Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Surg Res ; 258: 200-212, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33035743

RESUMEN

BACKGROUND: To minimize complications associated with the construction of the hand-sewn aortic anastomosis, alternative experimental methods have been pursued. This study aimed to evaluate the efficacy of experimental anastomotic devices in relation to time and point of rupture of the anastomosis in comparison to the conventional technique. MATERIALS AND METHODS: An electronic search was performed using MEDLINE, Scopus, Science Direct, and Cochrane Library databases by two independent authors. Our exclusion criteria referred to studies reporting results solely from end-to-side anastomosis, results on vessels other than the aorta, studies that did not involve animal experiments, and non-English publications. The last search date was January 1, 2020. RESULTS: The meta-analysis included 22 studies with 34 anastomosis samples and a total of 316 animals. The pooled mean automated anastomosis time was 10.38 min, and the mean point of rupture was 32.7 N. In the subgroup analysis of automated anastomosis time by device category, the anastomotic stenting technique reported significantly lower anastomosis time but also showed significantly lower point of rupture. Comparing the efficacy of experimental devices and the hand-sewn technique, our pooled analysis showed that automated devices significantly decrease the time needed to perform the anastomosis (weighted mean difference -7.24 min). On the other hand, the automated anastomosis is also associated with decreased tensile strength (weighted mean difference -20.68 N). CONCLUSIONS: Although experimental devices seem to offer a faster anastomosis, they lack endurance when compared with the hand-sewn technique. Further research is needed for the development of an "ideal" anastomotic technique.


Asunto(s)
Anastomosis Quirúrgica/instrumentación , Aorta/cirugía , Anastomosis Quirúrgica/estadística & datos numéricos , Animales , Técnicas de Sutura , Factores de Tiempo
2.
J Pers Med ; 11(12)2021 Dec 20.
Artículo en Inglés | MEDLINE | ID: mdl-34945857

RESUMEN

BACKGROUND: Hand-sewn anastomosis is a crucial part of aortic reconstruction surgery and significantly affects its outcome. The present study presents a novel, bidirectional surgical needle aimed to improve aortic anastomosis in terms of speed and ease of use. Our objective was to assess the efficacy of the new design in comparison with the conventional needle. METHODS: A series of simulations were conducted with COMSOL software in order to perform a fatigue comparative analysis between the new and the conventional needle design. Ease of penetration into a piece of polydimethylsiloxane was evaluated. Lastly, the prototype was tested under in-vitro conditions in comparison with the conventional needle. RESULTS: Based on fatigue analysis, the new needle design improves durability, provided the two tips are equally used. The polytetrafluoroethylene coating improves penetration into the tissue by 7% to 17%, while electropolishing improves penetration up to 19%. When using the novel needle design, the average anastomotic task completion time was significantly reduced by 22% and the overall distance of hand movements was significantly reduced by 20%. CONCLUSIONS: The proposed design exhibited a shorter anastomotic time and seems promising in relation to ease of use and simplicity of the anastomotic technique it introduces.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA