1.
Nature ; 603(7899): 58-62, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35236975

RESUMEN

The interaction of intense particle bunches with plasma can give rise to plasma wakes1,2 capable of sustaining gigavolt-per-metre electric fields3,4, which are orders of magnitude higher than provided by state-of-the-art radio-frequency technology5. Plasma wakefields can, therefore, strongly accelerate charged particles and offer the opportunity to reach higher particle energies with smaller and hence more widely available accelerator facilities. However, the luminosity and brilliance demands of high-energy physics and photon science require particle bunches to be accelerated at repetition rates of thousands or even millions per second, which are orders of magnitude higher than demonstrated with plasma-wakefield technology6,7. Here we investigate the upper limit on repetition rates of beam-driven plasma accelerators by measuring the time it takes for the plasma to recover to its initial state after perturbation by a wakefield. The many-nanosecond-level recovery time measured establishes the in-principle attainability of megahertz rates of acceleration in plasmas. The experimental signatures of the perturbation are well described by simulations of a temporally evolving parabolic ion channel, transferring energy from the collapsing wake to the surrounding media. This result establishes that plasma-wakefield modules could be developed as feasible high-repetition-rate energy boosters at current and future particle-physics and photon-science facilities.

2.
Phys Rev Lett ; 129(24): 244801, 2022 Dec 09.
Artículo en Inglés | MEDLINE | ID: mdl-36563240

RESUMEN

We report on a novel, noninvasive method applying Thomson scattering to measure the evolution of the electron beam energy inside a laser-plasma accelerator with high spatial resolution. The determination of the local electron energy enabled the in-situ detection of the acting acceleration fields without altering the final beam state. In this Letter we demonstrate that the accelerating fields evolve from (265±119) GV/m to (9±4) GV/m in a plasma density ramp. The presented data show excellent agreement with particle-in-cell simulations. This method provides new possibilities for detecting the dynamics of plasma-based accelerators and their optimization.

3.
Phys Rev Lett ; 126(1): 014801, 2021 Jan 08.
Artículo en Inglés | MEDLINE | ID: mdl-33480753

RESUMEN

Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3 GV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level.

4.
Phys Rev Lett ; 122(12): 129901, 2019 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-30978092

RESUMEN

This corrects the article DOI: 10.1103/PhysRevLett.121.194801.

5.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180184, 2019 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-31230576

RESUMEN

This paper discusses the properties of electron beams formed in plasma wakefield accelerators through ionization injection. In particular, the potential for generating a beam composed of co-located multi-colour beamlets is demonstrated in the case where the ionization is initiated by the evolving charge field of the drive beam itself. The physics of the processes of ionization and injection are explored through OSIRIS simulations. Experimental evidence showing similar features are presented from the data obtained in the E217 experiment at the FACET facility of the SLAC National Laboratory. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

6.
Phys Rev Lett ; 121(19): 194801, 2018 Nov 09.
Artículo en Inglés | MEDLINE | ID: mdl-30468609

RESUMEN

Active plasma lensing is a compact technology for strong focusing of charged particle beams, which has gained considerable interest for use in novel accelerator schemes. While providing kT/m focusing gradients, active plasma lenses can have aberrations caused by a radially nonuniform plasma temperature profile, leading to degradation of the beam quality. We present the first direct measurement of this aberration, consistent with theory, and show that it can be fully suppressed by changing from a light gas species (helium) to a heavier gas species (argon). Based on this result, we demonstrate emittance preservation for an electron beam focused by an argon-filled active plasma lens.

7.
Phys Rev Lett ; 120(12): 124802, 2018 Mar 23.
Artículo en Inglés | MEDLINE | ID: mdl-29694092

RESUMEN

Hollow channel plasma wakefield acceleration is a proposed method to provide high acceleration gradients for electrons and positrons alike: a key to future lepton colliders. However, beams which are misaligned from the channel axis induce strong transverse wakefields, deflecting beams and reducing the collider luminosity. This undesirable consequence sets a tight constraint on the alignment accuracy of the beam propagating through the channel. Direct measurements of beam misalignment-induced transverse wakefields are therefore essential for designing mitigation strategies. We present the first quantitative measurements of transverse wakefields in a hollow plasma channel, induced by an off-axis 20 GeV positron bunch, and measured with another 20 GeV lower charge trailing positron probe bunch. The measurements are largely consistent with theory.

8.
Nat Commun ; 11(1): 5984, 2020 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-33239645

RESUMEN

Plasma-wakefield accelerators driven by intense particle beams promise to significantly reduce the size of future high-energy facilities. Such applications require particle beams with a well-controlled energy spectrum, which necessitates detailed tailoring of the plasma wakefield. Precise measurements of the effective wakefield structure are therefore essential for optimising the acceleration process. Here we propose and demonstrate such a measurement technique that enables femtosecond-level (15 fs) sampling of longitudinal electric fields of order gigavolts-per-meter (0.8 GV m-1). This method-based on energy collimation of the incoming bunch-made it possible to investigate the effect of beam and plasma parameters on the beam-loaded longitudinally integrated plasma wakefield, showing good agreement with particle-in-cell simulations. These results open the door to high-quality operation of future plasma accelerators through precise control of the acceleration process.

9.
Sci Rep ; 7(1): 14180, 2017 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-29079817

RESUMEN

High gradients of energy gain and high energy efficiency are necessary parameters for compact, cost-efficient and high-energy particle colliders. Plasma Wakefield Accelerators (PWFA) offer both, making them attractive candidates for next-generation colliders. In these devices, a charge-density plasma wave is excited by an ultra-relativistic bunch of charged particles (the drive bunch). The energy in the wave can be extracted by a second bunch (the trailing bunch), as this bunch propagates in the wake of the drive bunch. While a trailing electron bunch was accelerated in a plasma with more than a gigaelectronvolt of energy gain, accelerating a trailing positron bunch in a plasma is much more challenging as the plasma response can be asymmetric for positrons and electrons. We report the demonstration of the energy gain by a distinct trailing positron bunch in a plasma wakefield accelerator, spanning nonlinear to quasi-linear regimes, and unveil the beam loading process underlying the accelerator energy efficiency. A positron bunch is used to drive the plasma wake in the experiment, though the quasi-linear wake structure could as easily be formed by an electron bunch or a laser driver. The results thus mark the first acceleration of a distinct positron bunch in plasma-based particle accelerators.

11.
Radiographics ; 17(1): 109-27, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9017803

RESUMEN

Duplication of the ureters is a common anomaly and is frequently encountered by radiologists. Duplication may be either complete or incomplete and is often accompanied by various complications. Incomplete duplication is most often associated with ureteroureteral reflux or ureteropelvic junction obstruction of the lower pole of the kidney. Complete duplication is most often associated with vesicoureteral reflux, ectopic ureterocele, or ectopic ureteral insertion, all of which are more common in girls than in boys. Vesicoureteral reflux affects the lower pole and can be outgrown, as in nonduplicated systems. Ectopic ureterocele and ectopic ureteral insertion affect the upper pole. The ectopic ureterocele produces a filling defect of variable size in the bladder; it can be identified with contrast material studies or ultrasound. Ectopic ureters may function poorly, be difficult to detect, and cause enuresis in girls. A fourth complication, ureteropelvic junction obstruction, occurs only in the lower pole and is seen in more boys than girls. Anatomic variants or anomalies as well as suboptimal imaging techniques can either simulate or obscure duplication, making diagnosis difficult. However, familiarity with the embryology of duplication and an awareness of the potential pitfalls of excretory urography and voiding cystourethrography will foster an understanding of the varied appearances and associated complications of both incomplete and complete duplication.


Asunto(s)
Uréter/anomalías , Diagnóstico por Imagen , Femenino , Humanos , Riñón/anomalías , Enfermedades Renales/complicaciones , Masculino , Obstrucción Ureteral/diagnóstico , Obstrucción Ureteral/etiología , Ureterocele/diagnóstico , Ureterocele/etiología , Reflujo Vesicoureteral/diagnóstico , Reflujo Vesicoureteral/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA