Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 61(1): 123-132, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36117243

RESUMEN

OBJECTIVES: Clinical laboratory investigation of autoimmune, metabolic, and oncologic disorders in children and adolescents relies on appropriateness of reference intervals (RIs). The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) previously established comprehensive pediatric RIs for specialized immunoassays on the Abbott ARCHITECT system. Herein, we aim to verify performance on new Alinity i assays by evaluating sera collected from healthy children as per Clinical and Laboratory Standards Institute (CLSI) EP-28A3C guidelines. METHODS: Precision, linearity, and method comparison experiments were completed for 17 specialized Alinity immunoassays, including cancer antigens, autoimmune peptides, and hormones. Sera collected from healthy children and adolescents (birth-18 years, n=100) were evaluated. CLSI-based verification was completed using previously established CALIPER RIs for ARCHITECT assays as the reference. RESULTS: Of 17 specialized immunoassays assays, only anti-cyclic citrullinated peptides (anti-CCP) did not meet acceptable verification criterion (i.e., ≥90% of results within ARCHITECT reference CI). Anti-thyroglobulin, anti-thyroid peroxidase, and carcinoembryonic antigen did not require age-specific consideration beyond one year of age, with 63, 91, and 80% of samples equalling the limit of detection, respectively. Estimates were separated by sex for relevant assays (e.g., sex hormone binding globulin, total and free prostate specific antigen). CONCLUSIONS: Findings support transferability of pediatric RIs on ARCHITECT system to the Alinity system for 16 specialized immunoassays in the CALIPER cohort and will be a useful resource for pediatric clinical laboratories using Alinity assays. Further work is needed to establish evidence-based interpretative recommendations for anti-CCP and continue to evaluate pediatric RI acceptability for newly available assay technologies.


Asunto(s)
Anticuerpos Antiproteína Citrulinada , Neoplasias , Masculino , Niño , Humanos , Adolescente , Valores de Referencia , Inmunoensayo , Estudios de Cohortes , Neoplasias/diagnóstico
2.
Clin Chem Lab Med ; 59(9): 1554-1562, 2021 08 26.
Artículo en Inglés | MEDLINE | ID: mdl-34008378

RESUMEN

OBJECTIVES: The quality of clinical laboratory service depends on quality laboratory operations and accurate test result interpretation based on reference intervals (RIs). As new analytical systems continue to be developed and improved, previously established RIs must be verified. The Canadian Laboratory Initiative on Pediatric Reference Intervals (CALIPER) has established comprehensive RIs for many biomarkers on several analytical systems. Here, published CALIPER RIs for 28 chemistry assays on the Abbott ARCHITECT were assessed for verification on the newer Alinity system. METHODS: An analytical validation was first completed to assess assay performance. CALIPER serum samples (100) were analyzed for 28 chemistry assays on the Alinity system. The percentage of results falling within published pediatric ARCHITECT reference and confidence limits was determined for each analyte. Based on Clinical and Laboratory Standards Institute (CLSI) guidelines, if ≥90% of test results fell within confidence limits of ARCHITECT assay RIs, they were considered verified. RESULTS: Of the 28 assays assessed, 26 met the criteria for verification. Reference values for calcium and magnesium did not meet the criteria for verification with 87% and 35% falling within previously established ARCHITECT confidence limits, respectively. However, both assays could be verified using pediatric RIs provided in the Abbott Alinity package insert. CONCLUSIONS: In this study, CALIPER ARCHITECT RIs were verified on the Alinity system for several chemistry assays. These data demonstrate excellent concordance for most assays between the Abbott ARCHITECT and Alinity systems and will assist in the implementation of the Alinity system in pediatric healthcare institutions.


Asunto(s)
Bioensayo , Servicios de Laboratorio Clínico , Bioensayo/métodos , Niño , Humanos , Magnesio , Estándares de Referencia , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA