RESUMEN
RETRO-mapping was developed to automate activation mapping of atrial fibrillation (AF). We used the algorithm to study the effect of pulmonary vein isolation (PVI) on the frequency of focal, planar, and colliding wavefronts in persistent AF. An AFocusII catheter was placed on the left atrial endocardium to record 3 s of AF at six sites pre and post-PVI in patients undergoing wide circumferential PVI for persistent AF. RETRO-mapping analyzed each segment in 2 ms time windows for evidence of focal, planar, and colliding waveforms and the automated categorizations manually validated. Ten patients were recruited. A total of 360 s of data in 120 segments of 3 s from 60 left atrial locations were analyzed. RETRO-map was highly effective at identifying focal waves and collisions during AF. PVI significantly reduced collision frequency but not focal and planar activation frequency. However, there was a significant reduction in the dispersion of activation directions. Larger studies may help determine factors associated with successful clinical outcome.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Atrios Cardíacos , Algoritmos , Resultado del Tratamiento , RecurrenciaRESUMEN
INTRODUCTION: A quantifiable, automated standard of analyzing heart rhythm has long eluded cardiologists due, in part, to the limitations in technology and the ability to analyze large electrogram datasets. In this proof-of-concept study, we propose new measures to quantify plane activity in atrial fibrillation (AF) using our Representation of Electrical Tracking of Origin (RETRO)-Mapping software. METHODS: We recorded 30 s segments of electrograms at the lower posterior wall of the left atrium using a 20-pole double loop catheter (AFocusII). The data were analyzed with the custom RETRO-Mapping algorithm in MATLAB. Thirty second segments were analyzed for number of activation edges, conduction velocity (CV), cycle length (CL), activation edge direction, and wavefront direction. These features were compared across 34 613 plane edges in three types of AF: persistent AF treated with amiodarone (11 906 wavefronts), persistent AF without amiodarone (14 959 wavefronts), and paroxysmal AF (7748 wavefronts). Change in activation edge direction between subsequent frames and change in overall wavefront direction between subsequent wavefronts were analyzed. RESULTS: All activation edge directions were represented across the lower posterior wall. The median change in activation edge direction followed a linear pattern for all three types of AF with R2 = 0.932 for persistent AF treated without amiodarone, R2 = 0.942 for paroxysmal AF, and R2 = 0.958 for persistent AF treated with amiodarone. All medians and the standard deviation error bars remained below 45° (suggesting all activation edges were traveling within a 90° sector, a criterion for plane activity). The directions of approximately half of all wavefronts (56.1% for persistent without amiodarone, 51.8% for paroxysmal, 48.8% for persistent with amiodarone) were predictive of the directions of the subsequent wavefront. CONCLUSION: RETRO-Mapping can measure electrophysiological features of activation activity and this proof-of-concept study suggests that this can be extended to the detection of plane activity in three types of AF. Wavefront direction may have a role in future work for predicting plane activity. For this study, we focused more on the ability of the algorithm to detect plane activity and less the differences between the types of AF. Future work should be in validating these results with a larger data set and comparing with other types of activation such as rotational, collision, and focal. Ultimately, this work can be implemented in real-time for prediction of wavefronts during ablation procedures.
Asunto(s)
Amiodarona , Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Electrofisiología Cardíaca , Catéteres , Amiodarona/uso terapéutico , Ablación por Catéter/métodosRESUMEN
AIMS: Left bundle branch area pacing (LBBAP) is a promising method for delivering cardiac resynchronization therapy (CRT), but its relative physiological effectiveness compared with His bundle pacing (HBP) is unknown. We conducted a within-patient comparison of HBP, LBBAP, and biventricular pacing (BVP). METHODS AND RESULTS: Patients referred for CRT were recruited. We assessed electrical response using non-invasive mapping, and acute haemodynamic response using a high-precision haemodynamic protocol. Nineteen patients were recruited: 14 male, mean LVEF of 30%. Twelve had time for BVP measurements. All three modalities reduced total ventricular activation time (TVAT), (ΔTVATHBP -43 ± 14 ms and ΔTVATLBBAP -35 ± 20 ms vs. ΔTVATBVP -19 ± 30 ms, P = 0.03 and P = 0.1, respectively). HBP produced a significantly greater reduction in TVAT compared with LBBAP in all 19 patients (-46 ± 15 ms, -36 ± 17 ms, P = 0.03). His bundle pacing and LBBAP reduced left ventricular activation time (LVAT) more than BVP (ΔLVATHBP -43 ± 16 ms, P < 0.01 vs. BVP, ΔLVATLBBAP -45 ± 17 ms, P < 0.01 vs. BVP, ΔLVATBVP -13 ± 36 ms), with no difference between HBP and LBBAP (P = 0.65). Acute systolic blood pressure was increased by all three modalities. In the 12 with BVP, greater improvement was seen with HBP and LBBAP (6.4 ± 3.8 mmHg BVP, 8.1 ± 3.8 mmHg HBP, P = 0.02 vs. BVP and 8.4 ± 8.2 mmHg for LBBAP, P = 0.3 vs. BVP), with no difference between HBP and LBBAP (P = 0.8). CONCLUSION: HBP delivered better ventricular resynchronization than LBBAP because right ventricular activation was slower during LBBAP. But LBBAP was not inferior to HBP with respect to LV electrical resynchronization and acute haemodynamic response.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Masculino , Fascículo Atrioventricular , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/métodos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía/métodos , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Hemodinámica , Estimulación Cardíaca Artificial/métodosRESUMEN
AIMS: The response to high frequency stimulation (HFS) is used to locate putative sites of ganglionated plexuses (GPs), which are implicated in triggering atrial fibrillation (AF). To identify topological and immunohistochemical characteristics of presumed GP sites functionally identified by HFS. METHODS AND RESULTS: Sixty-three atrial sites were tested with HFS in four Langendorff-perfused porcine hearts. A 3.5 mm tip quadripolar ablation catheter was used to stimulate and deliver HFS to the left and right atrial epicardium, within the local atrial refractory period. Tissue samples from sites triggering atrial ectopy/AF (ET) sites and non-ET sites were stained with choline acetyltransferase (ChAT) and tyrosine hydroxylase (TH), for quantification of parasympathetic and sympathetic nerves, respectively. The average cross-sectional area (CSA) of nerves was also calculated. Histomorphometry of six ET sites (9.5%) identified by HFS evoking at least a single atrial ectopic was compared with non-ET sites. All ET sites contained ChAT-immunoreactive (ChAT-IR) and/or TH-immunoreactive nerves (TH-IR). Nerve density was greater in ET sites compared to non-ET sites (nerves/cm2: 162.3 ± 110.9 vs. 69.65 ± 72.48; P = 0.047). Overall, TH-IR nerves had a larger CSA than ChAT-IR nerves (µm2: 11 196 ± 35 141 vs. 2070 ± 5841; P < 0.0001), but in ET sites, TH-IR nerves were smaller than in non-ET sites (µm2: 6021 ± 14 586 vs. 25 254 ± 61 499; P < 0.001). CONCLUSIONS: ET sites identified by HFS contained a higher density of smaller nerves than non-ET sites. The majority of these nerves were within the atrial myocardium. This has important clinical implications for devising an effective therapeutic strategy for targeting autonomic triggers of AF.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Animales , Porcinos , Fibrilación Atrial/cirugía , Atrios Cardíacos , Miocardio , Sistema Nervioso Autónomo , Ablación por Catéter/métodosRESUMEN
AIMS: Left bundle branch pacing (LBBP) can deliver physiological left ventricular activation, but typically at the cost of delayed right ventricular (RV) activation. Right ventricular activation can be advanced through anodal capture, but there is uncertainty regarding the mechanism by which this is achieved, and it is not known whether this produces haemodynamic benefit. METHODS AND RESULTS: We recruited patients with LBBP leads in whom anodal capture eliminated the terminal R-wave in lead V1. Ventricular activation pattern, timing, and high-precision acute haemodynamic response were studied during LBBP with and without anodal capture. We recruited 21 patients with a mean age of 67 years, of whom 14 were males. We measured electrocardiogram timings and haemodynamics in all patients, and in 16, we also performed non-invasive mapping. Ventricular epicardial propagation maps demonstrated that RV septal myocardial capture, rather than right bundle capture, was the mechanism for earlier RV activation. With anodal capture, QRS duration and total ventricular activation times were shorter (116 ± 12 vs. 129 ± 14â ms, P < 0.01 and 83 ± 18 vs. 90 ± 15â ms, P = 0.01). This required higher outputs (3.6 ± 1.9 vs. 0.6 ± 0.2â V, P < 0.01) but without additional haemodynamic benefit (mean difference -0.2 ± 3.8â mmHg compared with pacing without anodal capture, P = 0.2). CONCLUSION: Left bundle branch pacing with anodal capture advances RV activation by stimulating the RV septal myocardium. However, this requires higher outputs and does not improve acute haemodynamics. Aiming for anodal capture may therefore not be necessary.
Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Masculino , Humanos , Anciano , Femenino , Estimulación Cardíaca Artificial/métodos , Sistema de Conducción Cardíaco , Hemodinámica , Ventrículos Cardíacos , Electrocardiografía/métodosRESUMEN
BACKGROUND: The use of left bundle branch area pacing (LBBAP) for bradycardia pacing and cardiac resynchronization is increasing, but implants are not always successful. We prospectively studied consecutive patients to determine whether septal scar contributes to implant failure. METHODS: Patients scheduled for bradycardia pacing or cardiac resynchronization therapy were prospectively enrolled. Recruited patients underwent preprocedural scar assessment by cardiac MRI with late gadolinium enhancement imaging. LBBAP was attempted using a lumenless lead (Medtronic 3830) via a transeptal approach. RESULTS: Thirty-five patients were recruited: 29 male, mean age 68 years, 10 ischemic, and 16 non-ischemic cardiomyopathy. Pacing indication was bradycardia in 26% and cardiac resynchronization in 74%. The lead was successfully deployed to the left ventricular septum in 30/35 (86%) and unsuccessful in the remaining 5/35 (14%). Septal late gadolinium enhancement was significantly less extensive in patients where left septal lead deployment was successful, compared those where it was unsuccessful (median 8%, IQR 2%-18% vs. median 54%, IQR 53%-57%, p < .001). CONCLUSIONS: The presence of septal scar appears to make it more challenging to deploy a lead to the left ventricular septum via the transeptal route. Additional implant tools or alternative approaches may be required in patients with extensive septal scar.
Asunto(s)
Tabique Interventricular , Humanos , Masculino , Anciano , Tabique Interventricular/diagnóstico por imagen , Bradicardia , Cicatriz , Medios de Contraste , GadolinioRESUMEN
BACKGROUND: Ganglionated plexuses (GPs) are implicated in atrial fibrillation (AF). Endocardial high-frequency stimulation (HFS) delivered within the local atrial refractory period can trigger ectopy and AF from specific GP sites (ET-GP). The aim of this study was to understand the role of ET-GP ablation in the treatment of AF. METHODS: Patients with paroxysmal AF indicated for ablation were recruited. HFS mapping was performed globally around the left atrium to identify ET-GP. ET-GP was defined as atrial ectopy or atrial arrhythmia triggered by HFS. All ET-GP were ablated, and PVs were left electrically connected. Outcomes were compared with a control group receiving pulmonary vein isolation (PVI). Patients were followed-up for 12 months with multiple 48-h Holter ECGs. Primary endpoint was ≥30 s AF/atrial tachycardia in ECGs. RESULTS: In total, 67 patients were recruited and randomized to ET-GP ablation (n = 39) or PVI (n = 28). In the ET-GP ablation group, 103 ± 28 HFS sites were tested per patient, identifying 21 ± 10 (20%) GPs. ET-GP ablation used 23.3 ± 4.1 kWs total radiofrequency (RF) energy per patient, compared with 55.7 ± 22.7 kWs in PVI (p = <.0001). Duration of procedure was 3.7 ± 1.0 and 3.3 ± 0.7 h in ET-GP ablation group and PVI, respectively (p = .07). Follow-up at 12 months showed that 61% and 49% were free from ≥30 s of AF/AT with PVI and ET-GP ablation respectively (log-rank p = .27). CONCLUSIONS: It is feasible to perform detailed global functional mapping with HFS and ablate ET-GP to prevent AF. This provides direct evidence that ET-GPs are part of the AF mechanism. The lower RF requirement implies that ET-GP targets the AF pathway more specifically.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Electrocardiografía Ambulatoria , Atrios Cardíacos , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: His bundle pacing (HBP) is an alternative to biventricular pacing (BVP) for delivering cardiac resynchronization therapy (CRT) in patients with heart failure and left bundle branch block (LBBB). It is not known whether ventricular activation times and patterns achieved by HBP are equivalent to intact conduction systems and not all patients with LBBB are resynchronized by HBP. OBJECTIVE: To compare activation times and patterns of His-CRT with BVP-CRT, LBBB and intact conduction systems. METHODS: In patients with LBBB, noninvasive epicardial mapping (ECG imaging) was performed during BVP and temporary HBP. Intrinsic activation was mapped in all subjects. Left ventricular activation times (LVAT) were measured and epicardial propagation mapping (EPM) was performed, to visualize epicardial wavefronts. Normal activation pattern and a normal LVAT range were determined from normal subjects. RESULTS: Forty-five patients were included, 24 with LBBB and LV impairment, and 21 with normal 12-lead ECG and LV function. In 87.5% of patients with LBBB, His-CRT successfully shortened LVAT by ≥10 ms. In 33.3%, His-CRT resulted in complete ventricular resynchronization, with activation times and patterns indistinguishable from normal subjects. EPM identified propagation discontinuity artifacts in 83% of patients with LBBB. This was the best predictor of whether successful resynchronization was achieved by HBP (logarithmic odds ratio, 2.19; 95% confidence interval, 0.07-4.31; p = .04). CONCLUSION: Noninvasive electrocardiographic mapping appears to identify patients whose LBBB can be resynchronized by HBP. In contrast to BVP, His-CRT may deliver the maximum potential ventricular resynchronization, returning activation times, and patterns to those seen in normal hearts.
Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Fascículo Atrioventricular , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/terapia , Electrocardiografía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Resultado del Tratamiento , Función Ventricular IzquierdaRESUMEN
BACKGROUND: Conventional mapping techniques during atrial fibrillation (AF) are difficult to apply because of cycle length irregularity. Mapping studies are usually restricted to short durations of AF in limited regions because of the laborious manual annotation of local activation time (LAT). The purpose of this study was to test an automated algorithm to map activation during AF, with comparable accuracy to manual annotation. METHODS: Left atrial (LA) mapping was performed using a 20-pole double loop catheter (AFocusII) in 30-second data segments from 16 patients. The new algorithm (RETRO-Mapping) was designed to detect wavefront propagation between electrodes, and display activating wavefronts on a two-dimensional representation of the catheter. Activation patterns were validated against their bipolar electrograms and with isochronal maps. The mapping protocol was approved by the research ethics committee (13/LO1169 and 14/LO1367). RESULTS: During AF, uniform wavefront activation direction (mean ± SD, degrees) from manually constructed isochronal maps was comparable to RETRO-Propagation Map (RETRO-PM) and RETRO-Automated Direction (RETRO-AD): 1 ± 6.9 for RETRO-PM; and 2 ± 6.6 for RETRO-AD. There was no significant difference in activation direction assigned to 1373 uniform wavefronts during AF when comparing RETRO-PM with RETRO-AD (Bland-Altman mean difference: -0.1 degrees; limits of agreement: -8.0 to 8.3; 95% CI -0.4 to 0.2; (r = 0.01) R2 = < 0.005; P = .77). CONCLUSION: We have developed and validated a new technique to map activation during AF. This technique shows comparable accuracy to that of conventional isochronal mapping with careful manual adjustment of LAT.
Asunto(s)
Algoritmos , Fibrilación Atrial/diagnóstico , Función del Atrio Izquierdo , Catéteres Cardíacos , Técnicas Electrofisiológicas Cardíacas/instrumentación , Atrios Cardíacos/fisiopatología , Procesamiento de Señales Asistido por Computador , Potenciales de Acción , Adulto , Anciano , Fibrilación Atrial/fisiopatología , Automatización , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de TiempoRESUMEN
INTRODUCTION: The ganglionated plexuses (GPs) of the intrinsic cardiac autonomic system are implicated in arrhythmogenesis. GP localization by stimulation of the epicardial fat pads to produce atrioventricular dissociating (AVD) effects is well described. We determined the anatomical distribution of the left atrial GPs that influence atrioventricular (AV) dissociation. METHODS AND RESULTS: High frequency stimulation was delivered through a Smart-Touch catheter in the left atrium of patients undergoing atrial fibrillation (AF) ablation. Three dimensional locations of points tested throughout the entire chamber were recorded on the CARTO™ system. Impact on the AV conduction was categorized as ventricular asystole, bradycardia, or no effect. CARTO maps were exported, registered, and transformed onto a reference left atrial geometry using a custom software, enabling data from multiple patients to be overlaid. In 28 patients, 2108 locations were tested and 283 sites (13%) demonstrated (AVD-GP) effects. There were 10 AVD-GPs (interquartile range, 11.5) per patient. Eighty percent (226) produced asystole and 20% (57) showed bradycardia. The distribution of the two groups was very similar. Highest probability of AVD-GPs (>20%) was identified in: inferoseptal portion (41%) and right inferior pulmonary vein base (30%) of the posterior wall, right superior pulmonary vein antrum (31%). CONCLUSION: It is feasible to map the entire left atrium for AVD-GPs before AF ablation. Aggregated data from multiple patients, producing a distribution probability atlas of AVD-GPs, identified three regions with a higher likelihood for finding AVD-GPs and these matched the histological descriptions. This approach could be used to better characterize the autonomic network.
Asunto(s)
Atlas como Asunto , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ganglios Autónomos/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Imagenología Tridimensional/métodos , Anciano , Ablación por Catéter/métodos , Femenino , Ganglios Autónomos/anatomía & histología , Atrios Cardíacos/anatomía & histología , Humanos , Masculino , Persona de Mediana Edad , ProbabilidadRESUMEN
AIMS: Complex ablation procedures are supported by accurate representation of an increasing variety of electrophysiological and imaging data within electroanatomic mapping systems (EMS). This study aims to develop a novel method for representing multiple complementary datasets on a single cardiac chamber model. Validation of the system and its application to both atrial and ventricular arrhythmias is examined. METHODS AND RESULTS: Dot mapping was conceived to display multiple datasets by utilizing quantitative surface shading to represent one dataset and finely spaced dots to represent others. Dot positions are randomized within triangular (surface meshes) or tetrahedral (volumetric meshes) simplices making the approach directly transferrable to contemporary EMS. Test data representing uniform electrical activation (n = 10) and focal scarring (n = 10) were used to test dot mapping data perception accuracy. User experience of dot mapping with atrial and ventricular clinical data is evaluated. Dot mapping ensured constant screen dot density for regions of uniform dataset values, regardless of user manipulation of the cardiac chamber. Perception accuracy of dot mapping was equivalent to colour mapping for both propagation direction (1.5 ± 1.8 vs. 4.8 ± 5.3°, P = 0.24) and focal source localization (1.1 ± 0.7 vs. 1.4 ± 0.5 mm, P = 0.88). User acceptance testing revealed equivalent diagnostic accuracy and display fidelity when compared with colour mapping. CONCLUSION: Dot mapping provides the unique ability to display multiple datasets from multiple sources on a single cardiac chamber model. The visual combination of multiple datasets may facilitate interpretation of complex electrophysiological and imaging data.
Asunto(s)
Potenciales de Acción , Arritmias Cardíacas/diagnóstico , Gráficos por Computador , Técnicas Electrofisiológicas Cardíacas , Sistema de Conducción Cardíaco/fisiopatología , Imagenología Tridimensional , Procesamiento de Señales Asistido por Computador , Algoritmos , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Sistema de Conducción Cardíaco/diagnóstico por imagen , Frecuencia Cardíaca , Humanos , Imagen por Resonancia Magnética , Modelos Cardiovasculares , Modelación Específica para el Paciente , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de TiempoRESUMEN
AIMS: To provide a comprehensive histopathological validation of cardiac magnetic resonance (CMR) and endocardial voltage mapping of acute and chronic atrial ablation injury. METHODS AND RESULTS: 16 pigs underwent pre-ablation T2-weighted (T2W) and late gadolinium enhancement (LGE) CMR and high-density voltage mapping of the right atrium (RA) and both were repeated after intercaval linear radiofrequency ablation. Eight pigs were sacrificed following the procedure for pathological examination. A further eight pigs were recovered for 8 weeks, before chronic CMR, repeat RA voltage mapping and pathological examination. Signal intensity (SI) thresholds from 0 to 15 SD above a reference SI were used to segment the RA in CMR images and segmentations compared with real lesion volumes. The SI thresholds that best approximated histological volumes were 2.3 SD for LGE post-ablation, 14.5 SD for T2W post-ablation and 3.3 SD for LGE chronically. T2-weighted chronically always underestimated lesion volume. Acute histology showed transmural injury with coagulative necrosis. Chronic histology showed transmural fibrous scar. The mean voltage at the centre of the ablation line was 3.3 mV pre-ablation, 0.6 mV immediately post-ablation, and 0.3 mV chronically. CONCLUSION: This study presents the first histopathological validation of CMR and endocardial voltage mapping to define acute and chronic atrial ablation injury, including SI thresholds that best match histological lesion volumes. An understanding of these thresholds may allow a more informed assessment of the underlying atrial substrate immediately after ablation and before repeat catheter ablation for atrial arrhythmias.
Asunto(s)
Ablación por Catéter/efectos adversos , Electrodiagnóstico/métodos , Lesiones Cardíacas/patología , Angiografía por Resonancia Magnética/métodos , Enfermedad Aguda , Animales , Técnicas de Imagen Cardíaca/métodos , Enfermedad Crónica , Medios de Contraste , Femenino , Atrios Cardíacos/patología , Compuestos Organometálicos , Porcinos , Porcinos EnanosRESUMEN
BACKGROUND: Recurrent ventricular tachycardia (VT) can be treated by substrate modification of the myocardial scar by catheter ablation during sinus rhythm without VT induction. Better defining this arrhythmic substrate could help improve outcome and reduce ablation burden. OBJECTIVE: The study aimed to limit ablation within postinfarction scar to conduction channels within the scar to reduce VT recurrence. METHODS: Patients undergoing catheter ablation for recurrent implantable cardioverter-defibrillator therapy for postinfarction VT were recruited at 5 centers. Left ventricular maps were collected on CARTO using a Pentaray catheter. Ripple mapping was used to categorize infarct scar potentials (SPs) by timing. Earliest SPs were ablated sequentially until there was loss of the terminal SPs without their direct ablation. The primary outcome measure was sustained VT episodes as documented by device interrogations at 1 year, which was compared with VT episodes in the year before ablation. RESULTS: The study recruited 50 patients (mean left ventricular ejection fraction, 33% ± 9%), and 37 patients (74%) met the channel ablation end point with successful loss of latest SPs without direct ablation. There were 16 recurrences during 1-year follow-up. There was a 90% reduction in VT burden from 30.2 ± 53.9 to 3.1 ± 7.5 (P < .01) per patient, with a concomitant 88% reduction in appropriate shocks from 2.1 ± 2.7 to 0.2 ± 0.9 (P < .01). There were 8 deaths during follow-up. Those who met the channel ablation end point had no significant difference in mortality, recurrence, or VT burden but had a significantly lower ablation burden of 25.7 ± 4.2 minutes vs 39.9 ± 6.1 minutes (P = .001). CONCLUSION: Scar channel ablation is feasible by ripple mapping and can be an alternative to more extensive substrate modification techniques.
RESUMEN
BACKGROUND: Ventricular tachycardia (VT) reduces cardiac output through high heart rates, loss of atrioventricular synchrony, and loss of ventricular synchrony. We studied the contribution of each mechanism and explored the potential therapeutic utility of His bundle pacing to improve cardiac output during VT. METHODS: Study 1 aimed to improve the understanding of mechanisms of harm during VT (using pacing simulated VT). In 23 patients with left ventricular impairment, we recorded continuous ECG and beat-by-beat blood pressure measurements. We assessed the hemodynamic impact of heart rate and restoration of atrial and biventricular synchrony. Study 2 investigated novel pacing interventions during clinical VT by evaluating the hemodynamic effects of His bundle pacing at 5 bpm above the VT rate in 10 patients. RESULTS: In Study 1, at progressively higher rates of simulated VT, systolic blood pressure declined: at rates of 125, 160, and 190 bpm, -22.2%, -42.0%, and -58.7%, respectively (ANOVA p < 0.0001). Restoring atrial synchrony alone had only a modest beneficial effect on systolic blood pressure (+ 3.6% at 160 bpm, p = 0.2117), restoring biventricular synchrony alone had a greater effect (+ 9.1% at 160 bpm, p = 0.242), and simultaneously restoring both significantly increased systolic blood pressure (+ 31.6% at 160 bpm, p = 0.0003). In Study 2, the mean rate of clinical VT was 143 ± 21 bpm. His bundle pacing increased systolic blood pressure by + 14.2% (p = 0.0023). In 6 of 10 patients, VT terminated with His bundle pacing. CONCLUSIONS: Restoring atrial and biventricular synchrony improved hemodynamic function in simulated and clinical VT. Conduction system pacing could improve VT tolerability and treatment.
Asunto(s)
Gasto Cardíaco , Estimulación Cardíaca Artificial , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/terapia , Masculino , Femenino , Anciano , Estimulación Cardíaca Artificial/métodos , Gasto Cardíaco/fisiología , Resultado del Tratamiento , Electrocardiografía , Persona de Mediana Edad , Fascículo Atrioventricular/fisiopatología , Frecuencia Cardíaca/fisiología , Sistema de Conducción Cardíaco/fisiopatologíaRESUMEN
BACKGROUND: Three-dimensional (3D) mapping of the ventricular conduction system is challenging. OBJECTIVE: The purpose of this study was to use ripple mapping to distinguish conduction system activation to that of adjacent myocardium in order to characterize the conduction system in the postinfarct left ventricle (LV). METHODS: High-density mapping (PentaRay, CARTO) was performed during normal rhythm in patients undergoing ventricular tachycardia ablation. Ripple maps were viewed from the end of the P wave to QRS onset in 1-ms increments. Clusters of >3 ripple bars were interrogated for the presence of Purkinje potentials, which were tagged on the 3D geometry. Repeating this process allowed conduction system delineation. RESULTS: Maps were reviewed in 24 patients (mean 3112 ± 613 points). There were 150.9 ± 24.5 Purkinje potentials per map, at the left posterior fascicle (LPF) in 22 patients (92%) and at the left anterior fascicle (LAF) in 15 patients (63%). The LAF was shorter (41.4 vs 68.8 mm; P = .0005) and activated for a shorter duration (40.6 vs 64.9 ms; P = .002) than the LPF. Fourteen of 24 patients had left bundle branch block (LBBB), with 11 of 14 (78%) having Purkinje potential-associated breakout. There were fewer breakouts from the conduction system during LBBB (1.8 vs 3.4; 1.6 ± 0.6; P = .039) and an inverse correlation between breakout sites and QRS duration (P = .0035). CONCLUSION: We applied ripple mapping to present a detailed electroanatomic characterization of the conduction system in the postinfarct LV. Patients with broader QRS had fewer LV breakout sites from the conduction system. However, there was 3D mapping evidence of LV breakout from an intact conduction system in the majority of patients with LBBB.
Asunto(s)
Ablación por Catéter , Sistema de Conducción Cardíaco , Ventrículos Cardíacos , Infarto del Miocardio , Taquicardia Ventricular , Humanos , Masculino , Femenino , Sistema de Conducción Cardíaco/fisiopatología , Persona de Mediana Edad , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Taquicardia Ventricular/fisiopatología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiología , Ablación por Catéter/métodos , Infarto del Miocardio/fisiopatología , Infarto del Miocardio/complicaciones , Electrocardiografía , Ramos Subendocárdicos/fisiopatología , Anciano , Imagenología Tridimensional , Mapeo del Potencial de Superficie Corporal/métodosRESUMEN
INTRODUCTION: Entrainment criteria for the diagnosis of reentrant atrial tachycardia can be difficult to apply and cannot detect double-loop reentry. We sought to develop and clinically test a new criterion for the diagnosis of single- and double-loop reentry. METHODS AND RESULTS: (1) Proposed criterion: after sequential overdrive pacing at 2 different locations and assessing the first ensuing beats of tachycardia, the difference in activation time recorded between 2 appropriate stationary positions changes by 1 or 2 tachycardia cycle lengths; a change of 2 tachycardia cycle lengths usually indicates double-loop reentry rather than only a single-loop. (2) Clinical testing: multiple overdrive pacing maneuvers were undertaken and analyzed in 5 patients with common flutter (single-loop reentry). In total, 23 pairs of overdrive pacing maneuvers were performed using electrodes in the coronary sinus and a distribution of positions in the right atrium. In 22/23 pairs of maneuvers, the change in Activation Difference was within 2.6 ± 12.4 milliseconds of the tachycardia cycle length, confirming single loop reentry. For double-loop reentry, the literature was reviewed and 3 cases of double-loop reentry were identified with sufficient data. In all of these cases, double-loop reentry was detected and also the zone containing the common isthmus was identified. CONCLUSION: The proposed criterion can diagnose single- and double-loop reentry atrial tachycardia using intracardiac recordings from any pair of well separated positions. The criterion does not require precise electrode placement or extensive activation mapping.
Asunto(s)
Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Aleteo Atrial/fisiopatología , Electrocardiografía , Humanos , Matemática , Modelos Teóricos , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatologíaRESUMEN
BACKGROUND: Community-based management by heart failure specialist nurses (HFSNs) is key to improving self-care in heart failure with reduced ejection fraction. Remote monitoring (RM) can aid nurse-led management, but in the literature, user feedback evaluation is skewed in favor of the patient rather than nursing user experience. Furthermore, the ways in which different groups use the same RM platform at the same time are rarely directly compared in the literature. We present a balanced semantic analysis of user feedback from patient and nurse perspectives of Luscii, a smartphone-based RM strategy combining self-measurement of vital signs, instant messaging, and e-learning. OBJECTIVE: This study aims to (1) evaluate how patients and nurses use this type of RM (usage type), (2) evaluate patients' and nurses' user feedback on this type of RM (user experience), and (3) directly compare the usage type and user experience of patients and nurses using the same type of RM platform at the same time. METHODS: We performed a retrospective usage type and user experience evaluation of the RM platform from the perspective of both patients with heart failure with reduced ejection fraction and the HFSNs using the platform to manage them. We conducted semantic analysis of written patient feedback provided via the platform and a focus group of 6 HFSNs. Additionally, as an indirect measure of tablet adherence, self-measured vital signs (blood pressure, heart rate, and body mass) were extracted from the RM platform at onboarding and 3 months later. Paired 2-tailed t tests were used to evaluate differences between mean scores across the 2 timepoints. RESULTS: A total of 79 patients (mean age 62 years; 35%, 28/79 female) were included. Semantic analysis of usage type revealed extensive, bidirectional information exchange between patients and HFSNs using the platform. Semantic analysis of user experience demonstrates a range of positive and negative perspectives. Positive impacts included increased patient engagement, convenience for both user groups, and continuity of care. Negative impacts included information overload for patients and increased workload for nurses. After the patients used the platform for 3 months, they showed significant reductions in heart rate (P=.004) and blood pressure (P=.008) but not body mass (P=.97) compared with onboarding. CONCLUSIONS: Smartphone-based RM with messaging and e-learning facilitates bilateral information sharing between patients and nurses on a range of topics. Patient and nurse user experience is largely positive and symmetrical, but there are possible negative impacts on patient attention and nurse workload. We recommend RM providers involve patient and nurse users in platform development, including recognition of RM usage in nursing job plans.
RESUMEN
Background: Getting the most value from expert clinicians' limited labelling time is a major challenge for artificial intelligence (AI) development in clinical imaging. We present a novel method for ground-truth labelling of cardiac magnetic resonance imaging (CMR) image data by leveraging multiple clinician experts ranking multiple images on a single ordinal axis, rather than manual labelling of one image at a time. We apply this strategy to train a deep learning (DL) model to classify the anatomical position of CMR images. This allows the automated removal of slices that do not contain the left ventricular (LV) myocardium. Methods: Anonymised LV short-axis slices from 300 random scans (3,552 individual images) were extracted. Each image's anatomical position relative to the LV was labelled using two different strategies performed for 5 hours each: (I) 'one-image-at-a-time': each image labelled according to its position: 'too basal', 'LV', or 'too apical' individually by one of three experts; and (II) 'multiple-image-ranking': three independent experts ordered slices according to their relative position from 'most-basal' to 'most apical' in batches of eight until each image had been viewed at least 3 times. Two convolutional neural networks were trained for a three-way classification task (each model using data from one labelling strategy). The models' performance was evaluated by accuracy, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Results: After excluding images with artefact, 3,323 images were labelled by both strategies. The model trained using labels from the 'multiple-image-ranking strategy' performed better than the model using the 'one-image-at-a-time' labelling strategy (accuracy 86% vs. 72%, P=0.02; F1-score 0.86 vs. 0.75; ROC AUC 0.95 vs. 0.86). For expert clinicians performing this task manually the intra-observer variability was low (Cohen's κ=0.90), but the inter-observer variability was higher (Cohen's κ=0.77). Conclusions: We present proof of concept that, given the same clinician labelling effort, comparing multiple images side-by-side using a 'multiple-image-ranking' strategy achieves ground truth labels for DL more accurately than by classifying images individually. We demonstrate a potential clinical application: the automatic removal of unrequired CMR images. This leads to increased efficiency by focussing human and machine attention on images which are needed to answer clinical questions.
RESUMEN
BACKGROUND: Despite effective therapies, the economic burden of heart failure with reduced ejection fraction (HFrEF) is driven by frequent hospitalizations. Treatment optimization and admission avoidance rely on frequent symptom reviews and monitoring of vital signs. Remote monitoring (RM) aims to prevent admissions by facilitating early intervention, but the impact of noninvasive, smartphone-based RM of vital signs on secondary health care use and costs in the months after a new diagnosis of HFrEF is unknown. OBJECTIVE: The purpose of this study is to conduct a secondary care health use and health-economic evaluation for patients with HFrEF using smartphone-based noninvasive RM and compare it with matched controls receiving usual care without RM. METHODS: We conducted a retrospective study of 2 cohorts of newly diagnosed HFrEF patients, matched 1:1 for demographics, socioeconomic status, comorbidities, and HFrEF severity. They are (1) the RM group, with patients using the RM platform for >3 months and (2) the control group, with patients referred before RM was available who received usual heart failure care without RM. Emergency department (ED) attendance, hospital admissions, outpatient use, and the associated costs of this secondary care activity were extracted from the Discover data set for a 3-month period after diagnosis. Platform costs were added for the RM group. Secondary health care use and costs were analyzed using Kaplan-Meier event analysis and Cox proportional hazards modeling. RESULTS: A total of 146 patients (mean age 63 years; 42/146, 29% female) were included (73 in each group). The groups were well-matched for all baseline characteristics except hypertension (P=.03). RM was associated with a lower hazard of ED attendance (hazard ratio [HR] 0.43; P=.02) and unplanned admissions (HR 0.26; P=.02). There were no differences in elective admissions (HR 1.03, P=.96) or outpatient use (HR 1.40; P=.18) between the 2 groups. These differences were sustained by a univariate model controlling for hypertension. Over a 3-month period, secondary health care costs were approximately 4-fold lower in the RM group than the control group, despite the additional cost of RM itself (mean cost per patient GBP £465, US $581 vs GBP £1850, US $2313, respectively; P=.04). CONCLUSIONS: This retrospective cohort study shows that smartphone-based RM of vital signs is feasible for HFrEF. This type of RM was associated with an approximately 2-fold reduction in ED attendance and a 4-fold reduction in emergency admissions over just 3 months after a new diagnosis with HFrEF. Costs were significantly lower in the RM group without increasing outpatient demand. This type of RM could be adjunctive to standard care to reduce admissions, enabling other resources to help patients unable to use RM.