Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Langmuir ; 31(45): 12447-54, 2015 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-26509712

RESUMEN

The use of immobilized enzymes is mandatory for the easy separation of the enzyme, the unreacted substrates, and the obtained products to allow repeated enzymatic assays without cumbersome purification steps. The immobilization procedure is however critical to obtain a high fraction of active enzyme. In this article, we present an enzyme immobilization strategy based on a catechol functionalized alginate. We demonstrate that alkaline phosphatase (ALP) remains active in multilayered films made with alginate modified with catechol moieties (AlgCat) for long duration, that is, up to 7 weeks, provided the multilayered architecture is cross-linked with sodium periodate. This cross-linking reaction allows to create covalent bonds between the amino groups of ALP and the quinone group carried by the modified alginate. In the absence of cross-linking, the enzymatic activity is rapidly lost and this reduction is mainly due to enzyme desorption. We also show that NaIO4 cross-linked (AlgCat-Alp)n films can be freeze-dried and reused at least 3 weeks later without lost in enzymatic activity.


Asunto(s)
Adhesivos/química , Alginatos/química , Fosfatasa Alcalina/química , Materiales Biomiméticos/química , Catecoles/química , Enzimas Inmovilizadas/química , Animales , Bivalvos/química , Bivalvos/fisiología , Reactivos de Enlaces Cruzados/química , Pruebas de Enzimas , Equipo Reutilizado , Liofilización , Ácido Glucurónico/química , Ácidos Hexurónicos/química , Cinética , Ácido Peryódico/química
2.
J Am Chem Soc ; 134(1): 83-6, 2012 Jan 11.
Artículo en Inglés | MEDLINE | ID: mdl-22188330

RESUMEN

Cell adhesion processes take place through mechanotransduction mechanisms where stretching of proteins results in biological responses. In this work, we present the first cyto-mechanoresponsive surface that mimics such behavior by becoming cell-adhesive through exhibition of arginine-glycine-aspartic acid (RGD) adhesion peptides under stretching. This mechanoresponsive surface is based on polyelectrolyte multilayer films built on a silicone sheet and where RGD-grafted polyelectrolytes are embedded under antifouling phosphorylcholine-grafted polyelectrolytes. The stretching of this film induces an increase in fibroblast cell viability and adhesion.


Asunto(s)
Mecanotransducción Celular , Polímeros/química , Biomimética , Adhesión Celular , Electrólitos/química , Fibroblastos/citología , Oligopéptidos/química , Propiedades de Superficie
3.
ACS Sens ; 4(8): 2039-2047, 2019 08 23.
Artículo en Inglés | MEDLINE | ID: mdl-31282146

RESUMEN

Ion sensitive field effect transistors (ISFETs) form a very attractive solution for wearable sensors due to their capacity for ultra-miniaturization, low power operation, and very high sensitivity, supported by complementary metal oxide semiconductor (CMOS) integration. This paper reports for the first time, a multianalyte sensing platform that incorporates high performance, high yield, high robustness, three-dimensional-extended-metal-gate ISFETs (3D-EMG-ISFETs) realized by the postprocessing of a conventional 0.18 µm CMOS technology node. The detection of four analytes (pH, Na+, K+, and Ca2+) is reported with excellent sensitivities (58 mV/pH, -57 mV/dec(Na+), -48 mV/dec(K+), and -26 mV/dec(Ca2+)) close to the Nernstian limit, and high selectivity, achieved by the use of highly selective ion selective membranes based on postprocessing integration steps aimed at eliminating any significant sensor hysteresis and parasitics. We are reporting simultaneous time-dependent recording of multiple analytes, with high selectivities. In vitro real sweat tests are carried out to prove the validity of our sensors. The reported sensors have the lowest reported power consumption, being capable of operation down to 2 pW/sensor. Due to the ultralow power consumption of our ISFETs, we achieve and report a final four-analyte passive system demonstrator including the readout interface and the remote powering of the ISFET sensors, all powered by an radio frequency (RF) signal.


Asunto(s)
Técnicas Biosensibles , Calcio/análisis , Técnicas Electroquímicas , Potasio/análisis , Sodio/análisis , Transistores Electrónicos , Biomarcadores/análisis , Técnicas Biosensibles/instrumentación , Técnicas Electroquímicas/instrumentación , Electrodos , Diseño de Equipo , Concentración de Iones de Hidrógeno , Semiconductores , Plata/química , Compuestos de Plata/química
4.
ACS Nano ; 12(12): 12646-12656, 2018 12 26.
Artículo en Inglés | MEDLINE | ID: mdl-30543395

RESUMEN

Wearable systems could offer noninvasive and real-time solutions for monitoring of biomarkers in human sweat as an alternative to blood testing. Recent studies have demonstrated that the concentration of certain biomarkers in sweat can be directly correlated to their concentrations in blood, making sweat a trusted biofluid candidate for noninvasive diagnostics. We introduce a fully on-chip integrated wearable sweat sensing system to track biochemical information at the surface of the skin in real time. This system heterogeneously integrates, on a single silicon chip, state-of-the-art ultrathin body (UTB) fully depleted silicon-on-insulator (FD-SOI) ISFET sensors with a biocompatible microfluidic interface, to deliver a "lab-on-skin" sensing platform. A full process for the fabrication of this system is proposed in this work and is demonstrated by standard semiconductor fabrication procedures. The system is capable of collecting small volumes of sweat from the skin of a human and posteriorly passively driving the biofluid, by capillary action, to a set of functionalized ISFETs for analysis of pH level and Na+ and K+ concentrations. Drop-casted ion-sensing membranes on different sets of sensors on the same substrate enable multiparameter analysis on the same chip, with small and controlled cross-sensitivities, whereas a miniaturized quasireference electrodes set a stable analyte potential, avoiding the use of a cumbersome external reference electrode. The progress of lab-on-skin technology reported here can lead to autonomous wearable systems enabling real-time continuous monitoring of sweat composition, with applications ranging from medicine to lifestyle behavioral engineering and sports.


Asunto(s)
Técnicas Biosensibles , Técnicas Analíticas Microfluídicas , Piel/química , Sudor/química , Transistores Electrónicos , Dispositivos Electrónicos Vestibles , Técnicas Biosensibles/instrumentación , Humanos , Iones/química , Técnicas Analíticas Microfluídicas/instrumentación , Tamaño de la Partícula , Potasio/química , Silicio/química , Sodio/química , Propiedades de Superficie
5.
Chem Commun (Camb) ; 51(1): 232-5, 2015 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-25407087

RESUMEN

GFP has been genetically modified at two specific positions of its molecular architecture. These modifications allow its covalent attachment onto PEG brushes grafted on functionalized silicone surfaces. The stretching of this material leads to a reversible decrease of the fluorescence intensity due to stretch-induced forces applying on GFP molecules.


Asunto(s)
Aminoácidos/metabolismo , Proteínas Fluorescentes Verdes/química , Aminoácidos/química , Compuestos de Bencilo/química , Química Clic , Dimetilpolisiloxanos/química , Proteínas Fluorescentes Verdes/genética , Proteínas Fluorescentes Verdes/metabolismo , Imidazolinas/química , Microscopía Fluorescente , Proteínas Recombinantes/biosíntesis , Proteínas Recombinantes/química , Proteínas Recombinantes/genética , Silicio/química
6.
Chem Commun (Camb) ; 51(26): 5622-5, 2015 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-25719225

RESUMEN

Using modified ß-galactosidase covalently linked to cross-linked polyelectrolyte multilayers (PEM), catalytically active materials have been designed. Their enzymatic activity can be modulated, partially in a reversible way, simply by stretching. This strategy, based on enzyme conformational changes, constitutes a new tool for the development of biocatalytic mechano-responsive materials.


Asunto(s)
Materiales Biomiméticos/química , Biotecnología/métodos , beta-Galactosidasa/metabolismo , Biocatálisis , Materiales Biomiméticos/metabolismo , Biomimética , Electrólitos/química , Electrólitos/metabolismo , Activación Enzimática , Modelos Moleculares , Conformación Molecular , Polímeros/química , Polímeros/metabolismo , beta-Galactosidasa/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA