1.
J Cardiovasc Electrophysiol ; 34(11): 2225-2232, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37702135

RESUMEN

INTRODUCTION: The need for pacemaker is a common complication after transcatheter aortic valve replacement (TAVR). We previously described the Emory Risk Score (ERS) to predict the need for new pacemaker implant (PPM) after TAVR. Metrics included in the score are a history of syncope, pre-existing RBBB, QRS duration ≥140 ms, and prosthesis oversizing ≥16%. To prospectively validate the previously described risk score. METHODS: We prospectively evaluated all patients without pre-existing pacemakers, ICD, or pre-existing indications for pacing undergoing TAVR with the Edwards SAPIEN 3 prosthesis at our institution from March 2019 to December 2020 (n = 661). Patients were scored prospectively; however, results were blinded from clinical decision-making. The primary endpoint was PPM at 30 days after TAVR. Performance of the ERS was evaluated using logistic regression, a calibration curve to prior performance, and receiver operating characteristic (ROC) analysis. RESULTS: A total of 48 patients (7.3%) had PPM after TAVR. A higher ERS predicted an increased likelihood of PPM (OR 2.61, 95% CI: 2.05-3.25 per point, p < 0.001). There was good correlation between observed and expected values on the calibration curve (slope = 1.04, calibration at large = 0.001). The area under the ROC curve was 0.81 (95% CI [0.74-0.88], p < 0.001). CONCLUSIONS: The ERS prospectively predicted the need for PPM in a serial, real-world cohort of patients undergoing TAVR with a balloon-expandable prosthesis, confirming findings previously described in retrospective cohorts. Notably, the prospective performance of the score was comparable with that of the initial cohorts. The risk score could serve as a framework for preprocedural risk stratification for PPM after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Factores de Riesgo , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
2.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
3.
J ECT ; 38(1): 2-9, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34699395

RESUMEN

ABSTRACT: Electroconvulsive therapy (ECT) remains stigmatized in the broader medical community because of misunderstandings about treatment procedures, mortality rates, and cardiovascular complications. Electroconvulsive therapy causes periprocedural hemodynamic variability because of the surges in parasympathetic and sympathetic nervous systems after the administration of the electrical charge. Patients experience an increase in cardiac workload, which is potentially dangerous for patients with preexisting heart disease. Several findings suggest that cardiac complications occur most frequently in patients with underlying cardiovascular disease. We describe the cardiovascular complications that may result from ECT treatment and offer insight on how to mitigate these concerns if they occur. PubMed was queried using terms "electroconvulsive therapy" and "cardiovascular adverse effects." A table is provided with the common cardiovascular side effects of ECT and the most recent evidence-based treatment strategies to manage them. Generally, ECT is a safe procedure in which complications are minor and manageable. Most major complications caused by ECT are related to the cardiovascular system; however, with an appropriate pre-ECT evaluation and a comprehensive multidisciplinary team approach, the cardiovascular complications can be well managed and minimized. Providing proper cardiac clearance can prevent cardiac complications and provide timely care to treatment-resistant populations who are at risk for excessive morbidity and suicide.


Asunto(s)
Enfermedades Cardiovasculares , Sistema Cardiovascular , Terapia Electroconvulsiva , Enfermedades Cardiovasculares/etiología , Terapia Electroconvulsiva/efectos adversos , Hemodinámica , Humanos
4.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Catheter Cardiovasc Interv ; 95(6): 1193-1194, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32421242

RESUMEN

Transcatheter aortic valve replacement (TAVR) is an acceptable treatment alternative to surgical aortic valve replacement in selected patients with a bicuspid aortic valve. TAVR appears to have acceptable mid-term outcomes in patients with bicuspid aortic stenosis. A large-scale, randomized, clinical trial is necessary to better define the role of TAVR for patients with bicuspid aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Válvula Aórtica Bicúspide , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Constricción Patológica , Composición Familiar , Humanos , Pacientes , Resultado del Tratamiento
6.
Catheter Cardiovasc Interv ; 95(7): 1334-1335, 2020 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-32537863

RESUMEN

Seven percent of patients (with no history of intraventricular conduction abnormalities) experienced intraprocedural high-degree Atrioventricular (AV)/complete heart block. High-degree/complete heart block was persistent in 64% of patients who developed significant intraprocedural intraventricular conduction abnormalities. Ninety-seven percent of patients with persistent high-degree AV/complete block ultimately required pacemaker implantation.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Bloqueo Atrioventricular/terapia , Humanos , Resultado del Tratamiento
7.
Circulation ; 137(20): 2166-2178, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29760227

RESUMEN

Socioeconomic status (SES) has a measurable and significant effect on cardiovascular health. Biological, behavioral, and psychosocial risk factors prevalent in disadvantaged individuals accentuate the link between SES and cardiovascular disease (CVD). Four measures have been consistently associated with CVD in high-income countries: income level, educational attainment, employment status, and neighborhood socioeconomic factors. In addition, disparities based on sex have been shown in several studies. Interventions targeting patients with low SES have predominantly focused on modification of traditional CVD risk factors. Promising approaches are emerging that can be implemented on an individual, community, or population basis to reduce disparities in outcomes. Structured physical activity has demonstrated effectiveness in low-SES populations, and geomapping may be used to identify targets for large-scale programs. Task shifting, the redistribution of healthcare management from physician to nonphysician providers in an effort to improve access to health care, may have a role in select areas. Integration of SES into the traditional CVD risk prediction models may allow improved management of individuals with high risk, but cultural and regional differences in SES make generalized implementation challenging. Future research is required to better understand the underlying mechanisms of CVD risk that affect individuals of low SES and to determine effective interventions for patients with high risk. We review the current state of knowledge on the impact of SES on the incidence, treatment, and outcomes of CVD in high-income societies and suggest future research directions aimed at the elimination of these adverse factors, and the integration of measures of SES into the customization of cardiovascular treatment.


Asunto(s)
Enfermedades Cardiovasculares/patología , Clase Social , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/psicología , Escolaridad , Ejercicio Físico , Conductas Relacionadas con la Salud , Humanos , Renta , Factores de Riesgo
8.
Catheter Cardiovasc Interv ; 94(6): 827-828, 2019 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-31737989

RESUMEN

There appears to be lower mortality in patients treated with MitraClip + OMT compared to OMT alone. There appears to be a lower rate of hospitalization in patients treated with MitraClip + OMT compared to OMT alone. There are only two randomized controlled trials (with discordant results) evaluating MitraClip + OMT compared to OMT alone.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 93(7): 1352-1353, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-31172677

RESUMEN

In a multivariate model, the drop-in platelet count (DPC) was significantly higher in patients treated with a balloon expandable valve (BEV) than a self-expandable valve (SEV) (36.3% ± 15.1% vs. 27.7% ± 14.4%, p < .001). In a univariate model, a higher DPC post-transcatheter aortic valve replacement was observed in patients requiring alternate access and lower contrast volume. The platelet count nadir was nearly a day later in patients implanted with a BEV compared with an SEV. At 30 days, there was a higher rate of adverse events and mortality in patients with a high DPC. At 1 year, there was no significant difference in mortality rates between the high DPC group and the low DPC group.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Trombocitopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento
10.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38573257

RESUMEN

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Complicaciones Posoperatorias , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Incidencia , Retratamiento
11.
J Am Coll Cardiol ; 83(14): 1257-1272, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38471643

RESUMEN

BACKGROUND: Left ventricular outflow tract (LVOT) obstruction is a source of morbidity in hypertrophic cardiomyopathy (HCM) and a life-threatening complication of transcatheter mitral valve replacement (TMVR) and transcatheter aortic valve replacement (TAVR). Available surgical and transcatheter approaches are limited by high surgical risk, unsuitable septal perforators, and heart block requiring permanent pacemakers. OBJECTIVES: The authors report the initial experience of a novel transcatheter electrosurgical procedure developed to mimic surgical myotomy. METHODS: We used septal scoring along midline endocardium (SESAME) to treat patients, on a compassionate basis, with symptomatic LVOT obstruction or to create space to facilitate TMVR or TAVR. RESULTS: In this single-center retrospective study between 2021 and 2023, 76 patients underwent SESAME. In total, 11 (14%) had classic HCM, and the remainder underwent SESAME to facilitate TMVR or TAVR. All had technically successful SESAME myocardial laceration. Measures to predict post-TMVR LVOT significantly improved (neo-LVOT 42 mm2 [Q1-Q3: 7-117 mm2] to 170 mm2 [Q1-Q3: 95-265 mm2]; P < 0.001; skirt-neo-LVOT 169 mm2 [Q1-Q3: 153-193 mm2] to 214 mm2 [Q1-Q3: 180-262 mm2]; P < 0.001). Among patients with HCM, SESAME significantly decreased invasive LVOT gradients (resting: 54 mm Hg [Q1-Q3: 40-70 mm Hg] to 29 mm Hg [Q1-Q3: 12-36 mm Hg]; P = 0.023; provoked 146 mm Hg [Q1-Q3: 100-180 mm Hg] to 85 mm Hg [Q1-Q3: 40-120 mm Hg]; P = 0.076). A total of 74 (97.4%) survived the procedure. Five experienced 3 of 76 (3.9%) iatrogenic ventricular septal defects that did not require repair and 3 of 76 (3.9%) ventricular free wall perforations. Neither occurred in patients treated for HCM. Permanent pacemakers were required in 4 of 76 (5.3%), including 2 after concomitant TAVR. Lacerations were stable and did not propagate after SESAME (remaining septum: 5.9 ± 3.3 mm to 6.1 ± 3.2 mm; P = 0.8). CONCLUSIONS: With further experience, SESAME may benefit patients requiring septal reduction therapy for obstructive hypertrophic cardiomyopathy as well as those with LVOT obstruction after heart valve replacement, and/or can help facilitate transcatheter valve implantation.


Asunto(s)
Cardiomiopatía Hipertrófica , Implantación de Prótesis de Válvulas Cardíacas , Miotomía , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento , Cardiomiopatía Hipertrófica/complicaciones , Miotomía/efectos adversos
12.
J Thorac Cardiovasc Surg ; 166(4): e130-e141, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37086238

RESUMEN

BACKGROUND: Leaflet thrombosis after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) may be caused by blood flow stagnation in the native and neosinus regions. To date, aortic leaflet laceration has been used to mitigate coronary obstruction following TAVR; however, its influence on the fluid mechanics of the native and neosinus regions is poorly understood. This in vitro study compared the flow velocities and flow patterns in the setting of SAVR vs TAVR with and without aortic leaflet lacerations. METHODS: Two valves, (23-mm Perimount and 26-mm SAPIEN 3; Edwards Lifesciences) were studied in a validated mock flow loop under physiologic conditions. Neosinus and native sinus fluid mechanics were quantified using particle image velocimetry in the left and noncoronary cusp, with an increasing number of aortic leaflets lacerated or removed. RESULTS: Across all conditions, SAVR had the highest average sinus and neosinus velocities, and this value was used as a reference to compare against the TAVR conditions. With an increasing number of leaflets lacerated or removed with TAVR, the average sinus and neosinus velocities increased from 25% to 70% of SAVR flow (100%). Diastolic velocities were substantially augmented by leaflet laceration. Also, the shorter frame of the SAVR led to higher flow velocities compared with the longer frame of the TAVR, even after complete leaflet removal. CONCLUSIONS: Leaflet laceration augmented TAVR native and neosinus flow fields, approaching that of SAVR. These findings may have potential clinical implications for the use of single or multiple leaflet lacerations to reduce leaflet thrombosis and thus potentially improve TAVR durability.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Laceraciones , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Laceraciones/complicaciones , Laceraciones/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Trombosis/etiología , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
13.
Cardiovasc Revasc Med ; 53S: S176-S179, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35879191

RESUMEN

A cardiogenic shock patient with a history of a surgical mitral valve replacement presented to the hospital with critical mitral stenosis with thickening of prosthetic valve leaflets and thrombus in left atrial appendage. We considered TMVR inside of the degenerated bioprosthetic valve. However, there were two concerns during TMVR based on multimodality imaging assessment: 1) LVOT obstruction due to the surgical bioprosthetic leaflet, 2) stroke due to left atrial appendage thrombus. We performed TMVR with LAMPOON (laceration of the anterior leaflet of the surgical valve to prevent left ventricular outflow tract obstruction) for the bioprosthesis using cerebral protection. While the LAMPOON procedure has developed to prevent LVOT obstruction by the native anterior mitral leaflet during transcatheter mitral valve-in-ring or valve-in-mitral annular calcification, this is the first case that illustrates its use for mitral valve-in-valve replacement.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Trombosis , Obstrucción del Flujo Ventricular Externo , Humanos , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento
14.
EuroIntervention ; 19(4): e330-e339, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37067193

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown. AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut. METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions. RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth. CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estudios de Factibilidad , Diseño de Prótesis , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
15.
JACC Cardiovasc Interv ; 16(4): 415-425, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858660

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR)-related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies. OBJECTIVES: This study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis. METHODS: Preprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort. RESULTS: Sixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right. CONCLUSIONS: A novel computed tomography-based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Mortalidad Hospitalaria , Resultado del Tratamiento , Corazón
16.
Cardiovasc Revasc Med ; 40S: 218-221, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34952823

RESUMEN

Saphenous vein graft (SVG) aneurysms are rare but can be associated with significant morbidity and mortality. This case illustrates a percutaneous approach for the management of SVG aneurysm with a fistulous connection to the right atrium.


Asunto(s)
Aneurisma , Vena Safena , Aneurisma/diagnóstico por imagen , Aneurisma/etiología , Aneurisma/cirugía , Puente de Arteria Coronaria/efectos adversos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Humanos , Vena Safena/diagnóstico por imagen , Vena Safena/trasplante
17.
Eur Heart J Cardiovasc Imaging ; 23(5): 650-662, 2022 04 18.
Artículo en Inglés | MEDLINE | ID: mdl-34009283

RESUMEN

AIMS: To characterize the dynamic nature of the left ventricular outflow tract (LVOT) geometry and flow rate in patients following transcatheter mitral valve replacement (TMVR) with anterior leaflet laceration (LAMPOON) and derive insights to help guide future patient selection. METHODS AND RESULTS: Time-resolved LVOT geometry and haemodynamics were analysed with post-procedure computed tomography and echocardiography in subjects (N = 19) from the LAMPOON investigational device exemption trial. A novel post hoc definition for LVOT obstruction was employed to account for systolic flow rate and quality of life improvement [obstruction was defined as LVOT gradient >30 mmHg or LVOT effective orifice area (EOA) ≤1.15 cm2]. The neo-LVOT and skirt neo-LVOT were observed to vary substantially in area throughout systole (64 ± 27% and 25 ± 14% change in area, respectively). The peak systolic flow rate occurred most commonly just prior to mid-systole, while minimum neo-LVOT (and skirt neo-LVOT) area occurred most commonly in early-diastole. Subjects with LVOT obstruction (n = 5) had smaller skirt neo-LVOT values across systole. Optimal thresholds for skirt neo-LVOT area were phase-specific (260, 210, 200, and 180 mm2 for early-systole, peak flow, mid-systole, and end-systole, respectively). CONCLUSION: The LVOT geometry and flow rate exhibit dynamic characteristics following TMVR with LAMPOON. Subjects with LVOT obstruction had smaller skirt neo-LVOT areas across systole. The authors recommend the use of phase-specific threshold values for skirt neo-LVOT area to guide future patient selection for this procedure. LVOT EOA is a 'flow-independent' metric which has the potential to aid in characterizing LVOT obstruction severity.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo Ventricular Externo , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía
18.
JACC Cardiovasc Interv ; 15(9): 965-975, 2022 05 09.
Artículo en Inglés | MEDLINE | ID: mdl-35512920

RESUMEN

OBJECTIVES: The aim of this study was to compare transcaval and transaxillary artery access for transcatheter aortic valve replacement (TAVR) at experienced medical centers in contemporary practice. BACKGROUND: There are no systematic comparisons of transcaval and transaxillary TAVR access routes. METHODS: Eight experienced centers contributed local data collected for the STS/ACC TVT Registry (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry) between 2017 and 2020. Outcomes after transcaval and axillary/subclavian (transaxillary) access were adjusted for baseline imbalances using doubly robust (inverse propensity weighting plus regression) estimation and compared. RESULTS: Transcaval access was used in 238 procedures and transaxillary access in 106; for comparison, transfemoral access was used in 7,132 procedures. Risk profiles were higher among patients selected for nonfemoral access but similar among patients requiring transcaval and transaxillary access. Stroke and transient ischemic attack were 5-fold less common after transcaval than transaxillary access (2.5% vs 13.2%; OR: 0.20; 95% CI: 0.06-0.72; P = 0.014) compared with transfemoral access (1.7%). Major and life-threatening bleeding (Valve Academic Research Consortium 3 ≥ type 2) were comparable (10.0% vs 13.2%; OR: 0.66; 95% CI: 0.26-1.66; P = 0.38) compared with transfemoral access (3.5%), as was blood transfusion (19.3% vs 21.7%; OR: 1.07; 95% CI: 0.49-2.33; P = 0.87) compared with transfemoral access (7.1%). Vascular complications, intensive care unit and hospital length of stay, and survival were similar between transcaval and transaxillary access. More patients were discharged directly home and without stroke or transient ischemic attack after transcaval than transaxillary access (87.8% vs 62.3%; OR: 5.19; 95% CI: 2.45-11.0; P < 0.001) compared with transfemoral access (90.3%). CONCLUSIONS: Patients undergoing transcaval TAVR had lower rates of stroke and similar bleeding compared with transaxillary access in a contemporary experience from 8 US centers. Both approaches had more complications than transfemoral access. Transcaval TAVR access may offer an attractive option.


Asunto(s)
Estenosis de la Válvula Aórtica , Ataque Isquémico Transitorio , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento , Estados Unidos
19.
JACC Cardiovasc Interv ; 15(12): 1249-1263, 2022 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-35738745

RESUMEN

BACKGROUND: Transcatheter mitral valve repair is beneficial in patients with mitral regurgitation (MR), left ventricular dysfunction, and persistent symptoms despite maximally tolerated medical therapy. OBJECTIVES: The aim of this study was to evaluate the safety and feasibility of transcatheter mitral cerclage ventriculoplasty in patients with MR and either heart failure with reduced ejection fraction or preserved ejection fraction and in subjects with prior edge-to-edge repair but persistent or recurrent symptomatic MR. METHODS: The National Heart, Lung, and Blood Institute Division of Intramural Research Transcatheter Mitral Cerclage Ventriculoplasty Early Feasibility Study (NCT03929913) was an investigator-initiated prospective multicenter study. The primary endpoint was technical success measured at exit from the catheterization laboratory. Follow-up included heart failure quality-of-life assessments and serial imaging with echocardiography and cardiac computed tomography. RESULTS: Nineteen subjects consented and underwent cerclage, 63% with heart failure with reduced ejection fraction and 37% with heart failure with preserved ejection fraction, with ischemic cardiomyopathy in 26% and nonischemic cardiomyopathy in 74%. There were no procedural deaths, strokes, or transient ischemic attacks or other major cardiovascular adverse events. The primary endpoint was met in 17 subjects. Cerclage induced sustained reductions in mitral regurgitant volume (-41%) and effective orifice area (-33%) after a median of 337 days. Cerclage resulted in improvements in 6-minute walking distance (+78 m) and Kansas City Cardiomyopathy Questionnaire Overall Summary Score (+22 points) at 30 days that were maintained after a median of 265 days. New complete heart block developed in 6 of 17 subjects. Three deaths occurred on postprocedural days 79, 159, and 756, unrelated to cerclage. CONCLUSIONS: Transcatheter mitral cerclage ventriculoplasty resulted in significant and sustained improvements in mitral regurgitation and in heart failure quality-of-life assessments.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Disfunción Ventricular Izquierda , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
20.
J Am Coll Cardiol ; 79(8): 772-785, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35210032

RESUMEN

BACKGROUND: The optimal treatment of patients developing infective endocarditis (IE) after transcatheter aortic valve implantation (TAVI) is uncertain. OBJECTIVES: The goal of this study was to investigate the clinical characteristics and outcomes of patients with TAVI-IE treated with cardiac surgery and antibiotics (IE-CS) compared with patients treated with antibiotics alone (IE-AB). METHODS: Crude and inverse probability of treatment weighting analyses were applied for the treatment effect of cardiac surgery vs medical therapy on 1-year all-cause mortality in patients with definite TAVI-IE. The study used data from the Infectious Endocarditis after TAVI International Registry. RESULTS: Among 584 patients, 111 patients (19%) were treated with IE-CS and 473 patients (81%) with IE-AB. Compared with IE-AB, IE-CS was not associated with a lower in-hospital mortality (HRunadj: 0.85; 95% CI: 0.58-1.25) and 1-year all-cause mortality (HRunadj: 0.88; 95% CI: 0.64-1.22) in the crude cohort. After adjusting for selection and immortal time bias, IE-CS compared with IE-AB was also not associated with lower mortality rates for in-hospital mortality (HRadj: 0.92; 95% CI: 0.80-1.05) and 1-year all-cause mortality (HRadj: 0.95; 95% CI: 0.84-1.07). Results remained similar when patients with and without TAVI prosthesis involvement were analyzed separately. Predictors for in-hospital and 1-year all-cause mortality included logistic EuroSCORE I, Staphylococcus aureus, acute renal failure, persistent bacteremia, and septic shock. CONCLUSIONS: In this registry, the majority of patients with TAVI-IE were treated with antibiotics alone. Cardiac surgery was not associated with an improved all-cause in-hospital or 1-year mortality. The high mortality of patients with TAVI-IE was strongly linked to patients' characteristics, pathogen, and IE-related complications.


Asunto(s)
Endocarditis Bacteriana/tratamiento farmacológico , Endocarditis Bacteriana/cirugía , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Infecciones Relacionadas con Prótesis/cirugía , Infecciones Estafilocócicas/tratamiento farmacológico , Infecciones Estafilocócicas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Antibacterianos/uso terapéutico , Procedimientos Quirúrgicos Cardíacos , Terapia Combinada , Endocarditis Bacteriana/etiología , Femenino , Humanos , Masculino , Infecciones Relacionadas con Prótesis/etiología , Infecciones Estafilocócicas/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos