Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
2.
Ultrasound Obstet Gynecol ; 41(1): 40-6, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23023941

RESUMEN

OBJECTIVES: To evaluate the feasibility of completing in one session a second-trimester ultrasound scan in obese pregnant women, to compare the quality of images obtained with those of non-obese women and to analyze factors that can improve the completion rate. METHODS: This prospective study, from 2009 to 2011, included all obese pregnant women (prepregnancy body mass index (BMI) > 30 kg/m2) who had an ultrasound examination at 20-24 weeks in our department, and a control group of pregnant women with normal BMI (20-24.9 kg/m2) who had the same examination. A single operator reviewed the standardized ultrasound images (three biometric and six to assess key anatomical features) required under French guidelines, to assess their presence, evaluate the quality of all images and score the quality of the six anatomical images. Each image was assessed according to between four and six criteria, each worth one point. We sought excellent quality, defined as the frequency of maximum points for a given image type. The factors associated with completing the scan in one session were evaluated with multivariate logistic regression. RESULTS: The obese group included 223 women and the control group 60; a complete scan in one session was achieved in 70.4% and 81.7% of these, respectively (P = 0.08). The completion rate for each image type was at least 95% in the control group and 90% in the obese group, except for diaphragm and right outflow tract images. Significant factors associated with completing the scan in the multivariate model were: having 10 additional minutes for the scan (P = 0.03), moving the fetus so that the back was in posterior or lateral position (P = 0.01), more experienced sonographer (P = 0.03) and thinner maternal abdominal wall thickness (P = 0.01). Overall, the excellence rate varied from 35% to 92% in the normal BMI group and from 18% to 58% in the obese group, and was significantly lower in the latter for all images except abdominal circumference (P = 0.26) and spine (P = 0.06). Anatomical quality scores were also significantly lower in the obese group (22.3 vs. 27.2; P = 0.001). CONCLUSION: Although ultrasound scans of obese pregnant women are feasible, image quality and global anatomical scores are significantly lower among obese than normal-weight women. However, certain simple improvements may increase fetal visualization.


Asunto(s)
Índice de Masa Corporal , Feto/anatomía & histología , Obesidad/diagnóstico por imagen , Complicaciones del Embarazo/diagnóstico por imagen , Ultrasonografía Prenatal/normas , Adulto , Estudios de Casos y Controles , Estudios de Factibilidad , Femenino , Edad Gestacional , Humanos , Aumento de la Imagen , Modelos Logísticos , Obesidad/complicaciones , Embarazo , Segundo Trimestre del Embarazo , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo , Adulto Joven
5.
Gynecol Obstet Fertil Senol ; 50(9): 624-637, 2022 09.
Artículo en Francés | MEDLINE | ID: mdl-35817342

RESUMEN

Antenatal ear examination is an integral part of the thorough examination of the fetal face. The discovery of an anomaly, whether it is made by chance or during a complementary in-depth examination, leads the practitioner to determine its isolated or associated character, in order to characterise its possible belonging to a syndromic entity. In this context, the realization of genetic analysis more precise and wider allowing a return of the results in a time compatible with an evolutive pregnancy, gives to the geneticist a central role in the management of these couples. The main challenge lies in obtaining a set of concordant clinical and biological clues, enabling the genetic results identified to be interpreted correctly, the optimised functioning of the ultrasound practitioner - geneticist duo is therefore fundamental. This results in a complex information to deliver, in the fact that the clinical translation of an ear anomaly in antenatal can go from an isolated aesthetic anomaly to a genetic syndrome with neurodevelopmental disorder. The objective of this work is to describe, from a methodological analysis of antenatal ears, the accessible malformative entities, isolated or associated, and to discuss the problems in the need or not to propose their screening.


Asunto(s)
Pruebas Genéticas , Tamizaje Masivo , Femenino , Humanos , Embarazo , Ultrasonografía , Ultrasonografía Prenatal/métodos
6.
J Gynecol Obstet Hum Reprod ; 51(1): 102233, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34571198

RESUMEN

OBJECTIVE: To determine whether the predictive value of AFC for ovarian response to stimulation for IVF depends on the day of the menstrual cycle when ultrasound is performed. METHODS: 410 women undergoing their first IVF cycle were included. All the women had AFC performed twice. The first measurement, random AFC (r-AFC), was performed during the fertility workup whatever the day of their menstrual cycle. Three groups were constituted according to the period of ultrasound performance: at early follicular phase i.e., day 1 to day 6 (eFP-AFC); at mid follicular phase i.e., day 7 to 12 (mFP-AFC) and at luteal phase i.e., day 13 or after (LP-AFC). A second AFC measurement was performed before the start of the ovarian stimulation (SD1-AFC). AMH dosing was done in the early follicular phase. RESULTS: Random AFC (r-AFC) was correlated to AMH (r = 0.69; p<0.001), SD1-AFC (r = 0.75; p<0.001) and number of oocytes retrieved (r = 0.49; p<0.001). When regarding AFC depending on the cycle day group, the correlation with AMH was 0.65, 0.66 and 0.85 for the eFP-AFC, the mFP-AFC and the LP-AFC respectively (all p were <0.001). The ROC analysis showed the same predictive value for good ovarian response (more than 6 oocytes retrieved) for the eFP-AFC, mFP-AFC and LP-AFC (AUC 0.73, 0.75 and 0.84 respectively; p = 0.28). The AUC of r-AFC (0.76) were similar to those of AMH (0.74) and SD1-AFC (0.74) (p = 0.21 and 0.92 respectively). CONCLUSION: AFC is strongly correlated with AMH and highly predictive of good ovarian response during the whole menstrual cycle.


Asunto(s)
Hormona Antimülleriana/análisis , Fase Folicular/metabolismo , Folículo Ovárico/diagnóstico por imagen , Inducción de la Ovulación/instrumentación , Adulto , Femenino , Fertilización In Vitro/métodos , Fertilización In Vitro/tendencias , Fase Folicular/fisiología , Humanos , Folículo Ovárico/fisiología , Inducción de la Ovulación/métodos , Estudios Retrospectivos
9.
Ultrasound Obstet Gynecol ; 33(6): 716-9, 2009 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-19479679

RESUMEN

We describe the findings on computed tomography (CT) in a prenatally diagnosed case of bladder exstrophy, and compare them with the findings on two- and three-dimensional sonography. The CT data of the affected fetus were compared with the CT findings of 14 fetuses with normal bony pelvises. The CT images showed differences in the structure of the bony pelvis in the case of bladder exstrophy, with a wide gap between the iliopubic and ischiopubic rami and a widening of the iliac bones. CT scanning was useful in confirming the sonographic diagnosis of bladder exstrophy, and it may also be helpful for planning early surgery following delivery.


Asunto(s)
Extrofia de la Vejiga/diagnóstico por imagen , Huesos Pélvicos/diagnóstico por imagen , Adulto , Extrofia de la Vejiga/cirugía , Femenino , Humanos , Recién Nacido , Embarazo , Tomografía Computarizada Espiral/métodos , Resultado del Tratamiento , Ultrasonografía Prenatal/métodos
10.
Ultrasound Obstet Gynecol ; 34(5): 521-5, 2009 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-19830790

RESUMEN

OBJECTIVE: To evaluate the clinical use of hourly fetal urine production rate (HFUPR) in polyhydramnios. METHODS: This was a retrospective review of 33 singleton pregnancies with polyhydramnios, 30 of them unexplained and three due to gastrointestinal atresia. HFUPR was estimated using three-dimensional ultrasound and was compared with recently established nomograms. Abnormal midterm outcome, defined as diagnosis or persistence of pathology after the neonatal period until the age of 2 years, was analyzed according to prenatal HFUPR measurements and other polyhydramnios characteristics. RESULTS: Seventeen of the 30 fetuses with unexplained polyhydramnios had an HFUPR above the 95(th) centile, and five (29.4%) of them developed midterm disorders. None of the 13 with normal HFUPR developed midterm disorders. The HFUPR was 1.9 (SD, 0.7) multiples of the median (MoM) in fetuses with an adverse childhood outcome and 1.4 (SD, 1.2) in fetuses with normal childhood outcome (P = 0.34). In the three fetuses with gastrointestinal atresia, the HFUPR was significantly lower than in those with unexplained polyhydramnios (P = 0.003). CONCLUSION: HFUPR was associated with the mechanism of polyhydramnios but failed to help in the prognosis of unexplained polyhydramnios because of lack of power. Children with prenatal unexplained polyhydramnios and HFUPR above the 95(th) centile should nevertheless receive detailed pediatric follow-up.


Asunto(s)
Líquido Amniótico/diagnóstico por imagen , Diuresis/fisiología , Feto/fisiología , Polihidramnios/diagnóstico por imagen , Sistema Urogenital/diagnóstico por imagen , Femenino , Edad Gestacional , Humanos , Lactante , Recién Nacido , Masculino , Polihidramnios/etiología , Embarazo , Pronóstico , Estudios Retrospectivos , Ultrasonografía Prenatal/métodos , Orina , Sistema Urogenital/embriología
11.
Gynecol Obstet Fertil ; 37(5): 425-31, 2009 May.
Artículo en Francés | MEDLINE | ID: mdl-19409831

RESUMEN

The accurate assessment of ovarian reserve is an essential step before the treatment of infertile couples. Ovarian reserve could either be evaluated through clinical or biological parameters, but ultrasound plays a remarkable role, since it permits the direct visualization and count of ovarian antral follicles. Nevertheless, the available literature data are conflicting about the real sensibility and specificity of this method to predict the exact number of retrieved oocytes or the occurrence of pregnancy after a procedure for medical assisted reproduction. New technologies have been developed, as the 3D-ultrasound, who does not ameliorate ultrasound accuracy, but permits the reduction of the time necessary for patient's examination and virtually eliminates inter- and intra-observer bias. The place of the ovarian artery flow evaluation by Doppler remains unclear and need more studies.


Asunto(s)
Infertilidad Femenina/diagnóstico por imagen , Ovario/diagnóstico por imagen , Ovario/fisiopatología , Adulto , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Recuperación del Oocito , Folículo Ovárico/patología , Ovario/anatomía & histología , Embarazo , Técnicas Reproductivas Asistidas , Ultrasonografía
13.
Fetal Diagn Ther ; 24(4): 444-7, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-19023211

RESUMEN

Patent urachus cyst is a rare umbilical anomaly, which is poorly detected prenatally and frequently confounded with pseudo bladder exstrophy or omphalocele. A 27-year-old woman was referred to our prenatal diagnosis centre at 18 weeks of gestation after diagnosis of a megabladder and 2 umbilical cord cysts. Subsequent 2D, 3D and 4D ultrasound examinations and fetal magnetic resonance imaging (MRI) revealed a typical umbilical cyst and an extra-abdominal cyst, communicating with the vertex of the fetal bladder through a small channel that increased in size when the fetus voided urine. Termination of pregnancy occured at 31 weeks because of associated cerebral septal agenesis, and autopsy confirmed the prenatal diagnosis of urachus cyst. Few cases of urachus cyst diagnosed prenatally are reported in literature, but none were associated with other extra-abdominal disorders and none used 3D, 4D and fetal MRI. Our case illustrated the efficiency in prenatal diagnosis of 3D and 4D ultrasound examinations. This could help pediatrician surgeons to explain to a couple about neonatal surgical repair and plastic reconstruction in the prenatal period.


Asunto(s)
Imagen por Resonancia Magnética , Ultrasonografía Prenatal/métodos , Quiste del Uraco/diagnóstico por imagen , Uraco/anomalías , Uraco/diagnóstico por imagen , Anomalías Múltiples , Adulto , Resultado Fatal , Femenino , Humanos , Recién Nacido , Masculino , Embarazo
14.
Int J Oral Maxillofac Surg ; 47(1): 44-47, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28673724

RESUMEN

Three-dimensional (3D) ultrasound has significantly improved prenatal screening and perinatal care in the area of cleft lip/palate and other deformities, providing essential preoperative information to the surgical team. However, current 3D reconstruction modalities are limited primarily to display on a two-dimensional surface. In contrast, a 3D printed haptic model allows both the surgeon and the parents to develop a better understanding of the anatomy and the surgical procedure through the ability to interact directly with the printed model. The production of a 3D printed haptic model of cleft lip and palate obtained from a surface-rendered oropalatal sonographic view is presented here. The development of this 3D printed haptic model will allow the surgical team to perform preoperative planning with a highly accurate medical model, and it therefore represents a new tool in the management of cleft lip/palate. It also provides better prenatal information for the parents.


Asunto(s)
Labio Leporino/diagnóstico por imagen , Labio Leporino/cirugía , Fisura del Paladar/diagnóstico por imagen , Fisura del Paladar/cirugía , Imagenología Tridimensional , Modelos Anatómicos , Impresión Tridimensional , Ultrasonografía Prenatal , Labio Leporino/embriología , Fisura del Paladar/embriología , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Embarazo , Programas Informáticos
15.
J Gynecol Obstet Hum Reprod ; 47(5): 183-186, 2018 May.
Artículo en Inglés | MEDLINE | ID: mdl-29475047

RESUMEN

OBJECTIVE: To assess the efficacy of office hysteroscopy and 3D ultrasound for the diagnostic of uterine anomalies after late foetal loss. METHOD: This retrospective observational study took place in the gynaecologic unit of a teaching hospital from 2009 to 2014. Women with late foetal loss (<22 weeks of gestation) had an office hysteroscopy and 3D ultrasound within three months after delivery. The results of the ultrasound and hysteroscopy were recorded and compared. RESULTS: Eighty women were included with a mean age of 29.8 years (28.2-31.4). Forty-seven women had both hysteroscopy and 3D ultrasound, and a uterine cavity's anomaly (bicornuate uterus, T-Shape uterus and septate uterus) was found in ten women (21%) at 3D sonography and in 13 women (28%) at office hysteroscopy. Concordance between the two exams was very good with a kappa at 0.83. In three cases, a uterine cavity's anomaly was found at hysteroscopy whereas sonography was normal. Anomalies at ultrasound (uterine cavity's anomaly, myometrium anomaly or ovarian anomaly) were found in 27.6% of cases. CONCLUSIONS: Both 3D ultrasound and office hysteroscopy are useful for assessment of the uterine cavity after late foetal loss. The application of these two exams is important, as hysteroscopy is generally used for assessment of the uterine cavity and endometrium, while 3D ultrasound is generally used to identify the precise type of uterine malformation and for the examination of the myometrium and annexes.


Asunto(s)
Muerte Fetal , Histeroscopía/normas , Imagenología Tridimensional/normas , Ultrasonografía/normas , Útero/diagnóstico por imagen , Adulto , Femenino , Humanos , Embarazo , Segundo Trimestre del Embarazo , Estudios Retrospectivos , Útero/anomalías
17.
J Gynecol Obstet Hum Reprod ; 46(4): 317-321, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28643658

RESUMEN

INTRODUCTION: French guidelines regarding the minimum criteria for gynaecological ultrasound were given in a recent report in 2016, by the French National College of Obstetricians and Gynaecologists (CNGOF). An accurate report is essential for the optimal care of women, especially those presenting myomas. The goal of this study was to evaluate the quality of gynaecological ultrasound reports for women with type 0 to 2 uterine myomas, referring to the items contained in the French guidelines. MATERIALS AND METHODS: A retrospective descriptive study was conducted from reports of ultrasounds performed in private offices and in the gynaecologic department of a hospital, between June 2014 and June 2016 (before the report of CNGOF). These reports involved women who underwent hysteroscopic resection of myoma(s). A search of validated items was conducted for all of the reports, and the missing items were analysed. The different types of practitioners and between hospital and private medical offices were also compared with Chi-square tests. RESULTS: A total of 138 reports were analysed; 71 were performed in private offices and 67 were performed in the gynaecologic unit of the hospital. Many items were missing in the reports, with disparities between the type of institution (private offices or hospital) and the speciality of practitioners (radiologists or gynaecologists). Specific items regarding myomas, such as the International Federation of Gynaecologists and Obstetricians (FIGO) classification or measurement of the posterior wall, were more often missing in reports from radiologists (89.7% and 79.5%, respectively) than in reports from gynaecologists (21.2% and 34.3%, respectively) (P<0.05). A significant difference was also observed for these data between private offices' reports and hospitals' reports. Items relative to ultrasound structures, such as the appearance of myomas or associated abdominal effusion, were more frequently missing in gynaecologists' reports (88.9% and 49.5%, respectively) compared to radiologists' reports (56.4% and 12.8%, respectively) (P<0.05). CONCLUSIONS: Certain items are present in all the reports, while others are insufficiently mentioned. These inequalities can be explained in part by the type of practice; however, methods to overcome these difficulties must be developed. Information campaigns to educate professionals on the minimum reporting and training conducted jointly by radiologists and gynaecologist surgeons might improve reports and improve the care of women.


Asunto(s)
Ginecología , Leiomioma/diagnóstico , Pelvis/diagnóstico por imagen , Guías de Práctica Clínica como Asunto , Ultrasonografía/normas , Neoplasias Uterinas/diagnóstico , Técnicas de Diagnóstico Obstétrico y Ginecológico/clasificación , Técnicas de Diagnóstico Obstétrico y Ginecológico/normas , Femenino , Francia/epidemiología , Adhesión a Directriz/estadística & datos numéricos , Ginecología/métodos , Ginecología/normas , Humanos , Leiomioma/patología , Obstetricia/métodos , Obstetricia/normas , Pautas de la Práctica en Medicina/normas , Pautas de la Práctica en Medicina/estadística & datos numéricos , Garantía de la Calidad de Atención de Salud , Estudios Retrospectivos , Sociedades Médicas/normas , Ultrasonografía/métodos , Neoplasias Uterinas/patología
18.
J Gynecol Obstet Hum Reprod ; 46(7): 571-573, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28676451

RESUMEN

OBJECTIVE: Three-dimensional sonography is a good alternative method to assess the position of microinserts. Adequate position after three months allows for the interruption of other contraception. Objective is to evaluate inter-observer reproducibility of the interpretation of coronal transvaginal 3D ultrasound view of the uterus to evaluate the position of Essure®. STUDY DESIGN: Inter-observer reproducibility study. Fifty women underwent successful bilateral placement of microinserts (Essure®) by hysteroscopy in the Department of Gynaecology of a teaching hospital and were included in the study. At three month, 3D ultrasound coronal views of the fifty uterus (accounting for one hundred microinserts) were assessed by five different observers and microinsert position was classified according to the classification described by Legendre et al. Inter-observer reproducibility in reading the 3D coronal view of the uterus was evaluated. RESULTS: The k-value was disparate, from 0.26 to 0.82. Inter-observer reproducibility then ranged from fair to almost perfect, depending on a prior knowledge of the position classification. CONCLUSIONS: Transvaginal 3D coronal view of the uterus is sufficient to assess the positioning of the microinserts when the practionner or the surgeon is familiar with the classification method.


Asunto(s)
Histeroscopía/métodos , Interpretación de Imagen Asistida por Computador , Imagenología Tridimensional , Dispositivos Intrauterinos , Ultrasonografía/métodos , Útero/diagnóstico por imagen , Adulto , Competencia Clínica , Trompas Uterinas/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Histerosalpingografía , Interpretación de Imagen Asistida por Computador/métodos , Interpretación de Imagen Asistida por Computador/normas , Imagenología Tridimensional/métodos , Imagenología Tridimensional/normas , Migración de Dispositivo Intrauterino , Dispositivos Intrauterinos/efectos adversos , Masculino , Implantación de Prótesis , Reproducibilidad de los Resultados , Esterilización Tubaria/métodos , Cirujanos/normas , Útero/patología
19.
J Gynecol Obstet Biol Reprod (Paris) ; 45(2): 139-46, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26321621

RESUMEN

OBJECTIVE: Pelvic floor muscle training (PFMT) is the first step of treatment for stress urinary incontinence (SUI). Patients must perform self-retraining exercises of the perineal muscles at home in order to maintain the benefit of the physiotherapy. The aim of this study is to assess the benefit of a perineal electro-stimulator, using three-dimensional ultrasound, during this home-care phase. MATERIALS AND METHODS: A longitudinal prospective study was conducted between May 2012 and May 2013. All patients with de novo SUI benefited from PFMT followed by a self-maintenance of perineal rehabilitation at home with the Keat(®) Pro system. The primary endpoint was the biometric of the levator ani and it was assessed by three-dimensional perineal ultrasound at inclusion, after conventional rehabilitation and at the end of the study after self-rehabilitation. RESULTS: Ten patients were included. All patients (100%) showed a clinical improvement of SUI. The quality of life was significantly improved after PFMT vs. inclusion (P=0.014) and after self-rehabilitation vs. after PFMT (P=0.033). Levator ani muscles were significantly thicker after conventional rehabilitation than at baseline (P=0.004) and significantly thicker after self-rehabilitation than after PFMT (P=0.009). CONCLUSIONS: Conducting self-rehabilitation in addition to conventional PFMT objectively improves the perineal muscle building achieved after conventional rehabilitation.


Asunto(s)
Terapia por Ejercicio , Diafragma Pélvico , Perineo , Autocuidado/métodos , Incontinencia Urinaria de Esfuerzo/rehabilitación , Adulto , Terapia por Ejercicio/instrumentación , Terapia por Ejercicio/métodos , Femenino , Servicios de Atención de Salud a Domicilio , Humanos , Imagenología Tridimensional , Persona de Mediana Edad , Diafragma Pélvico/diagnóstico por imagen , Diafragma Pélvico/fisiología , Perineo/diagnóstico por imagen , Perineo/fisiología , Calidad de Vida , Autocuidado/instrumentación , Resultado del Tratamiento , Ultrasonografía , Incontinencia Urinaria de Esfuerzo/diagnóstico por imagen
20.
Gynecol Obstet Fertil ; 43(11): 693-8, 2015 Nov.
Artículo en Francés | MEDLINE | ID: mdl-26603330

RESUMEN

OBJECTIVES: To determine the interest of saline contrast sonohysterography in the evaluation of number, size and shape of cesarean scar defects in comparison with 3D-transvaginal ultrasound examination. METHODS: Patients who had surgical reparation of cesarean scar defect by operative hysteroscopy were included in this retrospective study. Before surgery, they all had 3D-transvaginal ultrasound examination and saline contrast sonohysterography to establish the diagnosis. Then those two exams were compared to determine which one is better for cesarean scar defect evaluation, in terms of diagnosis and severity. RESULTS: Fourteen patients were enrolled, they underwent transvaginal ultrasound and saline contrast sonohysterography before the surgery. 3D-transvaginal ultrasound examination made the diagnosis in 50% of patients with cesarean scar defect, whereas saline contrast sonohysterography enabled to detect 86% of defects, in comparison with hysteroscopy (100%). In 29% of patients, the size and depth of the cesarean scar defect was more important with saline contrast sonohysterography and hysteroscopy than expected by 3D-transvaginal ultrasound examination. After surgical repair, symptoms improvement was found in 82% of case (pain or abnormal uterine bleeding), and fertility was restored in 67%. CONCLUSION: Saline contrast sonohysterography is better to characterize cesarean scar defects than 3D-transvaginal ultrasound, with a higher sensibility. Moreover, it evaluates more precisely the size and shape of the defect, thus severity.


Asunto(s)
Cesárea/efectos adversos , Cicatriz/diagnóstico por imagen , Histeroscopía , Ultrasonografía/métodos , Útero/diagnóstico por imagen , Adulto , Cicatriz/patología , Cicatriz/cirugía , Femenino , Humanos , Embarazo , Estudios Retrospectivos , Cloruro de Sodio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA