RESUMEN
OBJECTIVES: Detection of antinuclear antibodies (ANA) by indirect immunofluorescence assay using HEp-2 cells (HEp-2 IFA) is used to screen for various autoimmune diseases. HEp-2 IFA suffers from variability, which hampers harmonization. METHODS: A questionnaire was developed to collect information on HEp-2 IFA methodology, computer-assisted diagnosis (CAD) systems, training, inter-observer variability, quality assessment, reagent lot change control, and method verification. The questionnaire was distributed to laboratories by Sciensano (Belgium), national EASI groups (Italy, Croatia, Portugal, Estonia, Greece) and ICAP (worldwide). Answers were obtained by 414 laboratories. The results were analysed in the framework of the recent EFLM/EASI/ICAP ANA recommendations (companion paper). RESULTS: Laboratories used either HEp-2, HEp-2000, or HEp-20-10 cells and most laboratories (80%) applied the same screening dilution for children and adults. The conjugate used varied between laboratories [IgG-specific (in 57% of laboratories) vs. polyvalent]. Sixty-nine percent of CAD users reviewed the automatic nuclear pattern and 53% of CAD users did not fully exploit the fluorescence intensity for quality assurance. Internal quality control was performed by 96% of the laboratories, in 52% of the laboratories only with strongly positive samples. Interobserver variation was controlled by 79% of the laboratories. Limited lot-to-lot evaluation was performed by 68% of the laboratories. Method verification was done by 80% of the respondents. CONCLUSIONS: Even though many laboratories embrace high-quality HEp-2 IFA, substantial differences in how HEp-2 IFA is performed and controlled remain. Acting according to the EFLM/EASI/ICAP ANA recommendations can improve the global performance and quality of HEp-2 IFA and nurture harmonization.
Asunto(s)
Anticuerpos Antinucleares , Enfermedades Autoinmunes , Adulto , Niño , Humanos , Anticuerpos Antinucleares/análisis , Técnica del Anticuerpo Fluorescente Indirecta/métodos , Enfermedades Autoinmunes/diagnóstico , Pruebas Inmunológicas , Variaciones Dependientes del ObservadorRESUMEN
BACKGROUND: Chronic kidney disease (CKD) is a major issue in public health. Its prevalence has been calculated using estimation of glomerular filtration rate (GFR) by the creatinine-based equations developed in the Modified Diet in Renal Disease (MDRD) and Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) study. Recently, new equations based either on cystatin C (CKD-EPI Cys) or both cystatin and creatinine (CKD-EPI mix) have been proposed by the CKD-EPI consortium. The aim of this study was to measure the difference in the prevalence of stage 3 CKD, defined as an estimated GFR less than 60 mL/min/1.73 m2, in a population using these four equations. METHODS: CKD screening was performed in the Province of Liège, Belgium. On a voluntary basis, people aged over 50 years have been screened. GFR was estimated by the four equations. Stage 3 CKD was defined as a GFR less than 60 mL/min/1.73 m2. RESULTS: The population screened consisted of 4189 people (47% were men, mean age 63 ± 7y). Their mean serum creatinine and plasma cystatin C levels were 0.88 ± 0.21 mg/dL and 0.85 ± 0.17 mg/L, respectively. The prevalence of CKD in this population using the MDRD, the CKD-EPI, the CKD-EPI Cys and the CKD-EPI mix equations was 13%, 9.8%, 4.7% and 5%, respectively. The prevalence of CKD was significantly higher with the creatinine-based (MDRD and the CKD-EPI) equations compared to the new cystatin C-based equations. CONCLUSIONS: Prevalence of CKD varies strongly depending on the method used to estimate GFR. Such discrepancies are of importance and must be confirmed and explained by additional studies, notably by studies using GFR measured with a reference method. TRIAL REGISTRATION: B70720071509.
Asunto(s)
Creatinina/sangre , Cistatina C/sangre , Tasa de Filtración Glomerular/fisiología , Vigilancia de la Población/métodos , Insuficiencia Renal Crónica/sangre , Insuficiencia Renal Crónica/epidemiología , Anciano , Anciano de 80 o más Años , Bélgica/epidemiología , Biomarcadores/sangre , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Insuficiencia Renal Crónica/diagnósticoRESUMEN
(1) Background: Many vaccines require higher, additional doses or adjuvants to provide adequate protection for people living with HIV (PLWH). Despite their potential risk of severe coronavirus disease 2019, immunological data remain sparse, and a clear consensus for the best booster strategy is lacking. (2) Methods: Using the data obtained from our previous study assessing prospective T-cell and humoral immune responses before and after administration of a third dose of SARS-CoV-2 vaccine, we assessed the correlations between immune parameters reflecting humoral and cellular immune responses. We further aimed at identifying distinct clusters of patients with similar patterns of immune response evolution to determine how these relate to demographic and clinical factors. (3) Results: Among 80 PLWH and 51 healthcare workers (HCWs) enrolled in the study, cluster analysis identified four distinct patterns of evolution characterised by specific immune patterns and clinical factors. We observed that immune responses appeared to be less robust in cluster A, whose individuals were mostly PLWH who had never been infected with SARS-CoV-2. Cluster C, whose individuals showed a particularly drastic increase in markers of humoral immune response following the third dose of vaccine, was mainly composed of female participants who experienced SARS-CoV-2. Regarding the correlation study, although we observed a strong positive correlation between markers mirroring humoral immune response, markers of T-cell response following vaccination correlated only in a lesser extent with markers of humoral immunity. This suggests that neutralising antibody titers alone are not always a reliable reflection of the magnitude of the whole immune response. (4) Conclusions: Our findings show heterogeneity in immune responses among SARS-CoV-2 vaccinated PLWH. Specific subgroups could therefore benefit from distinct immunization strategies. Prior or breakthrough natural infection enhances the activity of vaccines and must be taken into account for informing global vaccine strategies among PLWH, even those with a viro-immunologically controlled infection.
Asunto(s)
COVID-19 , Infecciones por VIH , Humanos , Femenino , Vacunas contra la COVID-19 , Inmunidad Humoral , Estudios Prospectivos , Linfocitos T , COVID-19/prevención & control , SARS-CoV-2 , Análisis por Conglomerados , Infección Irruptiva , Anticuerpos Antivirales , VacunaciónRESUMEN
Background: The faecal calprotectin (FC) measurement is used for inflammatory bowel disease (IBD) diagnosis and follow-up. The aim of this study was to validate for the first time the new IDS FC extraction device and immunoassay kit, and to compare it with the DiaSorin test in patients with and without IBD. Methods: First, the precision of the IDS assay and its stability were assessed. Then, 379 stool extracts were analysed with the IDS kit on iSYS and compared with a DiaSorin Liaison XL assay. Results: The intra- and inter-assay CVs did not exceed 5%. The stool samples were stable up to 4 weeks at −20 °C. Lot-to-lot comparison showed a good correlation (Lot1 = 1.06 × Lot2 + 0.60; p > 0.05). The Passing and Bablok regression showed no significant deviation from linearity between the two methods (IDS = 1.06 × DiaSorin − 0.6; p > 0.05; concordance correlation coefficient = 0.93). According to the recommended cut-offs, the IDS assay identified more IBD and irritable bowel syndrome patients than DiaSorin, which had more borderline results (16 vs. 20%, respectively). Conclusions: The IDS faecal calprotectin had good analytical validation parameters. Compared to the DiaSorin method, it showed comparable results, but slightly outperformed it in the identification of more IBD patients and active disease.
RESUMEN
PURPOSE: To emphasize physio-pathological, clinical and prognosis differences between conditions causing serious and sometimes very similar clinical manifestations: anti-aquaporin-4 (AQP4) and anti-myelin oligodendrocyte glycoprotein (MOG) antibodies related diseases, and seronegative NMOSD (neuromyelitis optica spectrum disorders). METHODS: Based on Wingerchuk et al. (Neurology 85:177-189, 2015) criteria for NMOSD and on those more recently proposed by Jarius et al. (J Neuroinflammation 15:134, 2018) for MOGAD (MOG associated disorders), we retrospectively surveyed 10 AQP4-NMOSD, 8 MOGAD and 2 seronegative NMOSD, followed at the specialized neuroimmunology unit of the CHU Liège. RESULTS: Female predominance was only observed in AQP4 group. Age at onset was 37.8 and 27.7 years old for AQP4-NMOSD and MOGAD respectively. In both groups, the first clinical event most often consisted of optic neuritis (ON), followed by isolated myelitis. Fifteen of our 20 patients encountered a relapsing course with 90% relapses in AQP4-NMOSD, 62.5% in MOGAD and 50% in seronegative group, and a mean period between first and second clinical event of 7.1 and 4.8 months for AQP4-NMOSD and MOGAD, respectively. In total we counted 54 ON, with more ON per patient in MOGAD. MOG-associated ON mainly affected the anterior part of the optic nerve with a papilledema in 79.2% of cases. Despite a fairly good visual outcome after MOG-associated ON, retinal nerve fibre layer (RNFL) thickness decreased, suggesting a fragility of the optic nerve toward further attacks. CONCLUSION: As observed in larger cohorts, our MOGAD and AQP4-NMOSD cases differ by clinical and prognostic features. A better understanding of these diseases should encourage prompt biological screening and hasten proper diagnosis and treatment.
Asunto(s)
Acuaporina 4/inmunología , Glicoproteína Mielina-Oligodendrócito/inmunología , Neuromielitis Óptica/diagnóstico , Neuritis Óptica/diagnóstico , Adulto , Edad de Inicio , Autoanticuerpos/inmunología , Bélgica , Estudios de Cohortes , Femenino , Humanos , Inmunoglobulina G , Masculino , Glicoproteína Asociada a Mielina , Pronóstico , Retina , Estudios RetrospectivosRESUMEN
Background: Understanding and measuring the individual level of immune protection and its persistence at both humoral and cellular levels after SARS-CoV-2 vaccination is mandatory for the management of the vaccination booster campaign. Our prospective study was designed to assess the immunogenicity of the BNT162b2 mRNA vaccine in triggering the cellular and humoral immune response in healthcare workers up to 12 months after the initial vaccination, with one additional boosting dose between 6 and 12 months. Methods: This prospective study enrolled 208 healthcare workers (HCWs) from the Liège University Hospital (CHU) of Liège in Belgium. Participants received two doses of BioNTech/Pfizer COVID-19 vaccine (BNT162b2) and a booster dose 6-12 months later. Fifty participants were SARS-CoV-2 experienced and 158 were naïve before the vaccination. Blood sampling was performed at the day of the first (T0) and second (T1) vaccine doses administration, then at 2 weeks (T2), 4 weeks (T3), 6 months (T4) and 12 months (T5) after the second dose. Between T4 and T5, participants also got the third boosting vaccine dose. A total of 1145 blood samples were collected. All samples were tested for the presence of anti-Spike antibodies, using the DiaSorin LIAISON SARS-CoV-2 Trimeric S IgG assay, and for anti-Nucleocapsid antibodies, using Elecsys anti-SARS-CoV-2 assayââ. Neutralizing antibodies against the SARS-CoV-2 Wuhan-like variant strain were quantified in all samples using a Vero E6 cell-based neutralization assay. Cell-mediated immune response was evaluated at T4 and T5 on 80 and 55 participants, respectively, by measuring the secretion of IFN-γ on peripheral blood lymphocytes using the QuantiFERON Human IFN-γ SARS-CoV-2, from Qiagen. We analyzed separately the naïve and experienced participants. Findings: We found that anti-spike antibodies and neutralization capacity levels were significantly higher in SARS-CoV-2 experienced HCWs compared to naïve HCWs at all time points analyzed except the one after boosting dose. Cellular immune response was also higher in experienced HCWs six months following vaccination. Besides the impact of SARS-CoV-2 infection history on immune response to BNT162b2 mRNA vaccine, we observed a significant negative association between age and persistence of humoral response. The booster dose induced an increase in humoral and cellular immune responses, particularly in naive individuals. Breakthrough infections resulted in higher cellular and humoral responses after the booster dose. Conclusions: Our data strengthen previous findings demonstrating that immunization through vaccination combined with natural infection is better than 2 vaccine doses immunization or natural infection alone. The benefit of the booster dose was greater in naive individuals. It may have implications for personalizing mRNA vaccination regimens used to prevent severe COVID-19 and reduce the impact of the pandemic on the healthcare system. More specifically, it may help prioritizing vaccination, including for the deployment of booster doses.
Asunto(s)
COVID-19 , Vacunas Virales , Anticuerpos Antivirales , Vacuna BNT162 , COVID-19/prevención & control , Vacunas contra la COVID-19 , Humanos , Inmunidad Humoral , Inmunoglobulina G , Cinética , Estudios Prospectivos , SARS-CoV-2 , Vacunas Sintéticas , Vacunas de ARNmRESUMEN
BACKGROUND: Proteinuria has been commonly reported in patients with COVID-19. However, only dipstick tests have been frequently used thus far. Here, the quantification and characterization of proteinuria were investigated and their association with mortality was assessed. METHODS: This retrospective, observational, single center study included 153 patients, hospitalized with COVID-19 between March 28th and April 30th, 2020, in whom total proteinuria and urinary α1-microglobulin (a marker of tubular injury) were measured. Association with mortality was evaluated, with a follow-up until May 7th, 2020. RESULTS: According to the Kidney Disease Improving Global Outcomes staging, 14% (n = 21) of the patients had category 1 proteinuria (< 150 mg/g of urine creatinine), 42% (n = 64) had category 2 (between 150 and 500 mg/g) and 44% (n = 68) had category 3 proteinuria (over 500 mg/g). Urine α1-microglobulin concentration was higher than 15 mg/g in 89% of patients. After a median follow-up of 27 [14;30] days, the mortality rate reached 18%. Total proteinuria and urinary α1-microglobulin were associated with mortality in unadjusted and adjusted models. This association was stronger in subgroups of patients with normal renal function and without a urinary catheter. CONCLUSIONS: Proteinuria is frequent in patients with COVID-19. Its characterization suggests a tubular origin, with increased urinary α1-microglobulin. Tubular proteinuria was associated with mortality in COVID-19 in our restropective, observational study.
Asunto(s)
COVID-19/complicaciones , Proteinuria/epidemiología , Anciano , Anciano de 80 o más Años , Bélgica/epidemiología , Biomarcadores/orina , COVID-19/epidemiología , COVID-19/orina , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Pronóstico , Proteinuria/etiología , Proteinuria/orina , Estudios Retrospectivos , Tasa de Supervivencia/tendenciasRESUMEN
Recently, anti-deamidated gliadin antibodies were proposed for the serological diagnosis of celiac disease. We evaluate the specificity of different anti-deamidated gliadin antibodies ELISA in comparison with conventional anti-native gliadin kits. Serum samples from 46 non celiac patients were analyzed by five different quantitative ELISA for anti-native gliadin, anti-deamidated gliadin and anti-transglutaminase neo-epitope antibodies together with a screening ELISA. Twenty-four percent of the patients demonstrated anti-native gliadin IgA and 63% IgG antibodies. Using anti-deamidated gliadin antibodies, the number of false positive IgA and, particularly, IgG results, markedly decreased in the non celiac patients: 21 and 24% respectively with anti-Gliadin (GAF-3X) Euroimmun kit, 7 and 26% with Bindazyme Human Anti-Gliadin (MGP) The Binding Site kit and 0 and 41% with Celiac G+ Immco kit. The new assay which makes use of the physiological complex of tissue transglutaminase cross-linked with deamidated gliadin peptides, called neo-epitope, did not improve the differential diagnosis of celiac disease with 30% of false positive results in IgG (2% in IgA). Using the Inova screening kit, a positive result for IgA and/or IgG anti-deamidated gliadin and/or anti-tissue transglutaminase antibodies was obtained in 24% of the non celiac patients. In conclusion, our study assessed the superiority, in terms of specificity, of anti-deamidated gliadin antibodies, over the conventional anti-gliadin antibodies for the differential diagnosis of celiac disease.
Asunto(s)
Anticuerpos/sangre , Enfermedad Celíaca/sangre , Gliadina/inmunología , Autoanticuerpos/sangre , Enfermedad Celíaca/diagnóstico , Enfermedad Celíaca/inmunología , Ensayo de Inmunoadsorción Enzimática , Epítopos/inmunología , Reacciones Falso Positivas , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Sensibilidad y Especificidad , Transglutaminasas/inmunologíaRESUMEN
BACKGROUND: The International Consensus on Antinuclear Antibody (ANA) Patterns (ICAP) has recently proposed nomenclature in order to harmonize ANA indirect immunofluorescence (IIF) pattern reporting. ICAP distinguishes competent-level from expert-level patterns. A survey was organized to evaluate reporting, familiarity, and considered clinical value of ANA IIF patterns. METHODS: Two surveys were distributed by European Autoimmunity Standardization Initiative (EASI) working groups, the International Consensus on ANA Patterns (ICAP) and UK NEQAS to laboratory professionals and clinicians. RESULTS: 438 laboratory professionals and 248 clinicians from 67 countries responded. Except for dense fine speckled (DFS), the nuclear competent patterns were reported by > 85% of the laboratories. Except for rods and rings, the cytoplasmic competent patterns were reported by > 72% of laboratories. Cytoplasmic IIF staining was considered ANA positive by 55% of clinicians and 62% of laboratory professionals, with geographical and expertise-related differences. Quantification of fluorescence intensity was considered clinically relevant for nuclear patterns, but less so for cytoplasmic and mitotic patterns. Combining IIF with specific extractable nuclear antigens (ENA)/dsDNA antibody testing was considered most informative. Of the nuclear competent patterns, the centromere and homogeneous pattern obtained the highest scores for clinical relevance and the DFS pattern the lowest. Of the cytoplasmic patterns, the reticular/mitochondria-like pattern obtained the highest scores for clinical relevance and the polar/Golgi-like and rods and rings patterns the lowest. CONCLUSION: This survey confirms that the major nuclear and cytoplasmic ANA IIF patterns are considered clinically important. There is no unanimity on classifying DFS, rods and rings and polar/Golgi-like as a competent pattern and on reporting cytoplasmic patterns as ANA IIF positive.
RESUMEN
BACKGROUND: The prevalence of stage 3 chronic kidney disease (CKD) is increasing, calculated using the modification of diet in renal disease (MDRD) study equation for estimating glomerular filtration rate (GFR). Cystatin C-based equations are also being used to estimate GFR. Using creatinine-based and cystatin C-based equations, the aim of our study was to measure the difference in prevalence of stage 3 CKD in a population. METHODS: CKD screening is organized in the Province of Liege, Belgium. On a voluntary basis, people aged between 45 and 75 years are invited for screening. GFR is estimated using the MDRD study equation and by the three recent cystatin C-based equations proposed by Levey's group. The Levey 1 equation is based on cystatin C only and the Levey 2 equation on cystatin C corrected for age and sex. The Levey 3 equation combines cystatin C, creatinine, age and sex. RESULTS: The population screened comprised 754 people. Cystatin C is highly correlated with creatinine (r = 0.6196, p<0.0001). Prevalence of stage 3 CKD when GFR is estimated by the MDRD equation study is 17.2%, which is significantly and much higher than the prevalence obtained when cystatin C-based equations are used. Indeed, prevalence is 2%, 3.3% and 5.8% with the Levey 1, 2 and 3 equations, respectively. CONCLUSIONS: The prevalence of stage 3 CKD varies strongly following the method used for estimating GFR, creatinine-based or cystatin C-based equations. Such discrepancies must be confirmed and explained in additional studies using GFR measured with a reference method.
Asunto(s)
Creatinina/sangre , Cistatina C/sangre , Enfermedades Renales/epidemiología , Tamizaje Masivo/métodos , Anciano , Enfermedad Crónica , Femenino , Tasa de Filtración Glomerular , Humanos , Enfermedades Renales/diagnóstico , Masculino , Persona de Mediana Edad , PrevalenciaRESUMEN
INTRODUCTION: Determination of creatinine and estimation of Glomerular Filtration Rate (GFR) rapidly before injection of contrast media provides early detection of high-risk patients for acute kidney failure. Hence, a rapid point-of-care (POC) device (result in 30â¯s) allowing creatinine measurement and eGFR could be of interest. To validate this method, we considered a population referred for measuring GFR. METHODS: Iohexol plasma clearance was used to measure GFR. For each subject, enzymatic creatinine was quantified with two different devices: in plasma with the Roche Cobas analyzer and in capillary blood with the Nova Biomedical POC device. Both values of creatinine were used in the CKD-EPI equation for estimated glomerular filtration rate (eGFR). eGFR using POC was compared to eGFR using Cobas and to mGFR by Passing Bablok regression, calculation of bias, precision and accuracy (or concordance) within 30%. Also, we calculated the rate of discrepant staging (eGFR >60 orâ¯≤â¯60 when mGFR is actually ≤60 andâ¯>â¯60) with both creatinine methods. RESULTS: 120 subjects (52⯱â¯13â¯years, 49% of women) were included. Mean mGFR was 77⯱â¯27â¯mL/min/1.73m2 with 29 patients presenting mGFR <60â¯mL/min/1.73m2. Passing- Bablok regression comparing eGFR obtained with the POC and the Cobas was: eGFRPOCâ¯=â¯-0.1 (95% CI: -7.4; 3.0)â¯+â¯1.06 (95% CI: 1.00; 1.15) x eGFRCOBAS. Mean bias was 3.7⯱â¯14.1â¯mL/min/1.73m2. Concordance within 30% was 82%. Compared to mGFR, Passing-Bablok with POC was: eGFRPOCâ¯=â¯-11.5 (95% CI: -22.9; -0.7)â¯+â¯1.15 (95% CI: 1.02; 1.29) x mGFR. Mean bias was 0.1⯱â¯17.6â¯mL/min/1.73m2. Accuracy within 30% was 81%. Between eGFRCOBAS and mGFR, mean bias was -3.7⯱â¯12.5â¯mL/min/1.73m2. Accuracy within 30% was 95%. With POC (and Cobas), 3.3% (0.8%) of patients would have been considered with GFRâ¯>â¯60â¯mL/min/1.73m2 whereas mGFR it was ≤60 and 10% (9.2%) of them would have been considered with GFR ≤60â¯mL/min/1.73m2 when mGFR was >60. CONCLUSION: Creatinine measured with the POC has an acceptable performance when used with the CKD-EPI equation to estimate GFR. Its ability to detect GFR <60â¯mL/min/1.73m2 is not significantly different from the classical Roche assay. StatSensor Creatinine (Nova Biomedical) can be used for GFR screening before contrast media injection.
Asunto(s)
Creatinina/sangre , Tasa de Filtración Glomerular , Yohexol/química , Sistemas de Atención de Punto , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios ProspectivosRESUMEN
BACKGROUND: Cystatin C-based equations are used to estimate GFR. However, three cystatin C immunoassays are on the market. Difference in cystatin C assays could have strong consequences on the accuracy and precision of cystatin C-based equations. We have performed an analytical study of these three assays and studied potential differences between assays on the precision of cystatin C-based equations. METHODS: We have studied imprecision, recovery, linearity and interferences of the three immunoassays (nephelometric assay from Siemens and turbidimetric assays from Dako and Gentian). The impact of differences in cystatin C assays has been studied for the equations published by Levey (Siemens assay) and Grubb (Dako assay). RESULTS: Analytical performance of the Dako assay is slightly less high. For cystatin C values below 2.5 mg/L, no statistical difference is found between results given by the Dako and the Gentian assays. So, both assays can be used in the Grubb equation. Cystatin C results are different with the Siemens assay. The Levey equation, built with the Siemens assay, can only be used with cystatin C values measured with this assay. Using the Dako or Gentian assay results in the Levey equation can lead to differences in estimating GFR up to 6 mL/min/1.73 m2. Differences can reach 9.5 mL/min/1.73 m2 if the Siemens assay is used in the Grubb equation. CONCLUSION: The Siemens and Gentian assays seem analytically more valid than the Dako assay for cystatin C determination. Differences in cystatin C assays can lead to significant differences in cystatin C-based equations. However, these differences seem less important than the differences observed with creatinine and creatinine-based equations.
Asunto(s)
Cistatina C/análisis , Tasa de Filtración Glomerular/fisiología , Algoritmos , Calibración , Creatina/sangre , Hemoglobinas/análisis , Humanos , Inmunoensayo , Nefelometría y Turbidimetría , Valor Predictivo de las Pruebas , Juego de Reactivos para Diagnóstico , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Serum kappa and lambda free light chains (FLC) are useful in the diagnosis, prognosis and monitoring of patients with monoclonal gammopathies. The Binding Site and Siemens were the only suppliers of kits for these analyses until recently, when Sebia introduced an enzyme-linked immunosorbent assay (ELISA) on an automated instrument, DAS AP22 ELITE. METHOD: Samples from routine analysis, controls and chronic kidney disease (CKD) patients were tested using the automated version of Sebia FLC ELISA with the AP22 ELITE and results were compared with Freelite on the SPA PLUS (The Binding Site). RESULTS: Sebia FLC ELISA showed a good performance using the AP22 ELITE. A concordance of 82% was found with the results obtained with Freelite. Sebia FLC is a reproducible assay, requiring less retesting than Freelite thanks to a broader range. Earlier findings that the results obtained are closer to the FLC monoclonal band measured by electrophoresis were confirmed. Higher kappa and lambda values obtained in CKD individuals were also shown, confirming that a kappa/lambda FLC ratio should be introduced by Sebia for CKD patients, as with The Binding Site. CONCLUSIONS: Sebia put forward new technology that automatically measures free light chains. This technique is suitable for routine use; however, the results cannot be used interchangeably with Freelite kits.
Asunto(s)
Ensayo de Inmunoadsorción Enzimática , Cadenas Ligeras de Inmunoglobulina/sangre , Insuficiencia Renal Crónica/sangre , Automatización , Humanos , Insuficiencia Renal Crónica/diagnósticoRESUMEN
OBJECTIVE: The conversion of Hashimoto's thyroiditis (HT) to hyperthyroidism due to thyrotropin receptor antibodies is intriguing and considered rare. The contribution of TSH receptor blocking antibodies (TRAb), which may be stimulators (TSAb) or blockers (TBAb), is suspected. We describe clinical and biological variables in a series of patients switching from Hashimoto's thyroiditis to Grave's disease. SUBJECTS AND METHODS: Retrospective case study of 24 patients with Hashimoto's thyroiditis followed during 48 ± 36 months that developed later Graves' disease (GD). These variables were analysed in the hypo and hyperthyroid phase: age, sex, initial TSH, free triiodothyronine (fT3), free thyroxine (fT4), anti-TPO, TBII antibodies, parietal cell autoantibodies, time between hypo and hyperthyroidism, thyroid volume and levothyroxine doses (LT). RESULTS: In HT, mean TSH was 9.4 ± 26.1 UI/L and levothyroxine treatment was 66.2 ± 30.8 µg/day. The switch to GD was observed 38 ± 45 months after HT diagnosis. As expected, we found significant differences on TSH, FT3, FT4 and TBAb levels. Three out of 14 patients had parietal cell autoantibodies. In two of these three cases there was an Helicobacter pylori infection. There were no significant differences between HT and GD groups with respect to thyroid volume. CONCLUSIONS: To our knowledge, large series documenting the conversion of HT to GD are scarce. Although rare, this phenomenon should not be misdiagnosed. Suspicion should be raised whenever thyroxine posology must be tapered down during the follow-up of HT patients. Further immunological and genetic studies are needed to explain this unusual autoimmune change.
Asunto(s)
Enfermedad de Graves/inmunología , Enfermedad de Hashimoto/inmunología , Inmunoglobulinas Estimulantes de la Tiroides/inmunología , Receptores de Tirotropina/inmunología , Adulto , Autoanticuerpos/inmunología , Femenino , Enfermedad de Graves/sangre , Enfermedad de Hashimoto/sangre , Humanos , Hipotiroidismo/inmunología , Inmunoglobulinas Estimulantes de la Tiroides/sangre , Mediciones Luminiscentes , Masculino , Persona de Mediana Edad , Receptores de Tirotropina/sangre , Estudios Retrospectivos , Estadísticas no Paramétricas , Pruebas de Función de la Tiroides , Tirotropina/sangre , Tiroxina/administración & dosificación , Tiroxina/sangre , Triyodotironina/sangre , Adulto JovenRESUMEN
Although it remained controversial for a long time, central nervous system (CNS) involvement of graft-versus-host disease (GVHD) is now becoming recognized as a real nosological entity. Previous case reports have suggested heterogeneous clinical presentations and it is not excluded that the whole spectrum of manifestations has not yet been fully described. Here, we report the case of a 58-year-old man with chronic GVHD who developed a rapidly ingravescent encephalopathy. There was no evidence for CNS immune-mediated lesions on conventional imaging nor for cellular infiltration in the cerebrospinal fluid. Serum analyses revealed the presence of anti-neuronal antibodies directed against anti-contactin-associated protein 2 (anti-Caspr2), a protein associated with voltage-gated potassium neuronal channels. Functional imaging with 2-deoxy-2-[fluorine-18] fluoro- d-glucose integrated with computed tomography (18F-FDG PET-CT) demonstrated diffuse cortical and subcortical hypometabolism. The patient was treated with a combination of immunosuppressive agents (corticosteroids, cyclophosphamide and rituximab) and progressively recovered normal neurocognitive functions. Taken together, these data suggest that CNS-GVHD may manifest as a reversible antibody-mediated functional encephalopathy. This report suggests for the first time the interest of screening for anti-neuronal antibodies and functional imaging with brain 18F-FDG PET-CT in diagnosing this severe complication of allogeneic hematopoietic cell transplantation (alloHSCT).
Asunto(s)
Anticuerpos Anticitoplasma de Neutrófilos/líquido cefalorraquídeo , Encefalopatías/líquido cefalorraquídeo , Encefalopatías/diagnóstico por imagen , Enfermedad Injerto contra Huésped/líquido cefalorraquídeo , Enfermedad Injerto contra Huésped/diagnóstico por imagen , Trasplante de Células Madre Hematopoyéticas/efectos adversos , Encefalopatías/etiología , Enfermedad Crónica , Enfermedad Injerto contra Huésped/etiología , Trasplante de Células Madre Hematopoyéticas/tendencias , Humanos , Masculino , Persona de Mediana Edad , Trasplante Homólogo/efectos adversos , Trasplante Homólogo/tendenciasRESUMEN
Crohn's disease and ulcerative colitis known as inflammatory bowel diseases (IBD) are chronic immuno-inflammatory pathologies of the gastrointestinal tract. These diseases are multifactorial, polygenic and of unknown etiology. Clinical presentation is non-specific and diagnosis is based on clinical, endoscopic, radiological and histological criteria. Novel markers are needed to improve early diagnosis and classification of these pathologies. We performed a study with 120 serum samples collected from patients classified in 4 groups (30 Crohn, 30 ulcerative colitis, 30 inflammatory controls and 30 healthy controls) according to accredited criteria. We compared protein sera profiles obtained with a Surface Enhanced Laser Desorption Ionization-Time of Flight-Mass Spectrometer (SELDI-TOF-MS). Data analysis with univariate process and a multivariate statistical method based on multiple decision trees algorithms allowed us to select some potential biomarkers. Four of them were identified by mass spectrometry and antibody based methods. Multivariate analysis generated models that could classify samples with good sensitivity and specificity (minimum 80%) discriminating groups of patients. This analysis was used as a tool to classify peaks according to differences in level on spectra through the four categories of patients. Four biomarkers showing important diagnostic value were purified, identified (PF4, MRP8, FIBA and Hpalpha2) and two of these: PF4 and Hpalpha2 were detected in sera by classical methods. SELDI-TOF-MS technology and use of the multiple decision trees method led to protein biomarker patterns analysis and allowed the selection of potential individual biomarkers. Their downstream identification may reveal to be helpful for IBD classification and etiology understanding.
Asunto(s)
Biomarcadores/análisis , Enfermedades Inflamatorias del Intestino/diagnóstico , Proteómica/métodos , Transportadoras de Casetes de Unión a ATP/análisis , Humanos , Enfermedades Inflamatorias del Intestino/fisiopatología , Técnicas de Diagnóstico Molecular , Osteopontina/análisis , Factor Plaquetario 4/análisis , Sensibilidad y Especificidad , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodosRESUMEN
BACKGROUND: The aims of the present study were to compare the diagnostic and clinical value of seven commercially available assays for second-generation anti-cyclic citrullinated peptide (CCP2) antibodies, anti-keratin antibodies (AKA) and rheumatoid factor (RF) determination in patients with rheumatoid arthritis (RA), and to check the potential advantages of a third-generation anti-CCP (CCP3) antibodies assay. METHODS: Serum samples from 120 RA patients and from 170 controls were used to determine the sensitivity, the specificity, the positive (PPV) and negative predictive values (NPV) of CCP2 and CCP3 antibodies, AKA and RF assays. The respective performances of these tests were compared using a receiver-operating characteristics (ROC) curves methodology. RESULTS: We found no significant differences in sensitivity and specificity between the tested anti-CCP assays. The CCP3 antibodies assay we evaluated was not significantly more sensitive than those of the second generation. Compared with RF technique, all anti-CCP assays showed better specificity, but lower sensitivity. In contrast, while of equivalent specificity, they proved to be more sensitive than AKA in the discrimination of RA from other rheumatic diseases. CONCLUSIONS: Anti-CCP antibodies determination proved to be a powerful diagnostic tool, especially in RA patients with negative AKA or RF. The investigated CCP3 antibodies assay had no better diagnostic performances than the second-generation assays.