1.
Sensors (Basel) ; 23(16)2023 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-37631594

RESUMEN

Noninvasive remote monitoring of hemodynamic variables is essential in optimizing treatment opportunities and predicting rehospitalization in patients with congestive heart failure. The objective of this study is to develop a wearable bioimpedance-based device, which can provide continuous measurement of cardiac output and stroke volume, as well as other physiological parameters for a greater prognosis and prevention of congestive heart failure. The bioimpedance system, which is based on a robust and cost-effective measuring principle, was implemented in a CMOS application specific integrated circuit, and operates as the analog front-end of the device, which has been provided with a radio-frequency section for wireless communication. The operating parameters of the proposed wearable device are remotely configured through a graphical user interface to measure the magnitude and the phase of complex impedances over a bandwidth of 1 kHz to 1 MHz. As a result of this study, a cardiac activity monitor was implemented, and its accuracy was evaluated in 33 patients with different heart diseases, ages, and genders. The proposed device was compared with a well-established technique such as Doppler echocardiography, and the results showed that the two instruments are clinically equivalent.


Asunto(s)
Cardiopatías , Insuficiencia Cardíaca , Dispositivos Electrónicos Vestibles , Masculino , Humanos , Femenino , Insuficiencia Cardíaca/terapia , Corazón , Gasto Cardíaco
2.
Eur J Vasc Endovasc Surg ; 60(3): 395-401, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-32665199

RESUMEN

OBJECTIVE: The objective of this prospective single centre study was to assess whether branches and fenestrations have different outcomes on renal function in the early phase. METHODS: From March 2018 to June 2019, 67 patients who underwent elective fenestrated and branched endovascular aneurysm repair (F/BEVAR) procedures were enrolled in this study. The patients were divided into two groups according to the renal bridging component configuration (fenestration vs. branch). All of them underwent dynamic renal scintigraphy with 99mTc diethylenetriaminepentaacetic acid (DTPA), two weeks pre-operatively, and three months and one year post-operatively. The primary end points were peri-procedural technical success, 30 day major adverse events, differences in glomerular filtration rate (GFR) between the branch and fenestration configurations, and variations between the pre-operative and the post-operative dynamic renal scintigraphy. RESULTS: Overall, 135 kidneys were analysed: 63 in the 32 patients treated with fenestrations, and 72 in the 35 patients treated with branches; the mean GFR on baseline scintigraphy was 58.4 ± 30.9 mL/min in the fenestration group, and 65.1 ± 29.2 mL/min in the branch group. Only kidneys associated with a patent fenestration/branch were included in the split GFR final analysis. The mean total GFR at three month scintigraphy decreased by 6.0 ± 2.9 mL/min in the fenestration group and by 23.4 ± 6.4 mL/min in the branch group. The split GFR decreased by 3.5 ± 0.6 mL/min in the fenestration group, and by 15.4 ± 5.4 mL/min in the branch group. The GFR decrease remained stable at one year. CONCLUSION: In this study, the use of branches for renal arteries during F/BEVAR resulted in a greater decrease in the GFR than in those patients who were treated with fenestrations alone. The scintigraphic alterations were evident at an early phase.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Enfermedades Renales/diagnóstico por imagen , Cintigrafía , Arteria Renal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Tasa de Filtración Glomerular , Humanos , Enfermedades Renales/etiología , Enfermedades Renales/fisiopatología , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Radiofármacos/administración & dosificación , Arteria Renal/diagnóstico por imagen , Arteria Renal/fisiopatología , Pentetato de Tecnecio Tc 99m/administración & dosificación , Factores de Tiempo , Resultado del Tratamiento
3.
Ann Vasc Surg ; 69: 454.e7-454.e11, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32768550

RESUMEN

Small-sized vessels can represent a contraindication to standard endovascular aortic repair (EVAR), and more specifically, aortoiliac deformities resulting from poliomyelitis may add an adjunctive challenge for total endovascular repair. Herein we report a case of a 62-year-old man with a 55 mm abdominal aortic aneurysm (AAA) and a history of poliomyelitis. More specifically, a computed tomography angiogram (CTA) showed a very narrow infrarenal aortic neck, measuring 13 mm in maximum diameter, and severely atrophic external iliac and common femoral arteries. A total endovascular repair was planned and realized with a single aortic JOTEC iliac branch and contralateral VBX placement. All prosthetic materials were delivered from the nonatrophic side. At the 1-year CTA, the aneurysm was successfully excluded and both iliofemoral axes were patent.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Poliomielitis/complicaciones , Stents , Anciano , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Atrofia , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/patología , Masculino , Poliomielitis/diagnóstico , Poliomielitis/virología , Resultado del Tratamiento
4.
Ann Vasc Surg ; 57: 266-271, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30684615

RESUMEN

BACKGROUND: The aim of this study is to report the Destino-guided branched endovascular aortic repair approach as a valid alternative to catheterization downward branches in complex aortic arch/descending thoracic anatomies. METHODS & RESULTS: A 53-year-old woman with Marfan syndrome underwent a thoracoabdominal aortic aneurysm (TAAA) repair for a type III dissecting aneurysm. A custom repair with an endograft having 3 fenestrations (for renal arteries and superior mesenteric artery) and 1 branch for the celiac trunk was planned. The right axillary artery was chronically occluded; the left subclavian artery (LSA) was aneurysmatic. The catheterization of the celiac trunk branch was demanding but ultimately a bare stent was used as a bridging component between the graft and the target vessel, for spinal cord preconditioning. At the 2-month computed tomography angiography, when planning the relining of the bare metal stent, a 1 cm increase in diameter of the LSA aneurysm was documented and therefore a Destino-guided branched endovascular aortic repair was planned. This approach consists of branch catheterization via femoral access using the Destino steerable guiding sheath inside which, after bending, a smaller Cook Flexor is placed to easily deliver the stent, while maintaining stability. CONCLUSIONS: The Destino-guided branched endovascular aortic repair is a reproducible and effective alternative to the classic catheterization of side branches via brachial/axillary access allowing their completion from a femoral access.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Cateterismo Periférico/instrumentación , Procedimientos Endovasculares/instrumentación , Arteria Femoral , Dispositivos de Acceso Vascular , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/etiología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/etiología , Aortografía/métodos , Prótesis Vascular , Angiografía por Tomografía Computarizada , Diseño de Equipo , Femenino , Arteria Femoral/diagnóstico por imagen , Humanos , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Persona de Mediana Edad , Punciones , Resultado del Tratamiento
5.
J Endovasc Ther ; 25(6): 726-734, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30280649

RESUMEN

PURPOSE:: To evaluate the safety and performance of the Treovance stent-graft. METHODS:: The global, multicenter RATIONALE registry ( ClinicalTrials.gov; identifier NCT03449875) prospectively enrolled 202 patients (mean age 73.0±7.8 years; 187 men) with abdominal aortic aneurysms (AAA) suitable for endovascular aneurysm repair (EVAR) using the Treovance. The composite primary safety endpoint was site-reported all-cause mortality and major morbidity. The primary efficacy outcome was clinical success. Further outcomes evaluated included technical success; stent-graft migration, patency, and integrity; endoleak; and aneurysm size changes. RESULTS:: Technical success was 96% (194/202); 8 patients had unresolved type I endoleaks at the end of the procedure. There was no 30-day mortality and 1% major morbidity (1 myocardial infarction and 1 bowel ischemia). Clinical success at 1 year was confirmed in 194 (96%) patients; 6 of 8 patients had new/persistent endoleaks and 2 had aneurysm expansion without identified endoleak. A total of 8 (4%) reinterventions were required during the mean 13.7±3.1 months of follow-up (median 12.8). At 1 year, the Kaplan-Meier estimate for freedom from reintervention was 95.6% (95% CI 91.4% to 97.8%). Other estimates were 95.5% (95% CI 91.7% to 97.6%) for freedom from endoleak type I/III and 97.4% (95% CI 94.2% to 98.9%) for freedom from aneurysm expansion. Thirteen (6.4%) patients died; no death was aneurysm related. CONCLUSION:: The RATIONALE registry showed favorable safety and clinical performance of the Treovance stent-graft for the treatment of infrarenal AAAs in a real-world setting.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Vigilancia de Productos Comercializados , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
G Ital Med Lav Ergon ; 34(1 Suppl A): A34-40, 2012.
Artículo en Italiano | MEDLINE | ID: mdl-22888720

RESUMEN

INTRODUCTION: the purpose was to investigate and describe the subjective burden perceived by caregivers of elderly patients affected by multiple pathologies admitted to an acute ward and to consider the necessity of intervention with special reference to the analysis of psychological support need. METHODS: a sample of 100 caregivers of elderly patients admitted to Geriatrics ward was interviewed using two instruments assessing care burden: the Family Strain Questionnaire--Short Form (FSQ-SF) and the Anxiety and Depression Short Scale (AD-R). RESULTS: the FSQ-SF highlighted that 7% of caregivers showed adequate coping abilities to face the stress related to illness; 21% of caregivers could require psychological counselling intervention; for 48% an intervention of psychological evaluation and support was recommended; for 24% the psychological intervention became urgent. Results from the AD-R showed that 36% and 10.5% of interviewed caregivers felt clinically significant levels of anxiety and depression. Despite psychological support need was widely spread (93%), only 35% of caregivers would like to go to a specialist, 18% would like to have more information about how to receive individual psychological support. CONCLUSIONS: results from caregiver burden analysis highlight a paradox which can be defined as an unexpressed need by family members: needing more support from health care services doesn't turn into a tangible demand for intervention. This remark raises some questions: understanding the reasons of such refusing behaviour towards the opportunity of applying specialists in psychological support and identifying which health services could be improved in order to satisfy caregivers needs.


Asunto(s)
Cuidadores/psicología , Rol Profesional , Psicología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Necesidades y Demandas de Servicios de Salud , Unidades Hospitalarias , Humanos , Masculino , Persona de Mediana Edad
7.
J Vasc Surg Cases Innov Tech ; 5(4): 576-579, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31867474

RESUMEN

A 66-year-old man arrived at our emergency department 3 years after an endovascular aneurysm sealing procedure performed at another center. Computed tomography angiography showed distal migration of a Nellix endoprosthesis (Endologix, Irvine, Calif) and a posterior contained rupture. The left kidney was excluded by an occluded iliac-left renal bypass, which was performed at the time of the Nellix implantation because of unintended coverage. A t-Branch (Cook Medical, Bloomington, Ind) was implanted in an emergency, but the delivery caused disruption of the Nellix limb, requiring relining. Target vessels were bridged with VBX stents (W. L. Gore & Associates, Flagstaff, Ariz). The postoperative course was uneventful except for renal function impairment that was restored 2 weeks later.

8.
Stud Health Technol Inform ; 189: 59-64, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23739358

RESUMEN

Miniaturized, noninvasive, wearable sensors constitute a fundamental prerequisite for pervasive, predictive, and preventive healthcare systems. In this sense, this paper presents the design, realization, and evaluation of a wireless multi-channel measurement system based on a cost-effective high-performance integrated circuit for electrical bioimpedance (EBI) measurements in the frequency range from 1 kHz to 1 MHz. The resulting on-chip spectrometer provides high measuring EBI capabilities and together with a low-cost, commercially available radio frequency transceiver device. It provides reliable wireless communication, constitutes the basic node to build EBI wireless sensor networks (EBI-WSNs). The proposed EBI-WSN behaves as a high-performance wireless multi-channel EBI spectrometer, where the number of channels is completely scalable and independently configurable to satisfy specific measurement requirements of each individual. A prototype of the EBI node leads to a very small printed circuit board of approximately 8 cm2 including chip-antenna, which can operate several years on one 3-V coin cell battery and make it suitable for long-term preventive healthcare monitoring.


Asunto(s)
Redes de Comunicación de Computadores/instrumentación , Diagnóstico por Computador/instrumentación , Monitoreo Ambulatorio/instrumentación , Pletismografía de Impedancia/instrumentación , Medicina de Precisión/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Tecnología Inalámbrica/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Miniaturización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA