Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Bioengineering (Basel) ; 11(1)2024 Jan 20.
Artículo en Inglés | MEDLINE | ID: mdl-38275579

RESUMEN

Spinal endoscopy has evolved significantly since its inception, offering minimally invasive solutions for various spinal pathologies. This study introduces a promising innovation in spinal endoscopy-a single-use digital endoscope designed to overcome the drawbacks of traditional optic endoscopes. Traditional endoscopes, despite their utility, present challenges such as fragility, complex disinfection processes, weight issues, and susceptibility to mechanical malfunctions. The digital endoscope, with its disposable nature, lighter weight, and improved image quality, aims to enhance surgical procedures and patient safety. The digital endoscope system comprises a 30-degree 1000 × 1000 pixel resolution camera sensor with a 4.3 mm working channel, and LED light sources replacing optical fibers. The all-in-one touch screen tablet serves as the host computer, providing portability and simplified operation. Image comparisons between the digital and optic endoscopes revealed advantages in the form of increased field of view, lesser distortion, greater close-range resolution, and enhanced luminance. The single-use digital endoscope demonstrates great potential for revolutionizing spine endoscopic surgeries, offering convenience, safety, and superior imaging capabilities compared to traditional optic endoscopes.

2.
Bioengineering (Basel) ; 11(4)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38671799

RESUMEN

OBJECTIVES: This study aimed to establish reference values for fetal aortic isthmus blood flow velocity and associated indices during the first trimester, utilizing a novel ultrasonographic technique known as high-definition flow imaging (HDFI). Additionally, the correlation between Doppler profiles of aortic blood flow and key fetal parameters, including nuchal thickness (NT), crown-rump length (CRL), and fetal heartbeat (FHB), was investigated. METHODS: A total of 262 fetuses were included in the analysis between December 2022 and December 2023. Utilizing 2D power Doppler ultrasound images, aortic blood flow parameters were assessed, including aortic peak systolic velocity (PS), aortic end-diastolic velocity (ED), aortic time average maximal velocity (TAMV), and various indices such as aortic systolic velocity/diastolic velocity (S/D), aortic pulsatile index (PI), aortic resistance index (RI), aortic isthmus flow velocity index (IFI), and aortic isthmic systolic index (ISI). Concurrently, fetal FHB, NT, and CRL were evaluated during early trimester Down syndrome screening. RESULTS: Significant findings include a positive correlation between gestational age (GA) and PS (PS = 3.75 × (GA) - 15.4, r2 = 0.13, p < 0.01), ED (ED = 0.42 × (GA) - 0.61, r2 = 0.04, p < 0.01), PI (PI = 0.07 × (GA) + 1.03, r2 = 0.04, p < 0.01), and TAMV (TAMV = 1.23 × (GA) - 1.66, r2 = 0.08, p < 0.01). In contrast, aortic ISI demonstrated a significant decrease (ISI = -0.03 × (GA) + 0.57, r2 = 0.05, p < 0.05) with gestational age. No significant correlation was observed for aortic RI (p = 0.33), S/D (p = 0.39), and IFI (p = 0.29) with gestational age. Aortic PS exhibited positive correlations with NT (0.217, p = 0.001) and CRL (0.360, p = 0.000) but a negative correlation with FHB (-0.214, p = 0.001). Aortic PI demonstrated positive correlations with CRL (0.208, p = 0.001) and negative correlations with FHB (-0.176, p = 0.005). Aortic TAMV showed positive correlations with NT (0.233, p = 0.000) and CRL (0.290, p = 0.000) while exhibiting a negative correlation with FHB (-0.141, p = 0.026). Aortic ISI demonstrated negative correlations with NT (-0.128, p = 0.045) and CRL (-0.218, p = 0.001) but a positive correlation with FHB (0.163, p = 0.010). CONCLUSIONS: Power Doppler angiography with Doppler ultrasound demonstrates the ability to establish accurate reference values for fetal aortic blood flow during the first trimester of pregnancy. Notably, aortic PS, TAMV, and ISI exhibit significant correlations with NT, CRL, and FHB, with ISI appearing more relevant than IFI, PS, TAMV, and FHB. The utilization of HDFI technology proves advantageous in efficiently detecting the site of the aortic isthmus compared to traditional color Doppler mode in early second trimesters.

3.
Bioengineering (Basel) ; 10(7)2023 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-37508822

RESUMEN

Osteoporosis-induced vertebral compression fracture (OVCF) occurs commonly in people over the age of 50, especially among menopausal women. Besides conservative therapy, minimally invasive percutaneous vertebroplasty (PVP) and kyphoplasty (PKP) have been widely used in clinical treatment and achieved good efficacy. However, the leakage of bone cement (CL) during vertebroplasty (PV) is a major risk that can cause (serious) complications such as compression of the spinal cord, pulmonary embolism, or even paraplegia. In this study, we introduced a new aspiration technique with standard PV procedures (APV) to ameliorate the risk of leakage with quantitative verifications of its effectiveness. APV intends to create a differential pressure to guide the direction of cement flow within the vertebrae. To test this technique, Nubian goats' ex vivo vertebral bodies (VBs) were used to simulate the PV surgical process in humans. Results show that the proposed APV has a lower leakage rate of 13% compared to the 53% of conventional PV. Additionally, the APV approach achieves more uniform cement distribution via the 9-score method with a value of 7 ± 1.30 in contrast to 4 ± 1.78 by conventional PV.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA