RESUMEN
BACKGROUND: Machine learning (ML) can identify nonintuitive clinical variable combinations that predict clinical outcomes. To assess the potential predictive contribution of standardized Society of Thoracic Surgeons (STS) Database clinical variables, we used ML to detect their association with repair durability in ischemic mitral regurgitation (IMR) patients in a single institution study. METHODS: STS Database variables (n = 53) served as predictors of repair durability in ML modeling of 224 patients who underwent surgical revascularization and mitral valve repair for IMR. Follow-up mortality and echocardiography data allowed 1-year outcome analysis in 173 patients. Supervised ML analyses were performed using recurrence (≥3+ IMR) or death versus nonrecurrence (<3+ IMR) as the binary outcome classification. RESULTS: We tested standard ML and deep learning algorithms, including support vector machines, logistic regression, and deep neural networks. Following training, final models were utilized to predict class labels for the patients in the test set, producing receiver operating characteristic (ROC) curves. The three models produced similar area under the curve (AUC), and predicted class labels with promising accuracy (AUC = 0.72-0.75). CONCLUSIONS: Readily-available STS Database variables have potential to play a significant role in the development of ML models to direct durable surgical therapy in IMR patients.
Asunto(s)
Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Isquemia Miocárdica , Humanos , Aprendizaje Automático , Insuficiencia de la Válvula Mitral/cirugía , Isquemia Miocárdica/complicaciones , Isquemia Miocárdica/cirugía , Resultado del TratamientoRESUMEN
INTRODUCTION: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia, and results in significant morbidity and mortality. The Cox-Maze IV procedure (CMP-IV) has been shown to have excellent efficacy in returning patients to sinus rhythm, but there have been few reports of late follow-up in sizable cohorts of patients with longstanding persistent AF, the most difficult type of AF to treat. METHODS AND RESULTS: Between May 2003 and March 2020, 174 consecutive patients underwent a stand-alone CMP-IV for longstanding persistent AF. Rhythm outcome was assessed postoperatively for up to 10 years, primarily via prolonged monitoring (Holter monitor, pacemaker interrogation, or implantable loop recorder). Fine-Gray regression was used to investigate factors associated with atrial tachyarrhythmia (ATA) recurrence, with death as a competing risk. Median duration of preoperative AF was 7.8 years (interquartile range: 4.0-12.0 years), with 71% (124/174) having failed at least one prior catheter-based ablation. There were no 30-day mortalities. Freedom from ATAs was 94% (120/128), 83% (53/64), and 88% (35/40) at 1, 5, and 7 years, respectively. On regression analysis, preoperative AF duration and early postoperative ATAs were associated with late ATAs recurrence. CONCLUSION: Despite the majority of patients having a long-duration of preoperative AF and having failed at least one catheter-based ablation, the stand-alone CMP-IV had excellent late efficacy in patients with longstanding persistent AF, with low morbidity and no mortality. We recommend consideration of stand-alone CMP-IV for patients with longstanding persistent AF who have failed or are poor candidates for catheter ablation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Atrios Cardíacos , Humanos , Procedimiento de Laberinto , Recurrencia , Resultado del TratamientoRESUMEN
Aortic stenosis is the most prevalent valvular cardiovascular disease affecting the population over the age of 65 years. Transcatheter aortic valve replacement (TAVR) was developed as a minimally invasive surgical intervention to treat aortic stenosis in patients at high risk for surgical complications. Although the most commonly used approach for placement of a transcatheter aortic valve is in retrograde fashion via a transfemoral approach, narrowed luminal diameters, extensive atherosclerotic disease, or significant tortuosity may limit use of this route. In these patients, alternative methods including subclavian, transaortic, and transapical approaches should be considered. An understanding of these access routes and their respective indications and contraindications allows the radiologist to provide additional preprocedure measurements and images to help guide placement of the valve. ©RSNA, 2018.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Arteria Femoral , Corazón/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Humanos , Tomografía Computarizada MultidetectorRESUMEN
The development of transcatheter interventions to provide a minimally invasive alternative to open surgical repair has revolutionized the care of patients with valvular heart disease. Recently, this technology has been expanded to allow for the treatment of pathology of the mitral valve. This review discusses the anesthetic considerations for patients presenting for transcatheter management of mitral valve disease, including transcatheter mitral valve replacement (TMVR) and transcatheter mitral valve repair (TMVRep). The initial focus is on the current literature on transcatheter interventions for mitral valve pathologies as well as current and developing technology for TMVR and TMVRep. The authors' institutional experience with anesthetic management for the TMVR and TMVRep procedures is described, including potential pitfalls and complications, concluding with a discussion of the role of transesophageal echocardiography in the care of this patient population.
Asunto(s)
Anestesia/métodos , Anestésicos/administración & dosificación , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Anestesia/normas , Anestésicos/normas , Estenosis de la Válvula Aórtica/tratamiento farmacológico , Estenosis de la Válvula Aórtica/cirugía , Cateterismo Cardíaco/normas , Prótesis Valvulares Cardíacas/normas , Humanos , Insuficiencia de la Válvula Mitral/tratamiento farmacológico , Insuficiencia de la Válvula Mitral/cirugíaRESUMEN
AIM: The impact of paravalvular regurgitation (PVR) following transcatheter aortic valve replacement (TAVR) remains uncertain. In this analysis, we sought to evaluate the impact of varying degrees of PVR on both mortality and changes in ventricular geometry and function. METHODS AND RESULTS: Clinical and echocardiographic outcomes of patients who underwent TAVR from the randomized cohorts and continued access registries in the PARTNER trial were analysed after stratifying by severity of post-implant PVR, which was graded as none/trace in 52.9% (n = 1288), mild in 38.0% (n = 925), and moderate/severe in 9.1% (n = 221). There were significant differences in baseline clinical and echocardiographic characteristics. After TAVR, all the patients demonstrated increase in left ventricular (LV) function and reduction in the LV mass index, although the magnitude of mass regression was lower in the moderate/severe PVR group. The 30-day mortality (3.1 vs. 3.4 vs. 4.5%, P = 0.56) and stroke (3.4 vs. 3.7 vs. 2.3%, P = 0.59) were similar in all groups (none/trace, mild, and moderate/severe). At 1 year, there was increased all-cause mortality (15.9 vs. 22.2 vs. 35.1%, P < 0.0001), cardiac mortality (6.1 vs. 7.4% vs. 16.3%, P < 0.0001) and re-hospitalization (14.4 vs. 23.0 vs. 31.3%, P < 0.0001) with worsening PVR. A multivariable analysis indicated that the presence of moderate/severe PVR (HR: 2.18, 95% CI: 1.57-3.02, P < 0.0001) or mild PVR (HR: 1.37, 95% CI: 1.14-1.90, P = 0.012) was associated with higher late mortality. CONCLUSION: Differences in baseline characteristics in patients with increasing severities of PVR may increase the risk of this complication. Despite these differences, multivariable analysis demonstrated that both mild and moderate/severe PVR predicted higher 1-year mortality.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano de 80 o más Años , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/patología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/patología , Ecocardiografía , Femenino , Prolapso de las Válvulas Cardíacas , Humanos , Masculino , Insuficiencia de la Válvula Mitral/etiología , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/patología , Tamaño de los Órganos , Reoperación/estadística & datos numéricos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del TratamientoRESUMEN
BACKGROUND AND AIM OF THE STUDY: We studied patients presenting for coronary artery bypass grafting (CABG) with significant left main coronary artery disease (LMD) despite previously documented minimal or no LMD at percutaneous coronary intervention (PCI) for left-sided branch coronary artery disease. METHODS: Patients undergoing CABG for LMD with previous PCI were separated into fast or slow stenosis progression using percent change in LMD from first PCI to CABG divided by time (progression velocity). Outcomes and Kaplan-Meier survival were compared between the two groups. RESULTS: Between September 1997 and June 2010, 4837 patients underwent CABG with 1235 of them having previous PCI of which 118 had LMD and previous left-sided branch PCI. Using median progression velocity fast and slow progression groups were identified (0.53 ± 0.18 and 4.5 ± 4.8%/month, p < 0.001). Mean follow-up was 4.9 ± 3.6 years and 6.9 ± 3.9 years, respectively. Fast progression patients were younger (p = 0.042), with higher baseline LMD at PCI (16.4% vs. 9% stenosis, p = 0.025), and a mean of 2.5 years to LMD compared to 10.6 years for the slow group (p < 0.001). There was no difference between the groups in number or type of PCI and number or type of vessel intervened. Kaplan-Meier survival was similar at one, three, and five years. CONCLUSIONS: Fast LMD progression patients were younger and made up 4.7% (59/1235) of patients undergoing CABG with a history of PCI. Rapid progression was not related to number, type of PCI, or branch vessel intervened.
Asunto(s)
Puente de Arteria Coronaria , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea , Derivación y Consulta , Factores de Edad , Enfermedad de la Arteria Coronaria/mortalidad , Progresión de la Enfermedad , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Tasa de Supervivencia , Tiempo , Resultado del TratamientoRESUMEN
The use of surgical lesion sets for the treatment of atrial fibrillation has been increasing, particularly in patients with complicated anatomical substrates and those undergoing concomitant surgery. Preferences in terms of lesion set, surgical approach and ablation technology vary by center. This review discusses both the surgical techniques and the outcomes for the most commonly performed procedures in the context of recent consensus guidelines. The Cox-Maze IV, pulmonary vein isolation, extended left atrial lesion sets, the hybrid approach and ganglionated plexus ablation are each reviewed in an attempt to provide insight into current clinical practice and patient selection.
Asunto(s)
Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Fibrilación Atrial/patología , Fibrilación Atrial/fisiopatología , Procedimientos Quirúrgicos Cardíacos/normas , HumanosRESUMEN
This document discusses preprocedural planning for transcatheter aortic valve replacement, evaluating the imaging modalities used in initial imaging for preprocedure planning under two variants 1) Preintervention planning for transcatheter aortic valve replacement: assessment of aortic root; and 2) Preintervention planning for transcatheter aortic valve replacement: assessment of supravalvular aorta and vascular access. US echocardiography transesophageal, MRI heart function and morphology without and with IV contrast, MRI heart function and morphology without IV contrast and CT heart function and morphology with IV contrast are usually appropriate for assessment of aortic root. CTA chest with IV contrast, CTA abdomen and pelvis with IV contrast, CTA chest abdomen pelvis with IV contrast are usually appropriate for assessment of supravalvular aorta and vascular access. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.
Asunto(s)
Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Imagen por Resonancia Magnética , Sociedades Médicas , Tomografía Computarizada por Rayos X/métodos , Estados UnidosRESUMEN
Aortic stenosis is the most common form of valvular heart disease in the Western world and until recently, surgical aortic valve replacement has been the only treatment available for patients with this disease that has been shown to improve both symptoms and survival. Transcatheter aortic valve replacement has emerged as a new therapy for patients with severe aortic stenosis who are poor surgical candidates due to their elevated surgical risk. As longer follow up is obtained and improvements continue to be made in the current available prostheses, transcatheter aortic valve replacement will likely become a treatment alternative for high-risk patients with severe aortic stenosis.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estenosis de la Válvula Aórtica/epidemiología , Bioprótesis , Cateterismo Cardíaco , Progresión de la Enfermedad , Prótesis Valvulares Cardíacas , Humanos , Selección de Paciente , Resultado del TratamientoRESUMEN
OBJECTIVES: Stand-alone surgical ablation of atrial fibrillation is indicated in patients with refractory atrial fibrillation who have failed medical or catheter-based ablation. Few reports of late outcomes after stand-alone surgical ablation exist using comprehensive follow-up with strict definitions of success. This study examined our late outcomes of the stand-alone Cox-Maze IV procedure. METHODS: Between January 2003 and December 2019, 236 patients underwent a stand-alone Cox-Maze IV for refractory atrial fibrillation. Freedom from atrial tachyarrhythmias was assessed by electrocardiography, Holter, or pacemaker interrogation for up to 10 years, with a mean follow-up of 4.8 ± 3.5 years. Rhythm outcomes were compared in multiple subgroups. Factors associated with recurrence were determined using Fine-Gray regression, allowing for death as the competing risk. RESULTS: The majority of patients (176/236, 75%) had nonparoxysmal atrial fibrillation. Median duration of preoperative atrial fibrillation was 6.2 years (interquartile range, 3-11). Fifty-nine percent of patients (140/236) failed 1 or more prior catheter-based ablation. Thirteen patients (6%) experienced a major complication. There was no 30-day mortality. Freedom from atrial tachyarrhythmias was 94% (187/199), 89% (81/91), and 77% (24/31) at 1, 5, and 10 years, respectively. There was no difference in freedom from atrial tachyarrhythmias between patients with paroxysmal atrial fibrillation versus nonparoxysmal atrial fibrillation (P > .05) or those undergoing sternotomy versus a minimally invasive approach (P > .05). Increased left atrial size and number of catheter ablations were associated with late atrial fibrillation recurrence. For patients who experienced any atrial tachyarrhythmia recurrence, the median number of recurrences was 1.5 (1.0-3.0). CONCLUSIONS: The stand-alone Cox-Maze IV had excellent late efficacy at maintaining sinus rhythm in patients with symptomatic, refractory atrial fibrillation, with low morbidity and no mortality. The Cox-Maze IV, in contrast to catheter-based ablation, was equally effective in patients with paroxysmal and nonparoxysmal atrial fibrillation.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/etiología , Electrocardiografía/métodos , Atrios Cardíacos/cirugía , Humanos , Recurrencia , Resultado del TratamientoRESUMEN
BACKGROUND: Acute kidney injury (AKI) after cardiac surgery remains a common complication that has been associated with increased morbidity and mortality. This study implemented Kidney Disease Improving Global Outcomes criteria to evaluate renal outcomes after concomitant surgical ablation for atrial fibrillation. METHODS: Patients with a history of atrial fibrillation who underwent elective cardiac surgery at our institution from 2008 to 2018 were retrospectively reviewed. Those with preoperative renal dysfunction were excluded. Patients were classified as those who underwent concomitant Cox-Maze IV (CMP-IV) (n = 376) or no surgical ablation (n = 498). Nearest neighbor 1:1 propensity matching was conducted on fourteen covariates. AKI was evaluated by mixed effects logistic regression analysis. Long-term survival was evaluated by proportional hazards regression. RESULTS: Propensity matching yielded 308 patients in each group (n = 616). All preoperative variables were similar between groups. The concomitant CMP-IV group had a greater incidence of AKI: 32% (n = 99) versus 16% (n = 49), P < .001. After accounting for bypass time and nonablation operations on mixed effects analysis, concomitant CMP-IV was associated with increased risk of AKI (odds ratio, 1.89; confidence interval, 1.12-3.18; P = .017). While AKI was associated with decreased late survival (P < .001), patients who received a concomitant CMP-IV maintained superior 7-year survival to patients who received no ablation (P < .001). No patients required permanent dialysis. CONCLUSIONS: Concomitant CMP-IV was independently associated with increased risk of AKI in the acute postoperative period. However, the long-term risks of AKI were offset by the significant survival benefit of CMP-IV. Concerns regarding new-onset renal dysfunction should not prohibit recommendation of this procedure in appropriate patients.
Asunto(s)
Lesión Renal Aguda , Fibrilación Atrial , Humanos , Lesión Renal Aguda/epidemiología , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Complicaciones Posoperatorias , Diálisis Renal/efectos adversos , Estudios Retrospectivos , Factores de Riesgo , Resultado del TratamientoRESUMEN
OBJECTIVE: Surgical ablation of atrial fibrillation (AF) is indicated both in patients with AF undergoing concomitant cardiac surgery and in those who have not responded to medical and/or catheter-based ablation therapy. This study examined our long-term outcomes following the Cox-Maze IV procedure (CMP-IV). METHODS: Between May 2003 and March 2018, 853 patients underwent either biatrial CMP-IV (n = 765) or a left-sided CMP-IV (n = 88) lesion set with complete isolation of the posterior left atrium. Freedom from atrial tachyarrhythmia (ATA) was assessed for up to 10 years. Rhythm outcomes were compared in multiple subgroups. Predictors of recurrence were determined using Fine-Gray regression, allowing for death as the competing risk. RESULTS: The majority of patients (513/853, 60%) had nonparoxysmal AF. Twenty-four percent of patients (201/853) had not responded to at least 1 catheter-based ablation. Prolonged monitoring was used in 76% (647/853) of patients during their follow-up. Freedom from ATA was 92% (552/598), 84% (213/253), and 77% (67/87) at 1, 5, and 10 years, respectively. By competing risk analysis, incidence of first ATA recurrence was 11%, 23%, and 35% at 1, 5, and 10 years, respectively. On Fine-Gray regression, age, peripheral vascular disease, nonparoxysmal AF, left atrial size, early postoperative ATAs, and absence of sinus rhythm at discharge were the predictors of first ATA recurrence over 10 years of follow-up. CONCLUSIONS: The CMP-IV had an excellent long-term efficacy at maintaining sinus rhythm. At late follow-up, the results of the CMP-IV remained superior to those reported for catheter ablation and other forms of surgical ablation for AF. Age, left atrial size, and nonparoxysmal AF were the most relevant predictors of late recurrence.
Asunto(s)
Fibrilación Atrial/cirugía , Atrios Cardíacos/cirugía , Procedimiento de Laberinto , Potenciales de Acción , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Bases de Datos Factuales , Femenino , Atrios Cardíacos/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Procedimiento de Laberinto/efectos adversos , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
Aortic valve replacement (AVR) is common in the setting of type A aortic dissection (TAAD) repair. Here, we evaluated the association between prosthesis choice and patient outcomes in an international patient cohort. We reviewed data from the International Registry of Acute Aortic Dissection (IRAD) interventional cohort to examine the relationship between valve choice and short- and mid-term patient outcomes. Between January 1996 and March 2016, 1290 surgically treated patients with TAAD were entered into the IRAD interventional cohort. Of those, 364 patients undergoing TAAD repair underwent aortic valve replacement (AVR; mean age, 57 years). The mechanical valve cohort consisted of 189 patients, of which 151 (79.9%) had a root replacement. The nonmechanical valve cohort consisted of 5 patients who received homografts and 160 patients who received a biologic AVR, with a total of 118 (71.5%) patients who underwent root replacements. The mean follow-up time was 2.92 ± 1.75 years overall (2.46 ± 1.69 years for the mechanical valve cohort and 3.48 ± 1.8 years for the nonmechanical valve cohort). After propensity matching, Kaplan-Meier estimates of 4-year survival rates after surgery were 64.8% in the mechanical valve group compared with 74.7% in the nonmechanical valve group (p = 0.921). A stratified Cox model for 4-year mortality showed no difference in hazard between valve types after adjusting for the propensity score (p = 0.854). A biologic valve is a reasonable option in patients with TAAD who require AVR. Although this option avoids the potential risks of anticoagulation, long-term follow up is necessary to assess the effect of reoperations or transcatheter interventions for structural valve degeneration.
Asunto(s)
Disección Aórtica , Prótesis Valvulares Cardíacas , Disección Aórtica/cirugía , Válvula Aórtica/cirugía , Productos Biológicos , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
Increased right atrial (RA) and ventricular (RV) chamber volumes are a late maladaptive response to chronic pulmonary hypertension. The purpose of the current investigation was to characterize the early compensatory changes that occur in the right heart during chronic RV pressure overload before the development of chamber dilation. Magnetic resonance imaging with radiofrequency tissue tagging was performed on dogs at baseline and after 10 wk of pulmonary artery banding to yield either mild RV pressure overload (36% rise in RV pressure; n = 5) or severe overload (250% rise in RV pressure; n = 4). The RV free wall was divided into three segments within a midventricular plane, and circumferential myocardial strain was calculated for each segment, the septum, and the left ventricle. Chamber volumes were calculated from stacked MRI images, and RA mechanics were characterized by calculating the RA reservoir, conduit, and pump contribution to RV filling. With mild RV overload, there were no changes in RV strain or RA function. With severe RV overload, RV circumferential strain diminished by 62% anterior (P = 0.04), 42% inferior (P = 0.03), and 50% in the septum (P = 0.02), with no change in the left ventricle (P = 0.12). RV filling became more dependent on RA conduit function, which increased from 30 ± 9 to 43 ± 13% (P = 0.01), than on RA reservoir function, which decreased from 47 ± 6 to 33 ± 4% (P = 0.04), with no change in RA pump function (P = 0.94). RA and RV volumes and RV ejection fraction were unchanged from baseline during either mild (P > 0.10) or severe RV pressure overload (P > 0.53). In response to severe RV pressure overload, RV myocardial strain is segmentally diminished and RV filling becomes more dependent on RA conduit rather than reservoir function. These compensatory mechanisms of the right heart occur early in chronic RV pressure overload before chamber dilation develops.
Asunto(s)
Función del Atrio Derecho , Hipertensión Pulmonar/complicaciones , Disfunción Ventricular Derecha/etiología , Función Ventricular Derecha , Presión Ventricular , Adaptación Fisiológica , Animales , Fenómenos Biomecánicos , Presión Sanguínea , Constricción , Modelos Animales de Enfermedad , Perros , Hipertensión Pulmonar Primaria Familiar , Hipertensión Pulmonar/fisiopatología , Hipertrofia Ventricular Derecha/etiología , Hipertrofia Ventricular Derecha/fisiopatología , Imagen por Resonancia Magnética , Arteria Pulmonar/fisiopatología , Arteria Pulmonar/cirugía , Índice de Severidad de la Enfermedad , Estrés Mecánico , Volumen Sistólico , Factores de Tiempo , Disfunción Ventricular Derecha/fisiopatologíaRESUMEN
OBJECTIVE: Obesity is a strong and independent factor for the development of atrial fibrillation (AF), and adversely impacts the success of catheter ablation procedures for AF. This study evaluated the impact of body mass index (BMI) on the outcomes following surgical ablation of AF. METHODS: Between 2003 and 2019, 236 patients underwent a stand-alone biatrial Cox maze IV procedure (CMP-IV) for refractory AF. Obesity was defined as BMI ≥30 kg/m2. Patients were divided into two groups: BMI <30 kg/m2 (n = 100) and BMI ≥30 kg/m2 (n = 136). Freedom from atrial tachyarrhythmia (ATA) was determined using electrocardiography, Holter, or pacemaker interrogation at 1 year and annually thereafter. Recurrence was defined as any documented ATA lasting ≥30 s. Predictors of recurrence were determined using multivariable logistic regression. Preoperative and procedural outcomes were compared between groups. RESULTS: Obese patients had a higher rate of diabetes (16% vs 7%, P = 0.044) and larger left atrial diameter (4.9 ± 1.1 cm vs 4.6 ± 1.0 cm, P = 0.021) when compared to non-obese patients. There was no difference in major complication rate between the groups (4% vs 7%, P = 0.389). There was no operative mortality in either group. During 4.1 ± 2.4 years of follow-up, there was no significant difference in freedom from ATA with or without antiarrhythmic drugs in obese patients when compared to the non-obese group (P > 0.05). Absence of sinus rhythm at discharge predicted AF recurrence up to 7 years postoperatively. CONCLUSIONS: As opposed to catheter ablation, obesity did not adversely impact the short and long-term outcomes of stand-alone surgical ablation with CMP-IV, and BMI was not a predictor of AF recurrence. Additionally, there was no significant increase in major complications in obese patients.
Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Humanos , Procedimiento de Laberinto , Obesidad/complicaciones , Obesidad/epidemiología , Resultado del TratamientoRESUMEN
BACKGROUND: At a Midwestern academic medical center, we introduced a structured teamwork training program to cardiothoracic operating room members with a goal of greater than or equal to 90% reporting positive psychological safety after the program. METHODS: We conducted teamwork training over 3 months. We distributed confidential questionnaires before the training, and then at 6 months and 12 months after the training. The primary outcome was the percentage of respondents reporting good or excellent psychological safety. Surveys were also distributed at the end of each case. Secondary outcomes were medical errors reported. Comparisons between percentages were evaluated with chi-square test. We examined the turnover of nurses and surgical technologists. RESULTS: Positive psychological safety was reported by 57 of 73 (78.1%) at baseline and by 60 of 68 (88.2%) at 12 months (difference = 10.1%; 95% confidence interval, -2.4% to 23.4%; P = .122). On the daily survey, 93.9% (n = 2786 of 2987) of operating room team members strongly agreed with the statement "I felt comfortable speaking up with questions and concerns" during the last quarter of the study. Reported medical errors decreased from 7.44% (n = 78 of 1048) in the first 6 months of the study to 4.65% (n = 55 of 1184) in the second 6 months (difference = 2.79%; 95% confidence interval, 0.8% to 4.8%; P = .005). In 2015, 19 nurses of a pool of 40 (47.5%) left, followed by 7 (17.5%) in 2016 and 10 (25%) in 2017. CONCLUSIONS: Overall, the results of this study suggest that structured teamwork training in the cardiothoracic operating room environment has the potential to improve teamwork, psychological safety, and communication, and potentially also patient outcomes.
Asunto(s)
Conducta Cooperativa , Personal de Salud/psicología , Errores Médicos/estadística & datos numéricos , Grupo de Atención al Paciente , Centros Médicos Académicos , Actitud del Personal de Salud , Estudios de Cohortes , Comunicación , Humanos , Seguridad del PacienteRESUMEN
OBJECTIVES: The incidence of atrial fibrillation (AF) in patients older than 75 years of age is expected to increase, and its treatment remains challenging. This study evaluated the impact of age on the outcomes of surgical ablation of AF. METHODS: A retrospective review was performed of patients who underwent the Cox-maze IV procedure at a single institution between 2005 and 2017. The patients were divided into a younger (age <75 years, n = 548) and an elderly cohort (age ≥75 years, n = 148). Rhythm outcomes were assessed at 1 year and annually thereafter. Predictors of first atrial tachyarrhythmia (ATA) recurrence were determined using Fine-Gray regression, allowing for death as the competing risk. RESULTS: The mean age of the elderly group was 78.5 ± 2.8 years. The majority of patients (423/696, 61%) had nonparoxysmal AF. The elderly patients had a lower body mass index (P < .001) and greater rates of hypertension (P = .011), previous myocardial infarction (P = .017), heart failure (P < .001), and preoperative pacemaker (P = .008). Postoperatively, the elderly group had a greater rate of overall major complications (23% vs 14%, P = .017) and 30-day mortality (6% vs 2%, P = .026). The percent freedom from ATAs and antiarrhythmic drugs was lower in the elderly patients at 3 (69% vs 82%, P = .030) and 4 years (65% vs 79%, P = .043). By competing risk analysis, the incidence of first ATA recurrence was greater in elderly patients (33% vs 20% at 5 years; Gray test, P = .005). On Fine-Gray regression adjusted for clinically relevant covariates, increasing age was identified as a predictor of ATAs recurrence (subdistribution hazard ratio, 1.03; 95% confidence interval, 1.02-1.05, P < .001). CONCLUSIONS: The efficacy of the Cox-maze IV procedure was worse in elderly patients; however, the majority of patients remained free of ATAs at 5 years. The lower success rate in these greater-risk patients should be considered when deciding to perform surgical ablation.
Asunto(s)
Fibrilación Atrial/cirugía , Procedimiento de Laberinto/efectos adversos , Factores de Edad , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Fibrilación Atrial/fisiopatología , Femenino , Humanos , Incidencia , Masculino , Procedimiento de Laberinto/mortalidad , Persona de Mediana Edad , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
Variability exists regarding the timing and duration of anticoagulation after surgical ablation for atrial fibrillation and bioprosthetic mitral valve replacement (MVR). We report a case in which a patient developed a massive left atrial (LA) thrombus after MVR and left-sided radiofrequency ablation (LRFA). Despite acutely elevated gradients across the bioprosthetic valve, the patient remained asymptomatic and hemodynamically stable; thus, a multidisciplinary, patient-centered discussion was had and the patient was treated successfully with oral anticoagulation.
Asunto(s)
Anticoagulantes/uso terapéutico , Fibrilación Atrial/cirugía , Cardiopatías/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Insuficiencia de la Válvula Mitral/cirugía , Ablación por Radiofrecuencia/efectos adversos , Trombosis/etiología , Bioprótesis , Ecocardiografía , Femenino , Atrios Cardíacos , Cardiopatías/tratamiento farmacológico , Humanos , Persona de Mediana Edad , Válvula Mitral/cirugía , Cuidados Posoperatorios , Complicaciones Posoperatorias/prevención & control , Factores de Riesgo , Trombosis/tratamiento farmacológicoRESUMEN
BACKGROUND: Transcatheter aortic valve replacement (TAVR) and transcatheter mitral valve replacement expose operators to radiation. These procedures differ primarily in whether they are performed via a transfemoral (TF) or an alternative access (AA) approach. This study compared operator radiation exposure during transcatheter valve implantation when performed via a TF vs an AA approach, when performed in a catheterization lab vs a hybrid operating room (OR), and investigated the potential benefit of disposable shielding. METHODS: Dosimeters were worn during TAVR-TF (n = 50) and TAVR-AA (n = 31) procedures by operators. All TAVR-AA procedures were performed in a hybrid OR and TF procedures were performed in either catheterization labs (n = 16) or a hybrid OR (n = 34). Disposable radiation shielding pads (RADPAD; Worldwide Innovations and Technologies, Inc, Kansas City) or a placebo were added in a randomized, blinded fashion. RESULTS: Team radiation exposure was higher after TAVR-AA vs TAVR-TF (median 15.1 mRad [interquartile range: IQR 8.6, 32.4] vs 5.5 mRad [IQR 2.4, 9.8], P < .001). TAVR-TF procedures required the same amount of fluoroscopy time regardless of where they were performed (20.3 ± 7.4 min in hybrid OR vs 19.0 ± 6.4 min in catheterization lab, P = .55). However, radiation exposure for TAVR-TF remained higher when performed in a hybrid OR (median 9.0 mRad [IQR 4.5, 11.9] vs 2.2 mRad [IQR 1.3, 2.8], P < .001). Radiation exposure was greatest for TAVR-AA (median 15.1 mRad [IQR 8.6, 32.4]). The use of RADPAD did not decrease radiation exposure (median 9.0 mRad [IQR 4.5, 14.7] vs 9.4 mRad [IQR 2.8, 19.5], P = .82). CONCLUSIONS: Procedures performed in the hybrid OR were associated with higher operator radiation exposure. In comparison with the TF approach, AA cases had the highest levels of operator radiation. This is particularly important in cases of transcatheter mitral valve replacement that can only be done via an AA approach. The use of disposable radiation shielding in this series did not attenuate operator radiation exposure. Radiation shielding within hybrid ORs should be scrutinized in an effort to remain on par with that found within catheterization labs.
Asunto(s)
Exposición Profesional/prevención & control , Dosis de Radiación , Exposición a la Radiación/prevención & control , Protección Radiológica , Cirugía Torácica , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Arteria Femoral , Humanos , Método Simple CiegoRESUMEN
BACKGROUND: Learning curves and skill attrition with aging have been reported to impair outcomes in select surgical subspecialties, but their role in complex cardiac surgery remains unknown. METHODS: From 1986 to 2019, 2314 patients underwent reoperative cardiac surgery: coronary artery bypass grafting (n = 543), valve (n = 1527), or combined coronary artery bypass grafting and valve (n = 244). Thirty-four different surgeons in practice between 1 and 39 years were included. Standardized mortality ratio (observed-to-expected) was determined for all surgeons in each post-training year of experience. RESULTS: Risk-adjusted cumulative sum change-point analysis was used to define five distinct career phases: 0 to 4 years, 5 to 8 years, 9 to 17 years, 18 to 28 years, and 29 to 39 years. With 5 to 8 years and 18 to 28 years of experience, standardized mortality ratio was near unity (0.95 and 1.05, respectively) and lowest with 9 to 17 years of experience (0.78, P = .03). In the youngest experience group (0 to 4 years), observed and expected mortality were both highest, and standardized mortality ratio was elevated at 1.29, which approached statistical significance (P = .059). In the oldest experience group (29 to 39 years), expected mortality was low compared with most other groups but observed mortality increased, yielding a significantly elevated standardized mortality ratio at 1.53 (P = .032). CONCLUSIONS: Standardized mortality ratios with reoperative cardiac surgery were highest early and late in a surgeon's career and lowest in mid career. As surgeons gain experience, outcomes improve through the first two career decades, then stabilize in the third decade before declining in the fourth decade.