1.
Radiol Med ; 127(10): 1098-1105, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36070066

RESUMEN

PURPOSE: To compare liver MRI with AIR Recon Deep Learning™(ARDL) algorithm applied and turned-off (NON-DL) with conventional high-resolution acquisition (NAÏVE) sequences, in terms of quantitative and qualitative image analysis and scanning time. MATERIAL AND METHODS: This prospective study included fifty consecutive volunteers (31 female, mean age 55.5 ± 20 years) from September to November 2021. 1.5 T MRI was performed and included three sets of images: axial single-shot fast spin-echo (SSFSE) T2 images, diffusion-weighted images(DWI) and apparent diffusion coefficient(ADC) maps acquired with both ARDL and NAÏVE protocol; the NON-DL images, were also assessed. Two radiologists in consensus drew fixed regions of interest in liver parenchyma to calculate signal-to-noise-ratio (SNR) and contrast to-noise-ratio (CNR). Subjective image quality was assessed by two other radiologists independently with a five-point Likert scale. Acquisition time was recorded. RESULTS: SSFSE T2 objective analysis showed higher SNR and CNR for ARDL vs NAÏVE, ARDL vs NON-DL(all P < 0.013). Regarding DWI, no differences were found for SNR with ARDL vs NAÏVE and, ARDL vs NON-DL (all P > 0.2517).CNR was higher for ARDL vs NON-DL(P = 0.0170), whereas no differences were found between ARDL and NAÏVE(P = 1). No differences were observed for all three comparisons, in terms of SNR and CNR, for ADC maps (all P > 0.32). Qualitative analysis for all sequences showed better overall image quality for ARDL with lower truncation artifacts, higher sharpness and contrast (all P < 0.0070) with excellent inter-rater agreement (k ≥ 0.8143). Acquisition time was lower in ARDL sequences compared to NAÏVE (SSFSE T2 = 19.08 ± 2.5 s vs. 24.1 ± 2 s and DWI = 207.3 ± 54 s vs. 513.6 ± 98.6 s, all P < 0.0001). CONCLUSION: ARDL applied on upper abdomen showed overall better image quality and reduced scanning time compared with NAÏVE protocol.


Asunto(s)
Inteligencia Artificial , Imagen Eco-Planar , Adulto , Anciano , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos , Femenino , Humanos , Aumento de la Imagen/métodos , Hígado/diagnóstico por imagen , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Prospectivos , Reproducibilidad de los Resultados
2.
Diagnostics (Basel) ; 14(4)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38396418

RESUMEN

Magnetic resonance elastography (MRE) is an imaging technique that combines low-frequency mechanical vibrations with magnetic resonance imaging to create visual maps and quantify liver parenchyma stiffness. As in recent years, diffuse liver diseases have become highly prevalent worldwide and could lead to a chronic condition with different stages of fibrosis. There is a strong necessity for a non-invasive, highly accurate, and standardised quantitative assessment to evaluate and manage patients with different stages of fibrosis from diagnosis to follow-up, as the actual reference standard for the diagnosis and staging of liver fibrosis is biopsy, an invasive method with possible peri-procedural complications and sampling errors. MRE could quantitatively evaluate liver stiffness, as it is a rapid and repeatable method with high specificity and sensitivity. MRE is based on the propagation of mechanical shear waves through the liver tissue that are directly proportional to the organ's stiffness, expressed in kilopascals (kPa). To obtain a valid assessment of the real hepatic stiffness values, it is mandatory to obtain a high-quality examination. To understand the pearls and pitfalls of MRE, in this review, we describe our experience after one year of performing MRE from indications and patient preparation to acquisition, quality control, and image analysis.

3.
Cancers (Basel) ; 16(3)2024 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-38339411

RESUMEN

The aim of this study was to compare CT radiomics and morphological features when assessing benign lymph nodes (LNs) in colon cancer (CC). This retrospective study included 100 CC patients (test cohort) who underwent a preoperative CT examination and were diagnosed as pN0 after surgery. Regional LNs were scored with a morphological Likert scale (NODE-SCORE) and divided into two groups: low likelihood (LLM: 0-2 points) and high likelihood (HLM: 3-7 points) of malignancy. The T-test and the Mann-Whitney test were used to compare 107 radiomic features extracted from the two groups. Radiomic features were also extracted from primary lesions (PLs), and the receiver operating characteristic (ROC) was used to test a LN/PL ratio when assessing the LN's status identified with radiomics and with the NODE-SCORE. An amount of 337 LNs were divided into 167 with LLM and 170 with HLM. Radiomics showed 15/107 features, with a significant difference (p < 0.02) between the two groups. The comparison of selected features between 81 PLs and the corresponding LNs showed all significant differences (p < 0.0001). According to the LN/PL ratio, the selected features recognized a higher number of LNs than the NODE-SCORE (p < 0.001). On validation of the cohort of 20 patients (10 pN0, 10 pN2), significant ROC curves were obtained for LN/PL busyness (AUC = 0.91; 0.69-0.99; 95% C.I.; and p < 0.001) and for LN/PL dependence entropy (AUC = 0.76; 0.52-0.92; 95% C.I.; and p = 0.03). The radiomics ratio between CC and LNs is more accurate for noninvasively discriminating benign LNs compared to CT morphological features.

4.
Diagnostics (Basel) ; 12(8)2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-36010337

RESUMEN

Background: to assess the performance and speed of two commercially available advanced cardiac software packages in the automated identification of coronary vessels as an aiding tool for inexperienced readers. Methods: Hundred and sixty patients undergoing coronary CT angiography (CCTA) were prospectively enrolled from February until September 2021 and randomized in two groups, each one composed by 80 patients. Patients in group 1 were scanned on Revolution EVO CT Scanner (GE Healthcare), while patients in group 2 had the CCTA performed on Brilliance iCT (Philips Healthcare); each examination was evaluated on the respective vendor proprietary advanced cardiac software (software 1 and 2, respectively). Two inexperienced readers in cardiac imaging verified the software performance in the automated identification of the three major coronary vessels: (RCA, LCx, and LAD) and in the number of identified coronary segments. Time of analysis was also recorded. Results: software 1 correctly and automatically nominated 202/240 (84.2%) of the three main coronary vessels, while software 2 correctly identified 191/240 (79.6%) (p = 0.191). Software 1 achieved greater performances in recognizing the LCx (81.2% versus 67.5%; p = 0.048), while no differences have been reported in detecting the RCA (p = 0.679), and the LAD (p = 0.618). On a per-segment analysis, software 1 outperformed software 2, automatically detecting 942/1062 (88.7%) coronary segments, while software 2 detected 797/1078 (73.9%) (p < 0.001). Average reconstruction and detection time was of 13.8 s for software 1 and 21.9 s for software 2 (p < 0.001). Conclusions: automated cardiac software packages are a reliable and time-saving tool for inexperienced reader. Software 1 outperforms software 2 and might therefore better assist inexperienced CCTA readers in automated identification of the three main vessels and coronaries segments, with a consistent time saving of the reading session.

5.
Biomed Res Int ; 2022: 1147111, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36619303

RESUMEN

Diffuse liver diseases are highly prevalent conditions around the world, including pathological liver changes that occur when hepatocytes are damaged and liver function declines, often leading to a chronic condition. In the last years, Magnetic Resonance Imaging (MRI) is reaching an important role in the study of diffuse liver diseases moving from qualitative to quantitative assessment of liver parenchyma. In fact, this can allow noninvasive accurate and standardized assessment of diffuse liver diseases and can represent a concrete alternative to biopsy which represents the current reference standard. MRI approach already tested for other pathologies include diffusion-weighted imaging (DWI) and radiomics, able to quantify different aspects of diffuse liver disease. New emerging MRI quantitative methods include MR elastography (MRE) for the quantification of the hepatic stiffness in cirrhotic patients, dedicated gradient multiecho sequences for the assessment of hepatic fat storage, and iron overload. Thus, the aim of this review is to give an overview of the technical principles and clinical application of new quantitative MRI techniques for the evaluation of diffuse liver disease.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatopatías , Humanos , Hepatopatías/diagnóstico por imagen , Hepatopatías/patología , Imagen por Resonancia Magnética/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Imagen de Difusión por Resonancia Magnética , Hepatocitos/patología , Diagnóstico por Imagen de Elasticidad/métodos , Cirrosis Hepática/diagnóstico por imagen , Cirrosis Hepática/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA