RESUMEN

PURPOSE: Management of head and neck cancers (HNC) in older adults is a common but challenging clinical scenario. We assess the impact of Stereotactic Body Radiation Therapy (SBRT) on survival utilizing the Geriatric-8 (G8) questionnaire. MATERIALS AND METHODS: 171 HNC patients, deemed medically unfit for definitive treatment, were treated with SBRT ± systemic therapy. G8 questionnaires were collected at baseline, at 4-6 weeks, and at 2-3 months post-treatment. Patients were stratified according to their baseline G8 score: <11 as 'vulnerable', 11-14 as 'intermediate', and >14 as 'fit'. Overall survival (OS) was assessed through univariate Kaplan Meier analysis. Repeated measures ANOVA was used to determine if baseline characteristics affected G8 score changes. RESULTS: Median follow-up was seventeen months. 60% of patients presented with recurrent HNC, 30% with untreated HNC primaries, and 10% with metastatic non-HNC primaries. Median age was 75 years. Median Charlson Comorbidity Index score was 2. 51% of patients were 'vulnerable', 37% were 'intermediate', and 12% were 'fit' at baseline, with median survival of 13.2, 24.3, and 41.0 months, respectively (p = .004). Patients who saw a decrease in their follow-up G8 score (n = 69) had significantly lower survival than patients who had stable or increased follow-up G8 scores (n = 102), with median survival of 8.6 vs 36.0 months (p < .001). CONCLUSION: The G8 questionnaire may be a useful tool in upfront treatment decision-making to predict prognosis and prevent older patients from receiving inappropriate anti-cancer treatment. Decline in follow-up G8 scores may also predict worse survival and aid in goals of care following treatment.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radiocirugia , Anciano , Evaluación Geriátrica , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Recurrencia Local de Neoplasia , Encuestas y Cuestionarios
2.
Radiat Oncol ; 15(1): 278, 2020 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-33308265

RESUMEN

BACKGROUND AND PURPOSE: Patients with locally advanced oropharynx squamous cell carcinoma have suboptimal outcomes with standard chemoradiation. Here, we evaluated toxicity and oncologic outcomes of dose escalation using radiosurgical boost for patients with unfavorable oropharynx squamous cell carcinoma. MATERIALS AND METHODS: Between 2010-2017, Thirty four patients with intermediate- or high-risk oropharynx squamous cell carcinoma were enrolled onto this prospective phase I trial. Each patient received concurrent cisplatin and fractionated radiotherapy totaling 60 Gy or 66 Gy followed by radiosurgery boost to areas of residual gross tumor: single fraction of 8 Gy or 10 Gy, or two fractions of 5 Gy each. Primary endpoint was treatment toxicity. Secondary endpoints were local, regional, and distant disease control. RESULTS: Eleven, sixteen and seven patients received radiosurgery boost with 8 Gy in 1 fraction, 10 Gy in 1 fraction, and 10 Gy in 2 fractions respectively. Acute toxicities include 4 patients with tumor necrosis causing grade 3 dysphagia, of which 3 developed grade 4 pharyngeal hemorrhage requiring surgical intervention. At 24 months after treatment, 7%, 9%, and 15% had grade 2 dysgeusia, xerostomia, and dysphagia, respectively, and two patients remained feeding tube dependent. No grade 5 toxicities occurred secondary to treatment. Local, regional, and distant control at a median follow up of 4.2 years were 85.3%, 85.3% and 88.2%, respectively. Five patients died resulting in overall survival of 85.3%. CONCLUSIONS: This study is the first to report the use of radiosurgery boost dose escalation in patients with unfavorable oropharynx squamous cell carcinoma. Longer follow-up, larger cohorts, and further refinement of boost methodology are needed prior to implementation in routine clinical practice. TRIAL REGISTRATION: Northwell Health Protocol #09-309A (NCT02703493) ( https://clinicaltrials.gov/ct2/show/NCT02703493 ).


Asunto(s)
Neoplasias Orofaríngeas/radioterapia , Radiocirugia/métodos , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Orofaríngeas/mortalidad , Estudios Prospectivos , Radiocirugia/efectos adversos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Carcinoma de Células Escamosas de Cabeza y Cuello/mortalidad
3.
Front Oncol ; 9: 836, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31552172

RESUMEN

Purpose: To present a retrospective analysis of the efficacy, toxicity, and quality of life (QoL) of patients treated with OAR Extreme -sparing stereotactic body radiotherapy (SBRT) in previously-irradiated head and neck cancer. Materials/Methods: From 11/2012 to 7/2015, 60 patients with in-field recurrence of head and neck cancer underwent re-irradiation with SBRT. Retreatment sites included the aerodigestive tract (43%), lateral neck (22%), and skull base (35%). The median prior RT dose was 63.6 Gy with a median time from prior irradiation of 16.5 months. The median volume treated was 61.0 cc. Patients were treated with 40 Gy in the definitive setting or 35 Gy in the post-operative setting in five fractions. Dose constraints to the OAR Extreme were calculated with a BED calculator using an alpha/beta ratio of 3 to reduce the risk of late toxicities. QoL data was collected from patients at the time of consultation and at subsequent follow up appointments using the MD Anderson Dysphagia Inventory (MDADI) and Symptom Inventory (MDASI). Results: The 1- and 2- year rates of local, regional, and distant control and overall survival were 79/79, 74/70, 74/71, and 59/45%, respectively. Late grade 3 toxicities were seen in 3% in the group treated to the aerodigestive tract and 1% in the group treated to the skull base. No grade 4 or 5 toxicities were observed. Patients with skull base re-irradiation maintained a stable QoL score after radiation treatment, while patients treated to the aerodigestive tract demonstrated a slight impairment associated with worsening dysphagia, compared to their pretreatment baseline. All groups experienced an increase in xerostomia. Conclusions: OAR Extreme -sparing SBRT is able to achieve excellent tumor coverage while protecting the organs at highest risk of re-irradiation-related complications. The potential for lower toxicities and maintained QoL with this treatment makes it a promising option for salvage of recurrent head and neck cancer. SUMMARY: Local control and overall survival rates for recurrent head and neck cancer remain poor, despite the use of local therapy. In addition, re-irradiation with conventional radiation therapy confers a high rate of grade 3 and higher late toxicities. SBRT appears to improve the therapeutic ratio in this patient population, and treatment planning with a focus on sparing OAR Extreme may further decrease the rates of morbidity in these patients.

4.
Pract Radiat Oncol ; 7(3): 183-189, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28477798

RESUMEN

PURPOSE: Our purpose was to evaluate hippocampal doses and target volume coverage with and without hippocampal sparing when treating multiple brain metastases using various stereotactic radiosurgery (SRS) platforms. METHODS AND MATERIALS: We selected 10 consecutive patients with 14 separate treatments who had been treated in our department for 3 to 10 brain metastases and added hippocampal avoidance contours. All 14 treatments were planned with GammaPlan for Gamma Knife, Eclipse for single isocenter volumetric modulated arc therapy (VMAT), TomoTherapy Treatment Planning System (TPS) for TomoTherapy, and MultiPlan for CyberKnife. Initial planning was performed with the goal of planning target volume coverage of V100 ≥95% without hippocampal avoidance. If the maximum hippocampal point dose (Dmax) was <6.6 Gy in a single fraction and <40% of the hippocampi received ≤4.5 Gy, no second plan was performed. If either constraint was not met, replanning was performed with these constraints. RESULTS: There was a median of 6 metastases per plan, with an average total tumor volume of 7.32 mL per plan. The median hippocampal Dmax (in Gy) without sparing averaged 1.65, 9.81, 4.38, and 5.46, respectively (P < .0001). Of 14 plans, 3 Gamma Knife and CyberKnife plans required replanning, whereas 13 VMAT and 8 TomoTherapy plans required replanning. The hippocampal constraints were not achievable in 1 plan on any platform when the tumor was bordering the hippocampus. The mean volume of brain receiving 12 Gy (in mL), which has been associated with symptomatic radionecrosis, was 23.57 with Gamma Knife, 76.77 with VMAT, 40.86 with CyberKnife, and 104.06 with TomoTherapy (P = .01). The overall average conformity indices for all plans ranged from 0.36 to 0.52. CONCLUSIONS: Even with SRS, the hippocampi can receive a considerable dose; however, if the hippocampi are outlined as organs of risk, sparing these structures is feasible in nearly all situations with all 4 platforms, without detriment to target coverage, and should be considered in all patients undergoing SRS for multiple brain metastases. SUMMARY: Hippocampi play an important role in memory, and sparing of these structures in whole brain radiation can improve neurocognitive outcomes. The hippocampi are not routinely spared when using stereotactic radiosurgery. We evaluated the incidental dose to the hippocampi when treating multiple brain metastases and sought to examine if hippocampal sparing is feasible without detriment to target coverage. We found that hippocampal sparing is possible without affecting coverage or conformality in most cases across treatment platforms.


Asunto(s)
Neoplasias Encefálicas/radioterapia , Hipocampo , Tratamientos Conservadores del Órgano/métodos , Radiocirugia/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias Encefálicas/patología , Neoplasias Encefálicas/secundario , Hipocampo/efectos de la radiación , Humanos , Radiocirugia/efectos adversos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Resultado del Tratamiento , Carga Tumoral/efectos de la radiación