Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Arthroplasty ; 32(10): 3228-3237.e2, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28641970

RESUMEN

BACKGROUND: Outcomes after unicompartmental knee arthroplasty (UKA) are variable and influenced by caseload (UKA/y) and usage (percentage of knee arthroplasty that are UKA), which relates to indications. This meta-analysis assesses the relative importance of these factors. METHODS: MEDLINE (Ovid), Embase (Ovid), and Web of Science (ISI) were searched for consecutive series of cemented Phase 3 Oxford medial UKA. The primary outcome was revision rate/100 observed component years (% pa) with subgroup analysis based on caseload and usage. RESULTS: Forty-six studies (12,520 knees) with an annual revision-rate ranging from 0% to 4.35% pa, mean 1.21% pa (95% confidence interval [CI], 0.97-1.47), were identified. In series with mean follow-up of 10-years, the revision-rate was 0.63% pa (95% CI, 0.46-0.83), equating to a 94% (95% CI, 92%-95%) 10-year survival. Aseptic loosening, lateral arthritis, bearing dislocation, and unexplained pain were the predominant failure mechanisms with revision for patellofemoral problems and polyethylene wear exceedingly rare. The lowest revision-rates were achieved with caseload >24 UKA/y (0.88% pa; 95% CI, 0.63-1.61) and usage >30% (0.69% pa; 95% CI, 0.50-0.90). Usage was more important than caseload; with high usage (≥20%), the revision-rate was low, whether the caseload was high (>12 UKA/y) or low (≤12 UKA/y; (0.94% pa; 95% CI, 0.69-1.23 and 0.85% pa; 95% CI, 0.65-1.08), respectively); with low usage (<20%), the revision-rate was high, whether the caseload was high or low (1.58% pa; 95% CI, 0.57-3.05 and 1.76% pa; 95% CI, 1.21-2.41, respectively). CONCLUSION: To achieve optimum results, surgeons, whether high or low caseload, should adhere to the recommended indications such that ≥20%, or ideally >30% of their knee arthroplasties are UKA. If they do this, then they can expect to achieve results similar to those of the long-term series, which all had high usage (>20%) and an average 10-year survival of 94%.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla/estadística & datos numéricos , Falla de Prótesis/etiología , Artroplastia de Reemplazo de Rodilla/estadística & datos numéricos , Humanos , Osteoartritis de la Rodilla/cirugía , Polietileno , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
2.
J Orthop Surg Res ; 15(1): 239, 2020 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-32600340

RESUMEN

BACKGROUND: Joints withstand huge forces, but little is known about subchondral pressures and perfusion during loading. We developed an in vitro calf foot model to explore intraosseous pressure (IOP) and subchondral perfusion during weight bearing. METHODS: Freshly culled calf forefeet were perfused with serum. IOP was measured at three sites in the foot using intraosseous needles, pressure transducers, and digital recorders. IOP was measured during perfusion, with and without a tourniquet and with differing weights, including static loading and dynamic loading to resemble walking. RESULTS: IOP varied with perfusion pressure. Static loading increased subchondral IOP whether the bone was non-perfused, perfused, or perfused with a proximal venous tourniquet (p < 0.0001). Under all perfusion states, IOP was proportional to the load (R2 = 0.984). Subchondral IOP often exceeded perfusion pressure. On removal of a load, IOP fell to below the pre-load value. Repetitive loading led to a falling IOP whether the foot was perfused or not. CONCLUSION: Superimposed on a variable background IOP, increased perfusion and physiological loading caused a significant increase in subchondral IOP. Force was thereby transmitted through subchondral bone partly by hydraulic pressure. A falling IOP with repeat loading suggests that there is an intraosseous one-way valve. This offers a new understanding of subchondral perfusion physiology.


Asunto(s)
Articulación del Tobillo/fisiología , Articulaciones del Pie/fisiología , Perfusión , Soporte de Peso/fisiología , Animales , Fenómenos Biomecánicos , Bovinos , Técnicas In Vitro , Masculino , Presión , Suero , Transductores de Presión
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA