Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 224
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Clin Transplant ; 38(6): e15370, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38922995

RESUMEN

BACKGROUND: Methods for risk stratification of candidates for heart transplantation (HTx) supported by extracorporeal membrane oxygenation (ECMO) are limited. We evaluated the reliability of the APACHE IV score to identify the risk of mortality in this patient subset in a multicenter study. METHODS: Between January 2010 and December 2022, 167 consecutive ECMO patients were bridged to HTx; they were divided into two groups, according to a cutoff value of APACHE IV score, obtained by receiver operating characteristic curve analysis for 90-day mortality. Kaplan-Meier survival curves were plotted, and compared through the log-Rank test. Cox regression model was used to estimate which factors were associated with survival. RESULTS: The 90-day mortality prediction of the APACHE IV score showed an area under the curve of 0.87 (95% CI: 0.80-0.94), with a cutoff value of 49 (specificity 91.7%-sensibility 69.6%). 125 patients (74.8%) showed an APACHE IV score value < 49 (Group A), and 42 (25.2%) ≥ 49 (Group B). 90-day mortality was 11.2% in Group A and 76.2% in Group B (p < 0.01). Survival at 1 and 5 years was 85.5%, 77% versus 23.4%, 23.4% (p < 0.01) in Groups A and B. Mortality correlated at univariable analysis with recipient age, body mass index, mechanical ventilation, APACHE IV score, and platelets number. At multivariable analysis only APACHE IV score (HR: 1.07 [1.05-1.09, 95% CI]) independently affected survival. CONCLUSIONS: The APACHE IV score represents a powerful predictor of survival in patients bridged to HTx on ECMO support, and could guide candidacy of patients on ECMO.


Asunto(s)
APACHE , Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Humanos , Trasplante de Corazón/mortalidad , Femenino , Masculino , Pronóstico , Persona de Mediana Edad , Estudios de Seguimiento , Adulto , Tasa de Supervivencia , Estudios Retrospectivos , Factores de Riesgo , Curva ROC , Medición de Riesgo/métodos
2.
Transpl Int ; 37: 11075, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38525207

RESUMEN

Metabolic Syndrome (MetS), a multifactorial condition that increases the risk of cardio-vascular events, is frequent in Heart-transplant (HTx) candidates and worsens with immunosuppressive therapy. The aim of the study was to analyze the impact of MetS on long-term outcome of HTx patients. Since 2007, 349 HTx patients were enrolled. MetS was diagnosed if patients met revised NCEP-ATP III criteria before HTx, at 1, 5 and 10 years of follow-up. MetS was present in 35% of patients pre-HTx and 47% at 1 year follow-up. Five-year survival in patients with both pre-HTx (65% vs. 78%, p < 0.01) and 1 year follow-up MetS (78% vs 89%, p < 0.01) was worst. At the univariate analysis, risk factors for mortality were pre-HTx MetS (HR 1.86, p < 0.01), hypertension (HR 2.46, p < 0.01), hypertriglyceridemia (HR 1.50, p=0.03), chronic renal failure (HR 2.95, p < 0.01), MetS and diabetes at 1 year follow-up (HR 2.00, p < 0.01; HR 2.02, p < 0.01, respectively). MetS at 1 year follow-up determined a higher risk to develop Coronary allograft vasculopathy at 5 and 10 year follow-up (25% vs 14% and 44% vs 25%, p < 0.01). MetS is an important risk factor for both mortality and morbidity post-HTx, suggesting the need for a strict monitoring of metabolic disorders with a careful nutritional follow-up in HTx patients.


Asunto(s)
Cardiopatías , Trasplante de Corazón , Síndrome Metabólico , Humanos , Síndrome Metabólico/complicaciones , Trasplante de Corazón/efectos adversos , Factores de Riesgo , Morbilidad , Estudios Retrospectivos
3.
BMC Cardiovasc Disord ; 24(1): 258, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762715

RESUMEN

BACKGROUND: Extracorporeal blood purification has been widely used in intensive care medicine, nephrology, toxicology, and other fields. During the last decade, with the emergence of new adsorptive blood purification devices, hemoadsorption has been increasingly applied during CPB in cardiac surgery, for patients at different inflammatory risks, or for postoperative complications. Clinical evidence so far has not provided definite answers concerning this adjunctive treatment. The current systematic review aimed to critically assess the role of perioperative hemoadsorption in cardiac surgery, by summarizing the current knowledge in this clinical setting. METHODS: A literature search of PubMed, Cochrane library, and the database provided by CytoSorbents was conducted on June 1st, 2023. The search terms were chosen by applying neutral search keywords to perform a non-biased systematic search, including language variations of terms "cardiac surgery" and "hemoadsorption". The screening and selection process followed scientific principles (PRISMA statement). Abstracts were considered for inclusion if they were written in English and published within the last ten years. Publications were eligible for assessment if reporting on original data from any type of study (excluding case reports) in which a hemoadsorption device was investigated during or after cardiac surgery. Results were summarized according to sub-fields and presented in a tabular view. RESULTS: The search resulted in 29 publications with a total of 1,057 patients who were treated with hemoadsorption and 988 control patients. Articles were grouped and descriptively analyzed due to the remarkable variability in study designs, however, all reported exclusively on CytoSorb® therapy. A total of 62% (18/29) of the included articles reported on safety and no unanticipated adverse events have been observed. The most frequently reported clinical outcome associated with hemoadsorption was reduced vasopressor demand resulting in better hemodynamic stability. CONCLUSIONS: The role of hemoadsorption in cardiac surgery seems to be justified in selected high-risk cases in infective endocarditis, aortic surgery, heart transplantation, and emergency surgery in patients under antithrombotic therapy, as well as in those who develop a dysregulated inflammatory response, vasoplegia, or septic shock postoperatively. Future large randomized controlled trials are needed to better define proper patient selection, dosing, and timing of the therapy.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Humanos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Factores de Riesgo , Complicaciones Posoperatorias/terapia , Complicaciones Posoperatorias/etiología , Puente Cardiopulmonar/efectos adversos , Masculino , Femenino , Medición de Riesgo , Anciano , Persona de Mediana Edad
4.
Artículo en Inglés | MEDLINE | ID: mdl-38991531

RESUMEN

Expanded polytetrafluoroethylene (ePTFE) neochordae are predominantly used for mitral valve repair (MVr), while the frequency of their employment in tricuspid valve surgery is not well assessed. We have performed a review of the available literature to verify incidence, indications, techniques, and outcomes of the use of artificial neochordae in a variety of tricuspid valve pathologies. We found a total of 57 articles reporting the use of ePTFE sutures in patients in whom tricuspid valve repair (TVr) was performed. From such articles, adequate information on the basic disease, surgical techniques, and outcomes could be obtained in 45 patients in whom the indication to the use of neochordae was posttraumatic tricuspid regurgitation (n = 24), infective endocarditis (n = 8), congenital valvular disease (n = 6), valve injury during cardiac neoplasm excision (n = 3) or following repeated endomyocardial biopsies after heart transplantation (n = 3), and tricuspid valve prolapse (n = 1). Implant techniques generally replicated those currently employed for MVr using artificial neochordae. There were no reported hospital deaths with stability of repair in most cases at follow-up controls. TVr using ePTFE neochordae has been reported so far in a limited number of patients. Nevertheless, it appears a feasible and reproducible technique to be added routinely to the surgical armamentarium during TVr.

5.
Clin Transplant ; 37(5): e14950, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36823475

RESUMEN

INTRODUCTION: Heart transplant (HTx) recipients require continuous monitoring and care in order to prevent and treat possible complications related to the graft function or to the immunosuppressive treatment promptly. Since heart transplantation centers (HTC) are more experienced in managing HTx recipients than other healthcare facilities, the distance between patient residency and HTC could negatively affect the outcomes. METHODS: Data of patients discharged after receiving HTx between 2000 and 2021, collected into our institutional database, were retrospectively analyzed. The population was divided into three groups: A (n = 180), B (n = 157), and C (n = 134), according to the distance tertiles between patient residency and HTC. The primary end-point was survival, secondary end-points were incidences of complications. RESULTS: Recipient and donor characteristics did not differ between the three groups. Survival at 10 years was 66 ± 4%, 66 ± 4%, and 65 ± 5%, respectively, for groups A, B, and C (p = .34). Immunosuppressive regimen and rate of complications did not differ between groups. However, the rates of outpatient visits and of hospitalization performed at HTC were higher in group A than others. CONCLUSION: Distance from the HTC does not represent a barrier to a successful outcome for HTx recipients, as long as regular and continuous follow-up is provided.


Asunto(s)
Trasplante de Corazón , Internado y Residencia , Humanos , Estudios Retrospectivos , Bases de Datos Factuales , Trasplante de Corazón/efectos adversos , Hospitalización , Inmunosupresores
6.
Transpl Int ; 36: 11089, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37547752

RESUMEN

Extending selection criteria to face donor organ shortage in heart transplantation (HTx) may increase the risk of mortality. Ex-vivo normothermic perfusion (EVP) limits ischemic time allowing assessment of graft function. We investigated the outcome of HTx in 80 high-risk recipients transplanted with marginal donor and EVP-preserved grafts, from 2016 to 2021. The recipients median age was 57 years (range, 13-75), with chronic renal failure in 61%, impaired liver function in 11% and previous cardiac surgery in 90%; 80% were mechanically supported. Median RADIAL score was 3. Mean graft ischemic time was 118 ± 25 min, "out-of-body" time 420 ± 66 min and median cardiopulmonary bypass (CPB) time 228 min (126-416). In-hospital mortality was 11% and ≥moderate primary graft dysfunction 16%. At univariable analysis, CPB time and high central venous pressure were risk factors for mortality. Actuarial survival at 1 and 3 years was 83% ± 4%, and 72% ± 7%, with a median follow-up of 16 months (range 2-43). Recipient and donor ages, pre-HTx extracorporeal life support and intra-aortic balloon pump were risk factors for late mortality. In conclusion, the use of EVP allows extension of the graft pool by recruitment of marginal donors to successfully perform HTx even in high-risk recipients.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Trasplante de Corazón , Obtención de Tejidos y Órganos , Humanos , Persona de Mediana Edad , Donantes de Tejidos , Perfusión , Preservación de Órganos , Supervivencia de Injerto
7.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34894124

RESUMEN

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Asunto(s)
Aneurisma Falso , Endocarditis Bacteriana , Endocarditis , Insuficiencia Renal Crónica , Reemplazo de la Válvula Aórtica Transcatéter , Absceso , Aneurisma Falso/complicaciones , Aneurisma Falso/cirugía , Coagulasa , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Insuficiencia Renal Crónica/complicaciones , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
8.
Rev Cardiovasc Med ; 23(7): 228, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39076901

RESUMEN

Background and Aim of the Study: In patients with acute type A aortic dissection (A-AAD) whether initial repair should include also aortic arch replacement is still debated. We aimed to assess if extensive aortic repair prevents from reoperations patients with A-AAD. Methods: Outcomes after distal reoperation following repair of A-AAD (n = 285; 1977 to 2018) were analysed in 22 of 226 who underwent ascending aorta/hemiarch replacement (Group 1 R ) and 7 of 59 who had ascending aorta/arch replacement (Group 2 R ). Results: Distal reoperation was more common in Group 1 R (n = 22) than in Group 2 R (n = 0) (p < 0.001) while thoracic endovascular stenting was more frequent in Group 2 R (7 vs 3, p < 0.001). Indications for reoperation were pseudoaneurysm at distal anastomosis (n = 4, 18%) and progression of aortic dissection (n = 18, 82%) in Group 1 R . Indication for thoracic endovascular stenting was progressive aortic dissection in 3 patients of Group 1 R and in 6 of Group 2 R . Second reoperation was required in 2 patients from Group 1 R (2%) during a mean follow-up of 5 years. Median follow-up was 4 years in Group 1 R and 7 years in Group 2 R (p = 0.36). Hospital mortality was 14% in Group 1 R and 0% in Group 2 R (p = 0.3). Actuarial survival is 68 ± 10%, and 62 ± 11% for Group 1 R and 100% for Group 2 R at 5 and 10 years (p = 0.076). Conclusions: Distal reoperations after A-AAD repair have an acceptable mortality. An extensive initial repair has lower rate of reoperation and better mid-term survival and should be indicated especially for young patients in experienced centers.

9.
Artif Organs ; 46(11): 2319-2324, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35802767

RESUMEN

Left ventricular assist device (LVAD) has emerged as an effective surgical therapy for end-stage heart failure. In an attempt to reduce invasiveness and avoid difficult sternal re-entries, alternative surgical approaches have been adopted. In particular, when the thoracic aorta is severely diseased or difficult to expose, subclavian arteries could serve as site for outflow graft anastomosis. However, major concerns regarding the utilization of subclavian arteries are the small caliber of these vessels that could lead to inadequate LVAD flow, arm complications related to excessive blood flow, and possible outflow graft compression. In the present case series, we describe an innovative technique for LVAD implantation, in which the left subclavian artery was employed as an outflow graft anastomosis site, and the left ventricular apex was approached through a mini-thoracotomy. Technical issues were considered to prevent possible complications: the adequacy of left subclavian artery diameter, the banding of the artery distal to the anastomosis site to limit left arm overflow, and the outflow graft covering with a reinforced vascular graft to avoid any external compression. During follow-up, the technique reported was found to be effective in ensuring good LVAD function and flow, and no complications related to the procedure were reported.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Corazón Auxiliar/efectos adversos , Arteria Subclavia/cirugía , Aorta Torácica/cirugía , Ventrículos Cardíacos/cirugía , Hemodinámica , Insuficiencia Cardíaca/cirugía
10.
Artif Organs ; 46(9): 1932-1936, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35718933

RESUMEN

BACKGROUND: Patients with LVAD require continuous monitoring and care, and since Implanting Centers (ICs) are more experienced in managing LVAD patients than other healthcare facilities, the distance between patient residency and IC could negatively affect the outcomes. METHODS: Data of patients discharged after receiving an LVAD implantation between 2010 and 2021 collected from the MIRAMACS database were retrospectively analyzed. The population was divided into two groups: A (n = 175) and B (n = 141), according to the distance between patient residency and IC ≤ or >90 miles. The primary endpoint was freedom from Adverse Events (AEs), a composite outcome composed of death, cerebrovascular accident, hospital admission because of GI bleeding, infection, pump thrombosis, and right ventricular failure. Secondary endpoints were incidences of mortality and complications. All patients were followed-up regularly, according to participating center protocols. RESULTS: Baseline clinical characteristics and indications for LVAD did not differ between the two groups. The mean duration of support was 25.5 ± 21 months for Group A and 25.7 ± 20 months for Group B (p = 0.79). At 3 years, freedom from AEs was similar between Group A and Group B (p = 0.36), and there were no differences in rates of mortality and LVAD-related complications. CONCLUSIONS: Distance from the IC does not represent a barrier to successful outcomes as long as regular and continuous follow-up is provided.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Internado y Residencia , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
11.
Artif Organs ; 46(12): 2486-2492, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35866429

RESUMEN

BACKGROUND: We investigated the synergistic effect of the new cone-bearing design of Jarvik 2000 (Jarvik Heart Inc., NY) together with a minimally-invasive approach to outcomes of LVAD patients. METHODS: We retrospectively reviewed all patients from 5 institutions involved in the Jarvik 2000 Italian Registry, from October 2008 to October 2016. Patients were divided into three groups according to pump design and implantation technique: pin-bearing design and conventional approach (Group 1); cone-bearing and conventional approach (Group 2); cone-bearing and minimally-invasive implantation (Group 3). RESULTS: A total of 150 adult patients with end-stage heart failure were enrolled: 26 subjects in Group 1, 74 in Group 2, and 50 in Group 3. Nineteen patients (73%) in Group 1, 51 (69%) in Group 2, and 36 (72%) in Group 3 were discharged. During follow-up, 22 patients underwent transplantation, while in 3 patients the LVAD was explanted. The overall 1-year survival was 58 ± 10%, 64 ± 6%, and 74% ± 7% in Groups 1, 2, and 3, respectively (p = 0.034). The competing-risks-adjusted cumulative incidence rate for adverse events was 42.1 [27-62.7] per 100 patient-years in Group 1, 35.4 [25.3-48.2] in Group 2, and 22.1 [12.4-36.4] in Group 3 (p = 0.046 for Group 1 vs. 3). CONCLUSIONS: The association of the modern cone-bearing configuration of Jarvik 2000 and minimally invasive surgery improved survival and minimized the risk for cardiovascular events, as a result of combining technology and technique.


Asunto(s)
Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Adulto , Corazón Auxiliar/efectos adversos , Estudios Retrospectivos , Insuficiencia Cardíaca/cirugía , Sistema de Registros , Tecnología , Resultado del Tratamiento
12.
J Card Surg ; 37(11): 3722-3728, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36116053

RESUMEN

BACKGROUND: Mitral valve repair using expanded polytetrafluoroethylene sutures to replace mitral chordae tendineae is a well-established procedure. However, the incidence of neo-chordae failure causing recurrent mitral regurgitation is not well defined. METHODS: We have reviewed the reported cases of complications after mitral valve repair related to the use of neo-chordae. This study was mainly carried out through PubMed, Medline, and Google Chrome websites. RESULTS: We have identified a total of 26 patients presenting with rupture of polytetrafluoroethylene neo-chordae, mostly being described as isolated cases. Few other cases of recurrent mitral regurgitation with hemolysis were found, where reoperation was not caused by neo-chordal failure but most likely by technical errors. At pathological investigation the findings were substantially similar in all reported cases. The neo-chordae retained their length and pliability, became covered with host tissue and rupture was mainly related to suture size. Mild calcification was observed not interfering with chordal function; chordal infection did never occur. CONCLUSIONS: The use of artificial neo-chordae provides excellent late results with durable mitral valve repair stability. Chordal rupture may occur late postoperatively leading to reoperation because of recurrent mitral regurgitation. Despite its rarity, this potential complication should not be overlooked during follow-up of patients after mitral valve repair using artificial neo-chordae.


Asunto(s)
Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Cuerdas Tendinosas/patología , Cuerdas Tendinosas/cirugía , Humanos , Válvula Mitral/patología , Válvula Mitral/cirugía , Prolapso de la Válvula Mitral/cirugía , Politetrafluoroetileno , Suturas
13.
J Card Surg ; 37(7): 1959-1966, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35385588

RESUMEN

BACKGROUND: Aim of this study is to analyse the performances of Clinical Risk Score (CRS) and European System for Cardiac Operative Risk Evaluation (EuroSCORE)-II in isolated tricuspid surgery. METHODS: Three hundred and eighty-three patients (54 ± 16 year; 54% female) were enrolled. Receiver operating characteristic analysis was performed to evaluate the relationship between the true positive fraction of test results and the false-positive fraction for a procedure. RESULTS: Considering the 30-day mortality the area under the curve was 0.6 (95% confidence interval [CI] 0.50-0.72) for EuroSCORE II and 0.7 (95% CI 0.56-0.84) for CRS-score. The ratio of expected/observed mortality showed underestimation when considering EuroSCORE-II (min. 0.46-max. 0.6). At multivariate analysis, the CRS score (p = .005) was predictor of late cardiac death. CONCLUSION: We suggest using both scores to obtain a range of expected mortality. CRS to speculate on late survival.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Válvula Tricúspide , Femenino , Mortalidad Hospitalaria , Humanos , Masculino , Curva ROC , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Válvula Tricúspide/cirugía
14.
J Card Surg ; 37(1): 165-173, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34717007

RESUMEN

OBJECTIVE: To analyze Italian Cardiac Surgery experience during the pandemic of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) identifying risk factors for overall mortality according to coronavirus disease 2019 (COVID-19) status. METHODS: From February 20 to May 31, 2020, 1354 consecutive adult patients underwent cardiac surgery at 22 Italian Centers; 589 (43.5%), patients came from the red zone. Based on COVID-19 status, 1306 (96.5%) were negative to SARS-CoV-2 (COVID-N), and 48 (3.5%) were positive to SARS-CoV-2 (COVID-P); among the COVID-P 11 (22.9%) and 37 (77.1%) become positive, before and after surgery, respectively. Surgical procedures were as follows: 396 (29.2%) isolated coronary artery bypass grafting (CABG), 714 (52.7%) isolated non-CABG procedures, 207 (15.3%) two associate procedures, and three or more procedures in 37 (2.7%). Heart failure was significantly predominant in group COVID-N (10.4% vs. 2.5%, p = .01). RESULTS: Overall in-hospital mortality was 1.6% (22 cases), being significantly higher in COVID-P group (10 cases, 20.8% vs. 12, 0.9%, p < .001). Multivariable analysis identified COVID-P condition as a predictor of in-hospital mortality together with emergency status. In the COVID-P subgroup, the multivariable analysis identified increasing age and low oxygen saturation at admission as risk factors for in-hospital mortality. CONCLUSION: As expected, SARS-CoV-2 infection, either before or soon after cardiac surgery significantly increases in-hospital mortality. Moreover, among COVID-19-positive patients, older age and poor oxygenation upon admission seem to be associated with worse outcomes.


Asunto(s)
COVID-19 , SARS-CoV-2 , Adulto , Anciano , Puente de Arteria Coronaria , Humanos , Pronóstico
15.
J Mol Cell Cardiol ; 151: 15-30, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33159916

RESUMEN

The prominent impact that coronary microcirculation disease (CMD) exerts on heart failure symptoms and prognosis, even in the presence of macrovascular atherosclerosis, has been recently acknowledged. Experimental delivery of pericytes in non-revascularized myocardial infarction improves cardiac function by stimulating angiogenesis and myocardial perfusion. Aim of this work is to verify if pericytes (Pc) residing in ischemic failing human hearts display altered mechano-transduction properties and to assess which alterations of the mechano-sensing machinery are associated with the observed impaired response to mechanical cues. RESULTS: Microvascular rarefaction and defects of YAP/TAZ activation characterize failing human hearts. Although both donor (D-) and explanted (E-) heart derived cardiac Pc support angiogenesis, D-Pc exert this effect significantly better than E-Pc. The latter are characterized by reduced focal adhesion density, decreased activation of the focal adhesion kinase (FAK)/ Crk-associated substrate (CAS) pathway, low expression of caveolin-1, and defective transduction of extracellular stiffness into cytoskeletal stiffening, together with an impaired response to both fibronectin and lysophosphatidic acid. Importantly, Mitogen-activated protein kinase kinase inhibition restores YAP/TAZ nuclear translocation. CONCLUSION: Heart failure impairs Pc mechano-transduction properties, but this defect could be reversed pharmacologically.


Asunto(s)
Insuficiencia Cardíaca/patología , Mecanotransducción Celular , Miocardio/patología , Pericitos/metabolismo , Pericitos/patología , Actomiosina/metabolismo , Proteínas Adaptadoras Transductoras de Señales/metabolismo , Fenómenos Biomecánicos , Caveolina 1/metabolismo , Núcleo Celular/metabolismo , Células Cultivadas , Vasos Coronarios/patología , Vasos Coronarios/fisiopatología , Citoesqueleto/metabolismo , Adhesiones Focales , Humanos , Microvasos/patología , Microvasos/fisiopatología , Quinasas de Proteína Quinasa Activadas por Mitógenos/metabolismo , Isquemia Miocárdica/metabolismo , Isquemia Miocárdica/patología , Transporte de Proteínas , Transactivadores/metabolismo , Factores de Transcripción/metabolismo , Transcripción Genética , Proteínas Señalizadoras YAP
16.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-33733675

RESUMEN

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Asunto(s)
Endocarditis Bacteriana , Endocarditis , Reemplazo de la Válvula Aórtica Transcatéter , Endocarditis/epidemiología , Endocarditis/etiología , Endocarditis/cirugía , Endocarditis Bacteriana/epidemiología , Endocarditis Bacteriana/etiología , Endocarditis Bacteriana/cirugía , Humanos , Incidencia , Complicaciones Posoperatorias/epidemiología , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Transpl Int ; 34(2): 281-289, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33258174

RESUMEN

BACKGROUND: Cardiac allograft vasculopathy (CAV) is an important cause of late mortality after heart transplantation, which may be influenced by preexisting coronary disease (CAD) in the donor heart. METHODS: The aim of this study was to verify whether CAD in the donor heart had any influence on survival, cardiac-related adverse events (CRAEs), and coronary disease progression after transplantation. Donor coronary angiography performed in 289 hearts showed absence of CAD in 232 (no-CAD group) and moderate (≤50%) stenoses (CAD group) in 57. The 2 groups were compared for survival, freedom from CRAEs, and development of grade ≥ 2 CAV after transplantation. RESULTS: Of 30-day mortality and postoperative complication rate was similar as mean follow-up (76 ± 56 and 75 ± 55 months) for no-CAD and CAD (P = 0.8). Ten-year actuarial survival was 58 ± 4% and 62 ± 7% for no-CAD and CAD (P = 0.4). Ten-year freedom from grade ≥ 2 CAV and from CRAEs was 81 ± 4% and 66 ± 5% vs 75 ± 8% and 67 ± 9% in no-CAD and CAD (P = 0.9 and 0.9, respectively). CONCLUSIONS: Donor hearts with moderate CAD did not affect survival, freedom from CRAEs and did not accelerate development of high-grade CAV after transplantation supporting the use of such grafts to expand the donor pool. Routine use of coronary angiography in donor selection appears justified.


Asunto(s)
Enfermedad de la Arteria Coronaria , Trasplante de Corazón , Angiografía Coronaria , Trasplante de Corazón/efectos adversos , Humanos , Complicaciones Posoperatorias , Estudios Retrospectivos , Factores de Tiempo , Donantes de Tejidos
18.
Artif Organs ; 45(3): 236-243, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32860268

RESUMEN

Continuous flow left ventricular assist devices (LVADs) have become a valuable therapy for end-stage heart failure. In vitro research highlighted a role of outflow cannula position on the pattern of blood flow in the aorta. However, the clinical effects of the alterations of flow remain unclear. We investigate short- and long-term outcomes of patients implanted with Jarvik 2000 LVAD, according to the ascending (Group 1) versus descending (Group 2) outflow graft connection to the aorta in a multicenter study. From May 2008 to October 2014, 140 consecutive end-stage heart failure patients underwent Jarvik 2000 LVAD implantation in 17 Italian centers. According with a preliminary multivariate analysis, we selected the 90 patients implanted in the four high-volume centers to avoid bias (Group 1 n = 39, Group 2 n = 51). Among the groups, no differences were recorded in the hospital mortality and the main complications occurring after LVAD implantation were similar. In multivariable analysis, the ascending aorta outflow cannula position and higher creatinine at discharge were significant predictors for long-term survival. Postimplant hemolysis was more pronounced in descending aorta outflow graft anastomosis. Outflow graft anastomosis to the ascending aorta is associated with better long-term survival, independent of age and perfusion techniques, reflecting the previous in vitro results.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Anciano , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Aorta/fisiopatología , Aorta/cirugía , Creatinina/sangre , Femenino , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Hemodinámica/fisiología , Hemólisis/fisiología , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Resultado del Tratamiento
19.
J Card Surg ; 36(12): 4690-4698, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34519088

RESUMEN

BACKGROUND AND AIM: Blood cysts of cardiac valves are generally seen in newborns and infants and very rarely in adults. Although in most cases they are incidental findings they may be associated to severe cardiac or systemic complications. This study analyzes incidence, presentation, and treatment of valvular blood cysts in adults. METHODS: A review of the pertinent literature through a search mainly on PubMed and Medline was performed. RESULTS: In patients ≥18 years of age, our search disclosed 54 patients with mitral blood cysts (mean age, 48 ± 18 years), 9 with a tricuspid valve cyst (mean age, 67 ± 15 years), 3 with a blood cyst on the pulmonary valve (age 31, 43, and 44 years), and 1 aortic valve cyst in a 22-year-old man. Most patients were asymptomatic while stroke, syncope, or myocardial infarction occurred in six patients with a mitral valve cyst. Blood cysts were removed surgically in 70% of patients with a mitral cyst, in 55% with a tricuspid cyst, and in all those with a pulmonary or aortic cyst. At histology, the cyst wall was composed mainly by fibrous tissue and with the inner surface lined with typical endothelium. CONCLUSIONS: Blood cysts of cardiac valves are rare in adults but may cause life-threatening complications, particularly when located on the mitral valve. For such reason, surgical removal appears advisable, with low-risk procedures. Widespread use of multimodality imaging techniques will most likely increase the number of valvular blood cysts diagnosed also in adults.


Asunto(s)
Quistes , Válvula Pulmonar , Adulto , Anciano , Anciano de 80 o más Años , Válvula Aórtica , Quistes/diagnóstico por imagen , Quistes/epidemiología , Quistes/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Válvula Tricúspide , Adulto Joven
20.
Heart Fail Clin ; 17(2): 273-278, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-33673951

RESUMEN

Patients with heart failure suffered by a complex syndrome, where the filling of the ventricle or ejection of the blood is impaired. In this setting, the exercise capacity decreases for many reasons, one of them being the insufficient oxygen transfer due to reduced cardiac output and anemia. Ventricular assist device has emerged as a durable and safe therapy for patients with end-stage heart failure. The benefits of cardiac rehabilitation in ventricular assist device patients are enormous: the first aim is to progressively reduce the physical and functional impairments of these patients, so that they will be able to resume meaningful daily activities.


Asunto(s)
Rehabilitación Cardiaca/métodos , Insuficiencia Cardíaca/rehabilitación , Ventrículos Cardíacos/fisiopatología , Corazón Auxiliar , Prueba de Esfuerzo , Tolerancia al Ejercicio , Insuficiencia Cardíaca/fisiopatología , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA