DTSQ; rs = 0.58). Divergent validity was demonstrated with a weak correlation with prospective/retrospective memory (PRMQ: rs = -0.16 and - 0.13 respectively). Responsiveness was demonstrated, as participants randomized to HCL had higher 'Effectiveness' and 'Total satisfaction' scores than those randomized to standard therapy. CONCLUSIONS: The 22-item DME-Q is a brief, acceptable, reliable measure with satisfactory structural and construct validity, which is responsive to intervention. The DME-Q is likely to be useful for evaluation of new pharmaceutical agents and technologies in research and clinical settings.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adulto , Humanos , Femenino , Persona de Mediana Edad , Masculino , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Automonitorización de la Glucosa Sanguínea , Satisfacción del Paciente , Psicometría , Reproducibilidad de los Resultados , Estudios Retrospectivos , Estudios Prospectivos , Glucemia , Encuestas y Cuestionarios
2.
Sensors (Basel) ; 24(3)2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38339505

RESUMEN

This paper describes an automated method and device to conduct the Chair Stand Tests of the Fullerton Functional Test Battery. The Fullerton Functional Test is a suite of physical tests designed to assess the physical fitness of older adults. The Chair Stand Tests, which include the Five Times Sit-to-Stand Test (5xSST) and the 30 Second Sit-to-Stand Test (30CST), are the standard for measuring lower-body strength in older adults. However, these tests are performed manually, which can be labor-intensive and prone to error. We developed a sensor-integrated chair that automatically captures the dynamic weight and distribution on the chair. The collected time series weight-sensor data is automatically uploaded for immediate determination of the sit-to-stand timing and counts, as well as providing a record for future comparison of lower-body strength progression. The automatic test administration can provide significant labor savings for medical personnel and deliver much more accurate data. Data from 10 patients showed good agreement between the manually collected and sensor-collected 30CST data (M = 0.5, SD = 1.58, 95% CI = 1.13). Additional data processing will be able to yield measurements of fatigue and balance and evaluate the mechanisms of failed standing attempts.


Asunto(s)
Aptitud Física , Humanos , Anciano
3.
Diabet Med ; 40(4): e15020, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36468784

RESUMEN

AIM: To explore the lived experience of older adults with type 1 diabetes using closed-loop automated insulin delivery, an area previously receiving minimal attention. METHODS: Semi-structured interviews were conducted with adults aged 60 years or older with long-duration type 1 diabetes who participated in a randomised, open-label, two-stage crossover trial comparing first-generation closed-loop therapy (MiniMed 670G) versus sensor-augmented pump therapy. Interview recordings were transcribed, thematically analysed and assessed. RESULTS: Twenty-one older adults participated in interviews after using closed-loop therapy. Twenty were functionally independent, without frailty or major cognitive impairment; one was dependent on caregiver assistance, including for diabetes management. Quality of life benefits were identified, including improved sleep and reduced diabetes-related psychological burden, in the context of experiencing improved glucose levels. Gaps between expectations and reality of closed-loop therapy were also experienced, encountering disappointment amongst some participants. The cost was perceived as a barrier to continued closed-loop access post-trial. Usability issues were identified, such as disruptive overnight alarms and sensor inaccuracy. CONCLUSIONS: The lived experience of older adults without frailty or major cognitive impairment using first-generation closed-loop therapy was mainly positive and concordant with glycaemic benefits found in the trial. Older adults' lived experience using automated insulin delivery beyond trial environments requires exploration; moreover, the usability needs of older adults should be considered during future device development.


Asunto(s)
Diabetes Mellitus Tipo 1 , Fragilidad , Humanos , Anciano , Insulina/uso terapéutico , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Hipoglucemiantes/uso terapéutico , Calidad de Vida , Resultado del Tratamiento , Sistemas de Infusión de Insulina , Automonitorización de la Glucosa Sanguínea , Estudios Cruzados , Glucemia
4.
J Sleep Res ; : e14106, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-38050705

RESUMEN

Hypoglycaemia during sleep is a common and clinically important issue for people living with insulin-treated diabetes. Continuous glucose monitoring devices can help to identify nocturnal hypoglycaemia and inform treatment strategies. However, sleep is generally inferred, with diabetes researchers and physicians using a fixed-overnight period as a proxy for sleep-wake status when analysing and interpretating continuous glucose monitoring data. No study to date has validated such an approach with established sleep measures. Continuous glucose monitoring and research-grade actigraphy devices were worn and sleep diaries completed for 2 weeks by 28 older adults (mean age 67 years [SD 5]; 17 (59%) women) with type 1 diabetes. Using continuous glucose monitoring data from a total of 356 nights, fixed-overnight (using the recommended period of 00:00 hours-06:00 hours) and objectively-measured sleep periods were compared. The fixed-overnight period approach missed a median 57 min per night (interquartile range: 49-64) of sleep for each participant, including five continuous glucose monitoring-detected hypoglycaemia episodes during objectively-measured sleep. Twenty-seven participants (96%) had at least 1 night with continuous glucose monitoring time-in-range and time-above-range discrepancies both ≥ 10 percentage points, a clinically significant discrepancy. The utility of fixed-overnight time continuous glucose monitoring as a proxy for sleep-awake continuous glucose monitoring is inadequate as it consistently excludes actual sleep time, obscures glycaemic patterns, and misses sensor hypoglycaemia episodes during sleep. The use of validated measures of sleep to aid interpretation of continuous glucose monitoring data is encouraged.

5.
Environ Sci Technol ; 57(48): 19223-19235, 2023 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-37933439

RESUMEN

Insights into how biological systems respond to high- and low-dose acute environmental stressors are a fundamental aspect of exposome research. However, studying the impact of low-level environmental exposure in conventional in vitro settings is challenging. This study employed a three-dimensional (3D) biomimetic microfluidic lung-on-chip (µLOC) platform and RNA-sequencing to examine the effects of two model anthropogenic engineered nanoparticles (NPs): zinc oxide nanoparticles (Nano-ZnO) and copier center nanoparticles (Nano-CCP). The airway epithelium exposed to these NPs exhibited dose-dependent increases in cytotoxicity and barrier dysregulation (dominance of the external exposome). Interestingly, even nontoxic and low-level exposure (10 µg/mL) of the epithelium compartment to Nano-ZnO triggered chemotaxis of lung fibroblasts toward the epithelium. An increase in α smooth muscle actin (α-SMA) expression and contractile activity was also observed in these cells, indicating a bystander-like adaptive response (dominance of internal exposome). Further bioinformatics and network analysis showed that a low-dose Nano-ZnO significantly induced a robust transcriptomic response and upregulated several hub genes associated with the development of lung fibrosis. We propose that Nano-ZnO, even at a no observable effect level (NOEL) dose according to conventional standards, can function as a potent nanostressor to disrupt airway epithelium homeostasis. This leads to a cascade of profibrotic events in a cross-tissue compartment fashion. Our findings offer new insights into the early acute events of respiratory harm associated with environmental NPs exposure, paving the way for better exposomic understanding of this emerging class of anthropogenic nanopollutants.


Asunto(s)
Exposoma , Nanopartículas , Óxido de Zinc , Biomimética , Microfluídica , Nanopartículas/toxicidad , Fibroblastos , Óxido de Zinc/toxicidad
6.
Heart Lung Circ ; 32(11): 1354-1360, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37821262

RESUMEN

BACKGROUND: The coronavirus disease 2019 (COVID-19) pandemic paved the way for telehealth consultations. We aimed to determine the impact of telehealth on rates of failure to attend (FTA) in adult congenital heart disease (ACHD) clinics and whether telehealth could re-engage patients with previous FTA face-to-face appointments. METHODS: This was a retrospective audit of a tertiary ACHD clinic over a 12-month pre-telehealth (26 March 2019-17 March 2020) and 12-month post-telehealth implementation period (24 March 2020-16 March 2021). Patients with one or more FTAs during the 24-month study period were included. Our ACHD clinic is run three times per month. Patients with ACHD are offered lifelong follow-up and reviewed annually on average. Re-engagement was defined as two or more consecutive face-to-face FTAs immediately before the telehealth period with subsequent attendance of their telehealth appointment. RESULTS: A total of 359 patients with a total of 623 FTAs were included. Complexity of congenital heart disease was moderate in 56% (202/359) and severe in 19% (69/359) of patients. Overall FTA rate was 18% (623/3,452). FTA rate was significantly lower in the post-telehealth period (15%, 257/1,664) compared with the pre-telehealth period (20%, 366/1,788) (p<0.00001). At study conclusion, 1% of patients had died (5/359). Of the 354 remaining patients, 42% (150/354) were considered lost to follow-up (two or more FTAs including telehealth), 37% (132/354) missed only one clinic appointment, and 20% (72/354) previously considered lost to follow-up had re-engaged in the telehealth period. CONCLUSIONS: Rates of FTA in a tertiary ACHD clinic significantly reduced after the introduction of telehealth consultation. A fifth of patients considered lost to follow-up were re-engaged with telehealth. Additional strategies to further reduce FTA should be explored.


Asunto(s)
COVID-19 , Cardiopatías Congénitas , Telemedicina , Humanos , Adulto , Estudios Retrospectivos , Cardiopatías Congénitas/epidemiología , Cardiopatías Congénitas/terapia , Instituciones de Atención Ambulatoria , COVID-19/epidemiología , COVID-19/terapia
7.
Intern Med J ; 52(8): 1434-1436, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35973960

RESUMEN

We have analysed insulin antibodies in 149 adults with type 1 diabetes and 2859 people without diabetes. We have determined that insulin antibody levels are higher in adults with, versus without, diabetes and that the levels are falling, and more patients are becoming antibody-negative post islet cell transplantation.


Asunto(s)
Diabetes Mellitus Tipo 1 , Trasplante de Islotes Pancreáticos , Adulto , Australia/epidemiología , Diabetes Mellitus Tipo 1/epidemiología , Diabetes Mellitus Tipo 1/cirugía , Humanos , Terapia de Inmunosupresión , Insulina , Anticuerpos Insulínicos
8.
Heart Lung Circ ; 31(6): 867-872, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35063381

RESUMEN

BACKGROUND: Little is known about the impact of a coarctation repair on the functional outcomes of young adults. This study aimed to determine (1) the functional and mental health status in young adults with previous coarctation repair, and (2) the impact of late hypertension on their quality of life. METHODS: A cross-sectional study using validated self-reported questionnaires (Short Form 36 version 2 [SF-36v2], Beck Depression Inventory [BDI], and State-Trait Anxiety Inventory [STAI]) was performed in 54 patients aged 15-47 years with previous paediatric coarctation repair. Questionnaire scores were compared to healthy age- and gender-matched controls. Patients' previously published 24-hour blood pressure monitoring results were included. RESULTS: Late hypertension was present in 64% (34/54) at a mean of 29±8 years after coarctation repair. SF-36v2 mean physical component summary score was significantly lower in coarctation patients compared with controls (53.1±6.8 vs 56.0±4.7, p=0.02), but there was no significant difference in mean mental component summary score (p=0.2). SF-36v2 mean role emotional score tended to be associated with 10 mmHg increases in mean 24-hour systolic blood pressure (regression coefficient 4.3 p=0.06). STAI mean trait anxiety score tended to be higher in coarctation patients compared with controls (36.6±9.0 vs 33.5±7.8, p=0.06). There was no significant difference in BDI scores between patients and controls. CONCLUSIONS: Young adults with previous coarctation repair report poorer physical health and tended towards higher anxiety trait compared to healthy controls. Strategies to improve self-reported physical health and anxiety should be explored. Long-term assessment of quality of life outcomes in coarctation patients is warranted.


Asunto(s)
Coartación Aórtica , Hipertensión , Ansiedad/epidemiología , Ansiedad/etiología , Niño , Estudios Transversales , Humanos , Calidad de Vida/psicología , Autoinforme , Adulto Joven
9.
Heart Lung Circ ; 30(3): 446-453, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32665171

RESUMEN

BACKGROUND: Berlin Heart EXCOR Pediatric Ventricular Assist Device (BHE) (Berlin Heart AG, Berlin, Germany, BHE) is used worldwide for mechanical circulatory support as a bridge to transplantation or recovery for children with end-stage heart failure. The study aim was to evaluate morbidity and mortality of children less than one year old supported with BHE to identify predictors of adverse outcomes. METHODS: Data of all children aged less than one year supported with BHE between 2005 and 2018 at the Royal Children's Hospital, Melbourne were reviewed. Adverse events were defined using PediMACS criteria. RESULTS: Fourteen (14) children under 1 year of age were implanted with BHE at a median age and weight of 0.37 years (IQR 0.09-0.7) and 5.7 kg (IQR 3.5-7.95) respectively. Four (4) patients were neonates, and 10 were older infants. Twelve (12) patients had cardiomyopathy and two, myocarditis. Preoperative extracorporeal membrane oxygenation (ECMO) support was required in six patients for a mean of 9 days (IQR 6-13). Sepsis occurred in five patients (36%) and thromboembolic stroke in two patients (14%). Survival to bridge to transplantation (11) and recovery (1) was achieved in 12 patients (86%). Mortality was 14%. The median duration of BHE support was 110 days (IQR 40-161). Both patients who died were neonates with myocarditis and required surgical re-intervention during BHE support. CONCLUSIONS: BHE provides excellent support as a bridge to transplantation or recovery in infants, with a low incidence of neurological dysfunction. Neonates with myocarditis may be at greater risk for death after BHE implantation.


Asunto(s)
Oxigenación por Membrana Extracorpórea/métodos , Insuficiencia Cardíaca/terapia , Trasplante de Corazón , Corazón Auxiliar , Femenino , Estudios de Seguimiento , Alemania , Humanos , Lactante , Recién Nacido , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
10.
Am J Physiol Gastrointest Liver Physiol ; 319(4): G454-G461, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32755311

RESUMEN

High-resolution esophageal manometry (HRM) in its current form assesses only the contraction phase of peristalsis. Degree of esophageal distension ahead of contraction is a surrogate of relaxation and can be measured from intraluminal esophageal impedance measurements. The characteristics of esophageal contractions, i.e., their amplitude, duration, velocity, and modulating factors, have been well studied. We studied the effect of bolus volume and viscosity and posture on swallow-induced distension and contraction and the temporal relationship between the two. HRM impedance recordings of 50 healthy subjects with no esophageal symptoms were analyzed. Eight to ten swallows of 5 and 10 mL of 0.5 N saline and a viscous bolus were recorded in the supine and Trendelenburg positions. Custom-built computer software generated the distension-contraction plots and numerical data of the amplitudes of distension (cross-sectional area) and contraction, and the temporal relationship between distension and peak contraction. The hallmarks of distension waveforms are that 1) distension peak, similarly to contraction, travels the esophagus in a peristaltic fashion, and the amplitude of distension increases from the proximal-to-distal direction; 2) the amplitude of distension is greater with 10 mL than with 5 mL and greater in Trendelenburg than in supine posture; and 3) bolus viscosity increases the amplitude of distension and alters the temporal relationship between distension and contraction waveforms. We describe the characteristics of esophageal distension during peristalsis and the relationship between distension and contraction in a relatively large cohort of normal subjects. These data can be used to compare differences between normal subjects and patients with various esophageal motility disorders in future studies.NEW & NOTEWORTHY We studied esophageal distension (surrogate of inhibition) ahead of contraction during peristalsis from intraluminal esophageal impedance measurements. Esophageal distension, similarly to contraction, travels the esophagus in a sequential manner, and the amplitude of esophageal distension increases from proximal to distal direction in the esophagus. Bolus volume, viscosity and posture have significant effects on the amplitude of distension and its temporal relationship with contraction.


Asunto(s)
Esófago/fisiología , Peristaltismo/fisiología , Postura/fisiología , Adulto , Anciano , Fenómenos Biomecánicos , Deglución/fisiología , Impedancia Eléctrica , Trastornos de la Motilidad Esofágica , Femenino , Inclinación de Cabeza , Voluntarios Sanos , Humanos , Masculino , Manometría , Persona de Mediana Edad , Contracción Muscular/fisiología , Posición Supina , Viscosidad
11.
Am J Hum Genet ; 100(5): 751-765, 2017 May 04.
Artículo en Inglés | MEDLINE | ID: mdl-28475858

RESUMEN

We developed a variant-annotation method that combines sequence-based machine-learning classification with a context-dependent algorithm for selecting splice variants. Our approach is distinctive in that it compares the splice potential of a sequence bearing a variant with the splice potential of the reference sequence. After training, classification accurately identified 168 of 180 (93.3%) canonical splice sites of five genes. The combined method, CryptSplice, identified and correctly predicted the effect of 18 of 21 (86%) known splice-altering variants in CFTR, a well-studied gene whose loss-of-function variants cause cystic fibrosis (CF). Among 1,423 unannotated CFTR disease-associated variants, the method identified 32 potential exonic cryptic splice variants, two of which were experimentally evaluated and confirmed. After complete CFTR sequencing, the method found three cryptic intronic splice variants (one known and two experimentally verified) that completed the molecular diagnosis of CF in 6 of 14 individuals. CryptSplice interrogation of sequence data from six individuals with X-linked dyskeratosis congenita caused by an unknown disease-causing variant in DKC1 identified two splice-altering variants that were experimentally verified. To assess the extent to which disease-associated variants might activate cryptic splicing, we selected 458 pathogenic variants and 348 variants of uncertain significance (VUSs) classified as high confidence from ClinVar. Splice-site activation was predicted for 129 (28%) of the pathogenic variants and 75 (22%) of the VUSs. Our findings suggest that cryptic splice-site activation is more common than previously thought and should be routinely considered for all variants within the transcribed regions of genes.


Asunto(s)
Proteínas de Ciclo Celular/genética , Biología Computacional , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Variación Genética , Proteínas Nucleares/genética , Sitios de Empalme de ARN , Algoritmos , Proteínas de Ciclo Celular/metabolismo , Fibrosis Quística/genética , Regulador de Conductancia de Transmembrana de Fibrosis Quística/metabolismo , Disqueratosis Congénita/genética , Exones , Regulación de la Expresión Génica , Sitios Genéticos , Genómica , Células HEK293 , Humanos , Intrones , Mutación Missense , Proteínas Nucleares/metabolismo , Empalme del ARN , Análisis de Secuencia de ADN , Máquina de Vectores de Soporte
12.
Global Health ; 16(1): 40, 2020 05 05.
Artículo en Inglés | MEDLINE | ID: mdl-32370784

RESUMEN

BACKGROUND: Achieving maternal health outcomes in the SDGs requires the implementation of more targeted policies and strategies. While the MDGs may have deepened our understanding in this regard, we know little about the trends in maternal health services utilisation among primigravidas, and how age and geographical regions could have influenced these trends. In this study, we examined utilisation of antenatal and skilled delivery services among primigravidas in Uganda, a country with one of the highest maternal mortality ratios, and where early childbearing and its attendant challenges are common. METHODS: Guided by Andersen's Behavioural Model, we fitted multivariate regression models to a pooled dataset of the 2006, 2011 and 2016 Ugandan Demographic and Health Survey (n = 3477) to understand the dynamics in Antenatal Care (ANC) and Skilled Birth Attendance (SBAs) utilisation among primigravidas. Post-estimation margins were employed to further highlight the effect of age and geographical regions. RESULTS: The analyses show an improvement in access to maternal health services among primigravidas from 2006 to 2016. Compared to 2006, primigravidas in 2016 were 48%, 24% and 2.98 times more likely to have early ANC, four or more ANC visits, and SBAs, respectively. Altogether, a primigravida in 2016 relative to 2006 was 42% more likely to meet all three maternal health service indicators. Post-estimation margins analyses on age and geographical disparities revealed that younger primigravidas have lower probability, while primigravidas in Eastern Region, one of the most deprived in the country, have the lowest probability of accessing maternal health services. Also, the study found education, wealth, women's household decision-making power, place of residence as important determinants of ANC visits and SBAs. CONCLUSIONS: Based on our findings, it is important to address the vulnerabilities of primigravidas, particularly younger individuals, in accessing early ANC. Uganda should scale-up decentralisation and integration of maternal health delivery in local communities as a strategy of addressing lingering geographical disparities, and ultimately improve maternal health outcomes in the SDGs period.


Asunto(s)
Servicios de Salud Materna/estadística & datos numéricos , Aceptación de la Atención de Salud/estadística & datos numéricos , Adolescente , Adulto , Parto Obstétrico , Escolaridad , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Mortalidad Materna , Persona de Mediana Edad , Embarazo , Factores Socioeconómicos , Uganda , Adulto Joven
13.
Am J Physiol Gastrointest Liver Physiol ; 316(4): G519-G526, 2019 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-30676774

RESUMEN

Each swallow induces a wave of inhibition followed by contraction in the esophagus. Unlike contraction, which can easily be measured in humans using high-resolution manometry (HRM), inhibition is difficult to measure. Luminal distension is a surrogate of the esophageal inhibition. The aim of this study was to determine the effect of posture on the temporal and quantitative relationship between distension and contraction along the entire length of the esophagus in normal healthy subjects by using concurrent HRM, HRM impedance (HRMZ), and intraluminal ultrasound (US). Studies were conducted in 15 normal healthy subjects in the supine and Trendelenburg positions. Both manual and automated methods were used to extract quantitative pressure and impedance-derived features from the HRMZ recordings. Topographical plots of distension and contraction were visualized along the entire length of the esophagus. Distension was also measured from the US images during 10-ml swallows at 5 cm above the lower esophageal sphincter. Each swallow was associated with luminal distension followed by contraction, both of which traversed the esophagus in a sequential/peristaltic fashion. Luminal distension (US) and esophageal contraction amplitude were greater in the Trendelenburg compared with the supine position. Length of esophageal breaks (in the transition zone) were reduced in the Trendelenburg position. Change in posture altered the temporal relationship between distension and contraction, and bolus traveled closer to the esophageal contraction in the Trendelenburg position. Topographical contraction-distension plots derived from HRMZ recordings is a novel way to visualize esophageal peristalsis. Future studies should investigate if abnormalities of esophageal distension are the cause of functional dysphagia. NEW & NOTEWORTHY Ascending contraction and descending inhibition are two important components of peristalsis. High-resolution manometry only measures the contraction phase of peristalsis. We measured esophageal distension from intraluminal impedance recordings and developed novel contraction-distension topographical plots to prove that similar to contraction, distension also travels in a peristaltic fashion. Change in posture from the supine to the Trendelenburg position also increased the amplitude of esophageal distension and contraction and altered the temporal relationship between distension and contraction.


Asunto(s)
Deglución/fisiología , Esófago/fisiología , Manometría/métodos , Peristaltismo/fisiología , Postura/fisiología , Adulto , Fenómenos Fisiológicos del Sistema Digestivo , Impedancia Eléctrica , Femenino , Humanos , Masculino , Contracción Muscular/fisiología , Posicionamiento del Paciente/métodos
14.
Langmuir ; 35(23): 7487-7495, 2019 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-30480453

RESUMEN

Tumor stromal residing cancer-associated fibroblasts (CAFs) are significant accomplices in the growth and development of malignant neoplasms. As cancer progresses, the stroma undergoes a dramatic remodeling and stiffening of its extracellular matrix (ECM). However, exactly how these biomechanical changes influence the CAF behavior and the functional paracrine crosstalk with the neighboring tumor cells in a 3-dimensional (3D) microenvironment remains elusive. Herein, a collagen and alginate interpenetrating network (CoAl-IPN) hydrogel system was employed as a 3D in vitro surrogate of the cancerous breast tissue stromal niche. In this study, the mechanical properties of CoAl-IPN were precisely fine-tuned with Young's modulus ( E) values of ∼108 and 898 Pa. The results revealed that the 3D polymeric network mechanics and microstructure are critical biophysical determinants of the human breast CAF (b-CAF) morphology, phenotype, and paracrine dialogue with MDA-MB-231 tumoroids. A compliant hydrogel network favors b-CAF spreading, nuclear translocation of the YAP/TAZ mechanosignaling protein, and upregulation of CAF hallmark transcripts. Conversely, a rigid and highly cross-linked hydrogel network imposed a physical entrapment effect on the b-CAFs that limited their spreading and phenotype in a manner that effectively muted their pro-tumorigenic paracrine activity. Collectively, the CoAl-IPN 3D culture system has proven to be a versatile platform in defining the 3D biophysical parameters that could either promote or restrain the protumorigenic activity of b-CAFs and sheds critical mechano-mediated light onto the phenotypic plasticity and corresponding specific bioactivity of b-CAFs in the 3D microenvironment.


Asunto(s)
Fibroblastos/citología , Fibroblastos/efectos de los fármacos , Hidrogeles/química , Hidrogeles/farmacología , Fenómenos Mecánicos/efectos de los fármacos , Fenotipo , Alginatos/química , Fenómenos Biomecánicos/efectos de los fármacos , Proteínas de Ciclo Celular/metabolismo , Línea Celular Tumoral , Matriz Extracelular/efectos de los fármacos , Matriz Extracelular/metabolismo , Fibroblastos/metabolismo , Humanos , Factores de Transcripción/metabolismo
15.
Cardiol Young ; 29(7): 939-944, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31204634

RESUMEN

BACKGROUND: Paediatric heart transplantation in Australia is centralised at The Royal Children's Hospital, Melbourne. Survival to adulthood is improving but the ongoing need for complex medical therapy, surveillance, and potential for late complications continues to impact on quality of life. Quality of life in adults who underwent heart transplantation in childhood in Australia has not been assessed. METHODS: Cross-sectional quality of life data were collected from paediatric heart transplant survivors >18 years of age using Rand 36-Item Health Survey. Self-reported raw scores were transformed to a 0-100 scale with higher scores indicating better quality of life. Mean scores were compared to National Health Survey Short Form-36 Population Norms data using the independent sample t-test. RESULTS: A total of 64 patients (64/151) who underwent transplantation at The Royal Children's Hospital between 1988 and 2016 survived to adulthood. In total 51 patients (51/64, 80%) were alive at the time of the study and 27 (53%) responded with a mean age of 25 ± 6 years, being a median of 11 years (interquartile range 7-19) post-transplantation. Most self-reported quality of life subscale scores were not significantly different from the Australian normative population data. However, self-reported 'General Health' was significantly worse than normative data (p = 0.02). Overall, 93% (25/27) reported their general health as being the same or better compared to 1-year ago. CONCLUSION: Adult survivors after paediatric heart transplantation in Australia report good quality of life in multiple domains and demonstrate independence in activities of daily living and employment. However, lifelong medical treatment may affect perceptions of general health.


Asunto(s)
Trasplante de Corazón , Calidad de Vida , Sobrevivientes/psicología , Actividades Cotidianas , Adolescente , Adulto , Australia , Niño , Estudios Transversales , Empleo , Femenino , Encuestas Epidemiológicas , Humanos , Masculino , Autoinforme , Adulto Joven
16.
Heart Lung Circ ; 28(5): 792-799, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-29691159

RESUMEN

BACKGROUND: Exercise-testing may be a more tolerable method of detecting hypertension in children after coarctation repair compared to gold-standard 24-hour ambulatory blood pressure (BP) monitoring (ABPM). This study aims to determine the prevalence of exercise-induced hypertension and end-organ damage in children after coarctation repair, and the effectiveness of exercise-testing compared to 24-hour ABPM in this population. METHODS: Exercise-testing (Bruce protocol), transthoracic echocardiogram, 24-hour ABPM, and pulse wave velocity were performed in 41 patients aged 8 to 18 years with previous coarctation repair. Median age at repair was 13 days. Exercise-testing data were compared to healthy paediatric controls. Hypertension was defined as BP >95th percentile on 24-hour ABPM compared to normalised data, and systolic BP (SBP) arbitrarily >200mmHg on exercise-testing. RESULTS: After 13±3years, 39% (14/36) were hypertensive on 24-hour ABPM and 12% (5/41) on exercise-testing. Coarctation patients had a higher peak exercise SBP and reduced endurance compared to controls (164±26mmHg vs. 148±19mmHg, p=0.003; and 13.0±1.7mins vs. 14.2±2.4mins, p=0.007; respectively). All patients with a peak exercise SBP >190mmHg were hypertensive on 24-hour ABPM. Pulse wave velocity was higher in hypertensive patients on exercise-testing and 24-hour ABPM compared to normotensive patients (p=0.004 and p=0.06; respectively). CONCLUSIONS: Exercise-testing may be a useful tool to detect hypertension in children and young adults after coarctation repair, particularly in those who do not tolerate 24-hour ABPM. Normative peak exercise BP data for age should be obtained to improve the accuracy of exercise-testing in detecting hypertension.


Asunto(s)
Coartación Aórtica/cirugía , Presión Sanguínea/fisiología , Prueba de Esfuerzo/efectos adversos , Ejercicio Físico/fisiología , Hipertensión/epidemiología , Adolescente , Coartación Aórtica/fisiopatología , Monitoreo Ambulatorio de la Presión Arterial , Niño , Estudios Transversales , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/etiología , Hipertensión/fisiopatología , Masculino , Periodo Posoperatorio , Prevalencia , Análisis de la Onda del Pulso , Estudios Retrospectivos , Factores de Tiempo , Victoria/epidemiología
17.
Heart Lung Circ ; 28(7): 1082-1089, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30931916

RESUMEN

BACKGROUND: Twenty-four-hour (24-hr) ambulatory blood pressure monitoring (ABPM) is often considered the gold standard to detect hypertension. We aimed to determine the short-term progression of 24-hour blood pressure after coarctation repair and to compare ABPM between two different devices. METHODS: We performed a cross-sectional study using 24-hour ABPM (Oscar 2) in 47 patients aged 16-48 years with previous paediatric coarctation repair and not on antihypertensive medication. Results were compared to a previous ABPM using paired analyses. A subset (10/47, 21%) had an additional previous ABPM performed using a Spacelabs device. RESULTS: After a mean follow-up of 27±6 years after repair, hypertension and prehypertension on Oscar 2 ABPM was present in 57% (27/47) and 11% (5/47), respectively. Mean follow-up time between Oscar 2 ABPMs was 3.9±1.4 years, and between first Oscar 2 and Spacelabs and between Spacelabs and second Oscar 2 ABPM was 1.4±0.8 and 1.8±0.3 years, respectively. There was no difference in the proportion of hypertensive patients between Oscar 2 ABPMs (55% [26/47] vs. 57% [27/47], p=1.0) but 17 patients (17/47, 36%) had a reclassification of 24-hour ABPM status. Mean 24-hour systolic blood pressure was higher in both Oscar 2 ABPMs compared to Spacelabs (142.4±11.7 vs. 120.4±11.8mmHg, p=0.0001; and 137.4±12.2 vs. 120.4±11.8mmHg, p=0.0001; respectively). CONCLUSION: There was high intra-device reproducibility of 24-hour ABPM results using an Oscar 2 device but poor inter-device reproducibility in patients with repaired coarctation. Device-specific reference values may be required to ensure reliable 24-hour ABPM interpretation.


Asunto(s)
Antihipertensivos/administración & dosificación , Coartación Aórtica , Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea/efectos de los fármacos , Hipertensión , Complicaciones Posoperatorias , Procedimientos Quirúrgicos Vasculares/efectos adversos , Adulto , Coartación Aórtica/fisiopatología , Coartación Aórtica/cirugía , Preescolar , Estudios Transversales , Femenino , Estudios de Seguimiento , Humanos , Hipertensión/tratamiento farmacológico , Hipertensión/etnología , Hipertensión/fisiopatología , Lactante , Recién Nacido , Masculino , Complicaciones Posoperatorias/tratamiento farmacológico , Complicaciones Posoperatorias/fisiopatología , Reproducibilidad de los Resultados
18.
Physiol Genomics ; 50(3): 190-196, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29341866

RESUMEN

Endomyocardial biopsy (EMB) remains the gold standard for detecting rejection after heart transplantation but is costly and invasive. This study aims to distinguish no rejection (0R) from low-grade rejection (1R/2R) after heart transplantation in children by using global gene expression profiling in blood. A total of 106 blood samples with corresponding EMB from 18 children who underwent heart transplantation from 2011 to 2014 were analyzed (18 baseline/pretransplantation samples, 88 EMB samples). Corresponding rejection grades for each blood sample were 0R in 39% (34/88), 1R in 51% (45/88), and 2R in 10% (9/88). mRNA from each sample was sequenced. Differential expression analysis was performed at the gene level. A k-nearest neighbor (kNN) analysis was applied to the most differentially expressed (DE) genes to identify rejection after transplantation. Mean age at transplantation was 10.0 ± 5.4 yr. Expression of B cell and T cell receptor sequences was used to measure the effect of posttransplantation immunosuppression. Follow-up samples had lower levels of immunoglobulin gene families compared with pretransplantation ( P < 3E-5) (lower numbers of activated B cells). T cell receptor alpha and beta gene families had decreased expression in 0R samples compared with pretransplantation ( P < 4E-5) but recovered to near baseline levels in 1R/2R samples. kNN using the most DE gene (MKS1) and k = 9 nearest neighbors correctly identified 83% (73/88) of 1R/2R compared with 0R by leave-one-out cross validation. Using a genomic approach we can distinguish low-grade cellular allograft rejection (1R/2R) from no rejection (0R) after heart transplantation in children despite a wide age range.


Asunto(s)
Perfilación de la Expresión Génica , Rechazo de Injerto/genética , Trasplante de Corazón , Adolescente , Niño , Preescolar , Femenino , Regulación de la Expresión Génica , Humanos , Lactante , Masculino
19.
J Am Chem Soc ; 140(16): 5599-5606, 2018 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-29652497

RESUMEN

This article describes the development of a second-generation catalyst system for the transannular C-H functionalization of alicyclic amines. Pyridine- and quinoline-carboxylate ligands are shown to be highly effective for increasing the reaction rate, yield, and scope of Pd-catalyzed transannular C-H arylation reactions of azabicyclo[3.1.0]hexane, azabicyclo[3.1.1]heptane, azabicyclo[3.2.1]octane, and piperidine derivatives. Mechanistic studies reveal that the pyridine/quinoline-carboxylates play a role in impeding both reversible and irreversible catalyst decomposition pathways. These ligands enable the first reported examples of the transannular C-H arylation of the ubiquitous tropane, 7-azanorbornane, and homotropane cores. Finally, the pyridine/quinoline-carboxylates are shown to promote both transannular C-H arylation and transannular C-H dehydrogenation on a homotropane substrate.


Asunto(s)
Alcanos/química , Compuestos de Azabiciclo/química , Paladio/química , Catálisis , Ligandos , Piridinas/química , Quinolinas/química
20.
Hum Mol Genet ; 25(10): 1923-1933, 2016 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-26911677

RESUMEN

Elevated sweat chloride levels, failure to thrive (FTT), and lung disease are characteristic features of cystic fibrosis (CF, OMIM #219700). Here we describe variants in CA12 encoding carbonic anhydrase XII in two pedigrees exhibiting CF-like phenotypes. Exome sequencing of a white American adult diagnosed with CF due to elevated sweat chloride, recurrent hyponatremia, infantile FTT and lung disease identified deleterious variants in each CA12 gene: c.908-1 G>A in a splice acceptor and a novel frameshift insertion c.859_860insACCT. In an unrelated consanguineous Omani family, two children with elevated sweat chloride, infantile FTT, and recurrent hyponatremia were homozygous for a novel missense variant (p.His121Gln). Deleterious CFTR variants were absent in both pedigrees. CA XII protein was localized apically in human bronchiolar epithelia and basolaterally in the reabsorptive duct of human sweat glands. Respiratory epithelial cell RNA from the adult proband revealed only aberrant CA12 transcripts and in vitro analysis showed greatly reduced CA XII protein. Studies of ion transport across respiratory epithelial cells in vivo and in culture revealed intact CFTR-mediated chloride transport in the adult proband. CA XII protein bearing either p.His121Gln or a previously identified p.Glu143Lys missense variant localized to the basolateral membranes of polarized Madin-Darby canine kidney (MDCK) cells, but enzyme activity was severely diminished when assayed at physiologic concentrations of extracellular chloride. Our findings indicate that loss of CA XII function should be considered in individuals without CFTR mutations who exhibit CF-like features in the sweat gland and lung.


Asunto(s)
Anhidrasas Carbónicas/genética , Regulador de Conductancia de Transmembrana de Fibrosis Quística/genética , Fibrosis Quística/genética , Enfermedades Pulmonares/genética , Sudor/metabolismo , Adolescente , Adulto , Animales , Anhidrasas Carbónicas/biosíntesis , Anhidrasas Carbónicas/metabolismo , Niño , Preescolar , Cloruros/metabolismo , Fibrosis Quística/metabolismo , Fibrosis Quística/fisiopatología , Perros , Femenino , Regulación Enzimológica de la Expresión Génica , Homocigoto , Humanos , Pulmón/enzimología , Pulmón/patología , Enfermedades Pulmonares/metabolismo , Enfermedades Pulmonares/fisiopatología , Células de Riñón Canino Madin Darby , Masculino , Mutación , Linaje , Fenotipo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA