Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
AJR Am J Roentgenol ; 222(3): e2329778, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37991334

RESUMEN

BACKGROUND. The higher spatial resolution and image contrast for iodine-containing tissues of photon-counting detector (PCD) CT may address challenges in evaluating small calcified vessels when performing lower extremity CTA by energy-integrating detector (EID) CTA. OBJECTIVE. The purpose of the study was to compare the evaluation of infrapopliteal vasculature between lower extremity CTA performed using EID CT and PCD CT. METHODS. This prospective study included 32 patients (mean age, 69.7 ± 11.3 [SD] years; 27 men, five women) who underwent clinically indicated lower extremity EID CTA between April 2021 and March 2022; participants underwent investigational lower extremity PCD CTA later the same day as EID CTA using a reduced IV contrast media dose. Two radiologists independently reviewed examinations in two sessions, each containing a random combination of EID CTA and PCD CTA examinations; the readers assessed the number of visualized fibular perforators, characteristics of stenoses at 11 infrapopliteal segmental levels, and subjective arterial sharpness. RESULTS. Mean IV contrast media dose was 60.0 ± 11.0 (SD) mL for PCD CTA versus 139.6 ± 11.8 mL for EID CTA (p < .001). The number of identified fibular perforators per lower extremity was significantly higher for PCD CTA than for EID CTA for reader 1 (R1) (mean ± SD, 6.4 ± 3.2 vs 4.2 ± 2.4; p < .001) and reader 2 (R2) (8.8 ± 3.4 vs 7.6 ± 3.3; p = .04). Reader confidence for assessing stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 82.3 ± 20.3 vs 78.0 ± 20.2; p < .001) but not R2 (89.8 ± 16.7 vs 90.6 ± 7.1; p = .24). The number of segments per lower extremity with total occlusion was significantly lower for PCD CTA than for EID CTA for R2 (mean ± SD, 0.5 ± 1.3 vs 0.9 ± 1.7; p = .04) but not R1 (0.6 ± 1.3 vs 1.0 ± 1.5; p = .07). The number of segments per lower extremity with clinically significant nonocclusive stenosis was significantly higher for PCD CTA than for EID CTA for R1 (mean ± SD, 2.2 ± 2.2 vs 1.6 ± 1.7; p = .01) but not R2 (1.1 ± 2.0 vs 1.1 ± 1.4; p = .89). Arterial sharpness was significantly greater for PCD CTA than for EID CTA for R1 (mean ± SD, 3.2 ± 0.5 vs 1.8 ± 0.5; p < .001) and R2 (3.2 ± 0.4 vs 1.7 ± 0.8; p < .001). CONCLUSION. PCD CTA yielded multiple advantages relative to EID CTA for visualizing small infrapopliteal vessels and characterizing associated plaque. CLINICAL IMPACT. The use of PCD CTA may improve vascular evaluation in patients with peripheral arterial disease.


Asunto(s)
Medios de Contraste , Fotones , Masculino , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Estudios Prospectivos , Constricción Patológica , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Extremidad Inferior/diagnóstico por imagen
2.
Dis Colon Rectum ; 66(2): 243-252, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36538706

RESUMEN

BACKGROUND: Refractory perianal Crohn's disease remains notoriously difficult to treat. We developed a novel technology using a commercially available bioabsorbable fistula plug to deliver autologous adipose-derived mesenchymal stem cells. OBJECTIVE: This study aimed to assess therapeutic safety and feasibility in the completed STOMP (stem cells on matrix plugs) phase 1 clinical trial. DESIGN: Prospective single-arm phase I clinical trial. SETTING: Tertiary academic medical center. PATIENTS: Adults (aged 18-65 y) with complex single-tract Crohn's disease perianal fistula who have failed conventional therapy were included in this study. INTERVENTION: Autologous adipose-derived mesenchymal stem cells were isolated, ex vivo culture expanded, and seeded onto a commercially available bioabsorbable fistula plug. Six weeks later, patients returned to the operating room for removal of the seton and placement of the stem cell-loaded plug. MAIN OUTCOME MEASURES: Patients were followed up for a total of 8 visits through 12 months. Safety was the primary end point; clinical healing and MRI response were secondary end points. RESULTS: Twenty patients (12 females; mean age 36 y) were treated with the stem cell-loaded plug. Of the 20 patients enrolled, 3 were not included in the 12-month analysis because of study withdrawal. Through 12 months, no patient experienced a serious adverse event related to the stem cell-loaded plug. Four patients experienced 7 serious adverse events and 12 patients experienced 22 adverse events. Complete clinical healing occurred in 14 of 18 patients at 6 months and 13 of 17 patients at 12 months. MRI response was observed in 12 of 18 patients at 6 months. LIMITATIONS: The main limitations were the small sample size and restrictive inclusion criteria. CONCLUSIONS: A stem cell-loaded plug can safely and effectively deliver cell-based therapy for patients with single-tract fistulizing perianal Crohn's disease. See Video Abstract at http://links.lww.com/DCR/C70 . RESPUESTA DURADERA OBSERVADA EN PACIENTES CON ENFERMEDAD DE CROHN PERIANAL FISTULIZANTE REFRACTARIA MEDIANTE EL USO DE CLULAS MADRE MESENQUIMALES AUTLOGAS EN UNA MATRIZ DISOLUBLE RESULTADOS DEL ENSAYO DE FASE I STEM CELL ON MATRIX PLUG: ANTECEDENTES:La enfermedad de Crohn perianal refractaria sigue siendo notoriamente difícil de tratar. Desarrollamos una tecnología novedosa utilizando un tapón de fístula bioabsorbible disponible comercialmente para administrar células madre mesenquimales derivadas de tejido adiposo autólogo.OBJETIVO:Evaluar la seguridad y viabilidad terapéutica en el ensayo finalizado STOMP.DISEÑO:Ensayo clínico prospectivo de fase I de un solo brazo.AJUSTE:Centro médico académico terciario.PACIENTES:Adultos (18-65) con fístula perianal compleja de la enfermedad de Crohn de un solo tracto que han fracasado con la terapia convencional.INTERVENCIÓN:Se aislaron células madre mesenquimales derivadas de tejido adiposo autólogo, se expandieron en cultivo ex vivo y se sembraron en un tapón de fístula bioabsorbible disponible comercialmente. Seis semanas después, los pacientes regresaron al quirófano para retirar el setón y colocar el tapón cargado de células madre.PRINCIPALES MEDIDAS DE RESULTADO:Los pacientes fueron seguidos durante un total de 8 visitas durante 12 meses. La seguridad fue el criterio principal de valoración; la curación clínica y la respuesta a la resonancia magnética fueron criterios de valoración secundarios.RESULTADOS:Veinte pacientes (12 mujeres, edad media 36 años) fueron tratados con el tapón cargado de células madre. De los 20 pacientes inscritos, tres no se incluyeron en el análisis de 12 meses porque se retiraron del estudio. A lo largo de 12 meses, ningún paciente experimentó un evento adverso grave relacionado con el tapón cargado de células madre. Cuatro pacientes experimentaron 7 eventos adversos graves y 12 pacientes experimentaron 22 eventos adversos. La curación clínica completa ocurrió en 14 de 18 pacientes a los 6 meses y en 13 de 17 pacientes a los 12 meses. La respuesta a la resonancia magnética se observó en 12 de 18 pacientes a los 6 meses.LIMITACIONES:Las principales limitaciones son el tamaño pequeño de la muestra y los criterios de inclusión restrictivos.CONCLUSIONES:Un tapón cargado de células madre se puede administrar de manera segura y efectiva, una terapia basada en células para pacientes con enfermedad de Crohn perianal fistulizante de un solo tracto. Consule Video Resumen en http://links.lww.com/DCR/C70 . (Traducción- Dr. Yesenia Rojas-Khalil ).


Asunto(s)
Enfermedad de Crohn , Células Madre Mesenquimatosas , Fístula Rectal , Adulto , Femenino , Humanos , Enfermedad de Crohn/complicaciones , Enfermedad de Crohn/terapia , Estudios Prospectivos , Fístula Rectal/etiología , Fístula Rectal/terapia , Estudios Retrospectivos , Células Madre
3.
AJR Am J Roentgenol ; 220(1): 73-85, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-35731096

RESUMEN

BACKGROUND. Anatomic redundancy between phases can be used to achieve denoising of multiphase CT examinations. A limitation of iterative reconstruction (IR) techniques is that they generally require use of CT projection data. A frequency-split multi-band-filtration algorithm applies denoising to the multiphase CT images themselves. This method does not require knowledge of the acquisition process or integration into the reconstruction system of the scanner, and it can be implemented as a supplement to commercially available IR algorithms. OBJECTIVE. The purpose of the present study is to compare radiologists' performance for low-contrast and high-contrast diagnostic tasks (i.e., tasks for which differences in CT attenuation between the imaging target and its anatomic background are subtle or large, respectively) evaluated on multiphase abdominal CT between routine-dose images and radiation dose-reduced images processed by a frequency-split multiband-filtration denoising algorithm. METHODS. This retrospective single-center study included 47 patients who underwent multiphase contrast-enhanced CT for known or suspected liver metastases (a low-contrast task) and 45 patients who underwent multiphase contrast-enhanced CT for pancreatic cancer staging (a high-contrast task). Radiation dose-reduced images corresponding to dose reduction of 50% or more were created using a validated noise insertion technique and then underwent denoising using the frequency-split multi-band-filtration algorithm. Images were independently evaluated in multiple sessions by different groups of abdominal radiologists for each task (three readers in the low-contrast arm and four readers in the high-contrast arm). The noninferiority of denoised radiation dose-reduced images to routine-dose images was assessed using the jackknife alternative free-response ROC (JAFROC) figure-of-merit (FOM; limit of noninferiority, -0.10) for liver metastases detection and using the Cohen kappa statistic and reader confidence scores (100-point scale) for pancreatic cancer vascular invasion. RESULTS. For liver metastases detection, the JAFROC FOM for denoised radiation dose-reduced images was 0.644 (95% CI, 0.510-0.778), and that for routine-dose images was 0.668 (95% CI, 0.543-0.792; estimated difference, -0.024 [95% CI, -0.084 to 0.037]). Intraobserver agreement for pancreatic cancer vascular invasion was substantial to near perfect when the two image sets were compared (κ = 0.53-1.00); the 95% CIs of all differences in confidence scores between image sets contained zero. CONCLUSION. Multiphase contrast-enhanced abdominal CT images with a radiation dose reduction of 50% or greater that undergo denoising by a frequency-split multiband-filtration algorithm yield performance similar to that of routine-dose images for detection of liver metastases and vascular staging of pancreatic cancer. CLINICAL IMPACT. The image-based denoising algorithm facilitates radiation dose reduction of multiphase examinations for both low- and high-contrast diagnostic tasks without requiring manufacturer-specific hardware or software.


Asunto(s)
Neoplasias Hepáticas , Tomografía Computarizada por Rayos X , Humanos , Estudios Retrospectivos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Neoplasias Hepáticas/diagnóstico por imagen , Algoritmos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
4.
Acta Radiol ; 63(11): 1443-1452, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34723681

RESUMEN

BACKGROUND: Dual-energy virtual monoenergetic images can increase iodine signal, potentially increasing the conspicuity of hepatic masses. PURPOSE: To determine if dual-energy 50-keV virtual monoenergetic images improve visualization of key imaging findings or diagnostic confidence for small (≤2 cm) hepatocellular carcinomas (HCC) at multiphase, contrast-enhanced liver computed tomography (CT). MATERIAL AND METHODS: Patients with chronic liver disease underwent multiphase dual-energy CT imaging for HCC, with late arterial and delayed phase dual-energy 50-keV images reconstructed. Two non-reader subspecialized gastrointestinal (GI) radiologists established the reference standard, determining the location and diagnosis of all hepatic lesions using predetermined criteria. Three GI radiologists interpreted mixed kV CT images without or with dual-energy 50-keV images. Radiologists identified potential HCCs and rated their confidence (0-100 scales) in imaging findings of arterial enhancement, enhancing capsule, tumor washout, and LI-RADS 5 (2018) category. RESULTS: In total, 45 patients (14 women; mean age = 59.5 ± 10.9 years) with chronic liver disease were included. Of them, 19 patients had 25 HCCs ≤2 cm (mean size = 1.5 ± 0.4 cm). There were 17 LI-RADS 3 and 4 lesions and 19 benign lesions. Reader confidence in imaging findings of arterial enhancement, enhancing capsule, and non-peripheral washout significantly increased with dual-energy images (P ≤ 0.022). Overall confidence in HCC diagnosis increased significantly with dual-energy 50-keV images (52.4 vs. 68.8; P = 0.001). Dual-energy images demonstrated a slight but significant decrease in overall image quality. CONCLUSION: Radiologist confidence in key imaging features of small HCCs and confidence in imaging diagnosis increases with use of dual-energy 50-keV images at multiphase, contrast-enhanced liver CT.


Asunto(s)
Carcinoma Hepatocelular , Yodo , Neoplasias Hepáticas , Imagen Radiográfica por Emisión de Doble Fotón , Anciano , Carcinoma Hepatocelular/diagnóstico por imagen , Femenino , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Radiólogos , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
5.
Vascular ; 29(6): 927-937, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33459205

RESUMEN

OBJECTIVE: This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. METHODS: After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into "not opacified", "<50% stenosis", " 50 ̶70% stenosis", ">70% stenosis", and "occluded" for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. RESULTS: Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8-32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively (p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus (p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) (p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients (p = 0.319), respectively. CONCLUSION: Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste/administración & dosificación , Yohexol/administración & dosificación , Extremidad Inferior/irrigación sanguínea , Enfermedad Arterial Periférica/diagnóstico por imagen , Anciano , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad
6.
Neurourol Urodyn ; 39(5): 1387-1393, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32544300

RESUMEN

PURPOSE: To determine the relationship among flow index (FI), uroflowmetry curve shape, and electromyography (EMG) lag time in children. MATERIALS AND METHODS: A total of 294 children with lower urinary tract symptoms were included. The overall relationship between lag time and FI was investigated with curve estimation regression. Normal and primary bladder neck dysfunction was defined according to the previous classification, while patients with a lag time less than 2 seconds were grouped based on 2-second intervals. We also categorized cases into four groups (tower shaped, bell shaped, plateau shaped, and fractionated void) by FI and compared lag time. RESULTS: The overall distribution chart demonstrated that FI was the highest at lag time 0 second and decreased with the change in lag time both ways. The best fitting model for maximum FI and lag time was a cubic model (R2 = .282; P < .001). Children with lag times from 0 to less than 2 seconds showed the highest mean FI, while those with prolonged (>6 seconds) or delayed lag time (<-4 seconds) demonstrated lower mean FI values. EMG lag time of the tower-shaped curve was significantly close to 0 second, and plateau shaped and fractionated void had either prolonged or delayed. CONCLUSIONS: A lag time close to 0 second was associated with higher FI, representing hyperefficient voiding with a tower-shaped flow pattern. However, children with prolonged or delayed lag time showed a lower FI, implicating hypoefficient voiding and a plateau-shaped flow pattern. The relationship between FI and EMG lag time could be a cornerstone for a comprehensive understanding of voiding status.


Asunto(s)
Síntomas del Sistema Urinario Inferior/fisiopatología , Vejiga Urinaria/fisiopatología , Micción/fisiología , Urodinámica/fisiología , Niño , Preescolar , Electromiografía , Femenino , Humanos , Masculino , Estudios Retrospectivos
7.
Acta Radiol ; 61(9): 1186-1195, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31986894

RESUMEN

BACKGROUND: Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. PURPOSE: To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. MATERIAL AND METHODS: CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. RESULTS: Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18-1.28 vs. 1.02-1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar (P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). CONCLUSION: This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.


Asunto(s)
Algoritmos , Medios de Contraste/administración & dosificación , Radiografía Abdominal/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Tamaño Corporal , Peso Corporal , Estudios de Casos y Controles , Femenino , Humanos , Yodo , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
8.
J Comput Assist Tomogr ; 43(4): 612-618, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31268876

RESUMEN

OBJECTIVE: The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. METHODS: The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. RESULTS: The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. CONCLUSION: The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.


Asunto(s)
Abdomen , Aorta/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Medios de Contraste , Yodo , Abdomen/irrigación sanguínea , Abdomen/diagnóstico por imagen , Anciano , Angiografía por Tomografía Computarizada/métodos , Angiografía por Tomografía Computarizada/estadística & datos numéricos , Medios de Contraste/administración & dosificación , Medios de Contraste/uso terapéutico , Humanos , Yodo/administración & dosificación , Yodo/uso terapéutico , Masculino , Radiografía Abdominal , Estudios Retrospectivos , Factores de Tiempo
9.
Biochim Biophys Acta ; 1842(12 Pt B): 2579-83, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25108282

RESUMEN

Adenylyl cyclases (ACs) are a family of enzymes which convert ATP to cAMP, an essential intermediate in many signal transduction pathways. Of the 10 AC genes in man, 9 fall into the category of transmembrane ACs (tmACs), which associate with G-protein coupled receptors (GPCRs) and are activated by forskolin. The 10th AC, termed soluble AC (sAC) is neither activated by forskolin nor does it interact with GPCRs. Rather, sAC can be found in many compartments within the cell and is activated by bicarbonate. As such, sAC is considered a major sensor of bicarbonate in many tissues. The pathways involving sAC vary in different tissues and organ systems, and are as diverse as facilitating sperm capacitation and regulating pressure in the eye. The role of sAC in the eye has only recently begun to receive significant attention. Here we summarize what is known about the roles of sAC in the eye. This article is part of a Special Issue entitled: The role of soluble adenylyl cyclase in health and disease.


Asunto(s)
Adenilil Ciclasas/metabolismo , Ojo/enzimología , Animales , Humanos
10.
J Biol Chem ; 286(48): 41353-41358, 2011 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-21994938

RESUMEN

Glaucoma is a leading cause of blindness affecting as many as 2.2 million Americans. All current glaucoma treatment strategies aim to reduce intraocular pressure (IOP). IOP results from the resistance to drainage of aqueous humor (AH) produced by the ciliary body in a process requiring bicarbonate. Once secreted into the anterior chamber, AH drains from the eye via two pathways: uveoscleral and pressure-dependent or conventional outflow (C(t)). Modulation of "inflow" and "outflow" pathways is thought to occur via distinct, local mechanisms. Mice deficient in the bicarbonate channel bestrophin-2 (Best2), however, exhibit a lower IOP despite an increase in AH production. Best2 is expressed uniquely in nonpigmented ciliary epithelial (NPE) cells providing evidence for a bicarbonate-dependent communicative pathway linking inflow and outflow. Here, we show that bicarbonate-sensitive soluble adenylyl cyclase (sAC) is highly expressed in the ciliary body in NPE cells, but appears to be absent from drainage tissues. Pharmacologic inhibition of sAC in mice causes a significant increase in IOP due to a decrease in C(t) with no effect on inflow. In mice deficient in sAC IOP is elevated, and C(t) is decreased relative to wild-type mice. Pharmacologic inhibition of sAC did not alter IOP or C(t) in sAC-deficient mice. Based on these data we propose that the ciliary body can regulate C(t) and that sAC serves as a critical sensor of bicarbonate in the ciliary body regulating the secretion of substances into the AH that govern outflow facility independent of pressure.


Asunto(s)
Adenilil Ciclasas/metabolismo , Bicarbonatos/metabolismo , Cuerpo Ciliar/enzimología , Glaucoma/enzimología , Presión Intraocular , Adenilil Ciclasas/genética , Animales , Humor Acuoso/enzimología , Bestrofinas , Canales de Cloruro/genética , Canales de Cloruro/metabolismo , Proteínas del Ojo/genética , Proteínas del Ojo/metabolismo , Glaucoma/epidemiología , Glaucoma/genética , Humanos , Ratones , Ratones Noqueados , Porcinos
11.
Aliment Pharmacol Ther ; 55(12): 1560-1568, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35274320

RESUMEN

BACKGROUND: Most patients experience good functional outcomes following ileal pouch-anal anastomosis (IPAA) for ulcerative colitis. AIM: We aimed to determine if asymptomatic patients with an IPAA had findings consistent with normal defecation on standard objective anorectal tests. METHODS: Patients 18-65 years old with IPAA and self-reported healthy pouch function were recruited. Patients with chronic pouchitis, Crohn's disease, anastomotic stricture, or indication for IPAA other than ulcerative or indeterminate colitis were excluded. Patients underwent an interview with an abbreviated Rome Questionnaire followed by high-resolution ano-pouch manometry, balloon expulsion test, pouch barostat, and magnetic resonance (MR) defecography. RESULTS: Twenty patients completed all testing. Six patients were excluded from the final analysis due to symptoms suggestive of pouch evacuation disorder on the abbreviated Rome Questionnaire (n = 2), structural abnormality on MR imaging (n = 3), or both (n = 1). Of the remaining 14 patients, mean anal resting pressure during high-resolution manometry was 72 ± 16 mmHg, mean anal squeeze pressure was 247 ± 69 mmHg, and mean pouch-anal gradient during the simulated evacuation was -27 ± 37 mmHg. The meantime to balloon expulsion was 54 seconds. During dynamic MR defecography, the mean descent of ano-pouch junction was 2.6 cm, and mean pouch evacuation was 44.5% and 74.2% pre- and posttoilet phase, respectively. CONCLUSIONS: A substantial proportion of patients with IPAA and self-reported healthy pouch function have anatomic and/or functional abnormalities of the pouch. In asymptomatic IPAA patients with an anatomically normal pouch, we have proposed normal parameters for high-resolution ano-pouch manometry, time to balloon expulsion, pouch barostat, and MR defecography.


Asunto(s)
Colitis Ulcerosa , Reservorios Cólicos , Reservoritis , Proctocolectomía Restauradora , Adolescente , Adulto , Anciano , Canal Anal/diagnóstico por imagen , Canal Anal/cirugía , Anastomosis Quirúrgica/efectos adversos , Reservorios Cólicos/efectos adversos , Humanos , Persona de Mediana Edad , Proyectos Piloto , Reservoritis/diagnóstico por imagen , Reservoritis/etiología , Proctocolectomía Restauradora/efectos adversos , Adulto Joven
12.
Abdom Radiol (NY) ; 47(6): 2158-2167, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35320381

RESUMEN

PURPOSE: To compare the utility of a novel metal artifact reduction algorithm to standard imaging in improving visualization of key structures, diagnostic confidence, and patient-level confidence in malignancy in patients with suspected bladder cancer. METHODS: Patients with hip implants undergoing CT urography for suspected bladder malignancy were enrolled. Images were reconstructed using 3 methods: (1) Filtered Back Projection (FBP), (2) Iterative Metal Artifact Reduction (iMAR), and (3) Adaptive Iterative Metal Artifact Reduction (AiMAR) strength 4. In multiple reading sessions, three radiologists graded visualization of critical anatomic structures and artifact severity (6-point scales, lower scores desirable), and diagnostic confidence in blinded fashion. They also graded patient-level confidence in malignancy based on imaging findings in each patient. RESULTS: Thirty-two patients (8 females) with a mean age of 74.5 ± 8.5 years were included. The median (range) visualization scores for FBP, iMAR, and AiMAR were 3.6 (1.1-4.9), 1.6 (0.3-2.8), and 1.6 (0.3-2.6), respectively. Both iMAR and AiMAR had anatomic visualization and artifact scores better than FBP (P < 0.001 for both) and similar to each other (P > 0.05). Structures with the most improvement in visualization score with the use of metal artifact reduction algorithms included the obturator internus muscle, internal and external iliac nodal chains, and vagina. iMAR and AiMAR improved diagnostic confidence (P < 0.001) and patient-level confidence in malignancy (P ≤ 0.24). CONCLUSION: For patients with hip prostheses and suspected bladder malignancy, the use of iMAR or AiMAR was shown to significantly reduce metal artifacts, thus improving diagnostic confidence and patient-level confidence in malignancy.


Asunto(s)
Prótesis de Cadera , Neoplasias de la Vejiga Urinaria , Anciano , Anciano de 80 o más Años , Algoritmos , Artefactos , Femenino , Humanos , Masculino , Metales , Tomografía Computarizada por Rayos X/métodos , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen
13.
Crohns Colitis 360 ; 4(1): otac003, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36777547

RESUMEN

Background: To describe response to therapy of small bowel (SB) Crohn's disease (CD) at CT or MR enterography (CTE/MRE) in patients on vedolizumab. Methods: Patients with SB CD who underwent CTE/MRE exams greater than 12 months apart on vedolizumab therapy were included. Length (in cm) and inflammation severity (EMBARK score) of inflamed SB segments were assessed. Changes in inflammation length of 3.4 cm or greater or inflammation severity of 2 EMBARK points or greater was categorized as response or progression, as appropriate, with development of newly inflamed segments, strictures, or penetrating complications also indicating progression. Patients not meeting the criteria for response or progression were categorized as having stable disease. Results: Of 36 SB CD patients, the large majority had prior surgery (86%; 31), anti-TNF use (92%; 33), and internal penetrating (78%; 28) disease. Thirty-two patients had paired baseline and follow-up CTE/MRE exams without interval surgery, with clinical response observed in 24/32 (75%). Based on imaging response criteria, 22% (7/32; 95% CI: 9%-40%) had response, 50% (16/32; 95% CI: 32%-68%) were stable, and 28% (9/32; 95% CI: 14%-47%) had disease progression. Fifty-six percent of (18/32; 95% CI: 38%-74%) patients had clinical improvement with response or stable disease by imaging. Patients with stable disease had shorter median baseline lengths of SB inflammation (P = .012). Proportion of patients with colonic inflammation, perianal disease, or penetrating complications did not change. Conclusions: Most patients on vedolizumab for over 12 months demonstrated response or stable SB disease when using objective cross-sectional radiologic imaging criteria using CTE/MRE.

14.
Invest Radiol ; 57(11): 734-741, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-35703439

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the clinical impact of a higher spatial resolution, full field-of-view investigational photon-counting detector computed tomography (PCD-CT) on radiologist confidence in imaging findings and diagnosis of usual interstitial pneumonia (UIP) compared with conventional energy-integrating detector CT (EID-CT). MATERIALS AND METHODS: Patients suspected of interstitial lung disease were scanned on a PCD-CT system after informed consent and a clinically indicated EID-CT. In 2 sessions, 3 thoracic radiologists blinded to clinical history and scanner type evaluated CT images of the right and left lungs separately on EID- or PCD-CT, reviewing each lung once/session, rating confidence in imaging findings of reticulation, traction bronchiectasis, honeycombing, ground-glass opacities (GGOs), mosaic pattern, and lower lobe predominance (100-point scale: 0-33, likely absent; 34-66, indeterminate; 67-100, likely present). Radiologists also rated confidence for the probability of UIP (0-20, normal; 21-40, inconsistent with UIP; 41-60, indeterminate UIP; 61-81; probable UIP; 81-100, definite UIP) and graded image quality. Because a confidence scale of 50 represented completely equivocal findings, magnitude score (the absolute value of confidence scores from 50) was used for analysis (higher scores were more confident). Image noise was measured for each modality. The magnitude score was compared using linear mixed effects regression. The consistency of findings and diagnosis between 2 scanners were evaluated using McNemar test and weighted κ statistics, respectively. RESULTS: A total of 30 patients (mean age, 68.8 ± 11.0 years; M:F = 18:12) underwent conventional EID-CT (median CTDI vol , 7.88 mGy) and research PCD-CT (median CTDI vol , 6.49 mGy). The magnitude scores in PCD-CT were significantly higher than EID-CT for imaging findings of reticulation (40.7 vs 38.3; P = 0.023), GGO (34.4 vs 31.7; P = 0.019), and mosaic pattern (38.6 vs 35.9; P = 0.013), but not for other imaging findings ( P ≥ 0.130) or confidence in UIP (34.1 vs 22.2; P < 0.059). Magnitude score of probability of UIP in PCD-CT was significantly higher than EID-CT in one reader (26.0 vs 21.5; P = 0.009). Photon-counting detector CT demonstrated a decreased number of indeterminate GGO (17 vs 26), an increased number of unlikely GGO (74 vs 50), and an increased number of likely reticulations (140 vs 130) relative to EID-CT. Interobserver agreements among 3 readers for imaging findings and probability of UIP were similar between PCD-CT and EID-CT (intraclass coefficient: 0.507-0.818 vs 0.601-0.848). Photon-counting detector CT had higher scores in overall image quality (4.84 ± 0.38) than those in EID-CT (4.02 ± 0.40; P < 0.001) despite increased image noise (mean 85.5 vs 36.1 HU). CONCLUSIONS: Photon-counting detector CT provided better image quality and improved the reader confidence for presence or absence of imaging findings of reticulation, GGO, and mosaic pattern with idiosyncratic improvement in confidence in UIP presence.


Asunto(s)
Fibrosis Pulmonar Idiopática , Anciano , Humanos , Pulmón/diagnóstico por imagen , Persona de Mediana Edad , Fantasmas de Imagen , Fotones , Tomografía Computarizada por Rayos X/métodos
15.
Cureus ; 13(5): e15173, 2021 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-34178495

RESUMEN

Renal cell carcinoma (RCC) is a rare malignancy that often metastasizes to the lung, bones, liver, and brain. Only a few cases of RCC metastasis in periocular areas have been reported in the literature. This case report describes a 70-year-old male who was presented to the University of Florida, Gainesville ophthalmology clinic with two-day symptoms of diplopia, decreased vision, and mechanical ptosis of the left eye with superior temporal mass. The patient had a history of both prostate and RCC that were in remission for five years leading to his presentation. Excisional biopsy confirmed the metastasis of RCC to the eye. The patient reported no systemic symptoms. This report also reviews existing literature on RCC metastasis to the eye and orbit. Ultimately, RCC metastasis to the eye in patients with a history of known RCC should be considered in the differential diagnosis in those presenting with an atypical mass in periocular regions.

16.
J Clin Imaging Sci ; 11: 52, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34621597

RESUMEN

OBJECTIVES: The objectives of the study were to estimate the impact of high matrix image reconstruction on chest computed tomography (CT) compared to standard image reconstruction. MATERIAL AND METHODS: This retrospective study included patients with interstitial or parenchymal lung disease, airway disease, and pulmonary nodules who underwent chest CT. Chest CT images were reconstructed using high matrix (1024 × 1024) or standard matrix (512 × 512), with all other parameters matched. Two radiologists, blinded to reconstruction technique, independently examined each lung, viewing image sets side by side and rating the conspicuity of imaging findings using a 5-point relative conspicuity scale. The presence of pulmonary nodules and confidence in classification of internal attenuation was also graded. Overall image quality and subjective noise/artifacts were assessed. RESULTS: Thirty-four patients with 68 lungs were evaluated. Relative conspicuity scores were significantly higher using high matrix image reconstruction for all imaging findings indicative of idiopathic lung fibrosis (peripheral airway visualization, interlobular septal thickening, intralobular reticular opacity, and end-stage fibrotic change; P ≤ 0.001) along with emphysema, mosaic attenuation, and fourth order bronchi for both readers (P ≤ 0.001). High matrix reconstruction did not improve confidence in the presence or classification of internal nodule attenuation for either reader. Overall image quality was increased but not subjective noise/artifacts with high matrix image reconstruction for both readers (P < 0.001). CONCLUSION: High matrix image reconstruction significantly improves the conspicuity of imaging findings reflecting interstitial lung disease and may be useful for diagnosis or treatment response assessment.

17.
Acta Radiol Open ; 10(7): 20584601211030658, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34377539

RESUMEN

BACKGROUND: Due to their easy accessibility, CT scans have been increasingly used for investigation of gastrointestinal (GI) bleeding. PURPOSE: To estimate the performance of a dual-phase, dual-energy (DE) GI bleed CT protocol in patients with overt GI bleeding in clinical practice and examine the added value of portal phase and DE images. MATERIALS AND METHODS: Consecutive patients with GI bleeding underwent a two-phase DE GI bleed CT protocol. Two gastroenterologists established the reference standard. Performance was estimated using clinical CT reports. Three GI radiologists rated confidence in GI bleeding in a subset of 62 examinations, evaluating first mixed kV arterial images, then after examining additional portal venous phase images, and finally after additional DE images (virtual non-contrast and virtual monoenergetic 50 keV images). RESULTS: 52 of 176 patients (29.5%) had GI bleeding by the reference standard. The overall sensitivity, specificity, and positive and negative predictive values of the CT GI bleed protocol for detecting GI bleeding were 65.4%, 89.5%, 72.3%, and 86.0%, respectively. In patients with GI bleeding, diagnostic confidence of readers increased after adding portal phase images to arterial phase images (p = 0.002), without additional benefit from dual energy images. In patients without GI bleeding, confidence in luminal extravasation appropriately decreased after adding portal phase, and subsequently DE images (p = 0.006, p = 0.018). CONCLUSION: A two-phase DE GI bleed CT protocol had high specificity and negative predictive value in clinical practice. Portal venous phase images improved diagnostic confidence in comparison to arterial phase images alone. Dual-energy images further improved radiologist confidence in the absence of bleeding.

18.
J Biomed Mater Res B Appl Biomater ; 108(5): 1907-1914, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-31785088

RESUMEN

Subfailure ligament and tendon injury remain a significant burden to global healthcare. Here, we present the use of biocompatible single-walled carbon nanohorns (CNH) as a potential treatment for the repair of sub-failure injury in tendons. First, in vitro exposure of CNH to human tenocytes revealed no change in collagen deposition but a significant decrease in cell metabolic activity after 14 days. Additionally, gene expression studies revealed significant downregulation of collagen Types I and III mRNA at 7 days with some recovery after 14 days of exposure. Biomechanical tests with explanted porcine digitorum tendons showed the ability of CNH suspensions to modulate tendon biomechanics, most notably elastic moduli immediately after treatment. in vivo experiments demonstrated the ability of CNH to persist in the damaged matrix of stretch-injured Sprague Dawley rat Achilles tendon but not significantly modify tendon biomechanics after 7 days of treatment. Although these results demonstrate the early feasibility of utility of CNH as a potential modality for tendon subfailure injury, additional work is needed to further validate and ensure clinical efficacy.


Asunto(s)
Carbono/química , Colágeno/metabolismo , Nanopartículas/metabolismo , Traumatismos de los Tendones/terapia , Tenocitos/efectos de los fármacos , Tendón Calcáneo/lesiones , Animales , Fenómenos Biomecánicos , Colágeno Tipo I/genética , Colágeno Tipo I/metabolismo , Colágeno Tipo III/genética , Colágeno Tipo III/metabolismo , Módulo de Elasticidad/efectos de los fármacos , Femenino , Humanos , Pruebas Mecánicas , Nanopartículas/química , Ratas Sprague-Dawley , Porcinos , Tenocitos/citología , Ingeniería de Tejidos
19.
J Crohns Colitis ; 14(4): 455-464, 2020 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-31960900

RESUMEN

BACKGROUND AND AIMS: Our goal was to determine the importance of ileal inflammation at computed tomography or magnetic resonance enterography in Crohn's disease patients with normal ileoscopy. METHODS: Patients with negative ileoscopy and biopsy within 30 days of CT or MR enterography showing ileal inflammation were included. The severity [0-3 scale] and length of inflammation within the distal 20 cm of the terminal ileum were assessed on enterography. Subsequent medical records were reviewed for ensuing surgery, ulceration at ileoscopy, histological inflammation, or new or worsening ileal inflammation or stricture on enterography. Imaging findings were classified as: Confirmed Progression [subsequent surgery or radiological worsening, new ulcers at ileoscopy or positive histology]; Radiologic Response [decreased inflammation with medical therapy]; or Unlikely/Unconfirmed Inflammation. RESULTS: Of 1471 patients undergoing enterography and ileoscopy, 112 [8%] had imaging findings of inflammation with negative ileoscopy, and 88 [6%] had negative ileoscopy and ileal biopsy. Half [50%; 44/88] with negative biopsy had moderate/severe inflammation at enterography, with 45%, 32% and 11% having proximal small bowel inflammation, stricture or fistulas, respectively. Two-thirds with negative biopsy [67%; 59/88] had Confirmed Progression, with 68%, 70% and 61% having subsequent surgical resection, radiological worsening or ulcers at subsequent ileoscopy, respectively. Mean length and severity of ileal inflammation in these patients was 10 cm and 1.6. Thirteen [15%] patients had Radiologic Response, and 16 [18%] had Unlikely/Unconfirmed Inflammation. CONCLUSION: Crohn's disease patients with unequivocal imaging findings of ileal inflammation at enterography despite negative ileoscopy and biopsy are likely to have active inflammatory Crohn's disease. Disease detected by imaging may worsen over time or respond to medical therapy.


Asunto(s)
Biopsia/métodos , Enfermedad de Crohn , Endoscopía Gastrointestinal/métodos , Íleon , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Enfermedad de Crohn/diagnóstico , Enfermedad de Crohn/patología , Diagnóstico Diferencial , Femenino , Humanos , Íleon/diagnóstico por imagen , Íleon/patología , Inflamación/patología , Masculino , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
20.
Abdom Radiol (NY) ; 45(3): 623-631, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31980866

RESUMEN

PURPOSE: To determine how small bowel neuroendocrine neoplasms (SBNEN's) are diagnosed and examine the effect of CT enterography (CTE) on diagnosis and rates of disease-free survival. METHODS: Histopathologically-confirmed SBNEN's diagnosed at our institution between 1996 and 2016 were identified. Clinical presentation, radiology, endoscopy, surgery, and pathology reports were reviewed and compared between consecutive 5-year periods. RESULTS: Of the 178 SBNEN initially diagnosed at our institution, the incidence increased 12-fold from 9 (during 1996-2000) to 114 (during 2011-2016). Comparing the first 5 to the last 5 years, GI bleeding and abdominal pain increased significantly as indications (with both increasing from 0 to > 25%, p ≤ 0.023). Initial diagnosis by radiology increased 2-fold [from 33% (n = 3) to 66% (n = 75); p = 0.263]. Detection of a small bowel mass and the suggestion that SBNEN was present varied significantly between imaging modalities (p < 0.0001; CTE - 95% (52/55) and 91% (50/55) vs. abdominal CT 45% (37/85) and 35% (29/85), respectively). Recurrence rates increased with SBNEN size (p = 0.012; e.g., of SBNEN diagnosed by endoscopy, 18% of SBNEN measuring 0.6 ± 0.3 cm recurred vs. 75% measuring 3.7 ± 1.0 cm). Rates of disease-free survival, and the incidence of local and liver metastases were decreased when tumors were first identified by CTE rather than other CT/MR imaging modalities (p = 0.0034, 0.0475, and 0.0032, respectively). CONCLUSION: There has been a dramatic increase in SBNENs detected by CTE and endoscopy over the last 20 years. SBNEN's detected by CTE and small tumors detected at endoscopy have longer disease-free survival after surgical resection.


Asunto(s)
Neoplasias Intestinales/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Tumores Neuroendocrinos/diagnóstico por imagen , Anciano , Supervivencia sin Enfermedad , Endoscopía Gastrointestinal , Femenino , Humanos , Neoplasias Intestinales/patología , Intestino Delgado/patología , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA