Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Phys Rev Lett ; 132(6): 062702, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38394565

RESUMEN

The cross section of the ^{13}C(α,n)^{16}O reaction is needed for nuclear astrophysics and applications to a precision of 10% or better, yet inconsistencies among 50 years of experimental studies currently lead to an uncertainty of ≈15%. Using a state-of-the-art neutron detection array, we have performed a high resolution differential cross section study covering a broad energy range. These measurements result in a dramatic improvement in the extrapolation of the cross section to stellar energies potentially reducing the uncertainty to ≈5% and resolving long standing discrepancies in higher energy data.

2.
Aviat Space Environ Med ; 64(11): 992-9, 1993 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-8280047

RESUMEN

Degradation of air quality in the Space Shuttle environment through chemical contamination and high solid-particulate levels may affect crew performance and health. A comprehensive study of the Shuttle atmosphere was undertaken during the STS-40 (Spacelab Space Life Sciences 1) and STS-42 (Spacelab International Microgravity Laboratory 1) missions to determine the effectiveness of contaminant control procedures by measuring concentrations of volatile organic compounds and analyzing particulate matter trapped on air filters. Analysis of volatile contaminants showed that the air was toxicologically safe to breathe during both missions with the exception of one period during STS-40 when the Orbiter Refrigerator/Freezer was releasing noxious gases into the middeck. Chemical analyses of selected particles collected on air filters facilitated their positive identification. Trace amounts of rat hair and food particles were found in the STS-40 Spacelab filters; a trace amount of soilless plant-growth media was detected in the STS-42 Spacelab filter. The low levels of particles released from these Spacelab experiments indicate that containment measures were effective.


Asunto(s)
Contaminación del Aire Interior/análisis , Vuelo Espacial , Alcoholes/análisis , Aldehídos/análisis , Hidrocarburos/análisis
3.
Anal Chem ; 66(18): 2820-8, 1994 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-11536649

RESUMEN

Biological particulates collected on air filters during shuttle missions (STS-40 and STS-42) were identified using pyrolysis-gas chromatography/mass spectrometry (Py-GC/MS). A method was developed for identifying the atmospheric particles and their sources through the analysis of standard materials and the selection of "marker" compounds specific to the particle type. Pyrolysis spectra of biological standards were compared with those of airborne particles collected during two space shuttle missions; marker compounds present in the shuttle particle spectra were matched with those of the standards to identify the source of particles. Particles of 0,5--1-mm diameter and weighing as little as 40 micrograms could be identified using this technique. The Py-GC/MS method identified rat food and soilless plant-growth media as two sources of particles collected from the shuttle atmosphere during flight.


Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Vuelo Espacial/instrumentación , Ingravidez , Alimentación Animal/análisis , Animales , Medios de Cultivo/análisis , Estudios de Evaluación como Asunto , Heces , Cromatografía de Gases y Espectrometría de Masas/instrumentación , Calor , Tamaño de la Partícula , Ratas , Ratas Sprague-Dawley , Estándares de Referencia , Reproducibilidad de los Resultados
4.
AIHAJ ; 61(1): 69-75, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-10772617

RESUMEN

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.


Asunto(s)
Contaminantes Ocupacionales del Aire/análisis , Monitoreo del Ambiente/instrumentación , Exposición Profesional/prevención & control , Compuestos Orgánicos/análisis , Polímeros/normas , Nave Espacial , Adsorción , Humanos , Estados Unidos , United States National Aeronautics and Space Administration , Volatilización
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA