Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Heart J ; 45(28): 2519-2532, 2024 Jul 21.
Artículo en Inglés | MEDLINE | ID: mdl-38820201

RESUMEN

BACKGROUND AND AIMS: Surgical explantation of transcatheter heart valves (THVs) is rapidly increasing, but there are limited data on patients with THV-associated infective endocarditis (IE). This study aims to assess the outcomes of patients undergoing THV explant for IE. METHODS: All patients who underwent THV explant between 2011 and 2022 from 44 sites in the EXPLANT-TAVR registry were identified. Patients with IE as the reason for THV explant were compared to those with other mechanisms of bioprosthetic valve dysfunction (BVD). RESULTS: A total of 372 patients from the EXPLANT-TAVR registry were included. Among them, 184 (49.5%) patients underwent THV explant due to IE and 188 (50.5%) patients due to BVD. At the index transcatheter aortic valve replacement, patients undergoing THV explant for IE were older (74.3 ± 8.6 vs. 71 ± 10.6 years) and had a lower Society of Thoracic Surgeons risk score [2.6% (1.8-5.0) vs. 3.3% (2.1-5.6), P = .029] compared to patients with BVD. Compared to BVD, IE patients had longer intensive care unit and hospital stays (P < .05) and higher stroke rates at 30 days (8.6% vs. 2.9%, P = .032) and 1 year (16.2% vs. 5.2%, P = .010). Adjusted in-hospital, 30-day, and 1-year mortality was 12.1%, 16.1%, and 33.8%, respectively, for the entire cohort, with no significant differences between groups. Although mortality was numerically higher in IE patients 3 years postsurgery (29.6% for BVD vs. 43.9% for IE), Kaplan-Meier analysis showed no significant differences between groups (P = .16). CONCLUSIONS: In the EXPLANT-TAVR registry, patients undergoing THV explant for IE had higher 30-day and 1-year stroke rates and longer intensive care unit and hospital stays. Moreover, patients undergoing THV explant for IE had a higher 3-year mortality rate, which did not reach statistical significance given the relatively small sample size of this unique cohort and the reduced number of events.


Asunto(s)
Endocarditis , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Femenino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Infecciones Relacionadas con Prótesis/epidemiología , Infecciones Relacionadas con Prótesis/mortalidad , Endocarditis/cirugía , Endocarditis/mortalidad , Remoción de Dispositivos , Prótesis Valvulares Cardíacas/efectos adversos , Bioprótesis/efectos adversos , Resultado del Tratamiento , Anciano de 80 o más Años , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología
3.
Psychon Bull Rev ; 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38639836

RESUMEN

Real-world categories often contain exceptions that disobey the perceptual regularities followed by other members. Prominent psychological and neurobiological theories indicate that exception learning relies on the flexible modulation of object representations, but the specific representational shifts key to learning remain poorly understood. Here, we leveraged behavioral and computational approaches to elucidate the representational dynamics during the acquisition of exceptions that violate established regularity knowledge. In our study, participants (n = 42) learned novel categories in which regular and exceptional items were introduced successively; we then fitted a computational model to individuals' categorization performance to infer latent stimulus representations before and after exception learning. We found that in the representational space, exception learning not only drove confusable exceptions to be differentiated from regular items, but also led exceptions within the same category to be integrated based on shared characteristics. These shifts resulted in distinct representational clusters of regular items and exceptions that constituted hierarchically structured category representations, and the distinct clustering of exceptions from regular items was associated with a high ability to generalize and reconcile knowledge of regularities and exceptions. Moreover, by having a second group of participants (n = 42) to judge stimuli's similarity before and after exception learning, we revealed misalignment between representational similarity and behavioral similarity judgments, which further highlights the hierarchical layouts of categories with regularities and exceptions. Altogether, our findings elucidate the representational dynamics giving rise to generalizable category structures that reconcile perceptually inconsistent category members, thereby advancing the understanding of knowledge formation.

4.
Psychon Bull Rev ; 2024 Mar 04.
Artículo en Inglés | MEDLINE | ID: mdl-38438711

RESUMEN

The formation of categories is known to distort perceptual space: representations are pushed away from category boundaries and pulled toward categorical prototypes. This phenomenon has been studied with artificially constructed objects, whose feature dimensions are easily defined and manipulated. How such category-induced perceptual distortions arise for complex, real-world scenes, however, remains largely unknown due to the technical challenge of measuring and controlling scene features. We address this question by generating realistic scene images from a high-dimensional continuous space using generative adversarial networks and using the images as stimuli in a novel learning task. Participants learned to categorize the scene images along arbitrary category boundaries and later reconstructed the same scenes from memory. Systematic biases in reconstruction errors closely tracked each participant's subjective category boundaries. These findings suggest that the perception of global scene properties is warped to align with a newly learned category structure after only a brief learning experience.

5.
bioRxiv ; 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38405893

RESUMEN

Learning systems must constantly decide whether to create new representations or update existing ones. For example, a child learning that a bat is a mammal and not a bird would be best served by creating a new representation, whereas updating may be best when encountering a second similar bat. Characterizing the neural dynamics that underlie these complementary memory operations requires identifying the exact moments when each operation occurs. We address this challenge by interrogating fMRI brain activation with a computational learning model that predicts trial-by-trial when memories are created versus updated. We found distinct neural engagement in anterior hippocampus and ventral striatum for model-predicted memory create and update events during early learning. Notably, the degree of this effect in hippocampus, but not ventral striatum, significantly related to learning outcome. Hippocampus additionally showed distinct patterns of functional coactivation with ventromedial prefrontal cortex and angular gyrus during memory creation and premotor cortex during memory updating. These findings suggest that complementary memory functions, as formalized in computational learning models, underlie the rapid formation of novel conceptual knowledge, with the hippocampus and its interactions with frontoparietal circuits playing a crucial role in successful learning. Significance statement: How do we reconcile new experiences with existing knowledge? Prominent theories suggest that novel information is either captured by creating new memories or leveraged to update existing memories, yet empirical support of how these distinct memory operations unfold during learning is limited. Here, we combine computational modeling of human learning behaviour with functional neuroimaging to identify moments of memory formation and updating and characterize their neural signatures. We find that both hippocampus and ventral striatum are distinctly engaged when memories are created versus updated; however, it is only hippocampus activation that is associated with learning outcomes. Our findings motivate a key theoretical revision that positions hippocampus is a key player in building organized memories from the earliest moments of learning.

6.
Eur J Heart Fail ; 26(2): 460-470, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38297972

RESUMEN

Patients with severe aortic stenosis (AS) may develop heart failure (HF), the presence of which has traditionally been deemed as a final stage in AS progression with poor outcomes. The use of transcatheter aortic valve replacement (TAVR) has become the preferred therapy for most patients with AS and concomitant HF. With its instant afterload reduction, TAVR offers patients with HF significant haemodynamic benefits, with corresponding changes in left ventricular structure and improved mortality and quality of life. The prognostic covariates and optimal timing of TAVR in patients with less than severe AS remain unclear. The purpose of this review is to describe the association between TAVR and outcomes in patients with HF, particularly in the setting of left ventricular systolic dysfunction, acute HF, and right ventricular systolic dysfunction, and to highlight areas for future research.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Calidad de Vida , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/cirugía , Resultado del Tratamiento , Válvula Aórtica/cirugía , Factores de Riesgo , Índice de Severidad de la Enfermedad , Función Ventricular Izquierda
7.
Am J Cardiol ; 220: 67-76, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38582312

RESUMEN

Transcatheter tricuspid valve intervention (TTVI) has recently emerged as a promising alternative to surgery for tricuspid regurgitation (TR). However, a significant proportion of patients fail screening for TTVI, and little is known about their characteristics and natural history. This study sought to investigate causes of screen failure and outcomes of patients declined for TTVI. This was a retrospective single-center study of 32 patients who were ineligible for participation in transcatheter tricuspid valve replacement and tricuspid transcatheter edge-to-edge repair trials. Patients were classified into 2 groups according to the therapy they received: optimized medical therapy (OMT) group or intervention group. The mean age was 82 ± 7.8 years and 68.8% were women. The most common reasons for TTVI exclusion were anatomic/procedural impediment (53.1%), inclusion criteria not met (40.6%), and multivalvular disease (6.3%). Overall, 19 patients (59.4%) did not undergo subsequent tricuspid intervention. The clinical outcomes of these patients who received OMT alone were poor, with a 1-year composite of cardiac death or heart failure readmission of 47.4%. These rates were worse than in patients who subsequently underwent an intervention, albeit not statistically significant (OMT: 47.7% vs 23.1% interventions, p = 0.3), and were significantly more pronounced in the subgroup of patients who were excluded for anatomic/procedural limitations (OMT: 70% vs 14.3% interventions, p = 0.05). In conclusion, patients ineligible for TTVI, particularly, those with anatomic/procedural limitations, and treated medically have poor outcomes. These data underscore the importance of earlier referral and support the need for further transcatheter therapy iterations.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Femenino , Masculino , Estudios Retrospectivos , Insuficiencia de la Válvula Tricúspide/cirugía , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Válvula Tricúspide/cirugía , Válvula Tricúspide/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anciano , Resultado del Tratamiento , Estudios de Seguimiento , Tamizaje Masivo/métodos
8.
Circ Cardiovasc Interv ; 17(4): e013581, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38436084

RESUMEN

BACKGROUND: Transcatheter edge-to-edge mitral valve (MV) repair (TEER) is an effective treatment for patients with primary mitral regurgitation at prohibitive risk for surgical MV repair (MVr). High-volume MVr centers and high-volume TEER centers have better outcomes than low-volume centers, respectively. However, whether MVr volume predicts TEER outcomes remains unknown. We hypothesized that high-volume MV surgical centers would have superior risk-adjusted outcomes for TEER than low-volume centers. METHODS: We combined data from the American College of Cardiology/Society of Thoracic Surgeons Transcatheter Valve Therapy registry and the Society of Thoracic Surgeons adult cardiac surgery database. MVr was defined as leaflet resection or artificial chords with or without annuloplasty and was evaluated as a continuous variable and as predefined categories (<25, 25-49, and ≥50 MV repairs/year). A generalized linear mixed model was used to evaluate risk-adjusted in-hospital/30-day mortality, 30-day heart failure readmission, and TEER success (mitral regurgitation ≤2+ and gradient <5 mm Hg). RESULTS: The study comprised 41 834 patients from 500 sites of which 332 (66.4%) were low, 102 (20.4%) intermediate, and 66 (13.2%) high-volume surgical centers (P<0.001). TEER success was 54.6% and was not statistically significantly different across MV surgical site volumes (P=0.4271). TEER mortality at 30 days was 3.5% with no significant difference across MVr volume on unadjusted (P=0.141) or adjusted (P=0.071) analysis of volume as a continuous variable. One-year mortality was 15.0% and was lower for higher MVr volume centers when adjusted for clinical and demographic variables (P=0.027). Heart failure readmission at 1 year was 9.4% and was statistically significantly lower in high-volume centers on both unadjusted (P=0.017) or adjusted (P=0.015) analysis. CONCLUSIONS: TEER can be safely performed in centers with low volumes of MV repair. However, 1-year mortality and heart failure readmission are superior at centers with higher MVr volume.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia Cardíaca/etiología , Hospitales
9.
Am J Cardiol ; 2024 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-39117008

RESUMEN

Valve-in-Valve (ViV) Transcatheter aortic valve replacement (TAVR) has been associated with favorable outcomes in patients with degenerated stentless bioprosthesis. However, whether the outcomes after ViV TAVR for failed stentless bioprosthesis differ between balloon-expandable valves (BEV) and self-expanding valves (SEV) remains unknown. Therefore, we retrospectively analyzed 59 consecutive patients who underwent ViV TAVR for failed stentless bioprsothesis with BEV (N= 42) versus SEV (N= 17) in a single-healthcare system between 2013 and 2022. Overall, mean age was 70.8 years and 74.6% were males. Mean transcatheter valve size was 26.3 ±2.2 mm for BEV and 26.4 ±4 mm for SEV (p= 0.93). Mean STS score was 6.0 ±3.6 for BEV and 7.5 ±5.5 for SEV (p= 0.22). Compared with patients who received BEV, those who received SEV had higher rates of device malposition (2.4% vs. 23.5%; p< 0.01), post-deployment balloon dilation (11.9% vs. 35.5%; p= 0.04) and need for a second transcatheter device (2.4% vs. 35.5%; p< 0.01). However, both groups showed similar improvement in aortic valve function at 30-day and 1-year follow-up (incidence of 1-year severe patient-prosthesis mismatch in BEV: 17.6% vs. 14.3% in SEV; p= 0.78). One-year and 3-year mortality did not differ between BEV and SEV (11.9% vs. 11.8% and 25% vs. 30%; respectively; Log rank p= 0.9). In conclusion, performing ViV TAVR for failed stentless bioprsothesis is technically challenging, especially when using SEV, but satisfactory positioning is possible in most cases, with excellent hemodynamic and clinical outcomes with both BEV and SEV.

10.
Ann Thorac Surg ; 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38972369

RESUMEN

BACKGROUND: Perioperative blood transfusion is associated with adverse outcomes and higher costs after coronary artery bypass graft (CABG) surgery. We developed risk assessments for patients' probability of perioperative transfusion and the expected transfusion volume to improve clinical management and resource use. METHODS: Among 1,266,545 consecutive (2008-2016) isolated CABG operations in The Society of Thoracic Surgeons Adult Cardiac Surgery Database, 657,821 (51.9%) received perioperative transfusions of red blood cells (RBC), fresh frozen plasma (FFP), cryoprecipitate, and/or platelets. We developed "full" models to predict perioperative transfusion of any blood product, and of RBC, FFP, or platelets. Using least absolute shrinkage and selection operator model selection, we built a rapid risk score based on 5 variables (age, body surface area, sex, preoperative hematocrit, and use of intra-aortic balloon pump). RESULTS: C statistics for the full model were 0.785, 0.815, 0.707, and 0.699 for any blood product, RBC, FFP, and platelets, respectively. C statistics for rapid risk assessments were 0.752, 0.785, 0.670, and 0.661 for any blood product, RBC, FFP, and platelets, respectively. The observed vs expected risk plots showed strong calibration for full models and risk assessment tools; absolute differences between observed and expected risks of transfusion were <10.8% in each percentile of expected risk. Risk assessment-predicted probabilities of transfusion were strongly and nonlinearly associated (P < .0001) with total units transfused. CONCLUSIONS: These robust and well-calibrated risk assessment tools for perioperative transfusion in CABG can inform surgeons regarding patients' risks and the number of RBC, FFP, and platelets units they can expect to need. This can aid in optimizing outcomes and increasing efficient use of blood products.

11.
JACC Cardiovasc Interv ; 17(4): 505-515, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38340102

RESUMEN

BACKGROUND: A single, multitiered valve center designation has been proposed to publicly identify centers with expertise for all valve therapies. The correlation between transcatheter aortic valve replacement (TAVR) and mitral transcatheter edge-to-edge repair (MTEER) procedures is unknown. OBJECTIVES: The authors sought to examine the relationship between site-level volumes and outcomes for TAVR and MTEER. We further explored variability between sites for MTEER outcomes. METHODS: Using the STS/ACC TVT (Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy) national registry, TAVR and MTEER procedures at sites offering both therapies from 2013 to 2022 were examined. Sites were ranked into deciles of adjusted in-hospital and 30-day outcomes separately for TAVR and MTEER and compared. Stepwise, hierarchical multivariable models were constructed for MTEER outcomes, and the median OR was calculated. RESULTS: Between 2013 and 2022, 384,394 TAVRs and 53,274 MTEERs (median annualized volumes: 93.6 and 18.8, respectively) were performed across 453 U.S. sites. Annualized TAVR and MTEER volumes were moderately correlated (r = 0.48; P < 0.001). After adjustment, 14.3% of sites had the same decile rank for TAVR and MTEER 30-day composite outcome, 50.6% were within 2 decile ranks; 35% had more discordant outcomes for the 2 procedures (P = 0.0005). For MTEER procedures, the median OR for the 30-day composite outcome was 1.57 (95% CI: 1.51-1.64), indicating a 57% variability in outcome by site. CONCLUSIONS: There is modest correlation between hospital-level volumes for TAVR and MTEER but low interprocedural correlation of outcomes. For similar patients, site-level variability for mortality/morbidity following MTEER was high. Factors influencing outcomes and "centers of excellence" as a whole may differ for TAVR and MTEER.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estados Unidos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Resultado del Tratamiento , Sistema de Registros , Hospitales , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
12.
Ann Clin Transl Neurol ; 11(2): 263-277, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38155462

RESUMEN

OBJECTIVE: Although acute brain infarcts are common after surgical aortic valve replacement (SAVR), they are often unassociated with clinical stroke symptoms. The relationship between clinically "silent" infarcts and in-hospital delirium remains uncertain; obscured, in part, by how infarcts have been traditionally summarized as global metrics, independent of location or structural consequence. We sought to determine if infarct location and related structural connectivity changes were associated with postoperative delirium after SAVR. METHODS: A secondary analysis of a randomized multicenter SAVR trial of embolic protection devices (NCT02389894) was conducted, excluding participants with clinical stroke or incomplete neuroimaging (N = 298; 39% female, 7% non-White, 74 ± 7 years). Delirium during in-hospital recovery was serially screened using the Confusion Assessment Method. Parcellation and tractography atlas-based neuroimaging methods were used to determine infarct locations and cortical connectivity effects. Mixed-effect, zero-inflated gaussian modeling analyses, accounting for brain region-specific infarct characteristics, were conducted to examine for differences within and between groups by delirium status and perioperative neuroprotection device strategy. RESULTS: 23.5% participants experienced postoperative delirium. Delirium was associated with significantly increased lesion volumes in the right cerebellum and temporal lobe white matter, while diffusion weighted imaging infarct-related structural disconnection (DWI-ISD) was observed in frontal and temporal lobe regions (p-FDR < 0.05). Fewer brain regions demonstrated DWI-ISD loss in the suction-based neuroprotection device group, relative to filtration-based device or standard aortic cannula. INTERPRETATION: Structural disconnection from acute infarcts was greater in patients who experienced postoperative delirium, suggesting that the impact from covert perioperative infarcts may not be as clinically "silent" as commonly assumed.


Asunto(s)
Delirio , Delirio del Despertar , Implantación de Prótesis de Válvulas Cardíacas , Accidente Cerebrovascular , Humanos , Femenino , Masculino , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo , Delirio/etiología , Infarto/cirugía
13.
JACC Adv ; 3(3): 100853, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938841

RESUMEN

Background: Low stroke volume index <35 ml/m2 despite preserved ejection fraction (paradoxical low flow [PLF]) is associated with adverse outcomes in patients with aortic stenosis undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR). However, whether the risk associated with PLF is similar in both sexes is unknown. Objectives: The purpose of this study was to analyze the risk associated with PLF in severe aortic stenosis for men and women randomized to TAVR or SAVR. Methods: Patients with ejection fraction ≥50% from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were stratified by sex and treatment arm. The impact of PLF on the 2-year occurrence of the composite of death or heart failure hospitalization (primary endpoint) and of all-cause mortality alone (secondary endpoint) was analyzed. Analysis of variance was used to assess baseline differences between groups. Multivariate Cox regression analysis was used to identify predictors of the endpoint. Results: Out of 2,242 patients, PLF was present in 390 men and 239 women (30% vs 26%, P = 0.06). PLF was associated with a higher rate of NYHA functional class III to IV dyspnea (60% vs 54%, P < 0.001) and a higher prevalence of atrial fibrillation (39% vs 24%, P < 0.001). PLF was a significant predictor of the primary endpoint among women undergoing SAVR in multivariate analysis (adjusted HR: 2.25 [95% CI: 1.14-4.43], P = 0.02) but was not associated with a worse outcome in any of the other groups (all P > 0.05). Conclusions: In women with PLF, TAVR may improve outcomes compared to SAVR. PLF appears to have less impact on outcomes in men.

14.
Am J Cardiol ; 223: 7-14, 2024 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-38788821

RESUMEN

The frequency and effectiveness of repeat mitral valve interventions (RMVI) after transcatheter edge-to-edge repair (TEER) for secondary mitral regurgitation (MR) are unknown. We aimed to examine the rate of and outcomes after RMVI after TEER in the Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) trial. Only 3.9% of COAPT trial patients required a repeat mitral valve intervention during 4-year follow-up which was successful in 90% of cases but was associated with an increased rate of heart failure (HF) hospitalizations (HFH). The COAPT trial randomized HF patients with severe secondary MR to TEER with the MitraClip device plus guideline-directed medical therapy (GDMT) versus GDMT alone. We evaluated the characteristics and outcomes of patients who had an RMVI during 4-year follow-up. A MitraClip implant was attempted in 293 patients randomized to TEER+GDMT, 10 of whom underwent an RMVI procedure (9 repeat TEER and 1 surgical mitral valve replacement) after 4 years of follow-up (cumulative incidence 3.90%, 95% confidence interval [CI] 2.08 to 7.08; median 182 days after the initial procedure). Patients with RMVI had larger mitral annular diameters, fewer clips implanted, and were more likely to have ≥3+MR at discharge compared with those without RMVI. Reasons for RMVI included failed index procedure because of difficult transseptal puncture (n = 2) or tamponade (n = 1); residual or recurrent severe MR after an initially successful procedure (n = 5); partial clip detachment (n = 1); and site-assessed mitral stenosis (n = 1). RMVI was successful in 8/10 (80%) patients. Patients who underwent RMVI had higher 4-year rates of HFH but similar mortality compared with those without RMVI. The annualized incidence rates of all HFH in patients who underwent RMVI were 234 events per 100 person-years (95% CI 139 to 395) pre-RMVI and 46 per 100 person-years (95% CI 25 to 86) post-RMVI as compared with 32 events per 100 patient-years (95% CI 28 to 36) in patients without RMVI. The rate ratio of HFH was reduced after RMVI in patients who underwent RMVI (0.20, 95% CI 0.09 to 0.45). In conclusion, the cumulative incidence of RMVI after 4 years was 3.9% in patients who underwent TEER for severe secondary MR in the COAPT trial. Patients who underwent RMVI were at increased risk of HFH which was reduced after the RMVI procedure. Clinical Trial Registration: Clinical Trial Name: Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation (The COAPT Trial) (COAPT) ClinicalTrial.gov Identifier: NCT01626079 URL:https://clinicaltrials.gov/ct2/show/NCT01626079.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Masculino , Femenino , Anciano , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Estudios de Seguimiento , Resultado del Tratamiento , Anciano de 80 o más Años , Reoperación , Insuficiencia Cardíaca/terapia
15.
Am J Cardiol ; 220: 102-110, 2024 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-38432334

RESUMEN

Proximal radial artery (PRA) access for cardiac catheterization is safe but can jeopardize subsequent use of the artery because of occlusion. Distal radial artery (DRA) access in the anatomical snuffbox preserves the RA but safety and potential detrimental effects on hand function are unknown. We aimed to assess hand function and complications after DRA and PRA. In this single-center trial, 300 patients were randomly allocated 1:1 to cardiac catheterization through DRA or PRA. The primary end point of change in hand function from baseline to 1 year was a composite of the Quick Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire, hand grip test, and thumb-forefinger pinch test. The secondary end points included access feasibility and complications. Of 216 patients with 1-year completed follow-up, 112 were randomly allocated to DRA and 104 to PRA, with balanced demographics and procedural characteristics. Both groups had similar access site bleeding rates (DRA 0% vs PRA 1.4%, p = 0.25). Radial artery occlusion occurred in 1 PRA patient versus 2 in DRA. There was no significant difference in change of hand function, median (interquartile range) hand grip (DRA 0.7 [-3 to 4.5] vs PRA 1.3 [-2 to 4.3] kg, p = 0.57), pinch grip (DRA -0.1 [-1.1 to 1] vs PRA -0.3 [-1 to 0.7] kg, p = 0.66), and Quick DASH (DRA 0 [-6.6 to 2.3] vs PRA 0 [-4.6 to 2.9] points, p = 0.58). The composite of hand function was comparable between PRA and DRA. In conclusion, DRA is a safe strategy for cardiac catheterization, with a low complication rate. Compared with PRA, there is no increased risk of hand dysfunction or radial artery occlusion at 1 year.


Asunto(s)
Cateterismo Cardíaco , Arteria Radial , Humanos , Masculino , Femenino , Cateterismo Cardíaco/métodos , Persona de Mediana Edad , Anciano , Fuerza de la Mano/fisiología , Estudios de Seguimiento , Factores de Tiempo
16.
Proc (Bayl Univ Med Cent) ; 37(2): 205-209, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343487

RESUMEN

Background: Conduction abnormality requiring the implantation of a permanent pacemaker (PPM) is a well-known and clinically important complication of transcatheter aortic valve replacement (TAVR). However, PPM implantation may result in lead-associated tricuspid valve regurgitation (TR). This study sought to determine the incidence and progression of TR following PPM implantation after TAVR. Methods: This was a retrospective review of all echocardiograms of patients who underwent PPM following TAVR at the Baylor Scott & White hospitals from 2012 to 2021. The primary endpoint was TR progression at 30 days and 1 year. A subanalysis comparing the change in TR progression between small and large TAVR devices was also conducted. Secondary outcomes included all-cause death at 30 days and 1 year. Results: Out of the 2744 patients who underwent TAVR between April 2012 and August 2021, 177 patients (6.5%) subsequently received a new PPM. There was a statistically significant progression of TR at 1-year follow-up (McNemar's P value = 0.02). TR progression rates were comparable between the small and large valve groups at 1-year follow-up (4% vs 11%, P = 0.09, respectively). Conclusion: In this single healthcare system study, we demonstrated a significant progression of TR in patients with PPM post TAVR at 1 year.

17.
Proc (Bayl Univ Med Cent) ; 37(2): 218-226, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38343489

RESUMEN

Background: In March 2022, a COVID-19 outbreak disrupted the global supply of iodine contrast media (ICM). Healthcare systems implemented contrast-saving strategies to maintain their remaining ICM supplies. This study sought to determine the impact of contrast shortage on the incidence of contrast-associated acute kidney injury (CA-AKI). Methods: This was a retrospective study of 265 patients undergoing 278 percutaneous coronary interventions (PCI) during 4-month periods prior to (9/1/2021 to 12/31/2021) and during (5/1/2022 to 8/31/2022) contrast shortage at a single center. The primary endpoint was the incidence of CA-AKI between study periods. Results: A total of 148 and 130 PCIs were performed before and during contrast shortage, respectively. The incidence of CA-AKI significantly decreased from 11.5% to 4.6% during contrast shortage (P = 0.04). During the shortage, average contrast volume per PCI was significantly lower (123 ± 62 mL vs 88 ± 46 mL, P < 0.001), while coronary imaging was significantly higher (34.3% vs 50%, P = 0.009) compared to preshortage. All-cause mortality at discharge was comparable between study periods (2.8% vs 3.3%, respectively; P = 0.90). Conclusion: The scarcity of ICM for PCI procedures in this single-center experience was associated with a significant increase in the utilization of intravascular imaging and a significant reduction in CA-AKI.

18.
Proc (Bayl Univ Med Cent) ; 37(4): 569-575, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38910820

RESUMEN

Background: Among patients with bicuspid aortic valves (BAV) who are potential candidates for valve-sparing root replacement (VSRR), the long-term durability of this technique is not well understood. This study aimed to compare the clinical and echocardiographic outcomes of VSRR in those with BAV and tricuspid aortic valve (TAV) morphology. Methods: This was a retrospective analysis of patients who underwent VSRR between 2007 and 2021 at a single center. Kaplan-Meier and log-rank analysis were used to estimate and compare freedom from mortality, progression to >2+ aortic insufficiency (AI), and reoperation between groups (BAV vs TAV). Preoperative and postoperative echocardiographic data were collected and assessed for temporal changes in mixed-effect models. Results: A total of 185 patients (BAV, n = 52, 28.1%; TAV, n = 133, 71.9%) underwent VSRR. At baseline, BAV patients were younger (42.4 ± 11.6 vs 52.3 ± 12.6 years; P < 0.01) and had more severe AI (47.9% vs 27.0%; P = 0.02). Average cardiopulmonary bypass and cross-clamp times were similar. There were no differences in rates of postoperative complications, intensive care unit or hospital days, or 30-day readmission. TAV patients' 1-, 5-, and 8-year survival rates were 99.2% [95% CI 97.8-100], 96.7% [93.5-99.9%], and 92.2% [85.6-99.3%], respectively. Overall, there were no differences between groups regarding freedom from mortality (P = 0.18), reoperation (P = 0.51), or recurrent >2+ AI (P = 0.97). . Conclusions: VSRR can be safely performed on patients with BAV and TAV morphology, yielding similar midterm freedom from mortality, recurrent >2+ AI, and reoperation. This technique should be considered in carefully selected patients with aortic root pathology and BAV anatomy when performed at experienced centers.

19.
JAMA Cardiol ; 9(7): 631-639, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38776106

RESUMEN

Importance: The use of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has been rapidly expanding as an alternative treatment to redo surgical aortic valve replacement (SAVR) for failed bioprosthetic valves despite limited long-term data. Objective: To assess mortality and morbidity in patients undergoing intervention for failed bioprosthetic SAVR. Design, Setting, and Participants: This was a retrospective population-based cohort analysis conducted between January 1, 2015, and December 31, 2020, with a median (IQR) follow-up time of 2.3 (1.1-4.0) years. A total of 1771 patients with a history of bioprosthetic SAVR who underwent ViV-TAVR or redo SAVR in California, New York, and New Jersey were included. Data were obtained from the California Department of Health Care Access and Information, the New York Statewide Planning and Research Cooperative System, and the New Jersey Discharge Data Collection System. Exclusion criteria included undergoing TAVR or redo SAVR within 5 years from initial SAVR, as well as infective endocarditis, concomitant surgical procedures, and out-of-state residency. Propensity matching yielded 375 patient pairs. Data were analyzed from January to December 2023. Interventions: ViV-TAVR vs redo SAVR. Main Outcomes and Measurements: The primary outcome was all-cause mortality. Secondary outcomes were stroke, heart failure hospitalization, reoperation, major bleeding, acute kidney failure, new pacemaker insertion, and infective endocarditis. Results: From 2015 through 2020, the proportion of patients undergoing ViV-TAVR vs redo SAVR increased from 159 of 451 (35.3%) to 498 or 797 (62.5%). Of 1771 participants, 653 (36.9%) were female, and the mean (SD) age was 74.4 (11.3) years. Periprocedural mortality and stroke rates were similar between propensity-matched groups. The ViV-TAVR group had lower periprocedural rates of major bleeding (2.4% vs 5.1%; P = .05), acute kidney failure (1.3% vs 7.2%; P < .001), and new pacemaker implantations (3.5% vs 10.9%; P < .001). The 5-year all-cause mortality rate was 23.4% (95% CI, 15.7-34.1) in the ViV-TAVR group and 13.3% (95% CI, 9.2-18.9) in the redo SAVR group. In a landmark analysis, no difference in mortality was observed up to 2 years (hazard ratio, 1.03; 95% CI, 0.59-1.78), but after 2 years, ViV-TAVR was associated with higher mortality (hazard ratio, 2.97; 95% CI, 1.18-7.47) as well as with a higher incidence of heart failure hospitalization (hazard ratio, 3.81; 95% CI, 1.57-9.22). There were no differences in 5-year incidence of stroke, reoperation, major bleeding, or infective endocarditis. Conclusions and Relevance: Compared with redo SAVR, ViV-TAVR was associated with a lower incidence of periprocedural complications and a similar incidence of all-cause mortality through 2 years' follow-up. However, ViV-TAVR was associated with higher rates of late mortality and heart failure hospitalization. These findings may be influenced by residual confounding and require adjudication in a randomized clinical trial.


Asunto(s)
Bioprótesis , Reoperación , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Masculino , Anciano , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estudios Retrospectivos , Reoperación/estadística & datos numéricos , Anciano de 80 o más Años , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
20.
JACC Clin Electrophysiol ; 10(5): 930-940, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38661602

RESUMEN

BACKGROUND: Postoperative atrial fibrillation (POAF) is associated with increased morbidity and mortality. Epicardial injection of botulinum toxin may suppress POAF. OBJECTIVES: This study sought to assess the safety and efficacy of AGN-151607 for the prevention of POAF after cardiac surgery. METHODS: This phase 2, randomized, placebo-controlled trial assessed the safety and efficacy of AGN-151607, 125 U and 250 U vs placebo (1:1:1), for the prevention of POAF after cardiac surgery. Randomization was stratified by age (<65, ≥65 years) and type of surgery (nonvalvular/valve surgery). The primary endpoint was the occurrence of continuous AF ≥30 seconds. RESULTS: Among 312 modified intention-to-treat participants (placebo, n = 102; 125 U, n = 104; and 250 U, n = 106), the mean age was 66.9 ± 6.8 years; 17% were female; and 64% had coronary artery bypass graft (CABG) only, 12% had CABG + valve, and 24% had valve surgery. The primary endpoint occurred in 46.1% of the placebo group, 36.5% of the 125-U group (relative risk [RR] vs placebo: 0.80; 95% CI: 0.58-1.10; P = 0.16), and 47.2% of the 250-U group (RR vs placebo: 1.04; 95% CI: 0.79-1.37; P = 0.78). The primary endpoint was reduced in the 125-U group in those ≥65 years of age (RR: 0.64; 95% CI: 0.43-0.94; P = 0.02) with a greater reduction in CABG-only participants ≥65 years of age (RR: 0.49; 95% CI: 0.27-0.87; P = 0.01). Rehospitalization and rates of adverse events were similar across the 3 groups. CONCLUSIONS: There were no significant differences in the rate of POAF with either dose compared with placebo; however, there was a lower rate of POAF in participants ≥65 years undergoing CABG only and receiving 125 U of AGN-151607. These hypothesis-generating findings require investigation in a larger, adequately powered randomized clinical trial. (Botulinum Toxin Type A [AGN-151607] for the Prevention of Post-operative Atrial Fibrillation in Adult Participants Undergoing Open-chest Cardiac Surgery [NOVA]; NCT03779841); A Phase 2, Multi-Center, Randomized, Double-Blind, Placebo-Controlled, Dose Ranging Study to Evaluate the Efficacy and Safety of Botulinum Toxin Type A [AGN 151607] Injections into the Epicardial Fat Pads to Prevent Post-Operative Atrial Fibrillation in Patients Undergoing Open-Chest Cardiac Surgery; 2017-004399-68).


Asunto(s)
Fibrilación Atrial , Toxinas Botulínicas Tipo A , Complicaciones Posoperatorias , Humanos , Fibrilación Atrial/prevención & control , Femenino , Masculino , Anciano , Toxinas Botulínicas Tipo A/uso terapéutico , Toxinas Botulínicas Tipo A/administración & dosificación , Persona de Mediana Edad , Complicaciones Posoperatorias/prevención & control , Método Doble Ciego , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Resultado del Tratamiento , Puente de Arteria Coronaria/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA