Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
BMC Womens Health ; 23(1): 595, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37953251

RESUMEN

BACKGROUND: Ovarian neuroendocrine carcinoma (O-NEC) is a relatively uncommon neoplasm, and the current knowledge regarding its diagnosis and management is limited. In this series, our objective was to provide an overview of the clinicopathological characteristics of the disease by analyzing clinical case data to establish a theoretical foundation for the diagnosis and management of O-NEC. CASE PRESENTATION: We included three patients in the present case series, all of whom were diagnosed with primary O-NEC based on pathomorphological observation and immunohistochemistry. Patient 1 was a 62-year-old patient diagnosed with small cell carcinoma (SCC) of the pulmonary type. Post-surgery, the patient was diagnosed with stage II SCC of the ovary and underwent standardized chemotherapy; however, imaging examinations conducted at the 16-month follow-up revealed the existence of lymph node metastasis. Unfortunately, she passed away 21 months after the surgery. The other two patients were diagnosed with carcinoid tumors, one at age 39 and the other at age 71. Post-surgery, patient 2 was diagnosed with a carcinoid in the left ovary, whereas patient 3 was diagnosed with a carcinoid in her right ovary based on clinical evaluation. Neither of the cases received adjuvant therapy following surgery; however, they have both survived for 9 and 10 years, respectively, as of date. CONCLUSION: Primary O-NECs are rare and of diverse histological types, each of which has its own unique biological features and prognosis. SCC is a neoplasm characterized by high malignancy and a poor prognosis, whereas carcinoid tumors are of lesser malignancy and have a more favorable prognosis.


Asunto(s)
Tumor Carcinoide , Carcinoma Neuroendocrino , Carcinoma de Células Pequeñas , Tumores Neuroendocrinos , Neoplasias Ováricas , Femenino , Humanos , Adulto , Anciano , Persona de Mediana Edad , Carcinoma Neuroendocrino/diagnóstico , Carcinoma Neuroendocrino/terapia , Carcinoma Neuroendocrino/patología , Tumores Neuroendocrinos/diagnóstico , Tumores Neuroendocrinos/patología , Pronóstico , Carcinoma de Células Pequeñas/diagnóstico , Carcinoma de Células Pequeñas/terapia , Carcinoma de Células Pequeñas/patología , Tumor Carcinoide/diagnóstico , Tumor Carcinoide/patología , Carcinoma Epitelial de Ovario , Neoplasias Ováricas/diagnóstico , Neoplasias Ováricas/terapia
2.
Acta Crystallogr Sect E Struct Rep Online ; 67(Pt 10): m1464-5, 2011 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-22065024

RESUMEN

In the centrosymmetric dinuclear title complex, [Mn(2)(C(16)H(10)NO(2))(4)(C(12)H(8)N(2))(2)(H(2)O)(2)]·2H(2)O, the Mn(II) cation is in a distorted octa-hedral coordination geometry defined by two N atoms from a 1,10-phenanthroline ligand, one water O atom and three O atoms from three 2-phenyl-quinoline-4-carboxyl-ate anions. A pair of 2-phenyl-quinoline-4-carboxyl-ate anions bridge two Mn cations, forming the dinuclear mol-ecule. An intra-moleculr O-H⋯O hydrogen bond occurs. Inter-molecular O-H⋯O and O-H⋯N hydrogen bonds are present in the crystal structure.

3.
Zhongguo Zhong Yao Za Zhi ; 33(18): 2077-80, 2008 Sep.
Artículo en Zh | MEDLINE | ID: mdl-19160788

RESUMEN

OBJECTIVE: To investigate the chemical constituents of Desmodium blandum and their cytotoxic activity against the growth of several tumor cells. METHOD: Various chromatographic techniques including silica gel, Sephadex LH-20 column chromatography were employed for the isolation and purification of the constituents. The structures of compounds were elucidated by spectral analyses (IR, UV, NMR, MS). Their cytotoxic activity was then studied. RESULT: Eight compounds were isolated from the stems of D. blandum and identified as N, N-dimethyltryptamine (1), 5-methoxy-N, N-dimethyltryptamine (2), citrusinol (3), yukovanol (4), (Z)-1-(4-hydroxy-2, 3-dimethoxyphenyl)-3-(4-hydroxyphenyl) propene (5), (Z)-1-(3-hydroxy-2, 4-dimethoxy-phenyl)-3-(4-hydroxy-3-methoxy-phenyl) propene (6), methylprotocatechuate (7), katuranin (8). CONCLUSION: Among these compounds, compound 6 was isolated from D. blandum for the first time. In the MTT test, compounds 2 and 6 exhibit cytotoxic activities against the KB cell, and compounds 3 and 6 exhibit the same activities against the HepG2 cell.


Asunto(s)
Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/toxicidad , Fabaceae/química , Hojas de la Planta/química , Alquenos/química , Alquenos/farmacología , Derivados del Benceno/química , Derivados del Benceno/farmacología , Línea Celular Tumoral , Proliferación Celular/efectos de los fármacos , Humanos , Espectroscopía de Resonancia Magnética , Estructura Molecular , N,N-Dimetiltriptamina/química , Espectrometría de Masa por Ionización de Electrospray , Espectrofotometría Infrarroja
4.
Biosens Bioelectron ; 22(7): 1245-50, 2007 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-16777402

RESUMEN

8-Hydroxy-2'-deoxyguanosine (8-OH-dG) has attracted enormous attention in recent years because it has been acknowledged as a typical biomarker of oxidative DNA damage. In this paper, the electrochemical performance of 8-OH-dG at the poly(3-methylthiophene) (P3MT) modified glassy carbon electrode (GCE) was investigated by cyclic voltammetry (CV) and linear sweep voltammetry (LSV). The conducting polymer P3MT can effectively decrease the oxidation peak potential of 8-OH-dG and greatly enhance its peak current. In 0.1 M pH 7.0 phosphate buffer solution (PBS), the anodic peak currents of cyclic voltammograms are linear with the 8-OH-dG concentration in two intervals, viz. 0.700-35.0 microM and 35.0-70.0 microM, with the correlative coefficients of 0.9992 and 0.9995, respectively. The detection limit of 8-OH-dG can be estimated to be 0.100 microM (S/N=3). This modified electrode can be used to detect the amount of 8-OH-dG in human urine. Furthermore, the effects of scan rate, pH, and interference of uric acid (UA) for the voltammetric behavior and detection of 8-OH-dG are also discussed. This proposed modified electrode also shows excellent reproducibility and stability that makes it an ideal candidate for amperometric detection of 8-OH-dG in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).


Asunto(s)
Carbono , Desoxiguanosina/análogos & derivados , Electroquímica/instrumentación , Polímeros , Tiofenos , 8-Hidroxi-2'-Desoxicoguanosina , Desoxiguanosina/análisis , Desoxiguanosina/química , Electrodos
5.
Biosens Bioelectron ; 22(5): 664-9, 2006 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-16621509

RESUMEN

A poly(3-methylthiophene) modified glassy carbon electrode coated with Nafion/single-walled carbon nanotubes film was fabricated and used for highly selective and sensitive determination of dopamine. The hybrid film surface of the modified electrode was characterized by scanning electrochemical microscopy (SECM) and the results indicated that the carbon nanotubes were dispersed uniformly on the conductive polymer. The experimental results suggest that the hybrid film modified electrode combining the advantages of poly(3-methylthiophene), carbon nanotubes with Nafion exhibits dramatic electrocatalytic effect on the oxidation of dopamine (DA) and results in a marked enhancement of the current response. In 0.1M phosphate buffer solution (PBS) of pH 7.0, the differential pulse voltammetric (DPV) peak heights are linear with DA concentration in three intervals, viz. 0.020-0.10 microM, 0.10-1.0 microM and 1.0-6.0 microM, with correlation coefficients of 0.9993, 0.9996 and 0.9993, respectively. The detection limit of 5.0 nM DA could be estimated (S/N=3). Moreover, the interferences of ascorbic acid (AA) and uric acid (UC) are effectively diminished. This hybrid film modified electrode can be applied to the determination of DA contents in dopamine hydrochloride injection and human serum. These attractive features provide a potential application for either in vitro measurement of DA in the presence of excess AA and UA or as detectors in flow injection analysis (FIA) and high performance liquid chromatography (HPLC).


Asunto(s)
Técnicas Biosensibles/instrumentación , Dopamina/análisis , Electroquímica/instrumentación , Polímeros de Fluorocarbono/química , Microelectrodos , Nanotubos de Carbono/química , Polímeros/química , Tiofenos/química , Técnicas Biosensibles/métodos , Materiales Biocompatibles Revestidos/química , Electroquímica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Nanotubos de Carbono/ultraestructura , Tamaño de la Partícula , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA