Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Clin Anat ; 33(4): 552-557, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-31301242

RESUMEN

Cerclage wiring of the humeral diaphysis entails particular danger to the radial nerve and the deep brachial artery. We sought to delineate safe zones for minimally invasive cerclage wiring of the humeral diaphysis, specifically in relation to the radial nerve and accompanying vasculature. Cerclage wires were percutaneously inserted into three groups of fresh-frozen cadaveric humeri. Group 1-proximal midshaft humerus at 30% of humeral height (n = 4); Group 2-midshaft spiral groove at 45% of humeral height (n = 4); and Group 3-distal midshaft humerus at 60% of humeral height (n = 4). Subsequently, an extensive surgical exploration of the arteries and nerves around the humerus was performed, noting any disturbance to the vessels or nerves and measuring the distance from the cerclage wire to the radial nerve. Neurovascular structures were injured in 75% of specimens when the cerclage wire was inserted at the level of the spiral groove. Both posterior structures, e.g. the radial nerve and the deep brachial artery, and medial structures, e.g., the median nerve and brachial artery, were incarcerated. Application of the cerclage at 30% or 60% of humeral height did not cause neurovascular injury. Minimally invasive application of the cerclage wire at the spiral groove, which is at 45% of humeral height, is likely to cause injury to neurovascular structures. Application of the cerclage at the proximal or distal midshaft humeral areas is associated with less risk of such injury. Clin. Anat. 33:552-557, 2020. © 2019 Wiley Periodicals, Inc.


Asunto(s)
Hilos Ortopédicos , Diáfisis/cirugía , Fijación Interna de Fracturas/métodos , Fracturas del Húmero/cirugía , Cadáver , Diáfisis/irrigación sanguínea , Diáfisis/inervación , Humanos , Procedimientos Quirúrgicos Mínimamente Invasivos , Traumatismos de los Nervios Periféricos/prevención & control , Lesiones del Sistema Vascular/prevención & control
2.
Curr Pain Headache Rep ; 22(9): 58, 2018 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-29987515

RESUMEN

PURPOSE OF REVIEW: This review discusses both obvious and hidden barriers in trauma patient access to pain management specialists and provides some suggestions focusing on outcome optimization in the perioperative period. RECENT FINDINGS: Orthopedic trauma surgeons strive to provide patients the best possible perioperative pain management, while balancing against potential risks of opioid abuse and addiction. Surgeons often find they are ill-prepared to effectively manage postoperative pain in patients returning several months following trauma surgery, many times still dependent on opioids for pain control. Some individuals from this trauma patient population may also require the care of pain management specialists and/or consultation with drug addiction specialists. As the US opioid epidemic continues to worsen, orthopedic trauma surgeons can find it difficult to obtain access to pain management specialists for those patients requiring complex pain medication management and substance abuse counseling. The current state of perioperative pain management for orthopedic trauma patients remains troubling due to reliance on only opioid analgesics, society-associated risks of opioid medication addiction, an "underground" prescription drug marketplace, and an uncertain legal atmosphere related to opioid pain medication management that can deter pain management physicians from accepting narcotic-addicted patients and discourage future physicians from pursuing advanced training in the specialty of pain management. Additionally, barriers continue to exist among Medicaid patients that deter this patient population from access to pain medicine subspecialty care, diminishing medication management reimbursement rates make it increasingly difficult for trauma patients to receive proper opioid analgesic pain medication management, and a lack of proper opioid analgesic medication management training among PCPs and orthopedic trauma surgeons further contributes to an environment ill-prepared to provide effective perioperative pain management for orthopedic trauma patients.


Asunto(s)
Analgésicos Opioides/uso terapéutico , Trastornos Relacionados con Opioides/tratamiento farmacológico , Manejo del Dolor , Dolor Postoperatorio/tratamiento farmacológico , Rol del Médico , Analgésicos Opioides/administración & dosificación , Animales , Prescripciones de Medicamentos , Humanos
3.
Skeletal Radiol ; 46(6): 723-730, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28238017

RESUMEN

Anterior hip dislocations are rare orthopedic emergencies resulting from high-energy trauma and have unique imaging characteristics on radiography, computed tomography (CT), and magnetic resonance imaging (MRI). Imaging findings on CT and MRI allow for the prompt recognition and classification of anterior hip dislocations, which guides patient management and reduces complications. The purpose of this article is to review imaging findings of anterior hip dislocations, specifically focusing on CT and MRI.


Asunto(s)
Luxación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
5.
Lipids Health Dis ; 14: 53, 2015 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-26048287

RESUMEN

Circulating levels of triacylglycerol (TG) is a recognized risk factor for developing cardiovascular disease, a leading cause of death worldwide. The Institute of Medicine and the American Heart Association both recommend the consumption of n-3 polyunsaturated fatty acids (PUFA), specifically eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA), to reduce serum TG in hyperlipidemic individuals. Additionally, a number of systematic reviews have shown that individuals with any degree of dyslipidemia, elevated serum TG and/or cholesterol, may benefit from a 20-30% reduction in serum TG after consuming n-3 PUFA derived from marine sources. Given that individuals with serum lipid levels ranging from healthy to borderline dyslipidemic constitute a large portion of the population, the focus of this review was to assess the potential for n-3 PUFA consumption to reduce serum TG in such individuals. A total of 1341 studies were retrieved and 38 clinical intervention studies, assessing 2270 individuals, were identified for inclusion in the current review. In summary, a 9-26% reduction in circulating TG was demonstrated in studies where ≥ 4 g/day of n-3 PUFA were consumed from either marine or EPA/DHA-enriched food sources, while a 4-51% reduction was found in studies where 1-5 g/day of EPA and/or DHA was consumed through supplements. Overall, this review summarizes the current evidence with regards to the beneficial effect of n-3 PUFA on circulating TG levels in normolipidemic to borderline hyperlipidemic, otherwise healthy, individuals. Thus demonstrating that n-3 PUFA may play an important role in the maintenance of cardiovascular health and disease prevention.


Asunto(s)
Ácidos Grasos Omega-3/uso terapéutico , Hiperlipidemias/tratamiento farmacológico , Triglicéridos/sangre , Adulto , Anciano , Dieta , Suplementos Dietéticos , Femenino , Humanos , Hiperlipidemias/sangre , Masculino , Persona de Mediana Edad
6.
Conn Med ; 79(8): 453-9, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26506676

RESUMEN

The lack of a mandatory motorcycle helmet law leads to increased injury severity and increased health care costs. This study presents a financial model to estimate how the lack of a mandatory helmet law impacts the cost of health care in the state of Connecticut. The average cost to treat a helmeted rider and a nonhelmeted rider was $3,112 and $5,746 respectively (cost adjusted for year 2014). The total hospital treatment cost in the state of Connecticut from 2003 through 2012 was $73,106,197, with $51,508,804 attributed to nonhelmeted riders and $21,597,393 attributed to helmeted riders. The total Medicaid cost to the state of Connecticut for treating nonhelmeted patients was $18,277,317. This model demonstrates that the lack of a mandatory helmet law increases overall health care costs to the state of Connecticut, and provides a framework by which hospital costs can be reduced to contribute to the economic stability of health care economics in the state.


Asunto(s)
Accidentes de Tránsito/economía , Dispositivos de Protección de la Cabeza/economía , Dispositivos de Protección de la Cabeza/estadística & datos numéricos , Costos de la Atención en Salud/estadística & datos numéricos , Motocicletas/economía , Motocicletas/legislación & jurisprudencia , Connecticut , Costos y Análisis de Costo , Humanos , Modelos Económicos , Sistema de Registros
7.
J Psycholinguist Res ; 44(6): 701-14, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25134668

RESUMEN

The present study aims to investigate Chinese English learners' ability to use communication strategies (CSs). The subjects are put in a relatively real English referential communication setting and the analyses of the research data show that Chinese English learners, when encountering problems in foreign language (FL) communication, are characterized by the frequent use of substitution, approximation, circumlocution, literal translation, exemplification, word-coinage, repetition, and the infrequent use of cultural-knowledge and paralinguistic CSs. The rare use of paralinguistic strategies is found to be typical of Chinese English learners. The high frequency of literal translation, one first language (L1)-based strategy in our study sample, suggests that FL learners' use of L1-based CSs may depend more upon the developmental stage of their target language than the typology distance between L1 and the target language. The frequency of repetition reveals one fact that the Chinese English learners lack variety and flexibility in their use of CSs. Based on these findings, it was indicated that learners' use of CSs is influenced by a variety of factors, among which the development stage of their interlanguage and their cultural background are identified as two important factors. Some implications are finally suggested for the English foreign language teaching practice in China.


Asunto(s)
Comunicación , Aprendizaje , Multilingüismo , Adulto , China , Humanos , Enseñanza/métodos , Adulto Joven
8.
Lipids Health Dis ; 13: 96, 2014 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-24916956

RESUMEN

BACKGROUND: Breast cancer is attributable to modifiable risk factors including the intake of dietary n-3 polyunsaturated fatty acids (PUFA). A key piece of evidence, yet to be addressed, that would demonstrate a causal relationship between n-3 PUFA and breast cancer, is a dose-dependent effect of n-3 PUFA on tumour outcomes. Thus, the objective of the present study was to determine whether n-3 PUFA reduces mammary gland tumor outcomes in a dose-dependent manner in female MMTV-neu(ndl)-YD5 transgenic mice, an aggressive model of human breast cancer. METHODS: Harems were provided one of three experimental diets comprised of 0, 3 or 9% (w/w) menhaden fish oil containing n-3 PUFA. Female offspring were weaned onto the same parental diet and maintained on their respective diet for 20 weeks. Tumour onset, size and multiplicity were measured throughout the study. Fatty acid composition of mammary gland and tumours were determined by gas-liquid chromatography. RESULTS: Tumour size was significantly (p < 0.05) reduced in a dose-dependent manner. n-3 PUFA were also incorporated in a dose-dependent manner; differential incorporation was observed for eicosapentaenoic and docosapentaenoic acids into mammary gland tissue, while docosahexaenoic acid was preferentially incorporated into tumours. CONCLUSION: Overall, the present study provides fundamental knowledge about the dose-dependent effect of n-3 PUFA on tumour outcomes in a pre-clinical model and also sheds light on the differential role of individual n-3 PUFA on tumour outcomes.


Asunto(s)
Ácidos Grasos Omega-3/uso terapéutico , Neoplasias Mamarias Animales/tratamiento farmacológico , Animales , Modelos Animales de Enfermedad , Ácidos Grasos Insaturados/uso terapéutico , Femenino , Neoplasias Mamarias Animales/metabolismo , Ratones , Ratones Transgénicos
9.
3D Print Med ; 10(1): 7, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38427157

RESUMEN

BACKGROUND: The extended trochanteric osteotomy (ETO) is a surgical technique utilized to expose the intramedullary canal of the proximal femur, protect the soft tissues and promote reliable healing. However, imprecise execution of the osteotomy can lead to fracture, soft tissue injury, non-union, and unnecessary morbidity. We developed a technique to create patient specific, 3D-printed cutting guides to aid in accurate positioning of the ETO and improve osteotomy quality and outcomes. METHODS: Patient specific cutting guides were created based on CT scans using Synopysis Simpleware ScanIP and Solidworks. Custom 3D printed cutting guides were tested on synthetic femurs with foam cortical shells and on cadaveric femurs. To confirm accuracy of the osteotomies, dimensions of the performed osteotomies were compared to the virtually planned osteotomies. RESULTS: Use of the patient specific ETO cutting guides resulted in successful osteotomies, exposing the femoral canal and the femoral stem both in synthetic sawbone and cadaveric testing. In cadaveric testing, the guides allowed for osteotomies without fracture and cuts made using the guide were accurate within 6 percent error from the virtually planned osteotomy. CONCLUSION: The 3D-printed patient specific cutting guides used to aid in ETOs proved to be accurate. Through the iterative development of cutting guides, we found that a simple design was key to a reliable and accurate guide. While future clinical trials in human subjects are needed, we believe our custom 3D printed cutting guide design to be effective at aiding in performing ETOs for revision total hip arthroplasty surgeries.

10.
Cureus ; 16(2): e55136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38558586

RESUMEN

INTRODUCTION: The selection of the most optimal fixation method for fractures of the distal femur, whether intramedullary nail (NL), lateral locking plate (PL), or nail/plate (NP) is not always clear. This study retrospectively evaluates surgical patients with distal femur fractures and introduces a pilot study using cluster analysis to identify the most optimal fracture fixation method for a given fracture type. METHODS: This is a retrospective cohort study of patients 18 years and older with an isolated distal femur fracture who presented to our Level-1 trauma center between January 1, 2012, and December 31, 2022, and obtained NL, PL, or NP implants. Patients with polytrauma and those without at least six months of follow-up were excluded. A chart review was used to obtain demographics, fracture classification, fixation method, and postoperative complications. A cluster analysis was performed. The following factors were used to determine a successful outcome: ambulatory status pre-injury and 6-12 months postoperatively, infection, non-union, mortality, and implant failure. RESULTS: A total of 169 patients met inclusion criteria. No statistically significant association between the fracture classification and fixation type with overall outcome was found. However, patients treated with an NP (n = 14) had a success rate of 92.9% vs only a 68.1% success rate in those treated with a PL (n = 116) (p = 0.106). The most notable findings in the cluster analysis (15 total clusters) included transverse extraarticular fractures demonstrating 100% success if treated with NP (n = 6), 50% success with NL (n=2), and 78.57% success with PL fixation (n=14). NP constructs in complete articular fractures demonstrated success in 100% of patients (n = 5), whereas 77.78% of patients treated with NL (n = 9) and 61.36% of those treated with PL (n = 44). CONCLUSIONS: Plate fixation was the predominant fixation method used for distal third femur fractures regardless of fracture classification. However, NP constructs trended towards improved success rates, especially in complete intraarticular and transverse extraarticular fractures, suggesting the potential benefit of additional fixation with these fractures. Cluster analysis provided a heuristic way of creating patient profiles in patients with distal third femur fractures. However, a larger cohort study is needed to corroborate these findings to ultimately develop a clinical decision-making tool that also accounts for patient specific characteristics.

11.
Cureus ; 15(5): e39503, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37366446

RESUMEN

Pain control after total hip arthroplasty is associated with patient satisfaction, early discharge, and improved surgical outcomes. Two commonly utilized opioid-reducing analgesic modalities are periarticular injection (PAI) by surgeons and motor-sparing peripheral nerve block (PNB) by anesthesiologists. We present a case contrasting PAI and PNB in a single patient undergoing bilateral total hip arthroplasty. For the left hip, the patient received preoperative transmuscular quadratus lumborum, femoral nerve, and lateral femoral cutaneous nerve blocks using a combination of low-concentration local anesthetic and glucocorticoids. For the right hip, the patient received an intraoperative PAI with liposomal bupivacaine. The patient's pain scores and recovery were evaluated for three months postoperatively. The patient's pain scores on postoperative day (POD) zero to five were consistently lower in the left hip than in the right hip. For this patient undergoing bilateral hip replacement, preoperative PNBs were superior to PAI for postoperative pain control.

12.
J Vasc Surg Cases Innov Tech ; 9(3): 101218, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37799843

RESUMEN

Supracondylar humerus fractures are common in children and can compromise the brachial artery in 5% to 15% of cases. A 4-year-old boy with a left supracondylar fracture developed upper extremity ischemia after pinning of the fracture. Computed tomography angiography revealed cutoff of flow in the brachial artery. Intraoperatively, he was found to have bands tethering the artery into the fracture, obstructing the blood flow. The orthopedic pins were removed, and the constraining bands were lysed to free the artery, with reconstitution of flow confirmed by intraoperative angiography. The fracture was reduced and stabilized, and the patient recovered well with normal arterial flow on follow-up ultrasound after 3 months.

13.
Foot Ankle Int ; 44(7): 665-674, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37226736

RESUMEN

BACKGROUND: Ankle, hindfoot, and midfoot arthrodesis surgeries are standard procedures performed in orthopaedics to treat pain and functional disabilities. Although fusions can effectively improve pain and quality of life, nonunions remain a significant concern for surgeons. With the increased availability of computed tomography (CT), more surgeons rely on this modality for increased accuracy in determining whether a fusion was successful. The objective of this study was to report the rates of CT-confirmed fusion following ankle, hindfoot, or midfoot arthrodesis. METHODS: A systematic review was performed using EMBASE, Medline, and Cochrane central register from January 2000 to March 2020. Inclusion criteria included studies with adults (<18 years) that received 1 or multiple fusions of the ankle, hindfoot, or midfoot. At least 75% of the study cohort must have been evaluated by CT postoperatively. Basic information was collected, including journal, author, year published, and level of evidence. Other specific information was collected, including patient risk factors, fusion site, surgical technique and fixation, adjuncts, union rates, criteria for successful fusion (%), and time of CT. Once data were collected, a descriptive and comparative analysis was performed. RESULTS: Included studies (26, n = 1300) had an overall CT-confirmed fusion rate of 78.7% (69.6-87.7). Individual joints had an overall fusion rate of 83.0% (73-92.9). The highest rate of union was in the talonavicular joint (TNJ). CONCLUSION: These values are lower than previous studies, which found the same procedures to have greater than 90% fusion rates. With these updated figures, as confirmed by CT, surgeons will have better information for clinical decision making and when having informed consent conversations.


Asunto(s)
Tobillo , Calidad de Vida , Adulto , Humanos , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía , Tomografía Computarizada por Rayos X , Artrodesis/métodos , Dolor/etiología , Estudios Retrospectivos , Resultado del Tratamiento
14.
Clin Biomech (Bristol, Avon) ; 110: 106129, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37871506

RESUMEN

BACKGROUND: The locking plate is a common device to treat distal femur fractures. Healing is affected by construct stiffness, thus many surgeon-controlled variables such as working length have been examined for their effects on strain at the fracture. No convenient analytical model which aids surgeons in determining working length has yet been described. We propose an analytical model and compare it to finite element analysis and cadaveric biomechanical testing. METHODS: First, an analytical model based on a cantilever beam equation was derived. Next, a finite element model was developed based on a CT scan of a "fresh-frozen" cadaveric femur. Third, biomechanical testing in single-leg stance loading was performed on the cadaver. In all methods, strain at the fracture was recorded. An ANCOVA test was conducted to compare the strains. FINDINGS: In all models, as the working length increased so did strain. For strain at the fracture, the shortest working length (35 mm) had a strain of 8% in the analytical model, 9% in the finite element model, and 7% for the cadaver. The longest working length (140 mm) demonstrated strain of 15% in the analytical model, and the finite element and biomechanical tests both demonstrated strain of 14%. INTERPRETATION: The strain predicted by the analytical model was consistent with the strain observed in both the finite element and biomechanical models. As demonstrated in existing literature, increasing the working length increases strain at the fracture site. Additional work is required to refine and establish validity and reliability of the analytical model.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Humanos , Reproducibilidad de los Resultados , Tornillos Óseos , Fenómenos Biomecánicos , Placas Óseas , Fracturas del Fémur/cirugía , Análisis de Elementos Finitos , Cadáver
15.
16.
Yale J Biol Med ; 85(1): 119-25, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22461750

RESUMEN

Partial weight-bearing instructions are commonly given to orthopaedic patients and are an important part of post-injury and/or post-operative care. However, the ability of patients to comply with these instructions is poorly defined. Training methods for instructing these patients vary widely among institutions. Traditional methods of training include verbal instruction and use of a bathroom scale. Recent technological advances have created biofeedback devices capable of offering feedback to partial weight-bearing patients. Biofeedback devices have shown great promise in training patients to better comply with partial weight-bearing instructions. This review examines the background and significance of partial weight bearing and offers insights into current advances in training methods for partial weight-bearing patients.


Asunto(s)
Ortopedia/educación , Ortopedia/tendencias , Cooperación del Paciente , Humanos , Soporte de Peso/fisiología
17.
Arthroplast Today ; 15: 153-158, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35586609

RESUMEN

Imageless computer-assisted navigation (CAN) excels in the post-traumatic arthritis and complex revision case setting when altered anatomy and landmarks are inaccurate references for cup positioning. We describe the case of an adult male patient who suffered an acetabular fracture which was treated nonoperatively. He subsequently developed post-traumatic arthritis and underwent an anterior approach total hip arthroplasty 25 years later. Postoperatively, he developed recurrent hip instability due to malpositioned components. We describe the use of imageless CAN during revision total hip arthroplasty to correct malpositioned components, with 3-year follow-up without dislocation. In these complex cases, CAN reduces the risk of component malpositioning and joint instability.

18.
Geriatr Orthop Surg Rehabil ; 13: 21514593221135117, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36393901

RESUMEN

Introduction: Hip fractures cause significant morbidity and mortality for geriatric patients, and incidence is increasing as the population ages. Following a primary hip fracture, up to 20% may suffer a contralateral hip fracture within 5 years despite fracture risk reduction measures, including fall prevention and osteoporosis pharmacologic treatment. The aim of this study is to assess whether insertion of the Femoral Neck System (Depuy Synthes, West Chester, PA) into the contralateral proximal femur may strengthen the bone and decrease the incidence of contralateral hip fractures. Materials and Methods: ScanIP, an image processing software was used to produce 3-dimensional models of a cadaver femur with the implanted device. Models were meshed and exported to Abaqus for finite element analysis to evaluate the device's ability to reduce stress in the proximal femur. Results were analyzed for element-wise volume and von-Mises stresses. Results: The implant reduced peak stress and bone failure at all levels of bone quality. Specifically in osteoporotic bone, the implant decreased peak stress by 27%, proximal femur trabecular bone failure by 5% and cortical bone failure by 100% in the femoral neck. Conclusions: Our results from computer generated finite element analyses indicate that the Femoral Neck System may strengthen an osteoporotic proximal femur in the event of a lateral fall. Further investigation with expanded finite element analysis and cadaveric biomechanical studies are needed to validate these results.

19.
Geriatr Orthop Surg Rehabil ; 13: 21514593221141376, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36533207

RESUMEN

Introduction: Geriatric patients who suffer femoral neck fractures have high morbidity and mortality. Prophylactic fixation of the femoral neck is a potential avenue to reduce the incidence of femoral neck fractures. We studied 3 different implants traditionally used to stabilize the femoral neck: 6.5 mm cannulated screws (CANN), the femoral neck system (FNS) (Depuy Synthes), and the dynamic hip screw (DHS) (Depuy Synthes). Materials and Methods: Five osteoporotic Sawbone femurs were used for each model and a control group. Two scenarios were investigated: single leg stance to measure construct stiffness and lateral impact to measure construct stiffness, energy to fracture, and qualitative examination of fracture patterns. Stiffness for each femur and energy to fracture for the lateral impact scenario were calculated and compared between groups using one-way ANOVA. Results: DHS showed significantly higher stiffness than the other 2 implants and the control in single leg stance. In the lateral impact scenario, the DHS and CANN were significantly stiffer FNS and the control. Femurs implanted with CANN tended to fracture at the greater trochanter while FNS fractured in a transverse subtrochanteric pattern, and DHS fractured obliquely in the subtrochanteric region. Discussion: FNS and DHS experienced fracture patterns less amenable to surgical correction. CANN and DHS proved better able to resist external forces in the lateral fall scenario. CANN also proved better able to resist external forces in the single leg stance scenario and experienced a more amenable fracture pattern in the lateral fall scenario. Conclusions: FNS was less able to resist external forces compared with the other implants. This work informs the potential implications between the choice of implants that, although historically have not been used prophylactically, may be considered in the future for prophylactic stabilization of the femoral neck. Cadaveric study and clinical trials are recommended for further study.

20.
3D Print Med ; 8(1): 19, 2022 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-35781846

RESUMEN

BACKGROUND: The goal of stabilization of the femoral neck is to limit morbidity and mortality from fracture. Of three potential methods of fixation, (three percutaneous screws, the Synthes Femoral Neck System, and a dynamic hip screw), each requires guide wire positioning of the implant(s) in the femoral neck and head. Consistent and accurate positioning of these systems is paramount to reduce surgical times, stabilize fractures effectively, and reduce complications. To help expedite surgery and achieve ideal implant positioning in the geriatric population, we have developed and validated a surgical planning methodology using 3D modelling and printing technology. METHODS: Using image processing software, 3D surgical models were generated placing guide wires in a virtual model of an osteoporotic proximal femur sawbone. Three unique drill guides were created to achieve the optimal position for implant placement for each of the three different implant systems, and the guides were 3D printed. Subsequently, a trauma fellowship trained orthopedic surgeon used the 3D printed guides to position 2.8 mm diameter drill bit tipped guide wires into five osteoporotic sawbones for each of the three systems (fifteen sawbones total). Computed Tomography (CT) scans were then taken of each of the sawbones with the implants in place. 3D model renderings of the CT scans were created using image processing techniques and the displacement and angular deviations at guide wire entry to the optimal sawbone model were measured. RESULTS: Across all three percutaneous screw guide wires, the average displacement was 3.19 ± 0.12 mm and the average angular deviation was 4.10 ± 0.17o. The Femoral Neck System guide wires had an average displacement of 1.59 ± 0.18 mm and average angular deviation of 2.81 ± 0.64o. The Dynamic Hip Screw had an average displacement of 1.03 ± 0.19 mm and average angular deviation of 2.59 ± 0.39o. CONCLUSION: The use of custom 3D printed drill guides to assist with the positioning of guide wires proved to be accurate for each of the three types of surgical strategies. Guides which are used to place more than 1 guide wire may have lower positional accuracy, as the guide may shift during multiple wire insertions. We believe that personalized point of care drill guides provide an accurate intraoperative method for positioning implants into the femoral neck.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA