Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Proteome Res ; 23(8): 3052-3063, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-38533909

RESUMEN

Quantitation of proteins using liquid chromatography-tandem mass spectrometry (LC-MS/MS) is complex, with a multiplicity of options ranging from label-free techniques to chemically and metabolically labeling proteins. Increasingly, for clinically relevant analyses, stable isotope-labeled (SIL) internal standards (ISs) represent the "gold standard" for quantitation due to their similar physiochemical properties to the analyte, wide availability, and ability to multiplex to several peptides. However, the purchase of SIL-ISs is a resource-intensive step in terms of cost and time, particularly for screening putative biomarker panels of hundreds of proteins. We demonstrate an alternative strategy utilizing nonhuman sera as the IS for quantitation of multiple human proteins. We demonstrate the effectiveness of this strategy using two high abundance clinically relevant analytes, vitamin D binding protein [Gc globulin] (DBP) and albumin (ALB). We extend this to three putative risk markers for cardiovascular disease: plasma protease C1 inhibitor (SERPING1), annexin A1 (ANXA1), and protein kinase, DNA-activated catalytic subunit (PRKDC). The results show highly specific, reproducible, and linear measurement of the proteins of interest with comparable precision and accuracy to the gold standard SIL-IS technique. This approach may not be applicable to every protein, but for many proteins it can offer a cost-effective solution to LC-MS/MS protein quantitation.


Asunto(s)
Cromatografía Líquida con Espectrometría de Masas , Espectrometría de Masas en Tándem , Animales , Humanos , Biomarcadores/sangre , Análisis Costo-Beneficio , Marcaje Isotópico/métodos , Cromatografía Líquida con Espectrometría de Masas/métodos , Péptidos/química , Péptidos/sangre , Péptidos/análisis , Proteómica/métodos , Proteómica/economía , Estándares de Referencia , Reproducibilidad de los Resultados , Albúmina Sérica/análisis , Albúmina Sérica/química , Espectrometría de Masas en Tándem/métodos , Tripsina/química , Tripsina/metabolismo , Proteína de Unión a Vitamina D/sangre , Proteína de Unión a Vitamina D/química
2.
Rapid Commun Mass Spectrom ; 38(22): e9892, 2024 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-39287025

RESUMEN

RATIONALE: Heavy-labelled internal standards increasingly represent the gold standard for absolute quantitation in mass spectrometry (MS)-based bottom-up proteomics. The biggest drawbacks of using these standards are that they have high costs and lengthy lead times. METHODS: We describe an efficient, low-cost optimised method to enable 'in-house' heavy labelling of synthetic tryptic peptides for absolute quantification using tandem LC-MS/MS mass spectrometry. Our methodology uses 18O water in a trypsin-catalysed oxygen exchange reaction at the carboxyl terminus with the overall aim of reducing the costs and lead time associated with sourcing heavy standards from commercial vendors. RESULTS: Step-by-step instructions are provided on how to execute this protocol with high-throughput adaptations utilising a 96-well plate and a liquid-handling robot. Detailed notes on experimental setup, tips for troubleshooting and suggested improvements to maximise labelling efficiencies are highlighted to achieve the best results. Under optimum conditions, labelling efficiencies of peptides can reach from 95% to 100%. CONCLUSIONS: The application of the 'in-house' labelled standards in generating calibration curves to quantify endogenous peptide concentrations is just as effective as using the synthetically sourced standards while also having great cost reduction implications as well as saving time spent waiting for peptides to arrive. The protocol is highly adaptable and can be customized to fit the specific setup of any laboratory, maximizing achievable labelling efficiencies.


Asunto(s)
Marcaje Isotópico , Péptidos , Proteómica , Espectrometría de Masas en Tándem , Proteómica/métodos , Espectrometría de Masas en Tándem/métodos , Péptidos/química , Péptidos/análisis , Marcaje Isotópico/métodos , Isótopos de Oxígeno/análisis , Isótopos de Oxígeno/química , Tripsina/química , Tripsina/metabolismo , Cromatografía Liquida/métodos
3.
BMC Cardiovasc Disord ; 24(1): 25, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172712

RESUMEN

BACKGROUND: Heart failure with preserved ejection fraction (HFpEF) is a heterogenous multi-system syndrome with limited efficacious treatment options. The prevalence of Type 2 diabetes (T2D) continues to rise and predisposes patients to HFpEF, and HFpEF remains one of the biggest challenges in cardiovascular medicine today. Novel therapeutic targets are required to meet this important clinical need. Deep phenotyping studies including -OMIC analyses can provide important pathogenic information to aid the identification of such targets. The aims of this study were to determine; 1) the impact of a low-energy diet on plasma sphingolipid/ceramide profiles in people with T2D compared to healthy controls and, 2) if the change in sphingolipid/ceramide profile is associated with reverse cardiovascular remodelling. METHODS: Post-hoc analysis of a randomised controlled trial (NCT02590822) including adults with T2D with no cardiovascular disease who completed a 12-week low-energy (∼810 kcal/day) meal-replacement plan (MRP) and matched healthy controls (HC). Echocardiography, cardiac MRI and a fasting blood for lipidomics were undertaken pre/post-intervention. Candidate biomarkers were identified from case-control comparison (fold change > 1.5 and statistical significance p < 0.05) and their response to the MRP reported. Association between change in biomarkers and change indices of cardiac remodelling were explored. RESULTS: Twenty-four people with T2D (15 males, age 51.1 ± 5.7 years), and 25 HC (15 male, 48.3 ± 6.6 years) were included. Subjects with T2D had increased left ventricular (LV) mass:volume ratio (0.84 ± 0.13 vs. 0.70 ± 0.08, p < 0.001), increased systolic function but impaired diastolic function compared to HC. Twelve long-chain polyunsaturated sphingolipids, including four ceramides, were downregulated in subjects with T2D at baseline. Three sphingomyelin species and all ceramides were inversely associated with LV mass:volume. There was a significant increase in all species and shift towards HC following the MRP, however, none of these changes were associated with reverse cardiac remodelling. CONCLUSION: The lack of association between change in sphingolipids/ceramides and reverse cardiac remodelling following the MRP casts doubt on a causative role of sphingolipids/ceramides in the progression of heart failure in T2D. TRIAL REGISTRATION: NCT02590822.


Asunto(s)
Diabetes Mellitus Tipo 2 , Insuficiencia Cardíaca , Remodelación Ventricular , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Biomarcadores , Ceramidas , Ayuno , Esfingolípidos , Volumen Sistólico/fisiología , Función Ventricular Izquierda
4.
J Am Soc Mass Spectrom ; 34(6): 1065-1072, 2023 Jun 07.
Artículo en Inglés | MEDLINE | ID: mdl-37155737

RESUMEN

In order for mass spectrometry to continue to grow as a platform for high-throughput clinical and translational research, careful consideration must be given to quality control by ensuring that the assay performs reproducibly and accurately and precisely. In particular, the throughput required for large cohort clinical validation in biomarker discovery and diagnostic screening has driven the growth of multiplexed targeted liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) assays paired with sample preparation and analysis in multiwell plates. However, large scale MS-based proteomics studies are often plagued by batch effects: sources of technical variation in the data, which can arise from a diverse array of sources such as sample preparation batches, different reagent lots, or indeed MS signal drift. These batch effects can confound the detection of true signal differences, resulting in incorrect conclusions being drawn about significant biological effects or lack thereof. Here, we present an intraplate batch effect termed the edge effect arising from temperature gradients in multiwell plates, commonly reported in preclinical cell culture studies but not yet reported in a clinical proteomics setting. We present methods herein to ameliorate the phenomenon including proper assessment of heating techniques for multiwell plates and incorporation of surrogate standards, which can normalize for intraplate variation.


Asunto(s)
Proteómica , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Proteómica/métodos , Control de Calidad , Estándares de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA