1.
Biomaterials ; 24(9): 1671-9, 2003 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-12559827

RESUMEN

The purpose of this study was to compare the mechanical behavior of calf pericardium, pig pericardium and ostrich pericardium when subjected to tensile testing. Tensile stress was applied to 108 tissue samples, 36 of each type of tissue, until rupture. Groups of three adjacent strips measuring 12 x 2 cm(2) were cut longitudinally. Each group consisted of an unsutured center sample, or control, and the two contiguous samples, that on the right sutured with Gore-Tex at a 90 degrees angle with respect to the longitudinal axis and that on the left sewn with the same suture material at 45 degrees angle. The sutured samples showed a statistically significant loss of resistance (p<0.001) when compared with the corresponding unsutured tissue. The mean stresses at rupture for sutured ostrich pericardium were 21.81 and 20.81 MPa in the samples sewn at 45 degrees and 90 degrees, respectively, higher than those corresponding to unsutured calf and pig pericardium, 14.0 and 11.49 MPa, respectively, at rupture. The analysis of the stress/strain curve shows a smaller difference between sutured and unsutured ostrich pericardium than those observed in the other two biomaterials. These results demonstrate that, in addition to its greater resistance, ostrich pericardium also presents a less pronounced interaction with the suture material. Its capacity to absorb the shearing stress produced by the suture is greater. This report also confirms that the method of selection using paired samples ensures their homogeneity and makes it possible to predict the behavior of a sample by determining that of the other half of the pair.


Asunto(s)
Materiales Biocompatibles , Pericardio/cirugía , Animales , Fenómenos Biomecánicos , Bovinos , Politetrafluoroetileno , Struthioniformes , Porcinos
2.
J Biomater Appl ; 17(2): 85-103, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12557996

RESUMEN

The authors study the mechanical behavior of calf pericardium employed in the construction of cardiac valve leaflets when subjected to telescoping suture, followed by tensile stress until rupture. One hundred twenty pericardial tissue samples were employed, 60 cut from root-to-apex and another 60 cut in transverse direction. Each of these two groups consisted of 12 control samples that were left unsutured and four sets of 12 samples each that were rejoined by telescoping suture using silk, Prolene, nylon or Gore-Tex., and subjected to tensile stress. At the rupture of the sutured tissues, the tensile stress of the suture materials ranged between 57.54 MPa for the series sewn lengthwise with Gore-tex and 114.08 MPa for the series sewn crosswise with silk. At these levels of stress, the deformation of the suture thread was much less marked than that of the calf pericardium, and internal stresses were produced that were difficult for the biomaterial to absorb. There was a loss of real load in all the sutured series when the observed resistance to rupture, expressed in kilograms, was compared with the estimated value. This loss of resistance did not invalidate the telescoping suture technique since the resistance to rupture was still much greater than that associated with suturing the two edges of the cut pericardium together. This report confirms the deleterious role of the shear force generated in the pericardium by the suture.


Asunto(s)
Materiales Biocompatibles , Pericardio/fisiología , Suturas , Animales , Bioprótesis , Bovinos , Técnicas In Vitro , Ensayo de Materiales
3.
J Biomater Appl ; 17(2): 105-23, 2002 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-12557997

RESUMEN

Ostrich pericardium, sutured using a telescoping or overlapping technique, was studied to determine its mechanical behavior. From each of 12 pericardial sacs, four contiguous strips were cut longitudinally, from root to apex, and another four contiguous strips were cut in transverse direction. One of the strips in each set of four was used as an unsutured control and the remaining three were sutured by overlapping 0.5 cm of the tissue and sewing with Gore-tex, Prolene or Pronova. These 96 samples were then subjected to tensile testing along their major axes until rupture. The tensile stresses recorded in the suture materials at the moment tears appeared in the pericardium ranged between 55.99 MPa and 70.23 MPa for Gore-tex in samples cut in the two directions. Shear stress became ostensible at 56 MPa, with clearly evident tears. However, microfracture of the collagen fibers must be produced at much lower stress levels. The comparison of the resistance in kilograms (machine-imposed), without taking into account the sections in which the load was applied, demonstrated only a slight loss of load when the telescoping suture was employed in ostrich pericardium samples. Ostrich pericardium may continue to be an alternative biological material for the construction of heart valve leaflets.


Asunto(s)
Materiales Biocompatibles , Pericardio/fisiología , Suturas , Animales , Bioprótesis , Ensayo de Materiales , Struthioniformes
4.
J Mater Sci Mater Med ; 12(10-12): 1013-7, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-15348357

RESUMEN

The purpose of this study was to evaluate the influence of two anticalcification pre-treatments (chloroform/methanol and ethanol) and serum conditioning of glutaraldehyde-crosslinked bovine pericardium on the calcification degree and the presence of gelatinase activities in a subcutaneous implantation model in rats. Regarding calcification of the implants, glutaraldehyde control treatments showed a significatively higher calcification degree than pericardium treated with anticalcification reagents. Serum conditioning of glutaraldehyde treated tissues did not influence the calcification degree; moreover, no differences were found in these samples with the time of implantation (30 and 90 days). On the other hand, anticalcification treatments resulted in a very significant decrease in the calcium content in the implanted membranes. Gelatinase activities were detected by gelatin zymography in almost all the implanted samples. However, control tissues with and without serum conditioning showed less gelatinase activities than those samples pre-treated with anticalcification treatments. Metalloproteinase (MMP-2) activity was detected in all the samples analyzed but a higher expression of MMP-9 was detected in those implants treated with chloroform/methanol and ethanol. Additional gelatinase activities showing lower molecular weight than MMP-2 were also detected in both anticalcification treated samples. The presence of these gelatinase activities is probably due to host cellular infiltrates and could contribute to the biomaterial degradation.