Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Catheter Cardiovasc Interv ; 101(1): 60-71, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378683

RESUMEN

BACKGROUND: The polymer-free biolimus coated stent (BioFreedom) was shown to be superior to bare metal stents in the LEADERS FREE randomized trial in high bleeding risk (HBR) patients treated with 1-month dual antiplatelet therapy (DAPT). However, there is limited outcome data with this device in an all-comers' population. METHODS: We conducted a prospective single-arm study of patients undergoing percutaneous coronary intervention with the polymer-free biolimus coated stent in 25 centers in France with wide inclusion criteria including multivessel disease, complex lesions, and acute coronary syndromes. The primary endpoint was the incidence of target lesion failure (TLF), a composite of cardiac death or target-vessel myocardial infarction (MI) or clinically indicated target lesion revascularization (ci-TLR) at 1-year. The patient population was classified according to the presence (or not) of HBR criteria according to the recent ARC-HBR definition. RESULTS: Between April 2019 and April 2020, 1497 patients were enrolled. TLF occurred in 101 (6.9%) patients, including cardiac death in 35 (2.4%), target vessel MI in 20 (1.4%) and ci-TLR in 65 (4.5%) of them. There were 491 HBR patients (32.8%) and 1006 non-HBR patients. The median duration of DAPT was 74 days in the HBR group versus 348 days in the non-HBR group (p < 0.0001). TLF occurred in 44 (9.2%) of the HBR group and in 57 (5.8%) of the non-HBR group (relative risk 1.62 [95% confidence interval: 1.10-2.41], p = 0015). Compared to the non-HBR group, HBR patients had higher rates of cardiac death (4.4% vs. 1.4%, p = 0.0005) and target vessel MI (2.9% vs. 0.6%, p = 0.0003), but similar rates of ci-TLR. BARC 3-5 bleeding occurred in 6.2% of the HBR group versus 1.4% of the non-HBR group (p < 0.0001). CONCLUSION: In this multicenter all-comers study, HBR patients treated with a polymer-free biolimus coated stent had, compared to non-HBR patients, an increased risk of cardiac death and MI, and despite a shorter duration of DAPT, continued to have higher rates of BARC 3-5 bleeding.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Inhibidores de Agregación Plaquetaria/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Estudios Prospectivos , Stents Liberadores de Fármacos/efectos adversos , Sirolimus/efectos adversos , Diseño de Prótesis , Resultado del Tratamiento , Stents/efectos adversos , Infarto del Miocardio/etiología , Hemorragia/inducido químicamente , Francia , Muerte
2.
Catheter Cardiovasc Interv ; 90(6): 890-897, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28544186

RESUMEN

OBJECTIVES: The French Ebiomatrix registry aimed to confirm the results of the Leaders trial in an all-comer population in France. BACKGROUND: The Leaders trial showed the Biolimus-eluting-sent (BES) to be equivalent to the Cypher stent in terms of safety and efficacy at 1 year and superior regarding stent thrombosis after 1 year. METHODS: BES recipients were enrolled in 42 French centers with up to 24-month clinical follow up. RESULTS: 2365 patients were included. Mean age: 65.7 ±11.2 years, 76.1% males, 31.8% had diabetes, 36.5% ACS (28.7% non-ST-elevation MI and 7.8% with ST-elevation MI). 1.7 ± 1.0 stents/patient were implanted and procedural success was 99.5%. 12-month follow-up was completed in 94.3% patients and 24 months in 91.4%. MACCE rates at 12 and 24 months were 5.8% and 9% (all cause-death 1.5% and 2.2%; stent thrombosis definite/probable 0.4% and 0.6%), respectively. MACCE were not significantly higher in diabetic patients compared with non-diabetics but cardiac death was higher (1.6% vs. 0.6%, P = 0.01 at 1 year and 1.9% vs. 0.6, P = 0.005 at 2 years) as was stent thrombosis (0.9% vs. 0.2%, P = 0.009 and 1.2 vs. 0.3% P = 0.008). Compared with non-ACS patients, MACCE was significantly higher in the ACS subgroup (7.5% vs. 4.8%, P = 0.001 at 1 year and 10.3% vs.8.1%, P = 0.07 at 2 years). CONCLUSION: In this large real-world registry, the BES with biodegradable polymer showed excellent acute and mid-term outcomes with a 5.8% and 9% rate of MACCE at one and 2 years and a very low rate of stent thrombosis between 1 and 2 years (0.2%), thus demonstrating the replicability of the LEADERS trial in a registry population. © 2017 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA