Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Chemosphere ; 349: 140893, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38072205

RESUMEN

In regulatory environmental monitoring programs, only a very small fraction of the vast number of per- and polyfluoroalkyl substances (PFAS) are investigated by target analysis. Therefore, non-target analysis (NTA) studies are increasingly conducted to detect unknown or unnoticed PFAS. These studies are often based on a few grab samples. Thus, discontinuously emitted PFAS from industrial batch processes might be easily overlooked. To address this deficiency and obtain in-depth information on the occurrence and temporal trend of PFAS in surface water impacted by treated industrial waste water, a comprehensive target and NTA study was implemented for 29 months. Elevated PFAS concentrations with up to 10.8 µg L-1 were detected in the river water by target analysis. In addition to PFAS target analysis, the water samples were analyzed by liquid chromatography-high-resolution tandem mass spectrometry (LC-HRMS/MS). Data processing strategies and various filtering steps were applied to prioritize PFAS. Substances were identified by comparing data to available internal and external PFAS suspect lists, a fragment ion and neutral loss list, and spectral libraries. Several compounds were unequivocally identified based on reference standards. Fifty-five PFAS were (tentatively) identified using NTA. Of those, 43 could be assigned to 13 different homologous series. Partly fluorinated short-chain carboxylic acids (H-PFCA) and sulfonic acids (H-PFSA) were predominantly found in addition to perfluoroalkyl carboxylic acids (PFCA) and the alkyl ether carboxylic acid DONA. To the best of our knowledge, 12 PFAS were reported in surface water for the first time. Signal intensities of individual PFAS and signal ratios varied widely over time, which may indicate batch operations leading to discontinuous emission. Results and insights from this screening approach on PFAS can be used to optimize forthcoming surface water monitoring programs by including newly identified PFAS and selecting appropriate sampling intervals.


Asunto(s)
Fluorocarburos , Contaminantes Químicos del Agua , Fluorocarburos/análisis , Contaminantes Químicos del Agua/análisis , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Ácidos Carboxílicos/análisis
2.
Rapid Commun Mass Spectrom ; 13(24): 2456-68, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10589094

RESUMEN

Partially oxidized derivatives of polycyclic aromatic hydrocarbons (PAHs) are known to be important environmental pollutants. For the identification of these substances in complex mixtures, e.g. atmospheric aerosol samples, liquid chromatography/mass spectrometry with atmospheric pressure chemical ionization (LC/APCI-MS) has been found to be a suitable analytical technique. In this study 31 derivatives of mono- and polycyclic aromatic hydrocarbons with up to five condensed aromatic rings carrying different functional groups (carboxyl, dicarboxylic anhydride, lactone, hydroxyl, and carbonyl) were characterized by LC/APCI-MS. Each substance was measured in positive and negative ion detection mode at four different fragmentor voltages (90 to 190 V). For the first time, the results show that characteristic and well-interpretable fragmentation patterns can be obtained for these classes of compounds by in-source collision-induced dissociation in a single quadrupole LC/APCI-MS system. For each class of compounds typical spectral features and optimum measurement conditions are reported, and fragmentation pathways are proposed. The study demonstrates the applicability of LC/APCI-MS for the determination of most of the investigated compounds at trace levels, and it provides a database for the identification of unknown partially oxidized aromatic hydrocarbons. Copyright 1999 John Wiley & Sons, Ltd.

3.
J Chromatogr A ; 855(2): 501-14, 1999 Sep 10.
Artículo en Inglés | MEDLINE | ID: mdl-10519088

RESUMEN

The environmental relevance of oxidized degradation products of polycyclic aromatic hydrocarbons (PAHs) increases due to enhanced combustion of organic matter and fossil fuels. For PAHs consisting of more than three condensed aromatic rings, soot aerosols are the main carrier, on the surface of which they can react with trace gases like ozone. In this study the clean-up procedure and analysis of ozonized benzo[a]pyrene (B[a]P) was optimized. B[a]P and its degradation products were preseparated into three fractions. Different reversed-phase materials were evaluated for high-performance liquid chromatographic separation. Among these, a phenyl-modified silica material proved best-suited and the chromatographic separation was optimized on this material. For the detection of separated degradation products, liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) was used. With this method, 29 components could be characterized. Besides the three known main degradation products (B[a]P-1,6-dione, B[a]P-3,6-dione, B[a]P-6,12-dione, B[a]P-4,5-dione and 4-oxa-benzo[d,e,f]chrysene-5-one (B[def]C-lactone), were identified for the first time with the help of reference substances. B[def]C-lactone is known as a substance with a mutagenic potential similar to B[a]P. Several other compounds could be tentatively identified.


Asunto(s)
Benzo(a)pireno/aislamiento & purificación , Espectrometría de Masas/métodos , Presión Atmosférica
4.
J Virol Methods ; 173(1): 49-59, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21237207

RESUMEN

Avian influenza viruses (AIVs) of the H5 and H7 subtypes can cause substantial economic losses in the poultry industry and are a potential threat to public health. Serosurveillance of poultry populations is an important monitoring tool and can also be used for control of vaccination campaigns. The purpose of this study was to develop broadly reactive, yet subtype-specific competitive ELISAs (cELISAs) for the specific detection of antibodies to the notifiable AIV subtypes H5 and H7 as an alternative to the gold standard haemagglutination inhibition assay (HI). Broadly reacting monoclonal competitor antibodies (mAbs) and genetically engineered subtype H5 or H7 haemagglutinin antigen, expressed and in vivo biotinylated in insect cells, were used to develop the cELISAs. Sera from galliform species and water fowl (n=793) were used to evaluate the performance characteristics of the cELISAs. For the H5 specific cELISA, 98.1% test sensitivity and 91.5% test specificity (97.7% and 90.2% for galliforms; 98.9% and 92.6% for waterfowl), and for the H7 cELISA 97.3% sensitivity and 91.8% specificity (95.3% and 98.9% for galliforms; 100% and 82.7% for waterfowl) were reached when compared to HI. The use of competitor mAbs with broad spectrum reactivity within an AIV haemagglutinin subtype allowed for homogenous detection with high sensitivity of subtype-specific antibodies induced by antigenically widely distinct isolates including antigenic drift variants. However, a trade-off regarding sensitivity versus nonspecific detection of interfering antibodies induced by phylo- and antigenically closely related subtypes, e.g., H5 versus H2 and H7 versus H15, must be considered. The observed intersubtype antibody cross-reactivity remains a disturbance variable in AIV subtype-specific serodiagnosis which negatively affects specificity.


Asunto(s)
Virus de la Influenza A/aislamiento & purificación , Gripe Aviar/diagnóstico , Gripe Aviar/virología , Virología/métodos , Animales , Aves , Ensayo de Inmunoadsorción Enzimática/métodos , Glicoproteínas Hemaglutininas del Virus de la Influenza/inmunología , Virus de la Influenza A/inmunología , Sensibilidad y Especificidad
5.
Anal Bioanal Chem ; 381(3): 647-55, 2005 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-15703914

RESUMEN

The enzymatic peptide phosphorylation by cAMP-dependent protein kinase A (PKA) was optimized and monitored by means of electrospray ionization mass spectrometry (ESI-MS). The direct detection of phosphorylated peptides by MS renders labeling unnecessary, reduces time and labor, due to less initial sample pretreatment. In this study the phosphorylation of the peptide malantide by PKA was performed in batch and reaction compounds were detected by ESI-MS after the incubation time. The subsequent product quantitation was accomplished by using one-point normalization. Applying this set-up, optimum solvent conditions (such as salt and modifier content), concentrations of essential reaction compounds (such as cAMP, Mg2+ and ATP), and the influence of reaction properties (such as pH and reaction time) were determined. The reaction milieu has to be suitable for both, the enzymatic reaction and the mass spectrometric detection. We found that the modifier content and the pH value had to be changed after the enzymatic reaction occurred. Through the addition of methanol and acetic acid, the reaction stopped immediately and a more sensitive mass spectrometric detection could be obtained simultaneously. Furthermore, an inhibitor study was performed, testing the inhibition potency of three protein kinase A inhibitors (PKIs). IC50 values were determined and used to calculate the Ki values, that were 7.4, 19.0 and 340.0 nmol/L for PKI(6-22)amide, PKI(5-24)amide, and PKI(14-24)amide, respectively. These data vary between factor 4.4 (for PKI(6-22)amide) and 8.3 (for PKI(5-24)amide) compared to the Ki values described in literature. However, the Ki values are in good agreement with the data mainly obtained by fluorescence- or radioactivity-based methods. Nevertheless, our results indicate that ESI-MS is a realistic alternative to radioactivity and fluorescence detection in determining enzymatic activity. Furthermore we were able to illustrate its high potential as a quantitative detection method.


Asunto(s)
Proteínas Quinasas Dependientes de AMP Cíclico/metabolismo , Oligopéptidos/química , Oligopéptidos/metabolismo , Adenosina Trifosfato/metabolismo , Animales , Tampones (Química) , Bovinos , AMP Cíclico/metabolismo , Cinética , Miocardio/enzimología , Fosforilación , Espectrometría de Masa por Ionización de Electrospray
6.
Anal Chem ; 73(7): 1634-45, 2001 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-11321321

RESUMEN

A new liquid chromatographic method for the efficient separation of aromatic compounds having a wide range of sizes, molecular structures, and polarities has been developed. Based on a phenyl-modified silica reversed stationary phase and a methanol-water solvent gradient, it allows the separation of mono- and polycyclic aromatic hydrocarbons (PAHs) having up to five condensed aromatic rings and partially oxidized derivatives within a single chromatographic run of 40-min duration. The applicability of the method is demonstrated using 81 reference substances (PAHs, phenols, quinones, acids, lactones, esters, etc.) and real samples of environmental, medical, and technical relevance (ozonized PAHs, lake water, human urine, diesel exhaust condensates). The retention times of the investigated aromatics exhibit a regular increase with molecular mass and a systematic decrease with increasing number and polarity of functional groups. In case of intramolecular hydrogen bonding, a positive shift of retention time provides additional structural information. The combination of chromatographic retention time with the molecular mass and structural information from mass spectrometric detection allows the tentative identification of unknown aromatic analytes at trace levels, even without specific reference substances. With atmospheric pressure chemical ionization (APCI), low detection limits and highly informative fragmentation patterns can be obtained by in-source collision-induced fragmentation in a single-quadrupole LC-APCI-MS system as applied in this study, and multidimensional MS experiments are expected to further enhance the potential of the presented method.


Asunto(s)
Cromatografía Liquida/métodos , Hidrocarburos Aromáticos/análisis , Presión Atmosférica , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Masculino , Oxidación-Reducción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA