Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Eur Radiol ; 27(8): 3452-3459, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27999984

RESUMEN

OBJECTIVES: To prospectively compare T1-weighted fat-suppressed spin-echo magnetic resonance (MR) sequences after gadolinium application (T1wGdFS) to STIR sequences in patients with acute and chronic foot pain. METHODS: In 51 patients referred for MRI of the foot and ankle, additional transverse and sagittal T1wGdFS sequences were obtained. Two sets of MR images (standard protocol with STIR or T1wGdFS) were analysed. Diagnosis, diagnostic confidence, and localization of the abnormality were noted. Standard of reference was established by an expert panel of two experienced MSK radiologists and one experienced foot surgeon based on MR images, clinical charts and surgical reports. Patients reported prospectively localization of pain. Descriptive statistics, McNemar test and Kappa test were used. RESULTS: Diagnostic accuracy with STIR protocol was 80% for reader 1, 67% for reader 2, with contrast-protocol 84%, both readers. Significance was found for reader 2. Diagnostic confidence for reader 1 was 1.7 with STIR, 1.3 with contrast-protocol; reader 2: 2.1/1.7. Significance was found for reader 1. Pain location correlated with STIR sequences in 64% and 52%, with gadolinium sequences in 70% and 71%. CONCLUSIONS: T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance sequences improve diagnostic accuracy, diagnostic confidence and correlation of MR abnormalities with pain location in MRI of the foot and ankle. However, the additional value is small. KEY POINTS: • Additional value of contrast-enhanced MR over standard MR with STIR sequences exists. • There is slightly more added value for soft tissue than for bony lesions. • This added value is limited. • Therefore, application of contrast material cannot be generally recommended.


Asunto(s)
Dolor Agudo/diagnóstico por imagen , Dolor Crónico/diagnóstico por imagen , Pie/diagnóstico por imagen , Adulto , Anciano , Tobillo/diagnóstico por imagen , Articulación del Tobillo/diagnóstico por imagen , Enfermedades Óseas/diagnóstico por imagen , Medios de Contraste , Femenino , Articulaciones del Pie/diagnóstico por imagen , Gadolinio , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tendones/diagnóstico por imagen , Adulto Joven
2.
AJR Am J Roentgenol ; 202(1): 160-9, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24370140

RESUMEN

OBJECTIVE: The objective of our study was to prospectively compare the diagnostic performance of MR arthrography and conventional MRI with surgical correlation in the same patient for detecting labrum and articular cartilage defects. SUBJECTS AND METHODS: Twenty-eight patients (mean age, 31.8 years) underwent MR arthrography, conventional MRI, and subsequent hip surgery, which served as the reference standard. Labrum and cartilage defects were evaluated at MRI by two independent readers. A McNemar test and kappa statistics were used for statistical analysis. RESULTS: At surgery, 31 labral tears were identified. MR arthrography had an advantage over conventional MRI for detecting labral tears at the anterosuperior quadrant (sensitivity of MR arthrography, 81% and 69% for readers 1 and 2, respectively; sensitivity of conventional MRI, 50% for both readers); this difference in performance between MR arthrography and conventional MRI was statistically significant for reader 1 (p = 0.02) but not for reader 2 (p = 0.2). Interobserver agreement for labral tears was higher for MR arthrography (κ = 0.81) than for conventional MRI (κ = 0.63). Surgery showed 31 acetabular cartilage defects and nine femoral cartilage defects. MR arthrography had an advantage over conventional MRI for detecting acetabular cartilage defects (sensitivity of MR arthrography, 71% and 92% for readers 1 and 2, respectively; sensitivity of conventional MRI, 58% and 83%), whereas there was no advantage to using MR arthrography for detecting femoral cartilage defects with statistically significant difference for the acetabular cartilage or femoral cartilage. Interobserver agreement was slightly higher for MR arthrography (κ = 0.50) than for conventional MRI (κ = 0.40) for assessing the acetabular cartilage and was almost identical for the femoral cartilage (κ = 0.62 and 0.63, respectively). CONCLUSION: MR arthrography was superior to conventional MRI for detecting labral tears and acetabular cartilage defects and showed a higher interobserver agreement. For femoral cartilage lesions, both modalities yielded comparable results.


Asunto(s)
Cartílago Articular/patología , Medios de Contraste/administración & dosificación , Pinzamiento Femoroacetabular/diagnóstico , Pinzamiento Femoroacetabular/cirugía , Articulación de la Cadera/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Artroscopía , Cartílago Articular/cirugía , Femenino , Articulación de la Cadera/cirugía , Humanos , Interpretación de Imagen Asistida por Computador , Inyecciones Intraarticulares , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
3.
J Comput Assist Tomogr ; 38(3): 340-3, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-24681856

RESUMEN

UNLABELLED: Traumatic tendon tear of the rotator cuff occurs frequently and leads to fatty muscle infiltration. With regard to the outcome, fatty infiltration of the rotator cuff muscles constitutes a major negative predictive factor after rotator cuff surgery. In 1989, Goutallier et al established his classification system for assessment of fatty infiltration of the rotator cuff muscles. He used computed tomographic (CT) images in the axial plane. Today, the assessment of rotator cuff muscles on axial CT images has been widely replaced by assessment on parasagittal acquired magnetic resonance images. This change raised 2 important questions. First, there is a controversy whether the Goutallier classification can simply be adopted for magnetic resonance imaging. The second question is whether the muscle assessment in the axial plane is interchangeable with that in the parasagittal plane. We hypothesize that the assessment of fatty muscle infiltration is the same on reformatted parasagittal CT images as on axial CT images METHODS: Three independent readers, 2 radiologists and one shoulder surgeon, rated fatty changes of the supraspinatus muscle on CT scans of 91 shoulders. Goutallier grades were assessed on axial and reformatted parasagittal CT images in 2 separate reading sessions. The paired t test was used to find differences between grading results on axial and reformatted parasagittal images. The Pearson correlation coefficient and weighted kappa statistics were used to quantify linear correlation, intrareader, and interreader agreement. RESULTS: Mean (SD) Goutallier grading among all readers was 0.80 (1.16) (range, 0-4) on axial images and 0.89 (1.05) (range, 004) on parasagittal reconstructions. We detected a trend toward a slightly higher Goutallier grading on parasagittal reconstructions; however, this result was not significant (P = 0.07). The Pearson correlation coefficient was 0.702 (P < 0.001). Weighted kappa statistics indicated a moderately good to good intrareader (range of weighted kappa, 0.53-0.62) and interreader (weighted kappa, axial images, 0.55; reformatted parasagittal images, 0.65) agreement. CONCLUSION: Grading of fatty infiltration of the supraspinatus muscle on parasagittal CT images is comparable with the standard Goutallier grading on axial images and is characterized by a moderately good to good intrareader and interreader agreement. Assessment of parasagittal images is characterized by a slightly higher interreader agreement and may therefore be the preferable modality.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Posicionamiento del Paciente/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Lesiones del Manguito de los Rotadores , Manguito de los Rotadores/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Músculos Superficiales de la Espalda/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Estadística como Asunto , Adulto Joven
4.
Eur Radiol ; 23(9): 2594-601, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23579419

RESUMEN

OBJECTIVE: To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. METHODS: Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0°-10° valgus); (2) abnormal valgus (>10°); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. RESULTS: The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11° valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12° valgus. CONCLUSION: It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. KEY POINTS: • Abnormal hindfoot alignment can be identified on coronal non-weight-bearing MR images. • The sustentaculum tangent was the best predictor of an abnormally varus hindfoot. • The medial calcaneal contour was the best predictor of a valgus hindfoot.


Asunto(s)
Calcáneo/patología , Deformidades del Pie/patología , Pie/fisiopatología , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Algoritmos , Calcáneo/diagnóstico por imagen , Femenino , Pie/diagnóstico por imagen , Deformidades del Pie/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Curva ROC , Radiografía , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Soporte de Peso , Adulto Joven
5.
Arch Orthop Trauma Surg ; 132(1): 131-6, 2012 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-21874574

RESUMEN

INTRODUCTION: Wondering if the use of drains allowing re-transfusion of shed blood as opposed to closed suction drains or no drains would improve quality of care to patients undergoing simple non-cemented primary total hip replacement (THR) using a direct anterior approach, a three-arm prospective randomized study was conducted. METHOD: One hundred and twenty patients were prospectively randomized to receive no drain, closed suction drains or drains designed for re-transfusion of shed blood. Blood loss, VAS pain scores, thigh swelling, hematoma formation, number of dressings changed and hospital stay were compared and patients followed for 3 months. RESULTS: Drains did not have any significance on postoperative haemoglobin and haematocrit levels or homologous blood transfusion rates. Patients receiving homologous blood transfusions had too small drain volumes to benefit from re-transfusion and patients, who get drained fluid re-transfused, were far away from being in need of homologous blood transfusion. Omitting drains resulted in more thigh swelling accompanied with a tendency of slightly more pain during the first postoperative day but without effect on clinical and radiological outcome at 3 months. Earlier dry operation sites resulting in simplified wound care and shorter hospital stay was encountered when no drain was used. CONCLUSION: The possibility to re-transfuse drained blood was not an argument for using drains and, accepting more thigh swelling, we stop to use drains in simple non-cemented primary THR using the direct anterior approach.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Transfusión Sanguínea/métodos , Drenaje/métodos , Osteoartritis de la Cadera/cirugía , Anciano , Anciano de 80 o más Años , Pérdida de Sangre Quirúrgica , Transfusión Sanguínea/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Dimensión del Dolor , Complicaciones Posoperatorias , Estudios Prospectivos , Succión/métodos , Resultado del Tratamiento
6.
Eur Radiol ; 21(9): 1858-64, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21503835

RESUMEN

OBJECTIVES: To evaluate reliability of ultrasound for detection and quantification of glenohumeral joint effusion. METHODS: With institutional review board approval and informed consent ultrasound of 30 consecutive patients before and after MR arthrography of the shoulder was performed. Presence and width of any anechoic collection was noted within various locations (biceps tendon sheath, subscapular recess (neutral position and internal rotation), posterior glenohumeral joint recess (neutral position and external rotation)). Injected fluid (8-12 ml) into the glenohumeral joint served as gold-standard. Widths of anechoic collections were correlated (Spearman rank correlation) with injected fluid. RESULTS: Glenohumeral anechoic collection was consistently seen in the posterior glenohumeral joint recess with the arm in external rotation (100%, 30/30), and in the biceps tendon sheath (97%, 29/30). Ultrasound was not sensitive at other locations (7%-17%). Mean width in anterior-posterior direction of anechoic collection in the posterior glenohumeral joint recess was 7 mm (range: 3-18 mm), 2 mm (range: 1-7 mm) in the biceps tendon sheath. Significant correlation (R = 0.390, p = 0.033) was found between width of anechoic collection and injected fluid in the posterior glenohumeral joint recess. CONCLUSIONS: Glenohumeral joint effusion can be detected and quantified most reliably in the posterior glenohumeral joint recess with the arm in external rotation.


Asunto(s)
Exudados y Transudados/diagnóstico por imagen , Articulación del Hombro/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Adolescente , Adulto , Anciano , Artrografía/métodos , Estudios de Cohortes , Femenino , Humanos , Artropatías/diagnóstico por imagen , Artropatías/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Articulación del Hombro/fisiopatología , Adulto Joven
7.
AJR Am J Roentgenol ; 197(3): 578-82, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21862799

RESUMEN

OBJECTIVE: The purpose of this article is to identify the most rotation-stable hindfoot alignment measurement techniques on hindfoot alignment view and long axial view radiographs. MATERIALS AND METHODS: Hindfoot alignment was quantified on hindfoot alignment view and long axial view radiographs of a phantom in different rotation positions. Rotation stability of measurements using the calcaneal axis, the medial and lateral calcaneal contour, and the apparent moment arm were graphically compared. Interreader agreement was quantified using intraclass correlation coefficient. RESULTS: On hindfoot alignment view radiographs, measurements using the medial and lateral calcaneal contour were rotation stable (± 5°). Measurements using the calcaneal axis were not reliable and showed considerable divergence with phantom rotation. Measurements using the apparent moment arm manifested an almost linear relationship to phantom rotation. On long axial view radiographs, all measurements manifested an almost linear relationship to phantom rotation, whereas those using the calcaneal axis were the most rotation stable. Interreader agreement of all measurement techniques was perfect on both hindfoot alignment and long axial view radiographs (intraclass correlation coefficient, 0.8-0.98; p < 0.001). Interreader agreement was slightly better on long axial view radiographs. CONCLUSION: Hindfoot alignment measurements should be performed on hindfoot alignment view radiographs using the medial or lateral calcaneal contour or on long axial view radiographs using the calcaneal axis. Interreader agreement of hindfoot alignment measurements is slightly better on long axial view radiographs than on hindfoot alignment view radiographs.


Asunto(s)
Calcáneo/diagnóstico por imagen , Deformidades del Pie/diagnóstico por imagen , Pie/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Radiografía , Valores de Referencia , Rotación
8.
EFORT Open Rev ; 2(2): 51-57, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28461968

RESUMEN

The treatment of musculoskeletal neoplasms and infection is usually based on an initial diagnostic biopsy.Prior to biopsy, a hypothesis should be formed about the most likely diagnosis and a differential diagnosis. These deliberations should consider whether the lesion is a primary benign or malignant tumour, a metastasis, a haematological problem or an infection.A tactical plan should be developed which evaluates the necessity, the risk, the approach and finally defines the technique of biopsy most likely to achieve a representative result in the clinical case.In developing this technical approach, the pitfalls should be anticipated, i.e. inadequate sampling, difficulty of pathological interpretation and contamination.The tactical approach should be developed in conjunction with a multi-disciplinary team together with appropriate pre-biopsy imaging. Cite this article: EFORT Open Rev 2017;2:51-57. DOI: 10.1302/2058-5241.2.160065.

9.
Eur J Radiol ; 85(3): 518-23, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26860662

RESUMEN

OBJECTIVE: Stretchable coils allow knee imaging at varying degrees of flexion. Purpose was to compare a new-developed stretchable 8-channel to a standard 8-channel knee coil array by means of quantitative and qualitative image analysis. MATERIAL AND METHODS: IRB approved prospective study. Knee MR imaging in 10 healthy volunteers was performed at 3T using a standard 8-channel and a new-developed stretchable 8-channel coil array at 0°, 45°, and 60° of flexion and at 0° (standard coil). Image parameters were identical. Signal-to-noise ratio (SNR) was determined by combining the images with separately acquired noise data on a pixel-by-pixel basis using MATLAB routines (Natick, MA, USA). Images were qualitatively analysed by two independent radiologists who graded the visibility of several anatomic structures from 1=not visible to 5=excellent. ANOVA, Wilcoxon and kappa statistics were used. RESULTS: Mean SNR±standarddeviation of bone was 54.7±10.4 and of muscle 28.0± 4.4 using the stretchable coil array and 54.6±8.2 and 33.4±4.5, respectively, using the standard knee coil array. No statistically significant SNR differences were found between both arrays (bone, p=0.960; muscle, p=0.132). SNR was not degraded at higher degrees of flexion. The qualitative image analysis did not reveal statistically significant differences between the stretchable and standard coil array with regard to the visibility of anatomic structures (p=0.026-1.000). Overall kappa was 0.714. CONCLUSION: Stretchable 8-channel coil arrays provide similar SNR and visibility of anatomic structures compared to standard 8-channel knee coil arrays. MR imaging with high SNR will now be possible in flexed knees.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Articulación de la Rodilla/anatomía & histología , Imagen por Resonancia Magnética/métodos , Adulto , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Valores de Referencia , Relación Señal-Ruido
10.
Patient Saf Surg ; 5(1): 7, 2011 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-21496316

RESUMEN

INTRODUCTION: Total hip arthroplasty (THA) is one of the most frequently performed procedures in orthopaedics and weakness of external rotators is often recognized thereafter. However, the etiology of lateral hip pain is multifaceted. For the diagnosis of abductor tendon rupture, magnetic resonance imaging (MRI) is the gold standard. As not every patient can be subjected to MRI, a clinical diagnostic test for easy detection of lesions of the abductor tendon is missing. Here, we present the internal rotation lack sign indicating abductor tendon pathology. METHODS: The patient is placed in lateral position on a stretcher with hips and knees in neutral position. The knee is flexed to 45° and the hip passively abducted and elevated by the investigator. With the foot passively abducted, the patient is then asked to bring his knee in direction to the examination table. This motion is also tested passively. The test is regarded positive, if no internal rotation is possible and/or if this is painful. If groin pain is elicited during either of the exercises, the test is also rated positive. RESULTS: We evaluated this test in 20 patients clinically and by magnetic resonance imaging (MRI). All patients demonstrated a positive internal rotation lag sign. Twelve of them lag of internal rotation and evidence of anterior abductor tendon rupture on MRI, 8 with lag of internal rotation and no evidence of abductor tendon rupture. CONCLUSION: The new clinical diagnostic sign presented here may improve the diagnosis of abductor tendon rupture in the future. LEVEL OF EVIDENCE: Diagnostic study, level I.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA