Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Catheter Cardiovasc Interv ; 104(1): 134-144, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38736247

RESUMEN

BACKGROUND: In transcatheter aortic valve replacement (TAVR), transfemoral (TF) access offers several advantages over alternative access routes. Advances in sheaths and valve delivery technology have catalyzed the feasibility of TF-TAVR, even in challenging anatomies. AIMS: Report procedural characteristics and outcomes of a TAVR program aiming for a 100% TF access rate. METHODS: Consecutive patients undergoing TAVR were enrolled in a prospective registry. Equipment used to facilitate TF-access in challenging anatomies included low-profile sheaths, dilatators, peripheral balloons, covered and uncovered self-expanding and balloon-expandable stents, and intravascular lithotripsy (IVL). RESULTS: A total of 400 patients with a mean age of 81 ± 6 years (42% female) were analyzed. Minimal iliofemoral artery diameter (MLD) of the main access side was <5 mm in 42 (10.5%), extreme tortuosity was present in 65 (16.3%), and severe calcification in 59 (14.8%). TF-access was successful in 399 (99.8%) patients. A transaxillary access was used in one patient. In multivariable analysis, an MLD < 5 mm was the strongest predictor for vascular complications (11.9% vs. 3.9%, OR: 3.86, 95% CI: 1.38-10.8, p = 0.01). Such patients also had more major/life-threatening bleeding (14.2% vs. 3.1%, p < 0.001) and required more planned and unplanned peripheral interventions to enable TF access (35.8% vs. 3.4%, p < 0.001). CONCLUSION: Our study shows that utilization of dedicated sheaths, peripheral balloons, stents, and IVL enables TAVR via TF access in >99% of patients. However, rates of vascular and bleeding complications in patients with narrow iliofemoral arteries (MLD < 5 mm) were high.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Cateterismo Periférico , Arteria Femoral , Punciones , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Arteria Femoral/diagnóstico por imagen , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Anciano , Cateterismo Periférico/efectos adversos , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Prótesis Valvulares Cardíacas
2.
Catheter Cardiovasc Interv ; 104(1): 115-124, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38764320

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Recuperación de la Función , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Masculino , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Anciano de 80 o más Años , Anciano , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Resultado del Tratamiento , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo
3.
Catheter Cardiovasc Interv ; 102(2): 339-347, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37232417

RESUMEN

BACKGROUND: Growing interest in neuroprotection in transcatheter aortic valve replacement (TAVR) has catalyzed the development of cerebral protection systems (CPS). OBJECTIVES: Report insights from consecutive real-world patients undergoing TAVR with the Sentinel-CPS. METHODS: Patients with severe aortic stenosis undergoing TAVR from April 2019 to May 2022 were enrolled in a prospective registry. The reason for unsuccessful Sentinel-CPS deployment and the amount of debris captured by the filters were prospectively recorded. RESULTS: The Sentinal CPS was successfully deployed in 330 patients (85%, Group 1). Deployment was not attempted, unsuccessful or only partially successful in 59 patients (15%, Group 2), caused by anatomical factors such as tortuosity, heavy calcification or small dimensions of radial or brachial artery in 46, technical aspects such as puncture failure or dissection in 5 or use of right radial access for the pigtail in 6. Debris was captured in 98% of patients in Group 1. In 40%, the amount of debris was graded moderate or extensive. Predictors for moderate/extensive debris were moderate/severe aortic calcification (OR 1.50, CI 1.05-2.15, p = 0.03), pre- and postdilatation (OR 1.97, CI 1.02-3.79, p = 0.04 and OR 1.71, CI 1.01-2.89, p = 0.048). The risk of stroke was numerically lower in patients who underwent TAVR with the Sentinel CPS (2.1 vs. 5.1%, respectively, p = 0.15). There was no stroke during CPS deployment, but one patient had a stroke immediately after device retrieval. CONCLUSIONS: The Sentinel-CPS was successfully deployed in 85% of patients. Predictors for moderate/extensive debris captured were moderate/severe aortic calcification, pre- and postdilatation.


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Accidente Cerebrovascular/etiología , Factores de Riesgo
4.
Catheter Cardiovasc Interv ; 96(6): E640-E645, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-31971346

RESUMEN

OBJECTIVES: This study aimed to investigate the safety and efficacy of ACURATE neo transcatheter aortic valve replacement (TAVR) facilitated by predilatation with the nonocclusive TrueFlow balloon catheter. BACKGROUND: Now that TAVR is moving forward, physicians have attempted to simplify and streamline the procedure and the so-called minimalist approach has become more popular. METHODS: We enrolled 142 patients (mean age: 82 ± 5 years, 61% female) in a prospective registry. Patients at low risk for intraprocedural third-degree atrioventricular block (AVB) underwent TAVR with the TrueFlow balloon without rapid pacing and without insertion of a provisional pacemaker (n = 121). The remaining 21 patients were predilated with rapid pacing using a provisional pacemaker and a standard balloon. RESULTS: Predilatation with the TrueFlow balloon was successful in all 121 patients. Postdilatation was less frequently required after predilatation with the TrueFlow (25% vs. 57%, p = .003). Moreover, median procedural duration with the TrueFlow was significantly shorter (42 [interquartile range, IQR: 34-53] vs. 55 [IQR: 46-61] min, p = .004). In-hospital outcomes were similar. At 30 days, there was no mortality, two (1%) patients had suffered a stroke and only four (3%) had required implantation of a new pacemaker. CONCLUSION: Among patients with a low risk for intraprocedural third-degree AVB, the TrueFlow nonocclusive balloon catheter facilitates implantation of the ACURATE neo without the necessity of rapid pacing and a provisional pacemaker.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Valvuloplastia con Balón/instrumentación , Catéteres Cardíacos , Cateterismo Periférico , Arteria Femoral , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Bloqueo Atrioventricular/etiología , Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/prevención & control , Valvuloplastia con Balón/efectos adversos , Cateterismo Periférico/efectos adversos , Femenino , Humanos , Masculino , Estudios Prospectivos , Diseño de Prótesis , Recuperación de la Función , Sistema de Registros , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Artículo en Inglés | MEDLINE | ID: mdl-38987046

RESUMEN

BACKGROUND: In patients undergoing transcatheter aortic valve replacement (TAVR), elevated pre-procedural C-reactive protein (CRP) levels are frequently observed. Its impact on long-term results of TAVR is unclear. The aim of the study was to investigate the long-term (up to six years) clinical outcomes of TAVR patients with normal compared to elevated CRP levels before TAVR. METHODS: Consecutive patients undergoing TAVR between August 2012 and January 2023 at a tertiary cardiology facility were included. Patients were divided into two cohorts based on the baseline CRP levels: normal CRP (≤ 5 mg/l) and elevated CRP (>5 mg/l). The cohorts were followed clinically for up to six years after TAVR. RESULTS: From a total of 1000 TAVR patients (mean age 81 ± 6 years), 268 patients (27 %) were found to have elevated baseline CRP (>5 mg/l). Such patients had significantly more co-morbidities (e.g. chronic obstructive pulmonary disease, atrial fibrillation, heart failure, concomitant valvopathies). They also developed periprocedural infections more frequently (3 % vs. 1 %, p = 0.007) and required more commonly repeat hospitalizations for infections during follow-up (HR 1.97, CI 1.47-2.64, p < 0.001). All-cause mortality and development of valve dysfunction did not significantly differ between patients with elevated and normal baseline CRP levels. CONCLUSION: Albeit long-term results of TAVR patients with elevated pre-procedural CRP levels seem favorable in terms of survival and development of valve dysfunction, they have an increased risk for periprocedural infections and re-admissions due to infections of any type during the follow-up period.

6.
J Invasive Cardiol ; 36(4)2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38412438

RESUMEN

OBJECTIVES: Percutaneous closure of a patent foramen ovale (PFO) for the prevention of recurrent paradoxical thromboembolic events has been shown to be safe and effective in randomized controlled trials. However, it remains uncertain if differences in the structure and design of the occluder devices impact the outcomes. The aim of this study was to compare results of percutaneous PFO closure using 2 widely used double-disc occluders. METHODS: Consecutive patients who underwent percutaneous PFO closure with the Abbott Amplatzer occluder (APO) or the Occlutech Figulla-Flex-II occluder (OPO) at the Heart Center Lucerne between February 2017 and December 2022 were included in a registry. The primary endpoint was effective closure of the PFO, defined as a residual shunt grade 0 or 1, assessed by contrast echocardiogram at 6-month follow-up. Secondary endpoints included procedural efficacy/safety and major adverse cardiovascular events during the hospital stay and at 6-month follow-up. RESULTS: One hundred ninety-three consecutive patients (mean age 51.7 ± 12.5 years; 39% women; Risk of Paradoxical Embolism (RoPE) score = 7, IQR = 6-8) underwent percutaneous PFO closure with the APO (120 patients, 62.2%) or the OPO (73 patients, 37.8%). Main indications for closure were crypotogenic stroke in 168 patients (87.1%) and peripheral embolism in 13 patients (6.7%). At baseline, right-to-left shunt (RLS) greater than or equal to grade 2 was present in 189 patients (97.9%). Immediate procedural success was 99.5%. In 1 patient, an air embolism occurred during positioning of the APO occluder with transient chest pain and electrocardiogram changes, but without further sequelae to the patient. At 6-month follow-up, effective closure was achieved in 185 patients (95.8%; APO: 96.6% vs OPO: 94.5%, P = .30). Rates of atrial fibrillation and recurrent thromboembolic events were 4.2 and 0.5%, respectively. CONCLUSIONS: PFO closure is safe and effective when performed with either the self-expanding Abbott Amplatzer or Occlutech Figulla Flex II PFO occluder.


Asunto(s)
Foramen Oval Permeable , Dispositivo Oclusor Septal , Accidente Cerebrovascular , Tromboembolia , Humanos , Femenino , Adulto , Persona de Mediana Edad , Masculino , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/cirugía , Foramen Oval Permeable/complicaciones , Resultado del Tratamiento , Ecocardiografía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Dispositivo Oclusor Septal/efectos adversos , Tromboembolia/etiología , Cateterismo Cardíaco/métodos
7.
J Am Heart Assoc ; 13(5): e032250, 2024 Mar 05.
Artículo en Inglés | MEDLINE | ID: mdl-38390801

RESUMEN

BACKGROUND: Chronic inflammatory disease (CID) accelerates atherosclerosis and the development of aortic stenosis. Data on long-term outcomes after transcatheter aortic valve implantation (TAVI) in those patients are missing. The aim of this study was to investigate the clinical long-term outcomes of patients with and without autoimmune-related CID undergoing TAVI for the treatment of severe aortic stenosis. METHODS AND RESULTS: From a prospective registry, consecutive patients with TAVI were included. Baseline clinic and imaging data (echocardiographic and computed tomography) were analyzed. Long-term (up to 5 years) clinical and echocardiographic outcomes were studied. Of 1000 consecutive patients (mean age 81±6 years, 46% female), 107 (11%) had CID; the most frequent entities included polymyalgia rheumatica (31%) and rheumatoid arthritis (28%). Patients with CID were predominantly female (60% versus 44%, P=0.002) and more often had pulmonary disorders (21% versus 13%, P=0.046) and atrial fibrillation (32% versus 20%, P=0.003). The presence of CID was associated with a higher rate of postinterventional infection (5% versus 1%, P=0.007) and further emerged as a risk factor for rehospitalization for bleeding or infection (hazard ratio, 1.93 and 1.62, respectively). Premature valve degeneration, endocarditis, and all-cause mortality were not increased among patients with CID. CONCLUSIONS: This real-world analysis found that patients with CID undergoing TAVI were associated with a higher risk of postinterventional infectious complications and rehospitalization due to infection. However, valve durability and survival seem not to differ between patients with TAVI with versus without CID.


Asunto(s)
Estenosis de la Válvula Aórtica , Fibrilación Atrial , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo , Fibrilación Atrial/complicaciones , Enfermedad Crónica , Sistema de Registros
8.
Am J Cardiol ; 186: 216-222, 2023 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-36333149

RESUMEN

The increasing prevalence of aortic stenosis (AS) and the increasing number of patients indicated for transcatheter aortic valve implantation (TAVI) can lead to increased hospital constraints. This study aimed to compare, from the hospital perspective, the costs, resource use, and 30-day clinical outcomes of patients who underwent TAVI under an optimized or standard clinical pathway. A single-center, retrospective study was conducted among patients with native AS who underwent TAVI between January 2018 and March 2021. Patients who underwent optimized lean TAVI were propensity-score matched 1:1 to those who underwent standard TAVI. In-hospital costs and 30-day clinical outcomes were compared between the 2 groups. A total of 182 patients (91 in each group) were included in the final analysis. Baseline covariates were well balanced after matching. Patients who underwent lean TAVI had shorter length of stay (median [interquartile range] 3.0 days [2.0 to 6.0] vs 6.0 days [5.0 to 9.0], p <0.001). Patients in the lean TAVI group incurred lower total costs than did those in the standard TAVI group (mean ± SD: $41,346 ± 10,062 vs $50,471 ± 15,115, p = 0.002). There was no between-group difference in 30-day all-cause mortality (2.2% vs 1.1%, p = 0.573) and pacemaker implantations (5.5% vs 6.6%, p = 0.788). Rates of procedural complications were comparable between groups. In conclusion, lean TAVI leads to hospital efficiencies without compromising patient safety. Efforts to streamline the TAVI procedure should be encouraged to improve access to TAVI for patients with AS, amid resource constraints.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Puntaje de Propensión , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo
9.
Struct Heart ; 7(6): 100214, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38046862

RESUMEN

Background: Motion artifacts in planning computed tomography (CT) for transcatheter aortic valve implantation (TAVI) can potentially skew measurements required for procedural planning. Whether such artifacts may affect safety or efficacy has not been studied. Methods: We conducted a retrospective analysis of 852 consecutive patients (mean age, 82 years; 47% women) undergoing TAVI-planning CT at a tertiary care center. Two independent observers divided CTs according to the presence of motion artifacts at the annulus level (Motion vs. Normal group). Endpoints included surrogate markers for inappropriate valve selection: annular rupture, valve embolization or misplacement, need for a new permanent pacemaker, paravalvular leak (PVL), postprocedural transvalvular gradient, all-cause death. Results: Forty-six (5.4%) patients presented motion artifacts on TAVI-planning CT (Motion group). These patients had more preexisting heart failure, moderate-severe mitral regurgitation, and atrial fibrillation. Interobserver variability of annular measurement (Normal vs. Motion group) did not differ for mean annular diameter but was significantly different for perimeter and area. Presence of motion artifacts on planning CT did not affect the prevalence of PVL (≥moderate PVL 0% vs. 2.5% p = 0.5), mean transvalvular gradient (6±3 mmHg vs 7±5 mmHg, p = 0.1), or the need for additional valve implantation (0% vs. 2.8%, p = 0.6). One annular rupture occurred (Normal group). Pacemaker implantation, procedural duration, hospital stay, 30-day outcomes, and all-cause mortality did not differ between the groups. Conclusions: Motion artifacts on planning CT were found in about 5% of patients. Measurements for valve selection were possible without the need for repeat CT, with mean diameter-derived annulus measurement being the most accurate. Motion artifacts were not associated with worse outcomes.

10.
J Invasive Cardiol ; 35(12)2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38108869

RESUMEN

OBJECTIVES: The Allegra-THV is a novel, self-expanding THV with supra-annular bovine leaflets. The valve is available in 3 different sizes and is delivered through an 18 French sheath. To determine the safety and efficacy of the Allegra transcatheter heart valve (THV; Biosensors) for the treatment of severe aortic valve stenosis under real-world conditions. METHODS: Consecutive patients undergoing transcatheter aortic valve replacement (TAVR) at the Heart-Centre Lucerne with the Allegra-THV were included. Echocardiographic data were collected at baseline, before discharge, and at 1-year follow-up; clinical outcomes were recorded for up to 3 years. Clinical endpoints were defined according to the definitions of the Valve-Academic-Research-Consortium. RESULTS: One hundred-three patients (age 81 ± 7 years, 63% women) were enrolled. Median European System for Cardiac Operative Risk Evaluation II score was 4.1% (IQR 1.8%-4.2%). Mean aortic valve gradient was 6.9 ± 3.3 mm Hg and 7.7 ± 3.3 mm Hg, and an effective orifice area was 2.1 ± 0.5 cm2 and 2.0 ± 0.5 cm2 at 30 days and 1-year follow-up, respectively. More than mild paravalvular leak was observed in 2.0% of patients at 30 days and 3.3% at 1 year. At 1-year follow-up, 14.7% of patients required implantation of a new permanent pacemaker, 1 patient had endocarditis with an uneventful clinical course and good THV-function after antibiotic therapy, and no thrombosis, structural-valve-detoriation (SVD), or non-SVD had occurred. At 3-year follow-up, rates of all-cause and cardiovascular mortality were 31.4% and 18.8%, respectively. CONCLUSIONS: Transfemoral implantation of the Allegra-THV resulted in favorable clinical and echocardiographic outcomes at up to 3-year follow-up. Head-to-head randomized clinical trials are necessary to determine if the Allegra-THV valve performs as well as current generation valves.


Asunto(s)
Ecocardiografía , Válvulas Cardíacas , Humanos , Animales , Bovinos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Terfenadina , Catéteres
11.
Am J Cardiol ; 200: 146-152, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37321028

RESUMEN

Subclinical leaflet thrombosis, identified as hypoattenuated leaflet thickening (HALT) on cardiac computed tomography scan, has been observed after transcatheter aortic valve replacement (TAVR). However, data on HALT after the implant of the supra-annular ACURATE neo/neo2 prosthesis are limited. This study aimed to determine the prevalence and risk factors for the development of HALT after TAVR with the ACURATE neo/neo2. A total of 50 patients who received the ACURATE neo/neo2 prosthesis were prospectively enrolled. Patients underwent a contrast-enhanced multidetector row cardiac computed tomography scan at before, after, and 6 months after TAVR. At the 6-month follow-up, HALT was detected in 16% (8 of 50 patients). These patients had a lower implant depth of the transcatheter heart valve (8 ± 2 mm vs 5 ± 2 mm, p = 0.001), less calcified native valve leaflets, a better expansion of the frame at the level of the left ventricular outflow tract, and were less often hypertensive. Thrombosis of the sinus of Valsalva occurred in 18% (9/50). There was no difference in the anticoagulation regimen between patients with and without thrombotic findings. In conclusion, HALT was present in 16% of patients at 6 months follow-up, patients presenting with HALT had a lower implant depth of the transcatheter heart valve, and HALT was detected in patients on oral anticoagulation therapy.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Diseño de Prótesis , Trombosis/diagnóstico por imagen , Trombosis/epidemiología , Trombosis/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología
12.
JACC Cardiovasc Interv ; 16(4): 396-411, 2023 02 27.
Artículo en Inglés | MEDLINE | ID: mdl-36858659

RESUMEN

BACKGROUND: The optimal access route in patients with severe peripheral artery disease (PAD) undergoing transcatheter aortic valve replacement (TAVR) remains undetermined. OBJECTIVES: This study sought to compare clinical outcomes with transfemoral access (TFA), transthoracic access (TTA), and nonthoracic transalternative access (TAA) in TAVR patients with severe PAD. METHODS: Patients with PAD and hostile femoral access (TFA impossible, or possible only after percutaneous treatment) undergoing TAVR at 28 international centers were included in this registry. The primary endpoint was the propensity-adjusted risk of 30-day major adverse events (MAE) defined as the composite of all-cause mortality, stroke/transient ischemic attack (TIA), or main access site-related Valve Academic Research Consortium 3 major vascular complications. Outcomes were also stratified according to the severity of PAD using a novel risk score (Hostile score). RESULTS: Among the 1,707 patients included in the registry, 518 (30.3%) underwent TAVR with TFA after percutaneous treatment, 642 (37.6%) with TTA, and 547 (32.0%) with TAA (mostly transaxillary). Compared with TTA, both TFA (adjusted HR: 0.58; 95% CI: 0.45-0.75) and TAA (adjusted HR: 0.60; 95% CI: 0.47-0.78) were associated with lower 30-day rates of MAE, driven by fewer access site-related complications. Composite risks at 1 year were also lower with TFA and TAA compared with TTA. TFA compared with TAA was associated with lower 1-year risk of stroke/TIA (adjusted HR: 0.49; 95% CI: 0.24-0.98), a finding confined to patients with low Hostile scores (Pinteraction = 0.049). CONCLUSIONS: Among patients with PAD undergoing TAVR, both TFA and TAA were associated with lower 30-day and 1-year rates of MAE compared with TTA, but 1-year stroke/TIA rates were higher with TAA compared with TFA.


Asunto(s)
Ataque Isquémico Transitorio , Enfermedad Arterial Periférica , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Sistema de Registros
15.
Heart ; 104(24): 2058-2066, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30030336

RESUMEN

OBJECTIVES: To investigate the association of the CharlsonComorbidity Index (CCI) with clinical outcomes after transcatheter aortic valve implantation (TAVI). BACKGROUND: Patients undergoing TAVI have high comorbid burden; however, there is limited evidence of its impact on clinical outcomes. METHODS: Data from 1887 patients from the UK, Canada, Spain, Switzerland and Italy were collected between 2007 and 2016. The association of CCI with 30-day mortality, Valve Academic Research Consortium-2 (VARC-2) composite early safety, long-term survival and length of stay (LoS) was calculated using logistic regression and Cox proportional hazard models, as a whole cohort and at a country level, through a two-stage individual participant data (IPD) random effect meta-analysis. RESULTS: Most (60%) of patients had a CCI ≥3. A weak correlation was found between the total CCI and four different preoperative risks scores (ρ=0.16 to 0.29), and approximately 50% of patients classed as low risk from four risk prediction models still presented with a CCI ≥3. Per-unit increases in total CCI were not associated with increased odds of 30-day mortality (OR 1.09, 95% CI 0.96 to 1.24) or VARC-2 early safety (OR 1.04, 95% CI 0.96 to 1.14) but were associated with increased hazard of long-term mortality (HR 1.10, 95% CI 1.05 to 1.16). The two-stage IPD meta-analysis indicated that CCI was not associated with LoS (HR 0.97, 95% CI 0.93 to 1.02). CONCLUSION: In this multicentre international study, patients undergoing TAVI had significant comorbid burden. We found a weak correlation between the CCI and well-established preoperative risks scores. The CCI had a moderate association with long-term mortality up to 5 years post-TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Medición de Riesgo/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Adulto , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/epidemiología , Canadá/epidemiología , Comorbilidad/tendencias , Femenino , Estudios de Seguimiento , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Factores de Riesgo , Índice de Severidad de la Enfermedad , España/epidemiología , Suiza/epidemiología , Factores de Tiempo , Adulto Joven
16.
Circ Cardiovasc Interv ; 11(3): e005727, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29870383

RESUMEN

BACKGROUND: Chronic liver disease is a known risk factor for perioperative morbidity and mortality in patients undergoing cardiac surgery. Very little data exist about such patients treated with transcatheter aortic valve replacement (TAVR). Our objective was to evaluate early and late clinical outcomes in a large cohort of patients with liver disease undergoing TAVR and to determine predictive factors of mortality among these patients. METHODS AND RESULTS: This multicenter study collected data from 114 patients with chronic liver disease who underwent TAVR in 12 institutions. Perioperative and long-term outcomes were compared with a cohort of 1118 patients without liver disease after a propensity score-matching analysis (114 matched pairs). In-hospital mortality and vascular and bleeding complications were similar between matched groups. Acute kidney injury was more common in liver disease group (30.8% versus 13.5%; P=0.010). Although cardiovascular mortality was similar between groups (9.4% versus 6.5%; P=0.433) at 2-year follow-up, noncardiac mortality was higher in the liver group (26.4% versus 14.8%; P=0.034). Lower glomerular filtration rate (hazard ratio, 1.10, for each decrease of 5 mL/min in estimated glomerular filtration rate; 95% confidence interval, 1.03-1.17; P=0.005) and Child-Pugh class B or C (hazard ratio, 3.11; 95% confidence interval, 1.47-6.56; P=0.003) were the predictors of mortality in patients with chronic liver disease, with a mortality rate of 83.2% at 2-year follow-up in patients with both factors (estimated glomerular filtration rate <60 mL/min and Child-Pugh B or C). CONCLUSIONS: These findings suggested that TAVR is a feasible treatment for severe aortic stenosis in patients with early-stage liver disease or as bridge therapy before a curative treatment of the hepatic condition. Patients with Child-Pugh class B-C, especially in combination with renal impairment, had a very low survival rate, and TAVR should be carefully considered to avoid a futile treatment. These results may contribute to improve the clinical decision-making process and management in patients with liver disease.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cirrosis Hepática/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Canadá , Enfermedad Crónica , Toma de Decisiones Clínicas , Europa (Continente) , Estudios de Factibilidad , Femenino , Humanos , Cirrosis Hepática/diagnóstico , Cirrosis Hepática/terapia , Masculino , Complicaciones Posoperatorias/mortalidad , Puntaje de Propensión , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS