Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Thorax ; 74(7): 659-666, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-30674586

RESUMEN

RATIONALE: There is a need to develop imaging protocols which assess neutrophilic inflammation in the lung. AIM: To quantify whole lung neutrophil accumulation in (1) healthy volunteers (HV) following inhaled lipopolysaccharide (LPS) or saline and (2) patients with COPD using radiolabelled autologous neutrophils and single-photon emission computed tomography/CT (SPECT/CT). METHODS: 20 patients with COPD (Global initiative for chronic obstructive lung disease (GOLD) stages 2-3) and 18 HVs were studied. HVs received inhaled saline (n=6) or LPS (50 µg, n=12) prior to the injection of radiolabelled cells. Neutrophils were isolated using dextran sedimentation and Percoll plasma gradients and labelled with 99mTechnetium (Tc)-hexamethylpropyleneamine oxime. SPECT was performed over the thorax/upper abdomen at 45 min, 2 hours, 4 hours and 6 hours. Circulating biomarkers were measured prechallenge and post challenge. Blood neutrophil clearance in the lung was determined using Patlak-Rutland graphical analysis. RESULTS: There was increased accumulation of 99mTc-neutrophils in the lungs of patients with COPD and LPS-challenged subjects compared with saline-challenged subjects (saline: 0.0006±0.0003 mL/min/mL lung blood distribution volume [mean ±1 SD]; COPD: 0.0022±0.0010 mL/min/mL [p<0.001]; LPS: 0.0025±0.0008 mL/min/mL [p<0.001]). The accumulation of labelled neutrophils in 10 patients with COPD who underwent repeat radiolabelling/imaging 7-10 days later was highly reproducible (0.0022±0.0010 mL/min/mL vs 0.0023±0.0009 mL/min/mL). Baseline interleukin (IL)-6 levels in patients with COPD were elevated compared with HVs (1.5±1.06 pg/mL [mean ±1 SD] vs 0.4±0.24 pg/mL). LPS challenge increased the circulating IL-6 levels (7.5±2.72 pg/mL) 9 hours post challenge. CONCLUSIONS: This study shows the ability to quantify 'whole lung' neutrophil accumulation in HVs following LPS inhalation and in subjects with COPD using autologous radiolabelled neutrophils and SPECT/CT imaging. Moreover, the reproducibility observed supports the feasibility of using this approach to determine the efficacy of therapeutic agents aimed at altering neutrophil migration to the lungs.


Asunto(s)
Pulmón/diagnóstico por imagen , Neutrófilos/fisiología , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Anciano , Biomarcadores/sangre , Femenino , Humanos , Interleucina-6/sangre , Lipopolisacáridos , Masculino , Persona de Mediana Edad , Infiltración Neutrófila/efectos de los fármacos , Infiltración Neutrófila/fisiología , Enfermedad Pulmonar Obstructiva Crónica/patología , Reproducibilidad de los Resultados , Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único/métodos , Tecnecio
2.
Artículo en Inglés | MEDLINE | ID: mdl-29226626

RESUMEN

GSK2982772 is a highly selective inhibitor of receptor-interacting protein kinase 1 (RIPK1) being developed to treat chronic inflammatory diseases. This first-in-human study evaluated safety, tolerability, pharmacokinetics (PK), and exploratory pharmacodynamics (PD) of GSK2982772 administered orally to healthy male volunteers. This was a Phase I, randomized, placebo-controlled, double-blind study. In Part A, subjects received single ascending doses of GSK2982772 (0.1-120 mg) or placebo in a crossover design during each of 4 treatment periods. In Part B, subjects received repeat doses of GSK2982772 (20 mg once daily [QD] to up to 120 mg twice daily [BID]) or placebo for 14 days. Part C was an open-label relative bioavailability study comparing 20-mg tablets vs capsules. Safety, tolerability, pharmacokinetics (PK), RIPK1 target engagement (TE), and pharmacodynamics (PD) were assessed. The most common adverse events (AEs) were contact dermatitis and headache. Most AEs were mild in intensity, and there were no deaths or serious AEs. The PK of GSK2982772 was approximately linear over the dose range studied (up to 120 mg BID). There was no evidence of drug accumulation upon repeat dosing. Greater than 90% RIPK1 TE was achieved over a 24-hour period for the 60-mg and 120-mg BID dosing regimens. Single and repeat doses of GSK2982772 were safe and well tolerated. PK profiles showed dose linearity. The high levels of RIPK1 TE support progression into Phase II clinical trials for further clinical development.


Asunto(s)
Inhibidores de Proteínas Quinasas/administración & dosificación , Proteína Serina-Treonina Quinasas de Interacción con Receptores/antagonistas & inhibidores , Bibliotecas de Moléculas Pequeñas/administración & dosificación , Adulto , Área Bajo la Curva , Estudios Cruzados , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Esquema de Medicación , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Inhibidores de Proteínas Quinasas/farmacocinética , Bibliotecas de Moléculas Pequeñas/farmacocinética , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA