Sensors (Basel) ; 20(10)2020 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-32455887

RESUMEN

A dual-gas sensor based on the combination of a quartz-enhanced photoacoustic spectroscopy (QEPAS) sensor and an electronic hygrometer was realized for the simultaneous detection of methane (CH4) and water vapor (H2O) in air. The QEPAS sensor employed an interband cascade laser operating at 3.34 µm capable of targeting a CH4 absorption line at 2988.8 cm-1 and a water line at 2988.6 cm-1. Water vapor was measured with both the electronic hygrometer and the QEPAS sensor for comparison. The measurement accuracy provided by the hygrometer enabled the adjustment of methane QEPAS signal with respect to the water vapor concentration to retrieve the actual CH4 concentration. The sensor was tested by performing prolonged measurements of CH4 and H2O over 60 h to demonstrate the effectiveness of this approach for environmental monitoring applications.

2.
Anal Chem ; 91(20): 12866-12873, 2019 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-31500409

RESUMEN

The development of a dual-gas quartz-enhanced photoacoustic (QEPAS) sensor capable of simultaneous detection of water vapor and alternatively methane or nitrous oxide is reported. A diode laser and a quantum cascade laser (QCL) excited independently and simultaneously both the fundamental and the first overtone flexural mode of the quartz tuning fork (QTF), respectively. The diode laser targeted a water absorption line located at 7181.16 cm-1 (1.392 µm), while the QCL emission wavelength is centered at 7.71 µm and was tuned to target two strong absorption lines of methane and nitrous oxide, located at 1297.47 and 1297.05 cm-1, respectively. Two sets of microresonator tubes were positioned, respectively, at the antinode points of the fundamental and the first overtone flexural modes of the QTF to enhance the QEPAS signal-to-noise ratio. Detection limits of 18 ppb for methane, 5 ppb for nitrous oxide and 20 ppm for water vapor have been achieved at a lock-in integration time of 100 ms.

3.
Opt Express ; 27(2): 1401-1415, 2019 Jan 21.
Artículo en Inglés | MEDLINE | ID: mdl-30696206

RESUMEN

We report on the design, realization, and performance of novel quartz tuning forks (QTFs) optimized for quartz-enhanced photoacoustic spectroscopy (QEPAS). Starting from a QTF geometry designed to provide a fundamental flexural in-plane vibrational mode resonance frequency of ~16 kHz, with a quality factor of 15,000 at atmospheric pressure, two novel geometries have been realized: a QTF with T-shaped prongs and a QTF with prongs having rectangular grooves carved on both surface sides. The QTF with grooves showed the lowest electrical resistance, while the T-shaped prongs QTF provided the best photoacoustic response in terms of signal-to-noise ratio (SNR). When acoustically coupled with a pair of micro-resonator tubes, the T-shaped QTF provides a SNR enhancement of a factor of 60 with respect to the bare QTF, which represents a record value for mid-infrared QEPAS sensing.

4.
Opt Express ; 27(4): 4271-4280, 2019 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-30876044

RESUMEN

The design and realization of two highly sensitive and easily interchangeable spectrophones based on custom quartz tuning forks, with a rectangular (S1) or T-shaped (S2) prongs geometry, is reported. The two spectrophones have been implemented in a QEPAS sensor for ethylene detection, employing a DFB-QCL emitting at 10.337 µm with an optical power of 74.2 mW. A comparison between their performances showed a signal-to-noise ratio 3.4 times higher when implementing the S2 spectrophone. For the S2-based sensor, a linear dependence of the QEPAS signal on ethylene concentration was demonstrated in the 5 ppm -100 ppm range. For a 10 s lock-in integration time, an ethylene minimum detection limit of 10 ppb was calculated.

5.
Opt Lett ; 43(8): 1854-1857, 2018 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-29652382

RESUMEN

The design, realization, and performance analysis of an octupole electrode pattern configuration intended for the optimization of the charge collection efficiency in quartz tuning forks (QTFs) vibrating at the first overtone in-plane flexural mode is reported. Two QTFs having the same geometry, but differing in the electrode pattern deposited on the QTF prongs, have been realized in order to study the influence of the electrode pattern on the resonance quality factor and electrical resistance. A standard quadrupole pattern (optimized for the fundamental mode) and an octupole electrode layout have been implemented. Although both QTFs show the same resonance quality factor for the first overtone, the octupole pattern provides a reduction of the QTF electrical resistance by more than four times. The sensing performance of the two QTFs has been compared by employing them in a mid-IR quartz-enhanced photoacoustic sensor (QEPAS) system targeting a water absorption line. When operating at the first overtone mode, the QTF with an octupole electrode pattern provides a QEPAS signal more than two times higher with respect to the QTF employing the standard quadrupole configuration.

6.
Photoacoustics ; 25: 100318, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34888139

RESUMEN

We report on the realization, calibration, and test outdoor of a 19-inches rack 3-units sized Quartz Enhanced Photoacoustic Spectroscopy (QEPAS) trace gas sensor designed for real-time carbon monoxide monitoring in ambient air. Since CO acts as a slow energy relaxer when excited in the mid-infrared spectral region, its QEPAS signal is affected by the presence of relaxation promoters, such as water vapor, or quenchers like molecular oxygen. We analyzed in detail all the CO relaxation processes with typical collisional partners in an ambient air matrix and used this information to evaluate oxygen and humidity-related effects, allowing the real CO concentration to be retrieved. The sensor was tested outdoor in a trafficked urban area for several hours providing results comparable with the daily averages reported by the local air inspection agency, with spikes in CO concentration correlated to the passages of heavy-duty vehicles.

7.
Artículo en Inglés | MEDLINE | ID: mdl-29994396

RESUMEN

Quartz tuning forks (QTFs) are piezo-transducers that have been implemented for numerous applications, such as chemical gas sensing, atomic force microscopy, rheology, and industrial process control. The most important parameter for QTFs' sensing application is the resonance quality factor (Q-factor). An experimental investigation and theoretical analysis of the influence of QTFs' geometries on the Q-factor of the flexural fundamental and first overtone resonance modes are reported. The resonance frequencies and related Q-factors for five different QTFs have been measured. The QTF response was recorded at different air pressures to investigate the influence of the surrounding medium on the Q-factor. A data analysis demonstrated that air viscous damping is the dominant energy dissipation mechanism for both flexural modes. Thermoelastic and support losses are additional contributions that depend on the QTF geometry. A study of the QTF damping mechanism dependence upon the prong geometry is also provided.