Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Environ Sci Technol ; 57(29): 10754-10762, 2023 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-37428629

RESUMEN

Plastic has been demonstrated to release nanoplastics (NPs) into the atmosphere under sunlight irradiation, posing a continuous health risk to the respiratory system. However, due to lack of reliable quantification methods, the occurrence and distribution of NPs in the atmosphere remain unclear. Polystyrene (PS) micro- and nanoplastics (MNPs) represent a crucial component of atmospheric MNPs. In this study, we proposed a simple and robust method for determining the concentration of atmospheric PS NPs using pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS). Following active sampling, the filter membrane is directly ground and introduced into the Py-GC/MS system to quantify PS NPs. The proposed method demonstrates excellent reproducibility and high sensitivity, with a detection limit as low as down to 15 pg/m3 for PS NPs. By using this method, the occurrence of PS NPs in both indoor and outdoor atmospheres has been confirmed. Furthermore, the results showed that the abundance of outdoor PS NPs was significantly higher than that of indoor samples, and there was no significant difference in NP vertical distribution within a height of 28.6 m. This method can be applied for the routine monitoring of atmospheric PS NPs and for evaluating their risk to human health.


Asunto(s)
Nanopartículas , Contaminantes Químicos del Agua , Humanos , Poliestirenos , Microplásticos , Cromatografía de Gases y Espectrometría de Masas , Pirólisis , Reproducibilidad de los Resultados , Contaminantes Químicos del Agua/análisis , Nanopartículas/química
2.
J Environ Sci (China) ; 128: 45-54, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36801041

RESUMEN

The removal of iodide (I-) from source waters is an effective strategy to minimize the formation of iodinated disinfection by-products (DBPs), which are more toxic than their brominated and chlorinated analogues. In this work, a nanocomposite Ag-D201 was synthesized by multiple in situ reduction of Ag-complex in D201 polymer matrix, to achieve highly efficient removal of iodide from water. Scanning electron microscope /energy dispersive spectrometer characterization showed that uniform cubic silver nanoparticles (AgNPs) evenly dispersed in the D201 pores. The equilibrium isotherms data for iodide adsorption onto Ag-D201 was well fitted with Langmuir isotherm with the adsorption capacity of 533 mg/g at neutral pH. The adsorption capacity of Ag-D201 increased with the decrease of pH in acidic aqueous solution, and reached the maximum value of 802 mg/g at pH 2. This was attributed to the oxidization of I-, by dissolved oxygen under the catalysis of AgNPs, to I2 which was finally adsorbed as AgI3. However, the aqueous solutions at pH 7 - 11 could hardly affect the iodide adsorption. The adsorption of I- was barely affected by real water matrixes such as competitive anions (SO42-, NO3-, HCO3-, Cl-) and natural organic matter, of which interference of NOM was offset by the presence of Ca2+. The proposed synergistic mechanism for the excellent performance of iodide adsorption by the absorbent was ascribed to the Donnan membrane effect caused by the D201 resin, the chemisorption of I- by AgNPs, and the catalytic effect of AgNPs.


Asunto(s)
Nanopartículas del Metal , Contaminantes Químicos del Agua , Agua , Yoduros , Poliestirenos , Plata , Nanopartículas del Metal/química , Contaminantes Químicos del Agua/química , Adsorción
3.
Environ Sci Technol ; 56(7): 4507-4517, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-35192319

RESUMEN

Gaseous arsenic emitted from coal combustion flue gas (CCFG) causes not only severe contamination of the environment but also the failure of selective catalytic reduction (SCR) catalysts in power plants. Development of inexpensive and effective adsorbents or techniques for the removal of arsenic from high-temperature CCFG is crucial. In this study, halloysite nanotubes (HNTs) at low price were modified with CuCl2 (CuCl2-HNTs) through ultrasound assistance and applied for capturing As2O3(g) in simulated flue gas (SFG). Experiments on arsenic adsorption performance, adsorption mechanism, and adsorption energy based on density functional theory were performed. Modification with CuCl2 clearly enhanced the arsenic uptake capacity (approximately 12.3 mg/g) at 600 °C for SFG. The adsorbent exhibited favorable tolerance to high concentrations of NOx and SOx. The As2O3(III) was oxidized and transformed into As2O5(V) on the CuCl2-HNTs. The Al-O bridge had the highest adsorption energy for the O end of the As-O group (-2.986 eV), and the combination formed between arsenic-containing groups and aluminum was stable. In addition, the captured arsenic could be stabilized in the sorbent at high temperature, making it possible to use the sorbent before the SCR system. This demonstrates that CuCl2-HNTs is a promising sorbent for arsenic oxidation and removal from CCFG.


Asunto(s)
Arsénico , Nanotubos , Adsorción , Arcilla , Carbón Mineral , Gases , Temperatura
4.
Anal Chem ; 93(10): 4559-4566, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33646744

RESUMEN

Respective detection of microplastics (MPs) and nanoplastics (NPs) is of great importance for their different environmental behaviors and toxicities. Using spherical polystyrene (PS) and poly(methyl methacrylate) (PMMA) plastics as models, the efficiency for sequential isolation of MPs and NPs by membrane filtration and cloud-point extraction was evaluated. After filtering through a glass membrane (1 µm pore size), over 90.7% of MPs were trapped on the membrane, whereas above 93.0% of NPs remained in the filtrate. The collected MPs together with the glass membrane were frozen in liquid nitrogen, ground, and suspended in water (1 mL) and subjected to pyrolysis-gas chromatography-mass spectrometry (Py-GC/MS) determination. The NPs in the filtrate were concentrated by cloud-point extraction, heated at 190 °C to degrade the extractant, and then determined by Py-GC/MS. For MPs and NPs spiked in pure water, the method detection limits are in the range of 0.05-1.9 µg/L. The proposed method is applied to analyze four real water samples, with the detection of 1.6-7.6 µg/L PS MPs and 0.6 µg/L PMMA MPs in three samples, and spiked recoveries of 75.0-102% for MPs and 67.8-87.2% for NPs. Our method offers a novel sample pretreatment approach for the respective determination of MPs and NPs.


Asunto(s)
Microplásticos , Contaminantes Químicos del Agua , Plásticos , Poliestirenos/análisis , Pirólisis , Contaminantes Químicos del Agua/análisis
5.
J Environ Sci (China) ; 108: 1-7, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34465424

RESUMEN

The distribution and chemical speciation of arsenic (As) in different sized atmospheric particulate matters (PMs), including total suspended particles (TSP), PM10, and PM2.5, collected from Baoding, China were analyzed. The average total mass concentrations of As in TSP, PM10, and PM2.5 were 31.5, 35.3, and 54.1 µg/g, respectively, with an order of PM2.5 >PM 10 > TSP, revealing that As is prone to accumulate on fine particles. Due to the divergent toxicities of different As species, speciation analysis of As in PMs is further conducted. Most of previous studies mainly focused on inorganic arsenite (iAsIII), inorganic arsenate (iAsV), monomethylarsonate (MMA), and dimethylarsinate (DMA) in PMs, while the identification and sensitive quantification of trimethylarsine oxide (TMAO) were rarely reported. In this study, a high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry system was optimized for As speciation including TMAO in PMs. An anion exchange column was used to separate MMA, DMA and iAsV, while a cation exchange column to separate TMAO and iAsIII. Results showed that iAsV was the dominate component in all the samples, corresponding to a portion of 79.2% ± 9.3% of the total extractable species, while iAsIII, TMAO and DMA made up the remaining 21%. Our study demonstrated that iAsIII accounted for about 14.4% ± 11.4% of the total extracted species, with an average concentration of 1.7 ± 1.6 ng/m3. It is worth noting that TMAO was widely present in the samples (84 out of 97 samples), which supported the assumption that TMAO was ubiquitous in atmospheric particles.


Asunto(s)
Arsénico , Arsenicales , Arsénico/análisis , Arsenicales/análisis , Ácido Cacodílico , China , Cromatografía Líquida de Alta Presión , Material Particulado/análisis
6.
Anal Chem ; 91(19): 12525-12530, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31495175

RESUMEN

A new method was developed to determine the nanoparticulate and ionic silver (Ag) species in bacteria (Escherichia coli, E. coli). By removal of the cell wall with lysozyme, the cell surface-adsorbed Ag species were separated from the intracellular Ag species, which were extracted by tetramethylammonium hydroxide and determined by size-exclusion chromatography coupled with inductively coupled plasma mass spectrometry (SEC-ICP-MS). The detection limit is 3 ng/107 CFU/mL (where CFU is colony-forming unit) for both silver nanoparticles (AgNPs) and ionic Ag(I) species. The cell wall-adsorbed Ag was calculated by subtracting the contents of the intra- and extracellular Ag from the total exposure dose of Ag, and therefore the biodistribution of Ag species was profiled. We then applied this strategy to quantitatively analyze extra- and intracellular Ag species in E. coli after respective exposure to Ag+ and 10 and 30 nm AgNPs at different effective concentrations (EC10, EC50, and EC90). Results showed that the intracellular and cell wall-bound Ag account for 5.98-15.21% and 25.13-64.43% of the exposed dose, respectively, and AgNPs could transform into complexed or free Ag+. Our method opens new avenues for the quantitative analysis of the uptake and biodistribution of nanoparticles and their transformation species in bacteria.


Asunto(s)
Escherichia coli/metabolismo , Nanopartículas del Metal , Plata/química , Plata/metabolismo , Transporte Biológico
7.
Anal Chem ; 91(3): 1785-1790, 2019 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-30588801

RESUMEN

The contamination of micro- and nanoplastics in marine systems and freshwater is a global issue. Determination of micro- and nanoplastics in the aqueous environment is of high priority to fully assess the risk that plastic particles will pose. Although microplastics have been detected in a variety of aquatic ecosystems, the analysis of nanoplastics remains an unsolved challenge. Herein, for the first time, a Triton X-45 (TX-45)-based cloud-point extraction (CPE) was proposed to preconcentrate trace nanoplastics in environmental waters. Under the optimum extraction conditions, an enrichment factor of 500 was obtained for two types of nanoplastics with different compositions, polystyrene (PS) and poly(methyl methacrylate) (PMMA), without disturbing their original morphology and sizes. Additionally, following thermal treatment at 190 °C for 3 h, the CPE-obtained extract could be submitted to pyrolysis gas chromatography-mass spectrometry (Py-GC/MS) analysis for mass quantification of nanoplastics. Taking 66.2 nm PS nanoplastics and 86.2 nm PMMA nanoplastics as examples, the proposed method showed excellent reproducibility, and high sensitivity with respective detection limits of 11.5 and 2.5 fM. Feasibility of the proposed approach was verified by application of the optimized procedure to four real water samples. Recoveries of 84.6-96.6% at a spiked level of 88.6 fM for PS nanoplastics and 76.5-96.6% at a spiked level of 50.4 fM for PMMA nanoplastics were obtained. Consequently, this work provides an efficient approach for nanoplastic analysis in environmental waters.


Asunto(s)
Extracción Líquido-Líquido/métodos , Nanopartículas/análisis , Polimetil Metacrilato/análisis , Poliestirenos/análisis , Pirólisis , Disacáridos , Glucuronatos , Límite de Detección , Nanopartículas/química , Octoxinol/química , Polimetil Metacrilato/química , Poliestirenos/química , Reproducibilidad de los Resultados , Ríos/química , Agua de Mar/análisis , Tensoactivos/química , Aguas Residuales/análisis , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química
8.
Environ Sci Technol ; 53(17): 10218-10226, 2019 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-31380632

RESUMEN

To track transformations of silver nanoparticles (AgNPs) in vivo, HepG2 and A549 cells were cocultured with two enriched stable Ag isotopes (107AgNPs and 109AgNO3) at nontoxic doses. After enzymatic digestion, 107AgNPs, ionic 107Ag+ and 109Ag+ in exposed cells could be separated and quantified by liquid chromatography combined with ICP-MS. We found that ratios of 107Ag+ to total 107Ag and proportions of 107Ag+/ 109Ag+ in cells increased gradually after exposure, proving that the Trojan-horse mechanism occurred, i.e., AgNPs released high contents of Ag+ after internalization. While the presence of 109Ag+ (5 and 100 µg/L) has little influence on the uptake of 107AgNPs (0.1 and 2 mg/L), the presence of 107AgNPs at a high dose (2 mg/L) dramatically increases the ingestion of 109Ag+, even though 107AgNPs at a low dose (100 µg/L) showed negligible effects on the internalization of 109Ag+. Cellular homeostasis may be perturbed under sublethal exposure of 107AgNPs, and thus enhanced uptake of 109Ag+. Our findings suggest that the widely adopted control experiments in toxicology studies, culturing organisms with AgNO3 at the same concentration of Ag+ in the AgNP exposure medium, may underestimate uptake of Ag+ and thus cannot exclude suspected toxic effects of Ag+ at high AgNP exposure doses.


Asunto(s)
Nanopartículas del Metal , Plata , Iones , Isótopos , Solubilidad
9.
Environ Sci Technol ; 52(7): 4244-4255, 2018 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-29547286

RESUMEN

AuPd bimetallic nanocatalysts exhibit superior catalytic performance in the cleavage of carbon-halogen bonds (C-X) in the hazardous halogenated pollutants. A better understanding of how Au atoms promote the reactivity of Pd sites rather than vaguely interpreting as bimetallic effect and determining which type of Pd sites are necessary for these reactions are crucial factors for the design of atomically precise nanocatalysts that make full use of both the Pd and Au atoms. Herein, we systematically manipulated the coordination number of Pd-Pd, d-orbital occupation state, and the Au-Pd interface of the Pd reactive centers and studied the structure-activity relationship of Au-Pd in the catalyzed cleavage of C-X bonds. It is revealed that Au enhanced the activity of Pd atoms primarily by increasing the occupation state of Pd d-orbitals. Meanwhile, among the Pd sites formed on the Au surface, five to seven contiguous Pd atoms, three or four adjacent Pd atoms, and isolated Pd atoms were found to be the most active in the cleavage of C-Cl, C-Br, and C-I bonds, respectively. Besides, neighboring Au atoms directly contribute to the weakening of the C-Br/C-I bond. This work provides new insight into the rational design of bimetallic metal catalysts with specific catalytic properties.


Asunto(s)
Carbono , Oro , Catálisis , Halógenos
10.
Environ Sci Technol ; 51(7): 3892-3901, 2017 04 04.
Artículo en Inglés | MEDLINE | ID: mdl-28248108

RESUMEN

Accurate characterization, quantification, and identification of nanoparticles (NPs) are essential to fully understand the environmental processes and effects of NPs. Herein, the elemental mass size distribution (EMSD), which measures particle size, mass, and composition, is proposed for the direct size characterization, mass quantification, and composition identification of trace NPs in complex matrixes. A one-step method for the rapid measurement of EMSDs in 8 min was developed through the online coupling of size-exclusion chromatography (SEC) with inductively coupled plasma mass spectrometry (ICP-MS). The use of a mobile phase with a relatively high ionic strength (a mixture of 2% FL-70 and 2 mM Na2S2O3) ensured the complete elution of different-sized NPs from the column and, therefore, a size-independent response. After application of a correction for instrumental broadening by a method developed in this study, the size distribution of NPs by EMSD determination agreed closely with that obtained from transmission electron microscopy (TEM) analysis. Compared with TEM, EMSD allows a more rapid determination with a higher mass sensitivity (1 pg for gold and silver NPs) and comparable size discrimination (0.27 nm). The proposed EMSD-based method was capable of identifying trace Ag2S NPs and core-shell nanocomposite Au@Ag, as well as quantitatively tracking the dissolution and size transformation of silver nanoparticles in serum and environmental waters.


Asunto(s)
Espectrometría de Masas , Nanopartículas del Metal/química , Oro/química , Tamaño de la Partícula , Plata/química
11.
Environ Sci Technol ; 51(23): 13816-13824, 2017 Dec 05.
Artículo en Inglés | MEDLINE | ID: mdl-29121473

RESUMEN

Efficient separation and preconcentration of trace nanoparticulate silver (NAg) from large-volume environmental waters is a prerequisite for reliable analysis and therefore understanding the environmental processes of silver nanoparticles (AgNPs). Herein, we report the novel use of polyvinylidene fluoride (PVDF) filter membrane for disk-based solid phase extraction (SPE) of NAg in 1 L of water samples with the disk-based SPE system, which consists of a syringe pump and a syringe filter holder to embed the filter membrane. While the PVDF membrane can selectively adsorb NAg in the presence of Ag+, aqueous solution of 2% (m/v) FL-70 is found to efficiently elute NAg. Analysis of NAg is performed following optimization of filter membrane and elution conditions with an enrichment factor of 1000. Additionally, transmission electron microscopy (TEM), UV-vis spectroscopy, and size-exclusion chromatography coupled with ICP-MS (SEC-ICP-MS) analysis showed that the extraction gives rise to no change in NAg size or shape, making this method attractive for practical applications. Furthermore, feasibility of the protocol is verified by applying it to extract NAg in four real waters with recoveries of 62.2-80.2% at 0.056-0.58 µg/L spiked levels. This work will facilitate robust studies of trace NAg transformation and their hazard assessments in the environment.


Asunto(s)
Nanopartículas del Metal , Polivinilos , Contaminantes Químicos del Agua , Plata , Extracción en Fase Sólida
12.
Environ Sci Technol ; 51(21): 12369-12376, 2017 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-29019663

RESUMEN

It is a great challenge to monitor the physical and chemical transformation of nanoparticles at environmentally relevant concentration levels, mainly because the commonly used techniques like dynamic light scattering and transmission electron microscopy are unable to characterize and quantify trace level nanoparticles in complex matrices. Herein, we demonstrate the on-line coupled system of hollow fiber flow field-flow fractionation (HF5), minicolumn concentration, and inductively coupled plasma mass spectrometry (ICPMS) detection as an efficient approach to study the aggregation and chemical transformation of silver nanoparticles (AgNPs) and ionic Ag species in the aqueous environment at ng/mL levels. Taking advantage of the in-line dialysis of HF5, the selective capture of Ag(I) species by the resin in minicolumn, and the high selectivity and sensitivity of ICPMS detection, we recorded the aggregation of 10 ng/mL AgNPs in complex matrices (e.g., NOM, Na+/Ca2+), revealing an interesting tiny AgNPs formation process of photoreduction of trace level Ag(I) that is different from larger AgNPs generated at high concentration of Ag(I) by accurate characterization and respectively identifying and quantifying new thiol-complexed Ag(I) and residual Ag(I) in the intertransformation of Ag(I) and AgNPs in domestic wastewater by simultaneously detecting the S and Ag signals via ICPMS.


Asunto(s)
Nanopartículas del Metal , Plata , Fraccionamiento de Campo-Flujo , Iones
13.
Int J Mol Sci ; 17(3): 409, 2016 Mar 22.
Artículo en Inglés | MEDLINE | ID: mdl-27011169

RESUMEN

The biodegradation of carbon nanotubes (CNTs) may be one of major determinants of the toxic outcomes in exposed individuals. In this study, we employed a macrophage/monocyte model, Raw264.7, to investigate the feasibility of regulating the biodegradation of three types of single-walled carbon nanotubes (SWCNTs) (pristine, ox-, and OH-SWCNTs) by respiratory burst modulation. An artificial fluid mimicking the enzymatic reactions of respiratory burst was constituted to reveal the role of respiratory burst played in SWCNT biodegradation. The biodegradation of SWCNTs were characterized by Raman, ultraviolet-visible-near-infrared spectroscopy, and transmission electron microscopy. Our results showed significantly accelerated biodegradation of ox-SWCNTs and OH-SWCNTs in macrophages activated by phorbol myristate acetate (PMA), which could be prevented by N-acetyl-l-cysteine (NAC), whereas p-SWCNTs were resistant to biodegradation. Similar tendencies were observed by using the in vitro enzymatic system, and the degradation rates of these SWCNTs are in the order of OH-SWCNTs > ox-SWCNTs >> p-SWCNTs, suggesting a pivotal role of respiratory burst in accelerating the biodegradation of SWCNTs and that defect sites on SWCNTs might be a prerequisite for the biodegradation to occur. Our findings might provide invaluable clues on the development of intervention measurements for relieving the side effects of SWCNTs and would help to design safer SWCNT products with higher biodegradability and less toxicity.


Asunto(s)
Macrófagos/metabolismo , Nanotubos de Carbono , Estallido Respiratorio , Animales , Antioxidantes/farmacología , Línea Celular , Macrófagos/efectos de los fármacos , Ratones
14.
Guang Pu Xue Yu Guang Pu Fen Xi ; 36(2): 527-31, 2016 Feb.
Artículo en Zh | MEDLINE | ID: mdl-27209762

RESUMEN

As an important treatment method, sulfur fumigation plays an essential role in the production and preservation of traditional Chinese herbal medicines. Although there is strict regulation on the use of sulfur dioxide, the abuse of sulfur dioxide still occurred from time to time. And the public faces a high risk of exposure. Because of the poor precision and tedious preparation procedures of traditional recommended titration, the accurate and convenient determination of sulfur dioxide in Chinese herbal medicines is still a critical analytical task for medicines safety and the public health. In this study, an accurate, high-throughput, and convenient method for the absolute determination of SO2 in Chinese herbal medicines based on triple quadrupole inductively coupled plasma mass spectrometry (ICP-MS/MS) technique is developed. The study compared the quantitative ability for sulfur when the ICP-MS operated under traditional single quadrupole (QMS) mode and novel triple quadrupole (MS/MS) mode with three Reaction/Collision cell condition (no gas, helium, and oxygen). The result indicated that when the concentration of sulfate ranging from 0.5 to 100 mg · L⁻¹, isotopic ³4S can be selected as quantitative ion either the ICP-MS operated under the QMS mode or MS/MS mode. The use of helium in the Reaction/Collision cell decreased the single intensity of background ions. Better than QMS mode, the MS/MS mode can effectively reduced background interference. But there are no significant differences about the linear range and limit of detection. However, when the ICP-MS operated under MS/MS mode and oxygen was used as reaction gas in the Reaction/Collision cell, the ICP-MS/MS provided an interference-free performance, the linear range and limit of detection improved significantly. Either ³²S or ³4S exhibits an excellent linearity (r > 0.999) over the concentration range of 0.02-100 mg · L⁻¹, with a limit of detection of 5.48 and 9.76 µg · L⁻¹ for ³²S¹6O4²â» and ³4S¹6O4²â», respectively. The Chinese herbal medicines was treated using microwave digestion added 6 mL nitric acid and 2 mL hydrogen peroxide before analysis. The amount of nitric acid and hydrogen peroxide were optimized. The method was validated using Chinese herbal standard reference material GBW10020. The sample was treated and detected in six parallel, and the average concentrations obtained using the developed method (0.42% ± 0.01%) is in excellent agreement with the standard concentration (0.41%± 0.03%). The study demonstrates an accurate and convenient approach for the quantification of SO2 in Chinese herbal medicines.


Asunto(s)
Medicamentos Herbarios Chinos/análisis , Dióxido de Azufre/análisis , Espectrometría de Masas en Tándem , Microondas , Análisis Espectral
15.
Anal Chem ; 87(16): 8441-7, 2015 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-26222150

RESUMEN

The intertransformation of silver nanoparticles (AgNPs) and ionic silver (Ag(I)) in the environment determines their transport, uptake, and toxicity, demanding methods to simultaneously separate and quantify AgNPs and Ag(I). For the first time, hollow fiber flow field-flow fractionation (HF5) and minicolumn concentration were on-line coupled together with multiple detectors (including UV-vis spectrometry, dynamic light scattering, and inductively coupled plasma mass spectrometry) for full spectrum separation, characterization, and quantification of various Ag(I) species (i.e., free Ag(I), weak and strong Ag(I) complexes) and differently sized AgNPs. While HF5 was employed for filtration and fractionation of AgNPs (>2 nm), the minicolumn packed with Amberlite IR120 resin functioned to trap free Ag(I) or weak Ag(I) complexes coming from the radial flow of HF5 together with the strong Ag(I) complexes and tiny AgNPs (<2 nm), which were further discriminated in a second run of focusing by oxidizing >90% of tiny AgNPs to free Ag(I) and trapped in the minicolumn. The excellent performance was verified by the good agreement of the characterization results of AgNPs determined by this method with that by transmission electron microscopy, and the satisfactory recoveries (70.7-108%) for seven Ag species, including Ag(I), the adduct of Ag(I) and cysteine, and five AgNPs with nominal diameters of 1.4 nm, 10 nm, 20 nm, 40 nm, and 60 nm in surface water samples.


Asunto(s)
Fraccionamiento de Campo-Flujo/métodos , Espectrometría de Masas , Nanopartículas del Metal/análisis , Plata/análisis , Cromatografía Líquida de Alta Presión , Fraccionamiento de Campo-Flujo/instrumentación , Iones/química , Luz , Tamaño de la Partícula , Dispersión de Radiación , Plata/aislamiento & purificación , Espectrofotometría Ultravioleta , Agua/química
16.
Environ Sci Technol ; 49(21): 12611-27, 2015 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-26445034

RESUMEN

Ionic liquids (ILs) comprise mostly of organic salts with negligible vapor pressure and low flammability that are proposed as replacements for volatile solvents. ILs have been promoted as "green" solvents and widely investigated for their various applications. Although the utility of these chemicals is unquestionable, their toxic effects have attracted great attention. In order to manage their potential hazards and design environmentally benign ILs, understanding their environmental behavior, fate and effects is important. In this review, environmentally relevant issues of ILs, including their environmental application, environmental behavior and toxicity are addressed. In addition, also presented are the influence of ILs on the environmental fate and toxicity of other coexisting contaminants, important routes for designing nontoxic ILs and the techniques that might be adopted for the removal of ILs.


Asunto(s)
Ambiente , Líquidos Iónicos , Biodegradación Ambiental , Contaminantes Ambientales/análisis , Contaminantes Ambientales/aislamiento & purificación , Contaminantes Ambientales/toxicidad , Líquidos Iónicos/análisis , Líquidos Iónicos/aislamiento & purificación , Líquidos Iónicos/toxicidad , Sales (Química) , Solventes , Presión de Vapor
17.
Environ Sci Technol ; 49(24): 14213-20, 2015 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-26580982

RESUMEN

Hollow fiber supported liquid membrane (HFSLM) extraction was coupled with ICP-MS for speciation analysis of labile Ag(I) and total Ag(I) in dispersions of silver nanoparticles (AgNPs) and environmental waters. Ag(I) in aqueous samples was extracted into the HFSLM of 5%(m/v) tri-n-octylphosphine oxide in n-undecane, and stripped in the acceptor of 10 mM Na2S2O3 and 1 mM Cu(NO3)2 prepared in 5 mM NaH2PO4-Na2HPO4 buffer (pH 7.5). Negligible depletion and exhaustive extraction were conducted under static and 250 rpm shaking to extract the labile Ag(I) and total Ag(I), respectively. The extraction equilibration was reached in 8 h for both extraction modes. The extraction efficiency and detection limit were (2.97 ± 0.25)% and 0.1 µg/L for labile Ag(I), and (82.3 ± 2.0)% and 0.5 µg/L for total Ag(I) detection, respectively. The proposed method was applied to determine labile Ag(I) and total Ag(I) in different sized AgNP dispersions and real environmental waters, with spiked recoveries of total Ag(I) in the range of 74.0-98.1%. With the capability of distinguishing labile and total Ag(I), our method offers a new approach for evaluating the bioavailability and understanding the fate and toxicity of AgNPs in aquatic systems.


Asunto(s)
Extracción Líquido-Líquido/métodos , Nanopartículas del Metal/análisis , Plata/análisis , Contaminantes Químicos del Agua/análisis , China , Límite de Detección , Extracción Líquido-Líquido/instrumentación , Espectrometría de Masas/métodos , Membranas Artificiales , Nanopartículas del Metal/química , Compuestos Organofosforados/química , Tamaño de la Partícula
18.
J AOAC Int ; 98(1): 192-200, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25857897

RESUMEN

A rapid, efficient, and simple one-step ultrasound-assisted extraction (UAE) method was developed for the analysis of seven fungicides (cymoxanil, metalaxyl, mandipropamid, folpet, chlorothalonil, kresoxim-methyl, and famoxadone) in horticultural soils. Analytes in the samples were determined by HPLC with variable wavelength detection. Key parameters that influence the UAE procedure were optimized, such as the nature and volume of extraction solvent, number of sonication steps, and sonication time. The highest extraction efficiencies in the range of 61.1-87.8% were obtained by using only 7.5 mL of ethyl acetate-hexane (1+1, v/v) and sonicating for 10 min. At 0.5 and 2.0 µg/g fortification levels, satisfactory recoveries (>60%) with RSD<13% were obtained for each analyte, except for folpet (>52%). The method was linear over the range of 0.005 to 10 µg/g and the correlation coefficients (r2) obtained ranged from 0.9955 to 0.9992. The LODs (S/N=3) varied from 0.0015 to 0.006 µg/g. The proposed UAE procedure was compared to classical extractions (shake-flask and Soxhlet extraction) and showed satisfactory extraction efficiencies using shorter time and smaller amounts of organic solvents, thereby minimizing the costs of the analysis and the disposal of waste solvent.


Asunto(s)
Fungicidas Industriales/química , Contaminantes del Suelo/química , Ultrasonido , Fraccionamiento Químico/métodos , Estructura Molecular , Reproducibilidad de los Resultados
19.
Anal Chem ; 86(15): 7286-92, 2014 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-24978841

RESUMEN

By coupling surface-enhanced Raman spectroscopy (SERS) with thin layer chromatography (TLC), a facile and powerful method was developed for on-site monitoring the process of chemical reactions. Samples were preseparated on a TLC plate following a common TLC procedure, and then determined by SERS after fabricating a large-area, uniform SERS substrate on the TLC plate by spraying gold nanoparticles (AuNPs). Reproducible and strong SERS signals were obtained with substrates prepared by spraying 42-nm AuNPs at a density of 5.54 × 10(10) N/cm(2) on the TLC plate. The capacity of this TLC-SERS method was evaluated by monitoring a typical Suzuki coupling reaction of phenylboronic acid and 2-bromopyridine as a model. Results showed that this proposed method is able to identify reaction product that is invisible to the naked eye, and distinguish the reactant 2-bromopyridine and product 2-phenylpyridine, which showed almost the same retention factors (R(f)). Under the optimized conditions, the peak area of the characteristic Raman band (755 cm(-1)) of the product 2-phenylpyridine showed a good linear correlation with concentration in the range of 2-200 mg/L (R(2) = 0.9741), the estimated detection limit (1 mg/L 2-phenylpyridine) is much lower than the concentration of the chemicals in the common organic synthesis reaction system, and the product yield determined by the proposed TLC-SERS method agreed very well with that by UPLC-MS/MS. In addition, a new byproduct in the reaction system was found and identified through continuous Raman detection from the point of sample to the solvent front. This facile TLC-SERS method is quick, easy to handle, low-cost, sensitive, and can be exploited in on-site monitoring the processes of chemical reactions, as well as environmental and biological processes.

20.
Environ Sci Technol ; 48(24): 14516-24, 2014 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-25417798

RESUMEN

Sensitive and rapid methods for speciation analysis of nanoparticulate Ag (NAg) and Ag(I) in complex matrices are urgently needed for understanding the environmental effects and biological toxicity of silver nanoparticles (AgNPs). Herein we report the development of a universal liquid chromatography (LC) method for rapid and high resolution separation of dissoluble Ag(I) from nanoparticles covering the entire range of 1-100 nm in 5 min. By using a 500 Å poresize amino column, and an aqueous mobile phase containing 0.1% (v/v) FL-70 (a surfactant) and 2 mM Na2S2O3 at a flow rate of 0.7 mL/min, all the nanoparticles of various species such as Ag and Ag2S were eluted in one fraction, while dissoluble Ag(I) was eluted as a baseline separated peak. The dissoluble Ag(I) was quantified by the online coupled ICP-MS with a detection limit of 0.019 µg/L. The NAg was quantified by subtracting the dissoluble Ag(I) from the total Ag content, which was determined by ICP-MS after digestion of the sample without LC separation. While the addition of FL-70 and Na2S2O3 into the mobile phase is essential to elute NAg and Ag(I) from the column, the use of 500 Å poresize column is the key to baseline separation of Ag(I) from ∼ 1 nm AgNPs. The feasibility of the proposed method was demonstrated in speciation analysis of dissoluble Ag(I) and NAg in antibacterial products and environmental waters, with very good chromatographic repeatability (relative standard deviations) in both peak area (<2%) and retention time (<0.6%), excellent spiked recoveries in the range of 84.7-102.7% for Ag(I) and 81.3-106.3% for NAg. Our work offers a novel approach to rapid and baseline separation of dissoluble metal ions from their nanoparticulate counterparts covering the whole range of 1-100 nm.


Asunto(s)
Antibacterianos/análisis , Cromatografía Liquida/métodos , Nanopartículas del Metal/química , Plata/análisis , Antibacterianos/química , Benzoatos , China , Iones , Lagos/análisis , Límite de Detección , Espectrometría de Masas/métodos , Tamaño de la Partícula , Plata/química , Plata/aislamiento & purificación , Compuestos de Plata/química , Solubilidad , Contaminantes Químicos del Agua/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA