Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38512739

RESUMEN

This study proposes a charge-mode neural stimulator for electrical stimulation systems that utilizes a capacitor-reuse technique with a residual charge detector and achieves active charge balancing simultaneously. The design is mainly used for epilepsy suppression systems to achieve real-time symptom relief during seizures. A charge-mode stimulator is adopted in consideration of the complexity of circuit design, the high voltage tolerance of transistors, and system integration requirements in the future. The residual charge detector allows users to understand the current stimulus situation, enabling them to make optimal adjustments to the stimulation parameters. On the basis of the information on actual stimulation charge, active charge balancing can effectively prevent the accumulation of mismatched charges on electrode impedance. The capacitor- and phase-reuse techniques help realize high integration of the overall stimulator circuit in consideration of the commonality of the use of a capacitor and charging/discharging phase in the stimulation circuit and charge detector. The proposed charge-mode neural stimulator is implemented in a TSMC 0.18 µm 1P6M CMOS process with a core area of 0.2127 mm2. Measurement results demonstrate the accuracy of the stimulation's functionality and the programmable stimulus parameters. The effectiveness of the proposed charge-mode neural stimulator for epileptic seizure suppression is verified through animal experiments.

2.
IEEE Trans Biomed Circuits Syst ; 15(3): 537-548, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34101596

RESUMEN

This work presents a portable wireless urine detection system which consists of an electrochemical readout application specific integrated circuit (ASIC) and a biosensor composed of 2, 2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid) and carbon nanotube (ABTS-CNT) for the detection of urine albumin-to-creatinine ratio (UACR). The ASIC includes a potentiostat, a digital circuitry and a power management circuit which can perform electrochemistry techniques with a dual-channel screen-printing carbon electrode (SPCE). Electrochemical experiments on the proposed biosensor (SPCE|ABTS-CNT|Nafion) have revealed promising sensing characteristics for creatinine and human serum albumin detection. Practical urine tests has demonstrated the capability of the proposed urine detection system for UACR detection with both the power-efficient readout ASIC and the ABTS-CNT biosensor. A user-friendly prototype has also been designed which can be useful for either personal health administrationor homecare.


Asunto(s)
Técnicas Biosensibles , Nanotubos de Carbono , Benzotiazoles , Técnicas Electroquímicas , Electroquímica , Humanos , Ácidos Sulfónicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA